Clinical trials: Myopic Astigmatism, active
Refractive Assessment, Refractive Disorders
Algorithm-assisted Subjective Refraction Program Dedicated to Children
Current refraction assessment in children is dependent on the Eye Care Specialist and lacks standardization. Essilor has developed new algorithm assisted subjective refraction software dedicated to children of 6-12 years old and…
- Conditions
- Refractive Assessment, Refractive Disorders, Hyperopia and Myopia, Astigmatism
- Trial name
- NCT07046065
- Testing
- Non-cycloplegic Objective refraction, Non-cycloplegic conventional subjective refraction, Non-cycloplegic subjective refraction (Kids refraction software vA with Vision-R™)
- Where
- Portugal
- Volunteers
- 166 people, healthy volunteers welcome
- Sponsor
- Essilor International
Myopia, Myopic Astigmatism
A Clinical Trial Assessing the Safety and Effectiveness of Orthokeratology Lenses in Patients With Myopia and Myopic Astigmatism
This is a prospective, multi-centre, single-arm clinical trial to evaluate the effectiveness and safety of MCOK-01 lenses in patients with myopia and myopic astigmatism who need dioptric correction.
- Trial name
- SEMOA (NCT07047924)
- Testing
- MCOK-01
- Where
- 4 sites in Australia
- Volunteers
- 220 people
- Sponsor
- Menicon Co., Ltd.
Myopia
Development of a New Device and Method to Assess the Degree of Myopia and/or Astigmatism in Myopic People
The purpose of this clinical investigation is to check whether the new device can correctly measure a person's degree of myopia and astigmatism.
- Trial name
- MDSW_DiVA2Rx (NCT07297810)
- Testing
- Optical correction values obtained with investigational device and visual acuity, Optical correction values obtained with an autorefractometer and visual acuity, Optical correction values obtained with a phoropter and visual acuity
- Where
- France
- Volunteers
- 30 people, healthy volunteers welcome
- Sponsor
- Essilor International
Myopia, Astigmatism
SMILE Surgery in One Eye Compared to Ray Tracing-guided LASIK Surgery in the Fellow Eye
Participants will undergo LASIK surgery in one eye using ray tracing guided technology in one eye and LASIK surgery in the other eye using wavefront guided technology.
- Trial name
- NCT07721714
- Testing
- Ray tracing guided LASIK surgery
- Where
- United States
- Volunteers
- 62 people
- Sponsor
- Stanford University
Visual Acuity, Refractive Errors
Assessing the Turkish DDIVAT for Visual Acuity Measurement
The goal of this observational methodological study is to validate the Turkish version of the DDIVAT visual acuity measuring device in a Turkish-speaking adult population.
- Conditions
- Visual Acuity, Refractive Errors, Myopia, Hyperopia
- Trial name
- NCT07240480
- Testing
- DDIVAT Visual Acuity Test (Turkish Version)
- Volunteers
- 200 people, healthy volunteers welcome
- Sponsor
- Trakya University
Astigmatism
Clinical Performance and Outcomes After Toric Lens Transition
To evaluate subjective and clinical outcomes after transitioning from one toric soft contact lens to another over a one-month period.
- Trial name
- NCT07898995
- Testing
- Fanfilcon A Toric Contact Lens
- Where
- United States
- Volunteers
- 35 people
- Sponsor
- CooperVision International Limited (CVIL)
Myopia, Hyperopia
Corneal Epithelial Thickness Mapping by Anterior Segment Optical Coherence Tomography in Patients With Refractive Errors
This study evaluates corneal epithelial thickness using anterior segment optical coherence tomography (AS-OCT) in patients with refractive errors.
- Conditions
- Myopia, Hyperopia, Astigmatism, Emmetropia
- Trial name
- NCT07647146
- Where
- Egypt
- Volunteers
- 360 people, healthy volunteers welcome
- Sponsor
- Sohag University
Myopia, Astigmatism
Wavelight Plus Sightmap-LASIK vs. Wavefront-Optimized-LASIK
The goal of this clinical trial is to learn if the wavelight plus Sightmap (WLP) method or the wavefront-optimized (WFO) method for calculating LASIK customization treatment gives better vision, better satisfaction, and fewer…
- Trial name
- NCT07855094
- Testing
- LASIK calculated ablation using Wavefront-Optimized, wavelight plus Sightmap (WLP) Guided LASIK calculated
- Where
- United States
- Volunteers
- 49 people
- Sponsor
- 59th Medical Wing
Keratoconus, High Myopia
Anterior Segment and Corneal Parameters in Keratoconus and High Myopic Astigmatism Using Schiempflug Imaging
The purpose of this study was to compare Scheimpflug corneal tomography findings in keratoconus and high myopic astigmatic eyes, as well as to establish the parameters distinguishing keratoconus from high myopic astigmatism.
- Trial name
- NCT06739018
- Testing
- pentacam scheimpflug tomography
- Where
- 2 sites in Egypt
- Volunteers
- 66 people
- Sponsor
- Assiut University
Myopia, Astigmatism
Study of a Phakic Implantable Collamer Lens (ICL)
A prospective, open-labeled, single-site study of a phakic implantable collamer lens (ICL) for the correction/reduction of myopia with or without astigmatism.
- Trial name
- NCT07790965
- Testing
- Phakic Implantable Collamer Lens (ICL)
- Volunteers
- 10 people
- Sponsor
- Staar Surgical Company
Myopia, Astigmatism
A Three-Phase Contralateral Comparison of Ray-Tracing Guided LASIK Versus Three Other Refractive Surgery Platforms to Correct Myopia or Myopia With Astigmatism
This purpose of this study is to compare a new form of LASIK called Ray Tracing Guided LASIK to 3 other forms of corneal refractive surgery: 1. KLEx (KeratoLenticule Extraction) using the Zeiss Visumax 800 Laser, 2.
- Trial name
- NCT07201298
- Testing
- Ray-Tracing Guided LASIK, Keratorefractive Lenticule Extraction (KLEx), WaveFront Optimized LASIK
- Where
- United States
- Volunteers
- 120 people, healthy volunteers welcome
- Sponsor
- Hoopes Vision
Myopia, Astigmatism
Clinical Evaluation of WaveLight Plus LASIK
This study is a single-site, single-arm, prospective, observational study of subject satisfaction, quality of vision, and quality of life after bilateral LASIK surgery. Subjects will be assessed up to 3 months post-operatively.
- Trial name
- NCT07127757
- Testing
- Wavelight Plus LASIK
- Where
- United States
- Volunteers
- 50 people
- Sponsor
- Laser Defined Vision
Myopia, Astigmatism
KLEx Versus FS-LASIK for the Treatment of Myopia and Compound Myopic Astigmatism
FemtoLASIK is a type of laser eye surgery used to correct vision problems such as nearsightedness, farsightedness, and astigmatism. It involves two main steps: creating a flap and reshaping the cornea.
- Conditions
- Myopia, Astigmatism, Myopic Astigmatism
- Trial name
- NCT06477081
- Testing
- FS-LASIK procedure, KLEx
- Where
- Mexico
- Volunteers
- 80 people, healthy volunteers welcome
- Sponsor
- Instituto de Oftalmología Fundación Conde de Valenciana
Myopic Astigmatism
A Study to Investigate the Safety and Effectiveness of the Technolas® TENEO 317 Model 2 Excimer Laser for Laser In Situ Keratomileusis (LASIK) Surgery to Treat Myopia or Myopic Astigmatism
This will be a multicenter, prospective, open label, non-randomized, single arm study evaluating the safety and effectiveness of the Technolas® TENEO 317 Model 2 (version 1.28 US software) Excimer Laser when used in LASIK surgery…
- Trial name
- NCT07377474
- Testing
- TENEO 317 Model 2 (1.28 US) Excimer Laser
- Volunteers
- 32 people
- Sponsor
- Bausch & Lomb Incorporated
Myopia, Myopia; Astigmatism
Assessment of IOP After Corneal Refractive Surgery Based on AI
Significance, Background, and Current Status Studies show the global average prevalence of myopia is 22%, with hyperopia incidence being similar.
- Conditions
- Myopia, Myopia; Astigmatism, Refractive Surgery, Intraocular Pressure Changes
- Trial name
- AIOP-CRS-AI (NCT07544615)
- Where
- China
- Volunteers
- 10,030 people, healthy volunteers welcome
- Sponsor
- Tianjin Eye Hospital
Myopia
Acuity 200™ (Fluoroxyfocon A) Orthokeratology Contact Lens for Overnight Wear
The objective of this clinical investigation is to collect scientifically valid safety and effectiveness data on the Acuity 200™ (fluoroxyfocon A) Orthokeratology Contact Lens for Overnight Wear.
- Trial name
- Acuity200OK (NCT06009458)
- Testing
- Acuity 200™ (fluoroxyfocon A) Orthokeratology Contact Lens for Overnight Wear
- Where
- 13 sites in United States, Australia and 1 more
- Volunteers
- 387 people
- Sponsor
- Acuity Polymers, Inc.
Myopia, Astigmatism
Contoura With Phorcides Compared to Wavefront Optimized LASIK
Comparing post-operative visual acuity and patient reported satisfaction between Contoura with Phorcides and WaveLight Wavefront Optimized.
- Trial name
- NCT05486546
- Testing
- Contoura with Phorcides, WaveLight Wavefront Optimized
- Where
- 4 sites in United States
- Volunteers
- 120 people
- Sponsor
- Daniel Terveen
Myopia, Astigmatism
Evaluation of Orthokeratology Lenses With a 5MM Optic Zone Diameter
To evaluate the clinical performance and user-reported experience of Paragon CRT contact lenses with a 5mm Optic Zone Diameter (OZD)
- Trial name
- NCT07751172
- Testing
- Lens A (paflufocon D)
- Where
- 3 sites in United States, Spain
- Volunteers
- 70 people
- Sponsor
- CooperVision International Limited (CVIL)
Myopia, Astigmatism
The EYERISING Study
The purpose of this clinical trial is to see if and how well Repeated Low-Level Red Light (RLRL) therapy works to control myopia over 12 months.
- Conditions
- Myopia, Astigmatism, Anisometropia
- Trial name
- NCT07909720
- Testing
- Repeated Low-Level Red Light (RLRL) therapy
- Where
- 2 sites in United States, Nepal
- Volunteers
- 333 people
- Sponsor
- University of Wisconsin, Madison
Ametropia, Myopia; Refractive Error
The Objective of This Study is to Evaluate the Perfomance of a Photorefraction Device for Screening Ametropia in Children. Eligible Participants Will Undergo Multiple Refractive Error Measurements, Visual Acuity and Strabismus Assessments During a Single Evaluation Visit.
The goal of this clinical trial is to evaluate the performance of a photorefraction screener in terms of sensibility, sensitivity and accuracy on children aged 3 to 8 y.o.
- Conditions
- Ametropia, Myopia; Refractive Error, Myopia; Astigmatism
- Trial name
- NCT06882408
- Testing
- Photorefraction device under investigation, Comparator device, Tabletop auto-refractometer, Comparator device, portable photorefraction device
- Where
- 2 sites in France
- Volunteers
- 315 people, healthy volunteers welcome
- Sponsor
- Essilor International