Clinical trials: Intubation
Intubation, Cardiovascular Surgical Procedure
Reducing Reintubation Risk in High-Risk Cardiac Surgery Patients With High-Flow Nasal Cannula
The iCAN trial is a pragmatic randomized controlled trial that aims to test the hypothesis that HFNC versus usual care oxygenation strategies applied immediately after initial extubation after cardiac surgery decreases the…
- Trial name
- NCT04782817
- Testing
- Recommendation for high flow nasal cannula oxygen therapy order set, Provider choice usual care order set
- Where
- United States
- Volunteers
- 3,568 people
- Sponsor
- Vanderbilt University Medical Center
Respiratory Failure
Safety and Efficacy of Endotracheal Intubation Using Glidescope Video-Laryngoscope
The safety and efficacy of a video-laryngoscope as a primary intubation tool in urgent endotracheal intubation of critically-ill patients has not been well-described in the literature.
- Trial name
- NCT01683526
- Testing
- Direct laryngoscopy, Video laryngoscopy (Glidescope)
- Where
- United States
- Volunteers
- 117 people
- Sponsor
- Beth Israel Medical Center
Sore-throat, Dysphonia
No Post Intubation Laryngeal Symptoms
The purpose of the study is to test a novel endotracheal tube support device that reduces pressure of the tube on the voice box for prevention of post intubation laryngeal symptoms including sore throat, change in voice and…
- Conditions
- Sore-throat, Dysphonia, Dysphagia, Intubation Complication
- Trial name
- No-PILS (NCT05383417)
- Testing
- EndoClip
- Where
- United States
- Volunteers
- 100 people, healthy volunteers welcome
- Sponsor
- University of California, San Diego
Resuscitation
Newborn Ventilation in the Delivery Room: Could it be Improved With a T-piece Resuscitator?
A multicenter cross-over cluster randomized controlled trial protocol study in newborn infants ≥ 26 weeks gestational age requiring assisted ventilation (positive pressure ventilation [PPV]) for resuscitation in the delivery room…
- Trial name
- NCT00443118
- Testing
- T-piece resuscitator Neopuff TM, Self Inflating Bag with PEEP, Self Inflating Bag without PEEP
- Where
- 11 sites in United States, Argentina and 3 more
- Volunteers
- 1,032 people
- Sponsor
- Edgardo Szyld
Intubation; Difficult
I-gel Versus Classic-Laryngeal Mask Airway (C-LMA) as a Conduit for Tracheal Intubation Using Ventilating Bougie
Supraglottic Airway devices(SGAs) like I-Gel and C-LMA ( classic laryngeal mask airway ) have been used as a conduit for tracheal intubation using ventilating bougie.
- Trial name
- NCT02566135
- Testing
- Tracheal Intubation using I-gel and ventilating bougie, Tracheal Intubation using C-LMA and ventilating bougie
- Volunteers
- 58 people, healthy volunteers welcome
- Sponsor
- Medical College Baroda
Intubation
Stylet Angle for McGrath Videolaryngoscopy
The McGrath videolaryngoscope (VL) provides excellent laryngoscopic views, but directing an endotracheal tube is not easy, so routine using of stylet is recommended.
- Trial name
- NCT03000088
- Testing
- intubate with 60° angled stylet
- Volunteers
- 140 people
- Sponsor
- Ajou University School of Medicine
Airway Morbidity
Endotracheal Tube Versus Laryngeal Mask Airway for Esophagogastroduodenoscopy
Esophagogastroduodenoscopy (EGD) is a relatively common procedure in pediatric patients undergoing evaluation for various gastrointestinal ailments.
- Trial name
- NCT01936662
- Testing
- LMA, ETT
- Where
- United States
- Volunteers
- 84 people
- Sponsor
- Indiana University
Intubation Intraesophageal
Effectiveness of Video System in Improving Learning of Tracheal Intubation Using Standard Laryngoscopy Among Novices
The use of the video laryngoscope to teach laryngoscopy will improve the performance of tracheal intubation done by novices because it will allow a shared view of the airway leading to a better feedback from the trainer to the…
- Trial name
- NCT01080118
- Testing
- Airtraq, Control group, taught with a standard Macintosh laryngoscope
- Where
- United States
- Volunteers
- 90 people
- Sponsor
- Northwestern University
Anesthesia, Airway
Comparison of 3 Direct Laryngoscopes for Tracheal Intubation in Patients Undergoing Lumbar Spine Surgery
Hypothesis The use of Macintosh blade sized #3.5 (vs Macintosh size #3) would reduce the time required to achieve successful tracheal intubation and improve the glottic view.
- Trial name
- NCT02955511
- Testing
- Blade MAC size 3, Blade MAC size 3.5, Inscope Blade size 3.5
- Where
- United States
- Volunteers
- 5 people
- Sponsor
- Cedars-Sinai Medical Center
Endotracheal Intubation
Comparison of 2 Laryngoscopes for Endotracheal Intubation in Children Younger Than 2 Years Old
This is a prospective randomized clinical study to be performed in pediatric patients under the age of 2 years who are undergoing surgical procedures requiring endotracheal intubation.
- Trial name
- NCT01488370
- Testing
- Endotracheal intubation
- Where
- 2 sites in United States
- Volunteers
- 65 people
- Sponsor
- Loma Linda University
Anesthesia Intubation Complication
Tracheal Palpation of Sliding Cuff to Assess Endotracheal Tube Location
Correct endotracheal tube (ETT) placement is important. Proper ETT position is achieved when the distal tip is in mid-trachea with the head in neutral alignment.
- Trial name
- NCT02502461
- Testing
- cuff palpation
- Where
- Canada
- Volunteers
- 90 people
- Sponsor
- University of Saskatchewan
Intubation, Intratracheal
Force of Endotracheal Tube Extubation; Esophagus vs. Trachea
A study of a new approach to determining if, following endotracheal intubation, the endotracheal tube (ETT) is in the trachea or the esophagus.
- Trial name
- TETT (NCT03480425)
- Testing
- Measuring extubation force
- Where
- Canada
- Volunteers
- 11 people
- Sponsor
- University of Saskatchewan
Intubation; Difficult
Investigation of the Effectiveness of Sevoflurane Anaesthesia in Difficult to Intubate Egyptian Patients
The purpose of this study was to record the effectiveness of sevoflurane for intubation in Egyptian, non-obstetric, difficult to intubate (DTI) patients undergoing surgery in regards to the rate of intubation success.
- Trial name
- NCT01749631
- Volunteers
- 97 people
- Sponsor
- AbbVie (prior sponsor, Abbott)
Critically Ill Patients
Esketamine Induction Intubation in ICU Patients.
Intubation in the intensive care unit (ICU) is usually an emergency. Pathophysiological changes such as shock, respiratory failure, and metabolic acidosis in critically ill patients can significantly increase the incidence of…
- Trial name
- NCT05464979
- Testing
- Esketamine Hydrochloride 28 Mg in 0.2 mL NASAL SOLUTION [Spravato], midazolam, fentanyl
- Where
- China
- Volunteers
- 80 people
- Sponsor
- Union Hospital, Tongji Medical College, Huazhong University of Science and Technology
Intubation Complication
Suction Catheter as a Guide for Nasotracheal Intubation Under General Anesthesia
The goal of this clinical trial to study the efficacy of suction catheter guided technique and conventional technique during nasotracheal intubation.
- Trial name
- NCT05717907
- Testing
- suction catheter
- Where
- Thailand
- Volunteers
- 52 people
- Sponsor
- Mahidol University
Pyloric Stenosis, Intubation, Pediatric
Conventional Direct Laryngoscopy Vs. Video Laryngoscopy With The C-MAC For Pyloromyotomy
The purpose of this study is to compare two different ways of placing breathing tubes for surgery. Both ways are used currently to place breathing tubes and are safe and effective.
- Trial name
- NCT02775214
- Testing
- Video Laryngoscopy
- Where
- United States
- Volunteers
- 62 people
- Sponsor
- Indiana University
Respiratory Failure
The Use of the GlideScope Ranger in Pediatric Critical Care Transport
This study seeks to assess the role of the GlideScope Ranger video laryngoscope in facilitating successful neonatal/pediatric intubation by pediatric critical care transport teams.
- Trial name
- NCT01054183
- Testing
- GlideScope Ranger Intubation, Direct Laryngoscopy
- Where
- United States
- Volunteers
- 22 people
- Sponsor
- Akron Children's Hospital
Infant, Newborn, Diseases, Other Preterm Infants
Surfactant Positive Airway Pressure and Pulse Oximetry Trial
This study compared the use of continuous positive airway pressure initiated at birth with the early administration of surfactant administered through a tube in the windpipe within 1 hour of birth for premature infants born at 24…
- Conditions
- Infant, Newborn, Diseases, Other Preterm Infants, Infant, Small for Gestational Age, Premature Birth
- Trial name
- SUPPORT (NCT00233324)
- Testing
- Surfactant, Continuous Positive Airway Pressure (CPAP), Supplemental oxygen with target saturation of 85 to 89%
- Where
- 22 sites in United States
- Volunteers
- 1,316 people
- Sponsor
- NICHD Neonatal Research Network
Airway
Comparison of GlideScope-Specific Rigid Stylet to Standard Malleable Stylet for GlideScope Intubation by Novice Operators
Patients presenting for elective surgery requiring tracheal intubation will be randomized to one of two different endotracheal tube (ETT) stylets.
- Trial name
- NCT00884754
- Testing
- GlideScope rigid stylet
- Where
- Canada
- Volunteers
- 60 people
- Sponsor
- London Health Sciences Centre Research Institute OR Lawson Research Institute of St. Joseph's
Intubation; Difficult
Nasotracheal Intubation Using Shikani Optical Stylet
Difficult airways is still a challenging issue for the anesthesiologists in spite of the development of various techniques.Shikani optical stylet(SOS), combining the features of fiberoptic bronchoscope and a lightwand, has been…
- Trial name
- SOS (NCT00963677)
- Testing
- Nasotracheal Intubation through seeing optical stylet (SOS)
- Where
- China
- Volunteers
- 55 people
- Sponsor
- Central South University