The primary purpose of the study is to compare the performance of three soft bifocal contact lenses in terms of the vision provided by the lenses. Read more about this study
- Who is it for?
- Ages 35 to 70 years
- Conditions the study is for
- Presbyopia
- What is being tested?
- balafilcon A, senofilcon A production and senofilcon A test
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 37 participants
- Where
- 1 siteUnited States
- Study dates
- 1 Nov 2008to 1 Dec 2008
- Phase
- Interventional
- Are there results?
- Yes, posted in the registrySummary in the doctors' view
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 35 to 70 years
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- The subject must between 35 and 70 years of age.
- The subject must respond positively to at least one symptom on the "Presbyopic Symptoms Questionnaire" or be already wearing presbyopic contact lens correction ( e.g. reading spectacles over contact lenses, multifocal or monovision contact lenses etc.).
- The subject's spherical equivalent distance refraction must be in the range of -1.00 to -6.00 in each eye.
- Refractive cylinder must be less than or equal to -0.75 D in each eye.
- The subject must have an add power of +0.75D to +2.50D in each eye.
- The subject must have best corrected visual acuity of 20/20-3 or better in each eye.
Show all 11Show fewer
- The subject's must have at least 20/30-distance vision with the study contact lenses.
- The subject must agree that they are comfortable with their vision prior to being dispensed the study lenses.
- The subject must be an adapted soft contact lens wearer in both eyes.
- The subject must appear able and willing to adhere to the instructions set forth in this clinical protocol.
- The subject must read and sign the STATEMENT OF INFORMED CONSENT and be provided a copy of the form.
Who cannot join
- Ocular or systemic allergies or disease that may interfere with contact lens wear.
- Systemic disease, autoimmune disease or use of medication, which may interfere with contact lens wear.
- Clinically significant (grade 3 or 4) corneal edema, corneal vascularization, corneal staining or any other abnormality of the cornea, which may contraindicate contact lens wear.
- Clinically significant (grade 3 or 4) tarsal abnormalities that might interfere with contact lens wear.
- Any ocular infection.
- Any corneal distortion resulting from previous hard or rigid gas permeable contact lens wear.
Show all 9Show fewer
- Pregnancy or lactation
- Any infectious disease (e.g., hepatitis, tuberculosis) or a contagious immunosuppressive disease (e.g., HIV).
- History of diabetes. History of binocular vision abnormality or strabismus.
Trial locations and contacts
1 site in 1 country.
About this study
The primary purpose of the study is to compare the performance of three soft bifocal contact lenses in terms of the vision provided by the lenses.
- Conditions
- Presbyopia
- Being tested
- balafilcon A, senofilcon A production, senofilcon A test
- Medical subject headings
- Presbyopia
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
balafilcon ADevice
multifocal contact lens
senofilcon A productionDevice
multifocal contact lens
senofilcon A testDevice
multifocal contact lens
| Study group | Role | What they receive |
|---|---|---|
| senofilA test/senofilA prod/balafilconA | Active comparator | Subjects wear 3 multifocal contact lenses: senofilcon A test worn first, senofilcon A production worn second, and balafilcon A worn third. Receives: Device: balafilcon A; Device: senofilcon A production; Device: senofilcon A test |
| senofilcon A test/balafilcon A/senofilcon A prod | Active comparator | Subjects wear 3 multifocal contact lenses: senofilcon A test worn first, balafilcon A worn second, and senofilcon A production worn third. Receives: Device: balafilcon A; Device: senofilcon A production; Device: senofilcon A test |
| senofilcon A prod/senofilcon A test/balafilcon A | Active comparator | Subjects wear 3 multifocal contact lenses: senofilcon A production worn first, senofilcon A test worn second, and balafilcon A worn third. Receives: Device: balafilcon A; Device: senofilcon A production; Device: senofilcon A test |
| senofilcon A prod/ balifilcon A/ senofilcon A test | Active comparator | Subjects wear 3 multifocal contact lenses: senofilcon A production worn first, balafilcon A worn second, and senofilcon A test worn third. Receives: Device: balafilcon A; Device: senofilcon A production; Device: senofilcon A test |
| balafilcon A/senofilcon A test/senofilcon A prod | Active comparator | Subjects wear 3 multifocal contact lenses: balafilcon A worn first, senofilcon A test worn second, and senofilcon A production worn third. Receives: Device: balafilcon A; Device: senofilcon A production; Device: senofilcon A test |
| balafilcon A/senofilcon A prod/senofilcon A test | Active comparator | Subjects wear 3 multifocal contact lenses: balafilcon A worn first, senofilcon A production worn second, senofilcon A test worn third. Receives: Device: balafilcon A; Device: senofilcon A production; Device: senofilcon A test |
What is being measured
The primary outcome is the main question the study is designed to answer.
Distance Bright Illumination Binocular Visual Performance Reported as Visual Acuity
Tested with both eyes together in bright lighting, reading charts distant to the subject. This outcome is measured in logMAR units.LogMAR stands for the logarithm of the minimum angle of resolution. Ideal is 0.0 and represents 20/20 Snellen acuity. logMAR values > 0.00 indicate vision poorer than the ideal and values <0.00 indicate vision greater than the ideal.
Measured: 5 minutes after insertion
Near Bright Illumination Binocular Visual Performance Reported as Visual Acuity
Tested with both eyes together in bright lighting reading charts near to the subject. This outcome is measured in logMAR units.LogMAR stands for the logarithm of the minimum angle of resolution. Ideal is 0.0 and represents 20/20 Snellen acuity. logMAR values > 0.00 indicate vision poorer than the ideal and values <0.00 indicate vision greater than the ideal.
Measured: 5 minutes after insertion
Type of Corneal Staining
Investigator rated type of corneal staining as either 0=none, 1=micropunctate, 2=macropunctate, 3=coalesced, or 4=patch(> or = to mm).
Measured: after 1 week of lens wear, for each lens type
Overall Subjective Vision
Subject rated the overall quality of vision with the study contact lenses. 5=excellent, 4=very good, 3=good, 2=fair, 1=poor.
Measured: after 1 week of lens wear, for each lens type
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted15 Dec 2008 (estimated)
- Study start1 Nov 2008
- Primary completion1 Dec 2008
- Study completion1 Dec 2008
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Posted resultsParticipant flow, outcome measures and adverse events reported by the sponsor.
- Other trials for PresbyopiaStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Crossover
- Masking
- Single blind
- Who is masked
- Participant
- Enrolment
- 37 participants (actual)
Sponsor and investigators
- Lead sponsor
- Johnson & Johnson Vision Care, Inc.
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT00808340
- Sponsor's protocol ID
- CR-1485FA
- Status last verified
- Aug 2017
- First submitted
- 12 Dec 2008
- Last updated
- 19 Jun 2018
- Results posted
- Yes, on ClinicalTrials.gov
Study at a glance
From the registry record, last updated by the sponsor on 19 Jun 2018. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Comparison of Three Soft Bifocal Contact Lenses
- ClinicalTrials.gov ID
- NCT00808340
- Acronym / sponsor ID
- CR-1485FA
- Conditions
- Presbyopia
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 37 participants (actual)
- Lead sponsor
- Johnson & Johnson Vision Care, Inc.Industry (pharma, biotech, devices)
- Study start
- 1 Nov 2008 (actual)
- Primary completion
- 1 Dec 2008 (actual)
- Study completion
- 1 Dec 2008 (actual)
- First posted
- 15 Dec 2008 (estimated)
- Results
- Posted 26 Aug 2010
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The primary purpose of the study is to compare the performance of three soft bifocal contact lenses in terms of the vision provided by the lenses.
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Crossover
- Masking
- Single blind (participant)
- Number of arms
- 6
| Arm | Type | Receives |
|---|---|---|
| senofilA test/senofilA prod/balafilconA | Active comparator | Device: balafilcon A, Device: senofilcon A production, Device: senofilcon A testSubjects wear 3 multifocal contact lenses: senofilcon A test worn first, senofilcon A production worn second, and balafilcon A worn third. |
| senofilcon A test/balafilcon A/senofilcon A prod | Active comparator | Device: balafilcon A, Device: senofilcon A production, Device: senofilcon A testSubjects wear 3 multifocal contact lenses: senofilcon A test worn first, balafilcon A worn second, and senofilcon A production worn third. |
| senofilcon A prod/senofilcon A test/balafilcon A | Active comparator | Device: balafilcon A, Device: senofilcon A production, Device: senofilcon A testSubjects wear 3 multifocal contact lenses: senofilcon A production worn first, senofilcon A test worn second, and balafilcon A worn third. |
| senofilcon A prod/ balifilcon A/ senofilcon A test | Active comparator | Device: balafilcon A, Device: senofilcon A production, Device: senofilcon A testSubjects wear 3 multifocal contact lenses: senofilcon A production worn first, balafilcon A worn second, and senofilcon A test worn third. |
| balafilcon A/senofilcon A test/senofilcon A prod | Active comparator | Device: balafilcon A, Device: senofilcon A production, Device: senofilcon A testSubjects wear 3 multifocal contact lenses: balafilcon A worn first, senofilcon A test worn second, and senofilcon A production worn third. |
| balafilcon A/senofilcon A prod/senofilcon A test | Active comparator | Device: balafilcon A, Device: senofilcon A production, Device: senofilcon A testSubjects wear 3 multifocal contact lenses: balafilcon A worn first, senofilcon A production worn second, senofilcon A test worn third. |
Who may qualify
- Ages
- 35 to 70 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (11 listed)
- The subject must between 35 and 70 years of age.
- The subject must respond positively to at least one symptom on the "Presbyopic Symptoms Questionnaire" or be already wearing presbyopic contact lens correction ( e.g. reading spectacles over contact lenses, multifocal or monovision contact lenses etc.).
- The subject's spherical equivalent distance refraction must be in the range of -1.00 to -6.00 in each eye.
- Refractive cylinder must be less than or equal to -0.75 D in each eye.
- The subject must have an add power of +0.75D to +2.50D in each eye.
Key exclusion criteria (9 listed)
- Ocular or systemic allergies or disease that may interfere with contact lens wear.
- Systemic disease, autoimmune disease or use of medication, which may interfere with contact lens wear.
- Clinically significant (grade 3 or 4) corneal edema, corneal vascularization, corneal staining or any other abnormality of the cornea, which may contraindicate contact lens wear.
- Clinically significant (grade 3 or 4) tarsal abnormalities that might interfere with contact lens wear.
- Any ocular infection.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| balafilcon Amultifocal contact lens | Device | balafilcon A/senofilcon A prod/senofilcon A test, balafilcon A/senofilcon A test/senofilcon A prod, senofilA test/senofilA prod/balafilconA, senofilcon A prod/ balifilcon A/ senofilcon A test, senofilcon A prod/senofilcon A test/balafilcon A, senofilcon A test/balafilcon A/senofilcon A prod |
| senofilcon A productionmultifocal contact lens | Device | balafilcon A/senofilcon A prod/senofilcon A test, balafilcon A/senofilcon A test/senofilcon A prod, senofilA test/senofilA prod/balafilconA, senofilcon A prod/ balifilcon A/ senofilcon A test, senofilcon A prod/senofilcon A test/balafilcon A, senofilcon A test/balafilcon A/senofilcon A prod |
| senofilcon A testmultifocal contact lens | Device | balafilcon A/senofilcon A prod/senofilcon A test, balafilcon A/senofilcon A test/senofilcon A prod, senofilA test/senofilA prod/balafilconA, senofilcon A prod/ balifilcon A/ senofilcon A test, senofilcon A prod/senofilcon A test/balafilcon A, senofilcon A test/balafilcon A/senofilcon A prod |
Primary outcome
Distance Bright Illumination Binocular Visual Performance Reported as Visual Acuity
Time frame: 5 minutes after insertion
Tested with both eyes together in bright lighting, reading charts distant to the subject. This outcome is measured in logMAR units.LogMAR stands for the logarithm of the minimum angle of resolution. Ideal is 0.0 and represents 20/20 Snellen acuity. logMAR values > 0.00 indicate vision poorer than the ideal and values <0.00 indicate vision greater than the ideal.
Near Bright Illumination Binocular Visual Performance Reported as Visual Acuity
Time frame: 5 minutes after insertion
Tested with both eyes together in bright lighting reading charts near to the subject. This outcome is measured in logMAR units.LogMAR stands for the logarithm of the minimum angle of resolution. Ideal is 0.0 and represents 20/20 Snellen acuity. logMAR values > 0.00 indicate vision poorer than the ideal and values <0.00 indicate vision greater than the ideal.
Type of Corneal Staining
Time frame: after 1 week of lens wear, for each lens type
Investigator rated type of corneal staining as either 0=none, 1=micropunctate, 2=macropunctate, 3=coalesced, or 4=patch(> or = to mm).
Overall Subjective Vision
Time frame: after 1 week of lens wear, for each lens type
Subject rated the overall quality of vision with the study contact lenses. 5=excellent, 4=very good, 3=good, 2=fair, 1=poor.
Results and safety
Loading the posted results from ClinicalTrials.gov…
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 19 Jun 2018.
- Posted resultsParticipant flow, baseline, all outcome measures and adverse events.
Related trials for Presbyopia
Recruiting
Evaluation of Functional Superiority of the Morrow eProgressive
Presbyopia
Active, not recruiting
Clinical Trial With Artiflex Presbyopic (Artiplus)
Presbyopia, Ametropia
Recruiting
VisDura VisAbility™ Micro Insert System Pre-market Clinical Trial
Presbyopia
Recruiting
Volumetric Visual Fields at Intermediate and Near Distances in Presbyopic Patients Using Occupational and General-Purpose Progressive Addition Lenses
Presbyopia
Recruiting
Volumetric Visual Fields at Different Distances in Presbyopic Patients Using Occupational (PC-133 and PC-200) and General-Purpose Progressive Addition Lenses
Presbyopia
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
The record lists no contact. Use the official record to reach the sponsor.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing balafilcon A, senofilcon A production and senofilcon A test in people with Presbyopia, run by Johnson & Johnson Vision Care, Inc. at 1 site in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 11 inclusion and 9 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 19 Jun 2018. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Yes. Results are posted in the registry (first posted 26 Aug 2010). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Distance Bright Illumination Binocular Visual Performance Reported as Visual Acuity (time frame: 5 minutes after insertion). The study lists 4 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?