Clinical trials: Peripheral Pulmonary Lesions (PPLs)
Peripheral Pulmonary Lesions (PPLs)
Clinical Validation Study on the Imaging Efficacy of Mobile 4D CBCT Technology for Peripheral Pulmonary Lesions
The purpose of this study is to evaluate the clinical value of mobile 4D CBCT technology in the diagnosis and treatment of peripheral pulmonary lesions and to validate its intraoperative dynamic three-dimensional CT imaging…
- Trial name
- NCT07149597
- Testing
- Mobile CBCT Three-Dimensional Scanning
- Where
- China
- Volunteers
- 50 people
- Sponsor
- Shanghai Chest Hospital
Lung Cancer
ENB-GS-TBLB for the Diagnosis of PPLs
The purpose of this study is to evaluate the efficacy and safety of electromagnetic navigation bronchoscopy with a Guide Sheath(ENB-GS) for the diagnosis of peripheral pulmonary lesions (PPLs) .
- Trial name
- NCT02207478
- Testing
- ENB, GS-TBLB-X-ray
- Where
- China
- Volunteers
- 80 people
- Sponsor
- Shanghai Chest Hospital
Peripheral Pulmonary Lesions (PPLs), Lung Nodules
Shape-sensing Versus Electromagnetic Robotic Bronchoscopy for Evaluation of PulmoNary LEsions
This is an investigator-initiated, multicenter, non inferiority, cluster randomized controlled trial. The primary objective is to compare the diagnostic yield of the electromagnetic robotic assisted bronchoscopy with digital…
- Trial name
- SERENE (NCT07411989)
- Testing
- Bronchoscopy for peripheral pulmonary lesion biopsy
- Where
- 2 sites in United States
- Volunteers
- 346 people
- Sponsor
- The Cleveland Clinic
Peripheral Pulmonary Lesions (PPLs)
CLE vs. ROSE for Ex Vivo Lung Biopsy Assessment
The goal of this observational study is to evaluate the diagnostic efficacy of Confocal Laser Endomicroscopy (CLE) compared to Rapid On-Site Evaluation (ROSE) for ex vivo lung biopsy specimens obtained via bronchoscopy.
- Trial name
- NCT07725510
- Testing
- Ex Vivo Confocal Laser Endomicroscopy (CLE) Imaging and Interpretation, Rapid On-Site Evaluation (ROSE) Imaging and Interpretation
- Where
- China
- Volunteers
- 30 people
- Sponsor
- Guangzhou Medical University
Lung Cancer
VBN-EBUS-GS-TBLB With or Without Fluoroscopy for the Diagnosis of PPLs
The purpose of this study is to evaluate the feasibility, efficacy and safety of transbronchial lung biopsy (TBLB) and bronchial brushing by using virtual bronchoscopic navigation (VBN) combined with endobronchial ultrasound…
- Trial name
- NCT02484066
- Testing
- VBN, EBUS-GS, X-ray
- Where
- China
- Volunteers
- 436 people
- Sponsor
- Jiayuan Sun
Peripheral Pulmonary Lesions (PPLs)
Advanced Robotic Techniques and Rapid Onsite Evaluation for Minimally Invasive Diagnosis and Next-Generation Sequencing.
ARTEMIS is a multicenter randomized controlled trial. The goal is to understand whether rapid onsite evaluation during robotic assisted bronchoscopy improves the diagnostic performance of the procedure or not.
- Trial name
- ARTEMIS (NCT07685977)
- Testing
- Rapid onsite evaluation
- Where
- 8 sites in United States
- Volunteers
- 400 people
- Sponsor
- Vanderbilt University Medical Center
Lung Cancer
EBUS-GS-TBLB With or Without Fluoroscopy for the Diagnosis of PPLs
The purpose of this study is to evaluate the efficacy and safety of endobronchial ultrasound-guide sheath(EBUS-GS) for the diagnosis of peripheral pulmonary lesions (PPLs) without radiographic fluoroscopy.
- Trial name
- NCT01895166
- Testing
- EBUS-GS, X-ray
- Where
- China
- Volunteers
- 100 people
- Sponsor
- Shanghai Chest Hospital
Peripheral Pulmonary Lesions (PPLs), Pulmonary Nodules
Comparative Study of Rotational Cryobiopsy Needle and Automated Biopsy Needle in Transthoracic Biopsy Diagnosing Peripheral Pulmonary Lesions
This study aims to systematically compare the diagnostic efficacy, specimen quality, and complication rates of the cryobiopsy needle technique(CassiII rotational core biopsy) versus the automated biopsy technique in the biopsy of…
- Trial name
- NCT07772479
- Testing
- CassiII rotational core biopsy, Automated biopsy
- Where
- China
- Volunteers
- 308 people
- Sponsor
- Beijing Chao Yang Hospital
Lung Cancer
UTB-VBN-EBUS With or Without Fluoroscopy for the Diagnosis of PPLs
The purpose of this study is to evaluate the feasibility,efficacy and safety of ultrathin bronchoscopy(UTB) combined with virtual bronchoscopic navigation(VBN) and endobronchial ultrasound(EBUS) for the diagnosis of peripheral…
- Trial name
- NCT02664259
- Testing
- VBN, EBUS, X-ray
- Where
- China
- Volunteers
- 126 people
- Sponsor
- Shanghai Chest Hospital
Peripheral Pulmonary Lesions
Feasibility of Thin Cp-EBUS Scope BF-UC290F for the Diagnosis of PPLs
The purpose of the study is to evaluate the diagnostic value and safety of Thin Convex Probe Endobronchial Ultrasound (TCP-EBUS) Scope for peripheral pulmonary lesions (PPLs)
- Trial name
- NCT05512533
- Testing
- Linear Ultrasound Bronchoscope BF-UC290F (Olympus)
- Where
- China
- Volunteers
- 31 people
- Sponsor
- Shanghai Chest Hospital
Endobronchial Ultrasound
EBUS Image Features in the Diagnosis of PPLs
The study is aimed to evaluate the sensitivity, specificity, positive predictive value, negative predictive value and accuracy rate of endobronchial ultrasound (EBUS) image features in diagnosing peripheral pulmonary lesions…
- Trial name
- NCT03575715
- Testing
- EBUS
- Volunteers
- 200 people
- Sponsor
- Shanghai Chest Hospital
Lung Ground-Glass Opacity
GGO-dominant PPLs Diagnosis Using CLE and ssRAB-guided Cryobiopsy
The purpose of the study is to evaluate the diagnostic performance and safety of cryobiopsy for ground-glass opacity (GGO)-dominant peripheral pulmonary lesions (PPLs) under the guidance of shape-sensing robotic-assisted…
- Trial name
- NCT06910046
- Testing
- CLE and ssRAB-guided cryobiopsy
- Where
- China
- Volunteers
- 119 people
- Sponsor
- Shanghai Chest Hospital