AzTrials
AzTrials

Orbital FracturesNCT07882121

Comparing Pre-adaptation of In-stock Mesh Over In-house 3D Patient Specific Model to Reconstruct Unilateral Primary Orbital Fracture With and Without Intraoperative Navigation vs Conventional Intraoperative Free-hand Mesh Bending

A study testing 3D printed patient specific model, Conventional and Brainlab navigation system in people with Orbital Fractures and Unilateral, run by Ain Shams University at 2 sites in Egypt.

Recruiting

Looking for participants now. Contact the study team or a site below to ask about taking part.

Sites and contacts
Official record
Search all trials

Trial summary

The investigators study the accuracy of repairing unilateral primary orbital fractures using a new technique, using 3D printed patient specific model to preoperative adapting of the readily available in sock titanium mesh, the model is generated using patient's own CT (DICOM files), to be compared with a control group… Read more about this study

Who is it for?
Ages 18 to 55 years
Conditions the study is for
Orbital Fractures, Unilateral, Recent
What is being tested?
3D printed patient specific model, Conventional and Brainlab navigation system
Could I receive a placebo?
No, everyone receives an active treatment
How many people
30 participants
Where
2 sitesEgypt
Study dates
1 Jun 2025to 15 Apr 2027
Phase
Interventional
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 55 years
  • All sexes
  • No healthy volunteers
  • Adult

Who may be able to join

  • Fracture orbital wall:
  • Timing: Recent (<3 weeks from trauma) Age: 18-55 years Sex: Both
  • Clinical Findings:
  • ± Globe malposition, Enophthalmos ≥ 2 mm or Diplopia CT Findings
  • Fracture Pattern: unilateral fractures medial wall or floor of the orbit.
  • Defect Size critical sized defects proved by CT
  • Herniation of soft tissue, and/or muscle entrapment.
  • associated non-comminuted zygomatic fracture.

Who cannot join

  • Timing Delayed (> 3 weeks from trauma)
  • Pattern : Bilateral orbital fractures
  • Associated with Comminuted zygomatic fracture or pan-facial fracture Ocular Manifestations
  • Patients with ruptured globe or associated soft tissue injury Associated conditions
  • Other life-threatening condition
  • Presence of systemic diseases affecting the globe position (e.g Hyperthyroidism, Horner's syndrome)
  • Presence of craniofacial anomalies and Facial asymmetries.
  • History of other old facial fractures Patients refusing surgery or implant.

Trial locations and contacts

2 sites in 1 country. Contact the study team or a site near you to ask about taking part.

Reem Mohamed Mahmoud, MBBCh, MSc contact

+201064483493, +201223418832

reem.saas@gmail.com

Egypt2 sites, 1 recruiting
  • Ain shams university hospitals, department of plastic, burn and maxillofacial surgery

    Cairo, Abbasia, 11851

    Reem M. S. H. Mahmoud, MSc, +201064483493, resident153@med.asu.edu.eg

    Reem M, S, H Mahmoud, MSc

    Recruiting
  • Ain shams university hospitals

    Cairo, Cairo Governorate, 1815

    Completed

Other trials in Egypt

About this study

Official title: Pre-adaptation of In-stock Mesh Using In-house 3D Patient Specific Model to Reconstruct Unilateral Primary Orbital Fracture

The investigators study the accuracy of repairing unilateral primary orbital fractures using a new technique, using 3D printed patient specific model to preoperative adapting of the readily available in sock titanium mesh, the model is generated using patient's own CT (DICOM files), to be compared with a control group where conventional intraoperative free-hand adaptation of the same mesh is done, comparing results with a third group using intraoperative navigation system as quality control for better positioning of the preadapted mesh , Assessment is done both radiologically and clinically,

  1. CLINICALLY : 4 visits
Read more
  • Baseline (PREOP).
  • POSTOP over 1,3 and 6 months interval, subjects assessed for binocular diplopia and limitation of ocular motility using follow my finger test in 8 cardinal gazes, enophthalmos using objective Hertle's exophthalmometer, hypoesthesia over infraorbital nerve distribution.
  1. Radiologically CT maxillofacial to calculate the difference of orbital volume between fractured and normal orbit, pre and postoperatively using Brainlab software workflow.

Preoperatively : defect size is calculated and Postoperatively: proper position of the implant by superimposition (fusion) of postop CT over preop plan

Being tested
3D printed patient specific model, Conventional, Brainlab navigation system
Keywords
Virtual surgical planning, 3D printing, CAD, Patient specific model, Pre-bent mesh, titanium mesh, orbital reconstruction, intraoperative navigation
Medical subject headings
Orbital Fractures

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • 3D printed patient specific modelProcedure or surgery

    An in-house three-dimensional patient-specific model is produced from preoperative computed tomography imaging to assist surgical planning for unilateral orbital fracture reconstruction. The model depicts the orbital defect and the surrounding available bony ledges, allowing direct visualization of the defect boundaries and identification of the bony support that the mesh must reach and rest upon. This distinguishes the model from models that reproduce only the intended reconstructed orbital contour.

    Before surgery, an available stock mesh is shaped using the model to achieve the planned orbital contour and adequate coverage of the defect, extending to the identified bony ledges. During surgery, the pre-adapted mesh is placed to reconstruct the orbital defect, with adjustments as required to achieve an appropriate fit and support.

  • ConventionalProcedure or surgery

    intraoperative visualization of orbital defect, freehand shaping and bending of available mesh

  • Brainlab navigation systemDevice

    Also called Intraoperative navigator

    intraoperative quality control check using navigation as an additive step to identify surrounding boney ledges for better accuracy of the pre-adapted mesh position

Study groups in NCT07882121
Study groupRoleWhat they receive
Control - Conventional orbital fracture reconstructionActive comparatorPatients with orbital fractures receiving the regular surgery with no new concept
Receives: Procedure: Conventional
Intervention Group- Preadapted mesh over 3D Patient Specific model for orbital reconstructionExperimentaluse of in house 3D Patient Specific model to preadapt the same mesh to increase percision and decrease operative time
Receives: Procedure: 3D printed patient specific model
Intraoperative navigation positioning of Preadapted mesh for orbital reconstructionExperimentalsame technique for second group , added to it the use of navigation intraoperatively to detect the surrounding boney ledges to identify if it has role in better mesh positioning
Receives: Procedure: 3D printed patient specific model; Device: Brainlab navigation system

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. accuracy of restoration of orbital volume

    preoperative and postoperative assessment in the difference between the volume of the fractured orbit and the unaffected contralateral orbit, measured using computed tomography. Orbital volume discrepancy is expressed in cubic centimetres. A reduction in the magnitude of the discrepancy indicates closer restoration to the orbit.

    Measured: immediate postoperatively

Secondary outcomes (3)
  1. Operative time

    Duration of mesh insertion in minutes, using the same defined start and end points in both groups.

    Measured: intraoperative

  2. Sequence of clinical outcome (Enophthalmos, Diplopia, Limited ocular motility)

    Difference in globe projection between the affected and unaffected eyes, measured in millimetres using the hertles exophthalmometer. Diplopia and ocular motility by examination

    Measured: preoperatively and 1,3,6 months postoperatively

  3. Mesh position

    Assessed radiologically by fusing postoperative CT over preoperative plan, and clinically by assessment of any palpable mesh or screws

    Measured: radiologically: immediate, Clinically: 1,3 and 6 months postoperatively

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted20 Oct 2026
  2. Study start1 Jun 2025
  3. Primary completion1 Mar 2027 (estimated)
  4. Study completion15 Apr 2027 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
Triple blind
Who is masked
Participant, Care provider, Outcomes assessor
Enrolment
30 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07882121
Sponsor's protocol ID
FMASU MD116/2025
Status last verified
Oct 2026
First submitted
10 Oct 2026
Last updated
20 Oct 2026
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Undecided

Publications

  • Verbist M, Dubron K, Bila M, Jacobs R, Shaheen E, Willaert R. Accuracy of surgical navigation for patient-specific reconstructions of orbital fractures: A systematic review and meta-analysis. J Stomatol Oral Maxillofac Surg. 2024 Jun;125(3):101683. doi: 10.1016/j.jormas.2023.101683. Epub 2023 Nov 10.

    PubMed 37951500
  • Raisian S, Fallahi HR, Khiabani KS, Heidarizadeh M, Azdoo S. Customized Titanium Mesh Based on the 3D Printed Model vs. Manual Intraoperative Bending of Titanium Mesh for Reconstructing of Orbital Bone Fracture: A Randomized Clinical Trial. Rev Recent Clin Trials. 2017;12(3):154-158. doi: 10.2174/1574887112666170821165206.

    PubMed 28828975
  • Singh AK, Khanal N, Chaulagain R, Sharma N, Thieringer FM. Is the Pre-Shaping of an Orbital Implant on a Patient-Specific 3D-Printed Model Advantageous Compared to Conventional Free-Hand Shaping? A Systematic Review and Meta-Analysis. J Clin Med. 2023 May 12;12(10):3426. doi: 10.3390/jcm12103426.

    PubMed 37240532

Questions about this trial

What is this clinical trial studying?

A study testing 3D printed patient specific model, Conventional and Brainlab navigation system in people with Orbital Fractures and Unilateral, run by Ain Shams University at 2 sites in Egypt.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 8 inclusion and 8 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: looking for participants now, as of the sponsor's last update on 20 Oct 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 2 sites in Egypt. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

Contact Reem Mohamed Mahmoud, MBBCh, MSc (+201064483493, +201223418832, reem.saas@gmail.com), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

accuracy of restoration of orbital volume (time frame: immediate postoperatively). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT07882121, which also lists 3 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 20 Oct 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in