Clinical trials: Noninvasive Ventilation
Inadequate; Pulmonary Ventilation, Newborn, Infant, Very Low Birth Weight
Nasal Noninvasive NAVA in the Very Low Birth Weight Infant
The purpose of this study is to determine if a new type of mechanical ventilation, or breathing machine (called neurally adjusted ventilatory assist or NAVA), will provide additional support to infants who were born prematurely.
- Trial name
- NCT01785563
- Testing
- Nasal NIV-NAVA
- Where
- 2 sites in United States
- Volunteers
- 40 people
- Sponsor
- Tarah T Colaizy
Hypoxia
Preoxygenation With Nasal Cannula and Noninvasive Positive Pressure Ventilation
This is a prospective randomized cross over study of healthy volunteers comparing end-tidal oxygen concentration among subjects undergoing continuous positive airway pressure ventilation via a noninvasive ventilation (NIV) mask…
- Trial name
- NCT03093662
- Testing
- Ventilation with nasal cannula, Ventilation without nasal cannula
- Where
- United States
- Volunteers
- 37 people, healthy volunteers welcome
- Sponsor
- Brooke Army Medical Center
Brain Injuries, Traumatic
Noninvasive Neuromodulation for Treatment of Symptoms Due to Mild or Moderate Traumatic Brain Injury
The investigators hypothesis is that electrical stimulation to the tongue that directly stimulates two cranial nerve nuclei (Trigeminal and Facial Nerve Nuclei), will excite neural impulses to the brainstem and cerebellum.
- Trial name
- NCT02158494
- Testing
- Balance and Gait Training using neurostimulation modulation.
- Where
- United States
- Volunteers
- 44 people
- Sponsor
- University of Wisconsin, Madison
Nocturnal Hypoventilation, Neuromuscular Disease
Autotitrating Versus Standard Non-invasive Ventilation (NIV) in Newly Diagnosed Patients
The aim of the study is to compare the efficacy and tolerance of autotitrating non-invasive ventilation (NIV) versus standard NIV in patients with newly diagnosed nocturnal hypoventilation who have never experienced nocturnal…
- Conditions
- Nocturnal Hypoventilation, Neuromuscular Disease, Chest Wall Disorder
- Trial name
- NCT00901485
- Testing
- AutoVPAP, VPAPIIIST-A
- Where
- United Kingdom
- Volunteers
- 23 people
- Sponsor
- ResMed
Noninvasive Ventilation, Respiratory Insufficiency
A Feasibility Study Evaluating the Use of a Non-invasive Ventilation Mask
Evaluate the clinicians assessment of the use of an oro-nasal mask during non-invasive ventilation (non-intubated) with a feasibility study.
- Trial name
- mask (NCT02383719)
- Testing
- Oro-nasal Mask
- Volunteers
- 18 people
- Sponsor
- Convergent Engineering, Inc.
COPD
Vector Engineering Clinical
This study aimed to validate a novel automatic non-invasive ventilation (NIV) mode that continuously adjusts expiratory positive airway pressure (EPAP) to the lowest value that abolishes tidal expiratory flow limitation (EFL).
- Trial name
- NCT04725500
- Testing
- Auto-Titrating EPAP
- Where
- 2 sites in United States
- Volunteers
- 42 people
- Sponsor
- Philips Clinical & Medical Affairs Global
Surgical Patients, Pulmonary Complication
Prophylactic Noninvasive Ventilation in vs Postoperative Standard Care in High Risk Patients According to ARISCAT Score
Postoperative pulmonary complications are one of the most common complications after surgery. Noninvasive ventilation has been proposed post-operatively to prevent postoperative pulmonary complications.
- Trial name
- ANTICIPUSC (NCT03629431)
- Testing
- Prophylactic non-invasive ventilation, postoperative standard care
- Where
- 3 sites in France
- Volunteers
- 266 people
- Sponsor
- Institut Cancerologie de l'Ouest
CO2 Clearance, Mask Comfort
Noninvasive Ventilation Masks Carbon Dioxide Clearance in Normal Volunteers
This study will be a randomized crossover trial that will be conducted at Rush University. The study will be conducted with 20 healthy volunteers who will be placed on ICU ventilator operating in the NIPPV mode.
- Conditions
- CO2 Clearance, Mask Comfort, Rebreathing Exhaled Gas
- Trial name
- NCT03882723
- Testing
- Evaluated 4 masks used for NIV with mechanical ventilators
- Where
- United States
- Volunteers
- 8 people, healthy volunteers welcome
- Sponsor
- Rush University Medical Center
Intubated Infants Were Intend to Extubation Using Noninvasive Ventilation Strategies
A Trial Comparing Noninvasive Ventilation Strategies in Preterm Infants Following Extubation
Respiratory distress syndrome (RDS) is the main cause of respiratory failure in preterm neonates, its incidence varying from 80% to 25% depending on gestational age.When optimal prenatal care is provided, the best approach to…
- Trial name
- NCT03181958
- Testing
- NHFOV, NCPAP, NIPPV
- Where
- China
- Volunteers
- 1,493 people
- Sponsor
- Daping Hospital and the Research Institute of Surgery of the Third Military Medical University
Hypercapnia, Respiratory Insufficiency
Extracorporeal Lung Assist to Avoid Intubation in Patients Failing Noninvasive Ventilation for Hypercapnic ARF
The study´s intention is to evaluate the feasibility, safety and effectiveness of a pump driven extracorporeal device for removal of carbon dioxide from the blood in oder to avoid intubation and invasive mechanical ventilation in…
- Trial name
- ECLAIR (NCT01784367)
- Testing
- vv-ECCO2R (Novalung GmbH, Germany)
- Where
- Germany
- Volunteers
- 50 people
- Sponsor
- Universitätsklinikum Hamburg-Eppendorf
Chronic Obstructive Pulmonary Disease
Effects of the Breathe Technologies Ventilation System in Subjects With Chronic Obstructive Pulmonary Disease
Pilot study in 15 stable male subjects with severe-to-very severe Chronic Obstructive Pulmonary Disease (COPD) to evaluate the effects of short term use of the Breathe Technologies noninvasive open ventilation (NIOV) system on…
- Trial name
- NCT01372462
- Testing
- NIOV - Room Air, NIOV - Oxygen, Nasal Cannula Oxygen
- Where
- United States
- Volunteers
- 15 people, healthy volunteers welcome
- Sponsor
- Breathe Technologies, Inc.
Apnea of Prematurity
A Comparison of Non-invasive Ventilation Methods Used to Prevent Endotracheal Intubation Due to Apnea in Very Low Birth Weight Infants
The purpose of this study is to determine whether nasal intermittent positive pressure ventilation (NIPPV) reduces the need for endotracheal intubation in very low birth weight infants with persistent apnea who fail nasal…
- Trial name
- NCT03298035
- Testing
- NCPAP as mode for apnea prevention, NIPPV as rescue mode for apnea prevention
- Where
- United States
- Volunteers
- 19 people
- Sponsor
- The University of Texas Health Science Center, Houston
Respiratory Insufficiency, Respiratory Failure
Cross-over Comparison of the V60 System to Other Bi-Level Noninvasive Ventilators
The purpose of this study is to compare a new noninvasive ventilator to existing ventilators already used for patient care.
- Trial name
- NCT00817804
- Testing
- Use of the V60 Mask Ventilator
- Where
- Canada
- Volunteers
- 3 people
- Sponsor
- Respironics, California, Inc.
Neonatal Respiratory Distress Syndrome, Extremely Low Birth Weight Infant (ELBW)
Effective Approaches & Strategies to Ease Off Nasal CPAP In Preterm Infants
Though Nasal Continuous Positive Airway Pressure (NCPAP) is a commonly used form of non-invasive neonatal respiratory support, the optimal method of weaning off NCPAP is not well established.
- Conditions
- Neonatal Respiratory Distress Syndrome, Extremely Low Birth Weight Infant (ELBW), BronchoPulmonary Dysplasia
- Trial name
- EASEOFFNCPAP (NCT02819050)
- Testing
- NCPAP
- Volunteers
- 80 people
- Sponsor
- Lundquist Institute for Biomedical Innovation at Harbor-UCLA Medical Center
Chronic Lung Disease of Prematurity, Bronchopulmonary Dysplasia
Relationship Between EIT and Respiratory Status in Very Preterm Infants
Electrical Impedance Tomography (EIT) is a non-invasive imaging technique that can measure lung function in real time. This study will follow premature infants to see if EIT can help predict which infants will be successful in…
- Conditions
- Chronic Lung Disease of Prematurity, Bronchopulmonary Dysplasia, Premature Lungs
- Trial name
- NCT06609135
- Testing
- Sentec LuMon Device (EIT system), Sentec Digital Monitoring System (transcutaneous CO2 monitor)
- Where
- United States
- Volunteers
- 20 people
- Sponsor
- Lawrence Rhein
Chronic Respiratory Failure
Implementation of Nasal Non-Invasive Ventilation With a RAM Cannula in the Inpatient /Outpatient Setting
The purpose of this study is to implement a standardized protocol to initiate nasal non-invasive ventilation with RAM nasal cannula (NIV/RAM-NC) with Trilogy mechanical ventilator at Children Memorial Hospital inpatient and…
- Trial name
- NCT03473171
- Testing
- Nasal non-invasive ventilation with RAM cannula
- Where
- United States
- Volunteers
- 5 people
- Sponsor
- The University of Texas Health Science Center, Houston
Bronchopulmonary Dysplasia
Comparison of Classification Standards of Bronchopulmonary Dysplasia (BPD) in Premature Infants
Bronchopulmonary dysplasia of premature infants is a common respiratory disease in premature infants. Long-term complications such as recurrent respiratory infection and abnormal lung function may occur in the survivors, and may…
- Trial name
- NCT04184648
- Testing
- no interventions
- Where
- China
- Volunteers
- 322 people
- Sponsor
- Wang Jianhui
Acute Respiratory Distress Syndrome, Shock
Non-Invasive Ventilation Via a Helmet Device for Patients Respiratory Failure
The objective of our study is to evaluate the efficacy of helmet ventilation as compared with Face mask in patients with respiratory failure.
- Conditions
- Acute Respiratory Distress Syndrome, Shock, Ventilatory Failure, Cardiogenic Pulmonary Edema
- Trial name
- NCT01680783
- Testing
- Non invasive ventilation using a helmet hyperbaric device, Noninvasive ventilation via facemask
- Where
- United States
- Volunteers
- 83 people
- Sponsor
- University of Chicago
Acute Respiratory Failure
High Flow Therapy for the Treatment of Respiratory Failure in the ED
The overall objective of this study is to determine if Vapotherm high flow nasal cannula therapy (HFT), when used to treat respiratory failure in the ED, is at least equivalent to the current standard of care for non-invasive…
- Trial name
- NCT02236559
- Testing
- Noninvasive positive pressure ventilation (NIPPV), Vapotherm
- Where
- 5 sites in United States
- Volunteers
- 204 people
- Sponsor
- Vapotherm, Inc.
Chronic Obstructive Pulmonary Disease, Noninvasive Ventilation
Determination of the Prevalence and Severity of Expiratory Flow Limitation in Chronic Obstructive Pulmonary Disease Patients
Expiratory Flow Limitation (EFL) occurs when the airways become compressed, which usually results when the pressure outside the airway exceeds the pressure inside the airway.
- Trial name
- NCT03851510
- Testing
- Vector ventilator, Resmon Pro
- Where
- United States
- Volunteers
- 57 people
- Sponsor
- Philips Respironics