Malignant Liver TumorsNCT07916350
A Study of the Safety and Effectiveness of a Compound Steep-Pulse Therapy Apparatus for Malignant Liver Tumors
A study testing Compound Steep-Pulse Therapy Apparatus (HFMP-02) and Cool-tip RF Ablation System (CTRF220) in people with Malignant Liver Tumors, run by REMD Medical Technology at 1 site in China.
Trial summary
This prospective, multicenter, randomized, parallel-group, open-label, noninferiority study compares the safety and efficacy of the Compound Steep-Pulse Therapy Apparatus with radiofrequency ablation in adults with malignant liver tumors. Read more about this study
- Who is it for?
- Ages 18 to 80 years
- Conditions the study is for
- Malignant Liver Tumors
- What is being tested?
- Compound Steep-Pulse Therapy Apparatus (HFMP-02) and Cool-tip RF Ablation System (CTRF220)
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 181 participants
- Where
- 1 siteChina
- Study dates
- 28 Dec 2021to 6 Dec 2024
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 80 years
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- 1.Age ≥18 and ≤80 years, regardless of sex.
- 2.Diagnosed with a malignant liver tumor.
- 3.Child-Pugh class A or B liver function.
- 4.A single tumor ≤4 cm in diameter, or up to three tumor lesions, each with a maximum diameter ≤3 cm.
- 5.Willing to participate in the study and voluntarily provide written informed consent.
- 6.Expected survival >6 months.
Who cannot join
- 1.Severe dysfunction of major organs, such as the heart, lungs, or kidneys, that, in the investigator's judgment, would preclude tolerance of treatment.
- 2.Contraindications to general anesthesia.
- 3.Allergy to contrast agents used for CT or MRI.
- 4.Previous ablation of the target lesion. Newly developed lesions adjacent to a previously ablated target lesion may be eligible.
- 5.Imaging evidence of invasion of major blood vessels or bile ducts on liver CT, MRI, or other imaging examinations.
- 6.Severe coagulation abnormalities, defined as a platelet count <50 × 10⁹/L or prolongation of prothrombin time by >5 seconds.
Show all 14Show fewer
- 7.Uncorrectable refractory massive ascites or cachexia.
- 8.Severe portal hypertension or a history of esophageal variceal bleeding within the past month.
- 9.An implanted cardiac pacemaker or a metallic implant within 2.5 cm of the ablation zone.
- 10.A history of epilepsy.
- 11.A history of severe arrhythmia within the past month that could not be controlled with medication.
- 12.Pregnancy, breastfeeding, or plans to conceive during the study.
- 13.Participation in another drug or medical device trial without having exited that trial before enrollment.
- 14.Any other condition that, in the investigator's judgment, makes the patient unsuitable for participation in this clinical trial.
Trial locations and contacts
1 site in 1 country.
China1 site
Nortion Medical Technology Co., Ltd
Shanghai, Shanghai Municipality, 201318
About this study
Official title: A Prospective, Parallel-Group, Randomized, Controlled, Noninferiority, Multicenter Study Evaluating the Safety and Efficacy of a Compound Steep-Pulse Therapy Apparatus for Malignant Liver Tumors
This prospective, multicenter, randomized, parallel-group, open-label, noninferiority study compares the safety and efficacy of the Compound Steep-Pulse Therapy Apparatus with radiofrequency ablation in adults with malignant liver tumors. Eligible participants are randomly assigned in a 1:1 ratio to the test group or the control group using a web-based central randomization system, with stratification by tumor diameter and tumor type.
The primary outcome is the ablation success rate at 1 month after treatment, assessed by contrast-enhanced computed tomography or magnetic resonance imaging under blinded conditions. Secondary outcomes include ablation success at 3 months, complete ablation rates, tumor response, local recurrence-free rates, procedure-related complications, console operability, and system stability. Safety is evaluated through adverse events and laboratory assessments.
- Conditions
- Malignant Liver Tumors
- Being tested
- Compound Steep-Pulse Therapy Apparatus (HFMP-02), Cool-tip RF Ablation System (CTRF220)
- Keywords
- IRE, malignant liver tumors, randomized
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Compound Steep-Pulse Therapy Apparatus (HFMP-02)Device
The Compound Steep-Pulse Therapy Apparatus (Nortion, model HFMP-02) delivers microsecond-level, bipolar, high-intensity composite pulses to solid tumors to induce irreversible electroporation (IRE)-mediated cell death. In this trial it is used for local ablation of liver malignant tumors.
Cool-tip RF Ablation System (CTRF220)Device
The Cool-tip RF Ablation System (Covidien/Medtronic, model CTRF220) is a radiofrequency ablation generator indicated for coagulation and ablation of tissue during percutaneous, laparoscopic, and surgical procedures. In this trial it serves as the active comparator for local ablation of liver malignant tumors.
| Study group | Role | What they receive |
|---|---|---|
| High-Frequency Irreversible Electroporation (H-FIRE) | Experimental | Patients with liver malignant tumors in this arm receive local ablation using High-Frequency Irreversible Electroporation (H-FIRE) delivered by the Compound Steep-Pulse Therapy Apparatus (Nortion, model HFMP-02). Receives: Device: Compound Steep-Pulse Therapy Apparatus (HFMP-02) |
| Radiofrequency Ablation (RFA) | Active comparator | Patients with liver malignant tumors in this arm receive local ablation using Radiofrequency Ablation (RFA) delivered by the Cool-tip RF Ablation System (Covidien, model CTRF220). Receives: Device: Cool-tip RF Ablation System (CTRF220) |
What is being measured
The primary outcome is the main question the study is designed to answer.
Ablation success rate at 1 month after ablation
number of subjects in the group with complete ablation of the target lesion / total number of subjects in the group × 100%.
Measured: 1 month after ablation
Secondary outcomes (9)
Ablation success rate at 3 months after ablation
number of subjects in the group with complete ablation of the target lesion / total number of subjects in the group × 100%
Measured: at 3 months after ablation
Complete ablation rate
number of target lesions with complete ablation in the group / total number of target lesions in the group × 100%
Measured: At 1 month and 3 months after ablation
Disease control rate
Disease control rate (DCR) = number of subjects in the group with (CR + PR + SD) / number of subjects in the group × 100%
Assessment is performed using the mRECIST criteria:
- Complete response (CR): disappearance of any intratumoral arterial enhancement in all lesions.
- Partial response (PR): at least a 30% decrease in the sum of diameters of target lesions (with arterial-phase enhancement).
- Stable disease (SD): neither CR/PR nor PD.
- Progressive disease (PD): at least a 20% increase in the sum of diameters of target lesions (with arterial-phase enhancement), or appearance of new lesions.
Measured: At 3 months after ablation
Objective response rate
Objective response rate (ORR) = number of subjects in the group with (CR + PR) / number of subjects in the group × 100%
Measured: at 3 months after ablation
Complete response rate
Complete response rate (CR) = number of subjects in the group with CR / number of subjects in the group × 100%.
Measured: at 3 months after ablation
Local recurrence-free rate
Recurrence-free rate = number of recurrence-free cases / total number of treated cases × 100%.
Measured: at 1 month and 3 months after ablation
Incidence of procedure-related complications
number of cases with the complication / total number of cases × 100%
Measured: From the ablation procedure through 6 months after ablation
Console operability
Rated on three levels:
- Satisfactory: the interface is clear and easy to recognize, button and icon positions are reasonable, operating procedures are convenient, and parameter setting can be completed rapidly.
- Acceptable: the interface is recognizable, button and icon positions are basically reasonable, operating procedures can be mastered through ordinary training, and parameter setting can be completed within an acceptable time.
- Unsatisfactory: the interface is difficult to recognize, button and icon positions are disorganized, operating procedures are cumbersome, and parameter setting is difficult.
Measured: During the ablation procedure (Day 0)
System stability
Instrument stability is rated on three levels:
- Very stable: no instrument-related mechanical or electrical event occurred during the procedure and there was no adverse effect on the procedure.
- Stable: minor instrument-related mechanical or electrical events occurred during the procedure but did not affect the procedure.
- Unstable: frequent minor instrument-related mechanical or electrical events occurred during the procedure and affected the procedure.
Measured: During the ablation procedure (Day 0)
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted4 Nov 2026
- Study start28 Dec 2021
- Primary completion26 Jun 2024
- Study completion6 Dec 2024
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Malignant Liver TumorsStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Single blind
- Who is masked
- Outcomes assessor
- Enrolment
- 181 participants (actual)
Sponsor and investigators
- Lead sponsor
- REMD Medical Technology
- Sponsor type
- Industry (pharma, biotech, devices)
- Collaborators
- Beijing YouAn Hospital, Henan Cancer Hospital, Nanfang Hospital, Southern Medical University, Beijing Ditan Hospital, First Affiliated Hospital of Zhejiang University, The First School of Clinical Medicine of Binzhou Medical University, RenJi Hospital
- Responsible party
- Sponsor
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT07916350
- Sponsor's protocol ID
- REMD03
- Status last verified
- Oct 2026
- First submitted
- 23 Oct 2026
- Last updated
- 4 Nov 2026
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No: Individual participant data (IPD) will not be shared. The complete dataset contains sensitive clinical and imaging records, as well as device-specific proprietary parameters essential to the High-Frequency Irreversible Electroporation (H-FIRE) technology. Sharing these data externally poses significant risks to intellectual property protection. Furthermore, external sharing of de-identified IPD would require extensive compliance reviews to ensure adherence to patient privacy regulations and cross-border data security laws. Aggregate summary results will be reported in the primary publication.
Study at a glance
From the registry record, last updated by the sponsor on 4 Nov 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- A Prospective, Parallel-Group, Randomized, Controlled, Noninferiority, Multicenter Study Evaluating the Safety and Efficacy of a Compound Steep-Pulse Therapy Apparatus for Malignant Liver Tumors
- ClinicalTrials.gov ID
- NCT07916350
- Acronym / sponsor ID
- REMD03
- Conditions
- Malignant Liver Tumors
- Keywords
- IRE, malignant liver tumors, randomized
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 181 participants (actual)
- Lead sponsor
- REMD Medical TechnologyIndustry (pharma, biotech, devices)
- Collaborators
- Beijing YouAn Hospital, Henan Cancer Hospital, Nanfang Hospital, Southern Medical University, Beijing Ditan Hospital, First Affiliated Hospital of Zhejiang University, The First School of Clinical Medicine of Binzhou Medical University, RenJi Hospital
- Study start
- 28 Dec 2021 (actual)
- Primary completion
- 26 Jun 2024 (actual)
- Study completion
- 6 Dec 2024 (actual)
- First posted
- 4 Nov 2026 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
This prospective, multicenter, randomized, parallel-group, open-label, noninferiority study compares the safety and efficacy of the Compound Steep-Pulse Therapy Apparatus with radiofrequency ablation in adults with malignant liver tumors. Eligible participants are randomly assigned in a 1:1 ratio to the test group or the control group using a web-based central randomization system, with stratification by tumor diameter and tumor type.
The primary outcome is the ablation success rate at 1 month after treatment, assessed by contrast-enhanced computed tomography or magnetic resonance imaging under blinded conditions. Secondary outcomes include ablation success at 3 months, complete ablation rates, tumor response, local recurrence-free rates, procedure-related complications, console operability, and system stability. Safety is evaluated through adverse events and laboratory assessments.
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Single blind (outcomes assessor)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| High-Frequency Irreversible Electroporation (H-FIRE) | Experimental | Device: Compound Steep-Pulse Therapy Apparatus (HFMP-02)Patients with liver malignant tumors in this arm receive local ablation using High-Frequency Irreversible Electroporation (H-FIRE) delivered by the Compound Steep-Pulse Therapy Apparatus (Nortion, model HFMP-02). |
| Radiofrequency Ablation (RFA) | Active comparator | Device: Cool-tip RF Ablation System (CTRF220)Patients with liver malignant tumors in this arm receive local ablation using Radiofrequency Ablation (RFA) delivered by the Cool-tip RF Ablation System (Covidien, model CTRF220). |
Who may qualify
- Ages
- 18 to 80 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (6 listed)
- 1.Age ≥18 and ≤80 years, regardless of sex.
- 2.Diagnosed with a malignant liver tumor.
- 3.Child-Pugh class A or B liver function.
- 4.A single tumor ≤4 cm in diameter, or up to three tumor lesions, each with a maximum diameter ≤3 cm.
- 5.Willing to participate in the study and voluntarily provide written informed consent.
Key exclusion criteria (14 listed)
- 1.Severe dysfunction of major organs, such as the heart, lungs, or kidneys, that, in the investigator's judgment, would preclude tolerance of treatment.
- 2.Contraindications to general anesthesia.
- 3.Allergy to contrast agents used for CT or MRI.
- 4.Previous ablation of the target lesion. Newly developed lesions adjacent to a previously ablated target lesion may be eligible.
- 5.Imaging evidence of invasion of major blood vessels or bile ducts on liver CT, MRI, or other imaging examinations.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Compound Steep-Pulse Therapy Apparatus (HFMP-02)The Compound Steep-Pulse Therapy Apparatus (Nortion, model HFMP-02) delivers microsecond-level, bipolar, high-intensity composite pulses to solid tumors to induce irreversible electroporation (IRE)-mediated cell death. In this trial it is used for local ablation of liver malignant tumors. | Device | High-Frequency Irreversible Electroporation (H-FIRE) |
| Cool-tip RF Ablation System (CTRF220)The Cool-tip RF Ablation System (Covidien/Medtronic, model CTRF220) is a radiofrequency ablation generator indicated for coagulation and ablation of tissue during percutaneous, laparoscopic, and surgical procedures. In this trial it serves as the active comparator for local ablation of liver malignant tumors. | Device | Radiofrequency Ablation (RFA) |
Primary outcome
Ablation success rate at 1 month after ablation
Time frame: 1 month after ablation
number of subjects in the group with complete ablation of the target lesion / total number of subjects in the group × 100%.
9 secondary outcomes
Ablation success rate at 3 months after ablation
Time frame: at 3 months after ablation
Complete ablation rate
Time frame: At 1 month and 3 months after ablation
Disease control rate
Time frame: At 3 months after ablation
Objective response rate
Time frame: at 3 months after ablation
Complete response rate
Time frame: at 3 months after ablation
Local recurrence-free rate
Time frame: at 1 month and 3 months after ablation
Incidence of procedure-related complications
Time frame: From the ablation procedure through 6 months after ablation
Console operability
Time frame: During the ablation procedure (Day 0)
System stability
Time frame: During the ablation procedure (Day 0)
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 4 Nov 2026.
- Individual participant dataSharing planned: No. Individual participant data (IPD) will not be shared. The complete dataset contains sensitive clinical and imaging records, as well as device-specific proprietary parameters essential to the High-Frequency Irreversible Electroporation (H-FIRE) technology. Sharing these data externally poses significant risks to intellectual property protection. Furthermore, external sharing of de-identified IPD would require extensive compliance reviews to ensure adherence to patient privacy regulations and cross-border data security laws. Aggregate summary results will be reported in the primary publication.
Related trials for Malignant Liver Tumors
Recruiting
The Vanguard Study: Testing a New Way to Screen for Cancer
Bladder Carcinoma, Breast Carcinoma
Active, not recruitingPhase 1
Prospective Exploratory Study of FAPi PET/CT With Histopathology Validation in Patients With Various Cancers
Bladder Carcinoma, Cervical Carcinoma
RecruitingPhase 2
At-Home Cancer Directed Therapy Versus in Clinic for the Treatment of Patients With Advanced Cancer
Advanced Anal Carcinoma, Advanced Biliary Tract Carcinoma
Recruiting
Distance-Based Exercise to Preserve Function and Prevent Disability
Localized Malignant Solid Neoplasm, Anal Cancer
Active, not recruiting
Examinations of Tissue From Ablated Malignant Liver Metastases as Predictors of Outcome
Liver Cancer
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
The record lists no contact. Use the official record to reach the sponsor.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Compound Steep-Pulse Therapy Apparatus (HFMP-02) and Cool-tip RF Ablation System (CTRF220) in people with Malignant Liver Tumors, run by REMD Medical Technology at 1 site in China.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 6 inclusion and 14 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 4 Nov 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in China. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Ablation success rate at 1 month after ablation (time frame: 1 month after ablation). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 4 Nov 2026.