A study testing Blade MAC size 3, Blade MAC size 3.5 and Inscope Blade size 3.5 in people with Anesthesia and Airway, run by Cedars-Sinai Medical Center at 1 site in United States.

Terminated

Stopped early. The study ended before it was planned to and will not resume.

Official record
Search all trials

Trial summary

Hypothesis The use of Macintosh blade sized #3.5 (vs Macintosh size #3) would reduce the time required to achieve successful tracheal intubation and improve the glottic view. Study objective The purpose of this research study is to compare 3 different laryngoscope blades (sizes: 3.5, 3.5 and 3) and see if the blades… Read more about this study

Who is it for?
Ages 18 to 80 years
Conditions the study is for
Anesthesia, Airway
What is being tested?
Blade MAC size 3, Blade MAC size 3.5 and Inscope Blade size 3.5
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
5 participants
Where
1 siteUnited States
Study dates
2 Jan 2018to 15 Sep 2021
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 80 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult
  1. Inclusion Criteria:
  2. Patients undergoing lumbar spine surgery procedures under general anesthesia
  3. Patients with a documented BMI of <35
  4. Willingness and ability to sign an informed consent document
  5. 18 - 80 years of age of either gender
  6. American Society of Anesthesiologists (ASA) physical status classification I - II or III
  7. Exclusion Criteria:
  8. Patients who are deemed to be such a significant of an airway risk that they necessitate awake fiberoptic intubation or a difficult tracheal intubation is anticipated
  9. Patients with history of difficult intubation
  10. Patients with oxygen saturation less than 95% at room air
  11. Patients with history facial abnormalities, oral-pharyngeal cancer or reconstructive surgery
  12. Any pathologies of the mouth, pharynx or larynx, or the access to the airway is restricted
  13. Patients with Immobilized cervical spine, or history of cervical abnormalities
  14. Patients with a history of uncontrolled gastroesophageal reflux, hiatus hernia or diabetic gastroparesis
  15. Any coagulation disorder
  16. Pregnant patients
  17. Emergency surgeries
  18. Any other conditions or use of any medication which may interfere with the conduct of the Study

Trial locations and contacts

1 site in 1 country.

United States1 site
  • Cedars Sinai Medical Center

    Los Angeles, California, 90048

Other trials in United States

About this study

Official title: Comparison of 3 Direct Laryngoscopes: Inscope DL Blade Size 3.5 and DL Blade 3.5 Sun-Med GreenLine®/D™ to DL Blade 3 Sun-Med GreenLine®/D™ for Tracheal Intubation in Patients Undergoing Lumbar Spine Surgery, a Prospective Randomized Study

Hypothesis The use of Macintosh blade sized #3.5 (vs Macintosh size #3) would reduce the time required to achieve successful tracheal intubation and improve the glottic view.

Study objective The purpose of this research study is to compare 3 different laryngoscope blades (sizes: 3.5, 3.5 and 3) and see if the blades size 3.5 will reduce the time required to achieve successful tracheal intubation and improve the physician's view of the glottis compared to the standard direct laryngoscope using the blade size 3, in patients undergoing lumbar surgery.

Read more

Primary end point: time to achieve successful tracheal intubation.

Secondary end points: glottic view at intubation, number of intubation attempts and effectiveness of the integrated suction in the Inscope Direct Laryngoscope.

Read the detailed description

Laryngoscopy is a common medical procedure used during elective and emergency intubations. The procedure is performed with either a direct or video laryngoscope with the device selected dependent on tool availability, provider (i.e. anesthesiologist, emergency physician, ENT physician, paramedic, etc.) preference, patient characteristics, and intubation difficulty. The direct laryngoscope technique involves a line-of-sight view from the patient's mouth to vocal cords along the blade of the scope. The direct laryngoscopy technique is the oldest technique associated with intubation. However, despite continuous improvements to direct laryngoscope size and shape since its inception in the late 19th century, no improvement yet addresses one major problem with airway visualization: the provider will experience a difficult intubation if liquids (i.e. gastric content, blood, mucus, etc.) obstruct the view.

The Sun-Med GreenLine®/D™ Macintosh is a line of disposable direct Macintosh laryngoscopes. It features a stainless steel blade and polycarbonate light-pipe to direct light into the airway. The handle, with integrated batteries and LED light, and blade are separately packaged prior to use. The GreenLine®/D™ Macintosh line is available in the standard sizes (0, 1, 2, 3, 4) and a new size built to improve blade sizing for many adults 3.5 when a Mac 3 is too short, but a Mac 4 is too large. The GreenLine®/D™ Macintosh does not feature integrated suction.

The Inscope Direct Laryngoscope (developed by Inscope Medical Solutions) is a new disposable direct laryngoscope with two integrated and controllable (flow on/off) suction pathways. By integrating controllable suction with two independent pathways into the laryngoscope, the provider is able to select the primary (blade tip) suction pathway to clear secretions ahead of the laryngoscope and the secondary (at blade mid-length, below blade) to prevent and clear fluids that may re-accumulate during the procedure. Integrating the suction into the device prevents the common current practice of "juggling" the current suction catheter and endotracheal (breathing) tube in one hand while holding the patient's airway open with the other hand. While the incidence of aspiration of fluids into the lungs as a result of poor airway fluid management is low, the outcomes associated with this complication are very poor.

The Inscope Direct Laryngoscope has been developed as a Macintosh 3.5 sized blade to meet the size requirements of the majority of patients. This assumption is backed up by a trend among disposable direct laryngoscope manufacturers toward the 3.5 blade size, with at least 5 creating a 3.5 blade, including Teleflex, Sun-Med, Flexicare, Mercury Medical, and Curaplex.

This study will compare the Inscope Direct Laryngoscope (blade size 3.5) with the currently used standard single-use Sun-Med Greenline/D Macintosh laryngoscopes DL-blade mac size and Sun-Med Greenline/D-blade size 3.5.

All Direct Laryngoscopes are considered a Class I exempt device by the FDA. Because the risks associated with laryngoscopes are well known and documented, they are considered a non-significant risk device for studies involving humans.

Conditions
Anesthesia, Airway
Being tested
Blade MAC size 3, Blade MAC size 3.5, Inscope Blade size 3.5

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Blade MAC size 3Device

    Patient will be intubated using the DL- Blade MAC size 3

  • Blade MAC size 3.5Device

    Patient will be intubated using the DL- Blade MAC size 3.5

  • Inscope Blade size 3.5Device

    Patient will be intubated using the Inscope Blade size 3.5

Study groups in NCT02955511
Study groupRoleWhat they receive
Blade MAC size 3Active comparatorPatient will be intubated using a: Direct Laryngoscope (DL) Mac size 3 (Sun-Med GreenLine®/D™ Macintosh)
Receives: Device: Blade MAC size 3
Blade MAC size 3.5Active comparatorPatient will be intubated using a: DL-blade mac size 3.5 (Sun-Med Greenline®/D™ Macintosh)
Receives: Device: Blade MAC size 3.5
Inscope Blade size 3.5ExperimentalPatient will be intubated using a: Inscope DL-blade size 3.5
Receives: Device: Inscope Blade size 3.5

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Intubation Time (Using a Stopwatch)

    Intubation Time:

    It is the time taken to intubate: from the initial insertion of the laryngoscope blade to the placement of the tracheal tube (approximately 3 minutes).

    An intubation attempt:

    It is defined as the insertion of the laryngoscope blade into a patient's mouth, with the objective of inserting an endotracheal tube into the trachea.

    Measured: up to 3 minutes

  2. Glottis Visualization POGO Score

    The percentage of the glottis visualized (POGO) score It represents the percentage of glottic opening seen; the score ranges from 0% when none of the glottis is seen to 100% when the entire glottis, including the anterior commissure, is seen.

    Measured: During intubation procedure, up to 1 minute

  3. Time From the Insertion of the Laryngoscope Blade to Confirm w/ CO2 Waveform

    The time following the initial insertion of the laryngoscope blade into the mouth to confirm w/ CO2 waveform

    Measured: During intubation procedure, up to 3 minutes

Secondary outcomes (2)
  1. Intubation Attempts

    An intubation attempt is defined as the insertion of the laryngoscope blade into a patient's mouth, with the objective of inserting an endotracheal tube into the trachea.

    The number of intubation attempts in each participant for successful tracheal intubation measured how many times the anesthesiologist attempted to place the tube into the trachea of each patient.

    Measured: 3 minutes

  2. Glottis Visualization Using Cormack Lehane

    Grade Description Approximate frequency Likelihood of difficult intubation

    1. Full view of glottis 68-74% <1%
    2. a Partial view of glottis 21-24% 4.3-13.4%

    2b Only posterior extremity of glottis seen or only arytenoid cartilages 3.3-6.5% 65-67.4% 3 Only epiglottis seen, none of glottis seen 1.2-1.6% 80-87.5% 4 Neither glottis nor epiglottis seen very rare

    Note:

    In the analysis of the data collected for 5 participants, there was no differentiation between "2a" and "2b" for a grade of "2."

    Measured: During intubation procedure, up to 1 minute

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted4 Nov 2016 (estimated)
  2. Study start2 Jan 2018
  3. Primary completion15 Sep 2021
  4. Study completion15 Sep 2021

Why it stopped: The blade used in the study was modified (changed) by the manufacturer, it does not longer exist.

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Screening
Allocation
Randomised
Intervention model
Factorial
Masking
Double blind
Who is masked
Participant, Outcomes assessor
Enrolment
5 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02955511
Sponsor's protocol ID
Pro00045198
Status last verified
Oct 2022
First submitted
2 Nov 2016
Last updated
19 Oct 2022
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study testing Blade MAC size 3, Blade MAC size 3.5 and Inscope Blade size 3.5 in people with Anesthesia and Airway, run by Cedars-Sinai Medical Center at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: stopped early, as of the sponsor's last update on 19 Oct 2022. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 19 Oct 2022). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Intubation Time (Using a Stopwatch) (time frame: up to 3 minutes). The study lists 3 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 19 Oct 2022.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in