Clinical trials: Laparoscopic Hernia Repair Surgery
Surgical Training
Study of Fast-track Surgery in Hernia Repair and Laparoscopic Cholecystectomy
All Danish trainees in surgery in a two-year period asked for participation when enrolled in the formal five-year training program for specialty in surgery.
- Trial name
- NCT01877824
- Testing
- Fast-track training
- Where
- Denmark
- Volunteers
- 35 people
- Sponsor
- University of Aarhus
Inguinal Hernia, Surgery
Analgesia Evaluation of an Ultrasound-guided Technique for Inguinal Hernia Surgery in Children in Children
The basis for the transversalis fascia plane (TFP) block involves infiltration of local anaesthetic blocking the ilioinguinal and iliohypogastric nerve which are located between the fascia of the transversus abdominis muscle and…
- Conditions
- Inguinal Hernia, Surgery, Paediatric
- Trial name
- NCT06883370
- Testing
- ultrasound-guided transversals fascia plane block with ropivacaine
- Where
- Malaysia
- Volunteers
- 32 people, healthy volunteers welcome
- Sponsor
- National University of Malaysia
Patients Undergoing Laparoscopic Inguinal Hernia Repair
The Effect of Cold Vapor on Dyspnea, Thirst, Nausea, and Physiological Parameters in the PACU After Laparoscopic Inguinal Hernia Surgery
Cold vapor application is considered a promising intervention with the potential to alleviate side effects associated with anesthesia and surgery in the postoperative period.
- Trial name
- NCT07273162
- Testing
- Cold Vapor
- Where
- Turkey (Türkiye)
- Volunteers
- 66 people
- Sponsor
- TC Erciyes University
Shoulder Pain, Hiatal Hernia
Pain Relief After Hiatal Hernia Repair Surgery
Referred shoulder pain (pain felt when the problem is actually in a different location) is very common after laparoscopic (small, narrow cut) hernia surgery.
- Trial name
- NCT04936711
- Testing
- Resteck Shiatsu Neck and Back Massager, Marcaine
- Where
- United States
- Volunteers
- 90 people
- Sponsor
- Norton Thoracic Institute
Inguinal and Ventral Hernia Repair by Sublay, Underlay and IPOM Mesh Fixation
Effectiveness, Appropriateness and Safety of GLUTACK-Glubran Tiss 2 Surgical Glue Compared to GLUTACK-Glubran 2 Device System for Mesh Fastening in Laparoscopic and Robotic Hernia Surgery
This pre-market, prospective, randomized, non-inferiority clinical study was designed to evaluate the safety and performance/effectiveness of Glutack-Glubran® Tiss 2 system compared to Glutack-Glubran® used for mesh fixation in…
- Trial name
- AGluTHeMFix (NCT06462066)
- Testing
- Experimental medical device, Comparator medical device
- Where
- Italy
- Volunteers
- 101 people
- Sponsor
- GEM SRL
Hernia, Inguinal, Inguinal Hernia, Direct
Study of Laparoscopic Inguinal Hernia Repair
Although mesh fixation has been associated to an increased incidence of nerve injury and involves increased operative costs, many surgeons feel that fixation is necessary to reduce the risk of hernia recurrence.
- Conditions
- Hernia, Inguinal, Inguinal Hernia, Direct, Inguinal Hernia, Indirect, Hernia, Femoral
- Trial name
- NCT02920307
- Testing
- TEP without fixation, TEP with fixation, TAPP without fixation
- Where
- Turkey (Türkiye)
- Volunteers
- 400 people
- Sponsor
- Medical Park Gaziantep Hospital
Abdominal Wall Hernia
Outcomes of Open Versus Robotic-assisted Laparoscopic Posterior Component Separation in Complex Abdominal Wall Repair
This is a retrospective European multicenter study evaluating surgical treatment of patients with a complex ventral incisional hernia using robotic-assisted laparoscopic transversus abdominis release (rTAR) or open transversus…
- Trial name
- EUROTAR (NCT05195957)
- Testing
- Robotic tranversus abdominis release operation, Open transversus abdominis release operation
- Where
- 2 sites in Belgium, Finland
- Volunteers
- 169 people
- Sponsor
- University of Oulu
Incisional Hernia
Incisional Hernia Outcomes Study Using Parietex Composite Mesh
The purpose of this study is to describe the outcomes of laparoscopic incisional hernia repair surgery and to record the outcomes of patients after surgery.
- Trial name
- NCT00459602
- Where
- United States
- Volunteers
- 22 people
- Sponsor
- Columbia University
Inguinal Hernia, Indirect, Surgery
Laparoscopic High-Ligation Repair of Indirect Inguinal Hernias in Adults
Inguinal hernia surgery has undergone significant and extensive transformation, including the advent of tissue-based repairs and later, tension-free repairs with the acceptance of prosthetic mesh.
- Conditions
- Inguinal Hernia, Indirect, Surgery, Postoperative Pain, Recurrence
- Trial name
- NCT06120114
- Testing
- Modified percutaneous internal ring suturing
- Volunteers
- 20 people
- Sponsor
- University Hospital of North Norway
Hernia
Part vs Whole Task Mastery Training for Laparoscopic Hernia Repair
The investigators will perform a randomized controlled trial with a stratified-block design to compare the effect of the part versus whole task simulation training for TEP repairs.
- Trial name
- NCT01629485
- Testing
- Online Video Curriculum, Whole Task Mastery Training, Part Task Mastery Training
- Where
- United States
- Volunteers
- 40 people, healthy volunteers welcome
- Sponsor
- Mayo Clinic
Hernia, Abdominal, Hernia,Ventral
Comparison of Two Mesh/Fixation Concepts for Laparoscopic Ventral and Incisional Hernia Repair
This is a monocenter randomized controlled trial comparing two systems of mesh and fixation device for the laparoscopic ventral and incisional hernia repair with respect to pain.
- Trial name
- NCT02233569
- Testing
- Intraperitoneal onlay mesh (IPOM) repair with the use of Phisiomesh implant and Securestrap fixation device., Intraperitoneal onlay mesh (IPOM) repair with the use of Ventralight ST implant with SorbaFix fixation device., Ventralight ST implant
- Where
- Poland
- Volunteers
- 50 people, healthy volunteers welcome
- Sponsor
- Polish Hernia Study Group
Laparoscopic Surgery, Laparoscopic Appendectomy
Pre-incisional Infiltration With Ropivacaine Plus Diprospan for Relieving Postoperative Pain After Laparoscopic Surgery
Incisional infiltration is the simplest, safest, and most effective anesthesia method for preventing incision pain after laparoscopic surgery, but even using long-acting local anesthetics, the effectiveness of postoperative…
- Conditions
- Laparoscopic Surgery, Laparoscopic Appendectomy, Laparoscopic Cholecystectomy, Laparoscopic Hernia Repair Surgery
- Trial name
- NCT07626463
- Testing
- Pre-incisional infiltration with ropivacaine and diprospan, Pre-incisional infiltration with ropivacaine alone
- Where
- China
- Volunteers
- 150 people
- Sponsor
- Beijing Tiantan Hospital
Inguinal Hernia Unilateral
Laparoscopic Transabdominal Preperitoneal Surgical Repair of Inguinal Hernia Using Sutured Repair Versus Tacker Use
Background: Mesh fixation is a critical step in laparoscopic Transabdominal Preperitoneal (TAPP) hernia repair because fixation is a significant step to prevent the hazard of mesh migration, but is supposed to be associated with…
- Trial name
- NCT05574751
- Testing
- Titanium tacker, Polypropylene 0
- Where
- Egypt
- Volunteers
- 60 people
- Sponsor
- Damanhour Teaching Hospital
Inguinal Hernia
Plasma Total Antioxidant Status and Thiobarbituric Acid-reacting Substances in Patients With Inguinal Hernia
Introduction: Any form of trauma, including surgery is known to result in oxidative stress. Single incision laparoscopy is a step forward towards almost scarless surgery.
- Trial name
- NCT02336256
- Testing
- Procedures of hernia repair.
- Volunteers
- 34 people
- Sponsor
- Poznan University of Medical Sciences
Breast Lumpectomy, Laparoscopic Cholecystectomy
De-Implementation of Low-value Testing in Patients Undergoing Low-Risk Surgery
This trial aims to evaluate the effectiveness of a multi-level, multi-component de-implementation strategy to reduce unnecessary preoperative testing.
- Conditions
- Breast Lumpectomy, Laparoscopic Cholecystectomy, Inguinal Hernia Repair
- Trial name
- NCT06934564
- Testing
- Active de-Implementation
- Where
- United States
- Volunteers
- 16 people
- Sponsor
- University of Michigan
Inguinal Hernia
M-Tapa vs OSTAP for Laparoscopic Inguinal Hernia Repair Surgery
Inguinal hernia repair is the most common of abdominal surgical procedures and is usually performed laparoscopically. Many factors play a role in the pain that develops after surgery and is generally considered to be visceral…
- Trial name
- NCT05476510
- Testing
- Postoperative management
- Where
- Turkey (Türkiye)
- Volunteers
- 60 people
- Sponsor
- Medipol University
Surgery
Maestro LIFT-OFF: Surgical Assistance Device in Abdominal Laparoscopic Surgery
The objective of the study is to provide evidence for the safety and effectiveness of the Maestro Platform for surgical assistance in abdominal laparoscopic surgery.
- Trial name
- Maestro (NCT05243433)
- Testing
- Laparoscopic surgery using the Maestro Platform
- Where
- Belgium
- Volunteers
- 50 people
- Sponsor
- Moon Surgical
Umbilical Hernia, Ventral Hernia
Natural Orifice Translumenal Endoscopic Surgery (NOTES): Laparoscopic Assisted Transvaginal Ventral Hernia Repair
This is a prospective chart review/data collection study of natural orifice translumenal endoscopic surgery (NOTES) for ventral hernia repair, that will include questionnaires administered throughout the study.
- Trial name
- NOTES (NCT01398215)
- Testing
- transvaginal NOTES ventral hernia repair
- Where
- United States
- Volunteers
- 50 people
- Sponsor
- University of California, San Diego
Inguinal Hernia
LESS TEP vs. Three Port TEP for Inguinal Hernia Repair
This study aim to compare efficacy and safety of Laparoendoscopic single site total extraperitoneal inguinal hernia repair /LESS TEP/ and traditional total extraperitoneal hernia repair with 3 ports /TEP/.
- Trial name
- NCT04303182
- Testing
- Standard 3 port TEP, LESS TEP
- Where
- Bulgaria
- Volunteers
- 200 people
- Sponsor
- Sofia Med Hospital
Inguinal Hernia
Mesh Fixation Methods in Laparoscopic Hernia Repair: Glue vs. Sutures vs. Tacks
This study is a clinical trial that aims to compare three different methods for securing a surgical mesh during a specific type of groin (inguinal) hernia repair surgery.
- Trial name
- RCT (NCT07401082)
- Testing
- Cyanoacrylate Surgical Adhesive Fixation, Suture Mesh Fixation, Helical Titanium Tack Fixation
- Where
- Egypt
- Volunteers
- 75 people
- Sponsor
- Cairo University