Clinical trials: Endovascular Repair
Thoracoabdominal Aortic Aneurysm
Visceral Manifold Study for the Repair of Thoracoabdominal Aortic Aneurysms
The primary objective of the clinical investigation is to assess the use of the the Visceral Manifold Thoracoabdominal Aortic Aneurysms (VTAAA) stent graft system to repair thoracoabdominal aortic aneurysms in patients having…
- Trial name
- NCT03113383
- Testing
- Thoracoabdominal Aortic Aneurysm Repair
- Where
- United States
- Volunteers
- 4 people
- Sponsor
- Vanderbilt University Medical Center
Endoleak, Abdominal Aortic Aneurysm
Contrast Enhanced Ultrasound, Endoleak Detection Following EVAR v1.3
A single site cross-sectional comparison of paired diagnostic imaging modalities. This study will show the sensitivity and specificity of CEUS in detecting the various types of endoleaks, in comparison to tCTA, following EVAR.
- Trial name
- NCT02688751
- Testing
- time-resolved CT Angiography, Contrast Enhanced Ultrasound
- Where
- United Kingdom
- Volunteers
- 30 people
- Sponsor
- Liverpool University Hospitals NHS Foundation Trust
Type B Aortic Dissection
LSA Reconstruction With Laser Fenestration During the TEVAR
This study aims to evaluate the feasibility, effectiveness, and safety of in-situ laser-assisted fenestration on the left subclavian artery during the procedure of thoracic artery endovascular repair
- Trial name
- LLTEVAR (NCT03845829)
- Testing
- In situ laser assisted fenestration
- Where
- China
- Volunteers
- 100 people
- Sponsor
- Shanghai Ninth People's Hospital Affiliated to Shanghai Jiao Tong University
Endovascular Repair of Infrarenal Abdominal Aortic Aneurysm Using Endovascular Stent Graft
Post-market European & Asian Registry to Evaluate the Minos™ Stent-Graft and Delivery System in Abdominal Aortic Aneurysm Treatment
The Minos™ Abdominal Aortic Stent-Graft and Delivery System is a medical device designed to treat abdominal aortic aneurysms using a minimally invasive procedure.
- Trial name
- PEARL (NCT07674173)
- Testing
- Implantation with Minos Stent graft
- Where
- 16 sites in China, Germany and 4 more
- Volunteers
- 200 people
- Sponsor
- Shanghai MicroPort Endovascular MedTech(Group)Co., Ltd
Abdominal Aortic Aneurysm, Juxtarenal Abdominal Aortic Aneurysm
Evaluation of Clinical Efficacy and Safety of Aortal Stent-Graft Created Using 3D Printing Technology
the comparison of physician-modified stent-graft created in 3D models versus custom-made devices in the treatment of complex abdominal aortic aneurysm
- Conditions
- Abdominal Aortic Aneurysm, Juxtarenal Abdominal Aortic Aneurysm, Pararenal Abdominal Aortic Aneurysm, Thoracoabdominal Aortic Aneurysm
- Trial name
- NCT06969729
- Testing
- Physician-Modified Fenestrated Stent-Graft (3D-Printed Template-Guided)
- Where
- Poland
- Volunteers
- 100 people
- Sponsor
- Samodzielny Publiczny Szpital Kliniczny nr 2 PUM
Juxtarenal Aortic Aneurysm, Pararenal Aneurysm
Comparison of Outcomes of Complex Abdominal Aortic Aneurysm Treatment
Background: Open repair remains the gold standard for fit patients with complex AAA. In the past decade, an evolution of devices, design, components, and delivery systems expanded the application of EVAR in these challenging…
- Trial name
- NCT04773223
- Testing
- Open surgery and complex EVAR due to AAA
- Where
- Serbia
- Volunteers
- 925 people
- Sponsor
- Clinical Centre of Serbia
Aortic Dissection, Distal Entry Tear
Guo&Amp;'s Distal Entry Tear Repair With WeFlow-EndoPatch System (Gallant Study)
A Multicenter, Randomized Controlled Study About the Safety and Efficacy of WeFlow-EndoPatch Aortic Endovascular Patch System manufactured by EndoNom Medtech (Hangzhou) Co., Ltd. for Chronic Aortic Dissection . (GALLANT Study)
- Trial name
- Gallant (NCT06945809)
- Testing
- WeFlow-EndoPatch Aortic Endovascular Patch System, Conventional Treatment group
- Where
- China
- Volunteers
- 216 people
- Sponsor
- Hangzhou Endonom Medtech Co., Ltd.
Vascular Aneurysm
EASYII - E-tegra Stent Graft System - Imaging Cohort
The objective of the study is to assess the stent stability and durability as well as the seal of the stent graft during the cardiac cycle and over time as well as to evaluate safety and clinical performance of the E-tegra Stent…
- Trial name
- EASYII (NCT05586503)
- Testing
- ECG-gated CTAs
- Where
- 4 sites in Netherlands
- Volunteers
- 25 people
- Sponsor
- JOTEC GmbH
Common Iliac Artery Aneurysm, Aorto Iliac Aneurysm
Assessment of GORE® EXCLUDER® IBE Plus Stent Graft Performance in Patients Undergoing Endovascular Iliac Revascularization
The IBE 25-05 study will be a prospective, non-randomized, multicenter, interventional two arm evaluation designed to assess the safety and effectiveness of the GORE® EXCLUDER® IBE Plus Stent Graft in patients with common iliac…
- Trial name
- NCT07304102
- Testing
- GORE® EXCLUDER® IBE Plus Stent Graft
- Volunteers
- 100 people
- Sponsor
- W.L.Gore & Associates
Endoleaks
Evaluation of Contrast-Enhanced Ultrasound to Detect Endoleaks After Endovascular Aortic Aneurysm Repair
This study will be a cross-sectional survey of interobserver variability associated with contrast enhanced ultrasound (CEUS) to detect endoleaks using computed tomographic angiography (CTA) as the practice standard.
- Trial name
- AAA CEUS (NCT01005212)
- Testing
- Definity
- Where
- 2 sites in United States
- Volunteers
- 20 people
- Sponsor
- E. Peden, MD
Abdominal Aortic Aneurysm
ALTo endogrAft Italian Registry
The aim of present study is to evaluate intraoperative, peri-operative, and post-operative results in patients treated by the ALTO stent graft (Endologix Inc.
- Trial name
- ALTAIR (NCT05234892)
- Testing
- ALTO endograft implantation
- Where
- 2 sites in Italy
- Volunteers
- 300 people
- Sponsor
- Gianmarco de Donato
Aortic Dissection, Left Subclavian Artery Occlusion
Endovascular Repair With In Situ nEedle feNestration of Left Subclavian Artery to Treat AoRtic Dissection(RISEN STAR):A Multicenter Prospective Trial.
Background: Aortic dissection (AD) is a common emergency in vascular surgery, which seriously threatens human life and health. The rupture of Stanford type B dissection is located in aortic arch and the dissection range is from…
- Conditions
- Aortic Dissection, Left Subclavian Artery Occlusion, Vascular Diseases, Interventional Therapy
- Trial name
- NCT05186181
- Testing
- In situ fenestration
- Where
- China
- Volunteers
- 217 people
- Sponsor
- First Affiliated Hospital of Zhejiang University
Thoracic Aortic Aneurysm, Thoracic Aortic Dissection
ENDOBARC-S Study: "Endovascular Branched Stent-grafts for Aortic ARCh Pathologies in Spain"
The ENDOBARC-S post-market clinical follow-up study is undertaken to evaluate the prevention of death related to aortic arch pathologies when treated by branch stent graft systems (Nexus stent-graft system®, Relay Branch® or…
- Conditions
- Thoracic Aortic Aneurysm, Thoracic Aortic Dissection, Stent-Graft Endoleak, Stent-Graft Stenosis
- Trial name
- NCT05309707
- Testing
- Endovascular exclusion
- Where
- Spain
- Volunteers
- 100 people
- Sponsor
- Vascular Investigation Network Spanish Society for Angiology and Vascular Surgery
Abdominal Aortic Aneurysm Without Rupture
The British Society of Endovascular Therapy ConformabLe EndoVascular Aneurysm Repair Registry
The purpose of the BSET-CLEVAR Registry is to collect device-specific performance outcomes of the GORE® EXCLUDER® Conformable AAA Endoprosthesis with ACTIVE CONTROL System (EXCC device) in routine clinical treatment of patients…
- Trial name
- BSET-CLEVAR (NCT03966521)
- Where
- 13 sites in United Kingdom
- Volunteers
- 105 people
- Sponsor
- Imperial College London
Coronary Artery Disease, Aortic Atherosclerotic Disease
Evaluation of the Strategy of "One-stop" Endovascular Treatment for Concomitant Coronary Artery Disease and Aortic Atherosclerotic Disease
The study is a prospective, randomized, controlled, exploratory trail to evaluate the strategy of "one-stop" endovascular treatment for concomitant coronary artery disease and aortic atherosclerotic disease.
- Trial name
- NCT03563768
- Testing
- One-stop strategy group
- Where
- China
- Volunteers
- 60 people
- Sponsor
- Chinese Academy of Medical Sciences, Fuwai Hospital
Critical Limb Ischemia
Registry of First-line Treatments in Patients With Critical Limb Ischemia
The principal research question is which treatment modality between open surgical, endovascular and conservative therapy is the most effective in terms of limb salvage, survival and reinterventions in patients with critical limb…
- Trial name
- CRITISCH (NCT01877252)
- Testing
- Surgical revascularization, Endovascular revascularization, No vascular intervention
- Where
- Germany
- Volunteers
- 1,200 people
- Sponsor
- St. Franziskus Hospital
Abdominal Aortic Aneurysm
Immediate Management of the Patient With Rupture : Open Versus Endovascular Repair
The purpose of this trial is to assess whether a strategy of endovascular repair (if aortic morphology is suitable, open repair if not) versus open repair reduces early mortality for patients with suspected ruptured abdominal…
- Trial name
- IMPROVE (NCT00746122)
- Testing
- Open repair, EVAR
- Where
- 30 sites in Canada, United Kingdom
- Volunteers
- 613 people
- Sponsor
- Imperial College London
Abdominal Aortic Aneurysms
A Multicenter, Open Label, Prospective, Non-Randomized Study Of INCRAFT™ In Subjects With AAA (INNOVATION)
This study is a multi-center prospective, open label, non-randomized investigation of INCRAFT™ in subjects with abdominal aortic aneurysms. The study will enroll up to 60 subjects in up to 7 sites in Germany and Italy.
- Trial name
- INNOVATION (NCT01106391)
- Testing
- Cordis AAA stent graft system "INCRAFT TM"
- Where
- Germany
- Volunteers
- 60 people
- Sponsor
- Cordis US Corp.
Distal Aortic Dissection, Dissection, Aortic Acute
ACute Uncomplicated Type b Aortic Dissection: Endovascular Repair vs. Best Medical Therapy
The purpose of the study is to conduct a randomized controlled trial comparing best medical therapy (BMT) alone to BMT with thoracic endovascular aortic repair (BMT+TEVAR) for uncomplicated acute type B aortic dissection.
- Conditions
- Distal Aortic Dissection, Dissection, Aortic Acute, Acute Type B Aortic Dissection (Uncomplicated)
- Trial name
- ACUTE-B (NCT02622542)
- Testing
- BMT+TEVAR, BMT
- Where
- 2 sites in United States
- Volunteers
- 436 people
- Sponsor
- The University of Texas Health Science Center, Houston
Aorto-iliac Aneurysms, Iliac Aneurysms
Zenith(R) Connection Endovascular Covered Stent Clinical Study
The Zenith(R) Connection Endovascular Covered Stent Clinical Study is a clinical investigation to study the safety and performance of the Zenith(R) Connection Endovascular Covered Stent in conjunction with the Zenith(R) Branch…
- Trial name
- NCT00893620
- Testing
- Zenith(R) Connection Endovascular Covered Stent with the Zenith® Branch Endovascular Graft-Iliac Bifurcation and Zenith Flex(R) AAA Endovascular Graft
- Where
- 4 sites in Germany, Hong Kong and 1 more
- Volunteers
- 1 people
- Sponsor
- Cook Group Incorporated