Cardiac Arrest (CA)OXY-VENTNCT07870551

The OXY-VENT Study

A study testing Ventilation Feedback Device (Active) in people with Cardiac Arrest (CA) and Cardiopulmonary Resuscitation (CPR), run by Jeroen van Eijk at 1 site in Netherlands.

Not yet recruiting

Opening soon. The study is approved but enrolment has not started yet. Sites may already take enquiries.

Sites and contacts
Official record
Search all trials

Trial summary

Adequate ventilation during cardiopulmonary resuscitation is essential to maintain oxygenated blood supply to vital organs, yet achieving guideline-adherent synchronous ventilation (two breaths per pause after 30 compressions, with sufficient expiratory tidal volume) remains difficult in practice. Read more about this study

Who is it for?
Ages 18 years and older
What is being tested?
Ventilation Feedback Device (Active)
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
515 participants
Where
1 siteNetherlands
Study dates
1 Jan 2027to 1 Sep 2028
Phase
Interventional
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • All adults with OHCA will be included, regardless of rhythm, whether the cardiac arrest was witnessed, or whether bystander CPR was initiated.

Who cannot join

  • Pediatric and traumatic cardiac arrests are excluded.

Trial locations and contacts

1 site in 1 country. Contact the study team or a site near you to ask about taking part.

Jeroen A. van Eijk, MD contact

+31 020 566 59 69

j.vaneijk1@amsterdamumc.nl

Patrick Schober, MD, PhD contact

Netherlands1 site
  • RAVU

    Bilthoven, 3723BC

    René Boomars, Msc, r.boomars@ravu.nl

Other trials in Netherlands

About this study

Official title: The OXY-VENT Study: an Investigator-initiated, Single-center, Parallel-group, Randomized Controlled Superiority Trial of Real-time Ventilation Feedback Versus Control to Improve Ventilation Quality in Adults With Out-of-hospital Cardiac Arrest.

Adequate ventilation during cardiopulmonary resuscitation is essential to maintain oxygenated blood supply to vital organs, yet achieving guideline-adherent synchronous ventilation (two breaths per pause after 30 compressions, with sufficient expiratory tidal volume) remains difficult in practice.

In the prehospital setting, ventilation is delivered manually by resuscitator bag without measurement or feedback, and thoracic impedance data suggest that in 40-60% of ventilation pauses no ventilation is detected, with a dose-dependent association between successful ventilation and ROSC, survival, and neurological outcome in post-hoc analyses.

Visible chest rise, the current clinical guide, correlates poorly with delivered tidal volume. Real-time ventilation feedback devices (VFDs) have improved ventilation quality in manikin studies, but an ILCOR scoping review found only few, mostly observational or before-after, clinical studies and called for prospective evaluation. We therefore hypothesize that real-time, objective feedback on tidal volume and leakage improves guideline adherence compared with standard, unguided ventilation, in a randomized trial in the setting of a supraglottic airway and synchronous ventilation.

Read the detailed description

SUMMARY

Rationale: Effective ventilation is critical for maintaining oxygenation and carbon dioxide elimination during cardiopulmonary resuscitation (CPR). However, observational studies consistently show that adequate lung inflation is frequently not achieved during synchronous ventilation, in which two ventilations are delivered after every 30 chest compressions. The absence of real-time feedback during manual ventilation contributes to substantial variability in delivered tidal volumes and pressures, representing a potentially modifiable factor to improve ventilation quality and, potentially, patient outcomes.

Objective: The OXY-VENT study aims to determine whether the EOlife, a real-time ventilation feedback device (VFD) can enhance ventilation quality during CPR.

Study design: The OXY-VENT study is an investigator-initiated, single-center, open-label, parallel-group, randomized controlled superiority trial designed to evaluate the efficacy of a ventilation feedback intervention versus a control device in recording-only mode on ventilation quality during cardiac arrest.

Study population: Adult patients experiencing out-of-hospital cardiac arrest treated by regional ambulance services in Utrecht, the Netherlands. Patients are managed using synchronous ventilation following immediate placement of a supraglottic airway device.

Intervention: Upon activation of the VFD, participants are randomly assigned to receive ventilation in either active feedback mode (intervention) or recording-only mode (control).

Main study parameters/endpoints: The primary outcome is the proportion of pauses during which guideline-adherent ventilations are administered. This is defined as the delivery of two ventilations per pause, each with an expiratory tidal volume of 400-500 mL.

Nature and extent of the burden and risks associated with participation, benefit and group relatedness:

Although manikin studies suggest promising results, high-quality clinical evidence supporting the use of VFDs during cardiopulmonary resuscitation remains limited. Participation in this trial imposes minimal additional burden, as patients are unconscious at the time of inclusion and the intervention does not interfere with ongoing resuscitation efforts.

The VFD is integrated into the standard resuscitation workflow, ensuring that usual care is maintained in both study groups. The associated risks are considered negligible, as the device does not alter ventilation delivery but provides feedback only in the intervention arm, while operating in recording-only mode in the control arm.

Given the physiological rationale and prior evidence linking ventilation quality to improved outcomes, there is a plausible expectation that improved guideline adherence - the primary endpoint - may confer an individual benefit to the participant. Group allocation does not expose participants to differential risk beyond the presence or absence of feedback, and the study may additionally contribute to improved ventilation quality during resuscitation in future patients.

Being tested
Ventilation Feedback Device (Active), Control (Recording-Only)
Keywords
ventilation, cardiopulmonary resuscitation, ventilation feedback device, advanced life support
Medical subject headings
Heart Arrest, Respiratory Aspiration

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Ventilation Feedback Device (Active)Device

    The same flow sensor and device measure inspiratory and expiratory tidal volume, leakage, and ventilation timing, connected between the resuscitator bag and airway device. In feedback mode, the device displays real-time visual feedback to guide the provider toward a target expiratory tidal volume of 400-500 mL.

  • Control (Recording-Only)Device

    A ventilation feedback device integrated into standard resuscitation equipment, used during out-of-hospital cardiac arrest. The device measures inspiratory and expiratory tidal volume, leakage, and ventilation timing via a flow sensor connected between the resuscitator bag and airway device. In this arm, the device is randomly initiated in recording-only mode, recording the same ventilation parameters without displaying any feedback to the provider.

Study groups in NCT07870551
Study groupRoleWhat they receive
Feedback GroupExperimentalParticipants receive resuscitation using the ventilation feedback device operating in feedback mode, in which real-time visual feedback is displayed to guide the provider toward a target expiratory tidal volume of 400-500 mL.
Receives: Device: Ventilation Feedback Device (Active)
Recording-Only (Control) GroupActive comparatorParticipants receive resuscitation using the same device operating in recording-only mode, in which ventilation parameters are recorded but no feedback is displayed to the provider.
Receives: Device: Control (Recording-Only)

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Proportion of guideline-adherent ventilation pauses per resuscitation attempt

    A ventilation pause is a compression pause during CPR in which rescue breaths are delivered. Guideline adherence per pause is defined as delivery of two ventilations, each with a device-measured expiratory tidal volume of 400-500 mL, per European Resuscitation Council recommendations. For each patient, the proportion of guideline-adherent pauses is calculated as the number of adherent pauses divided by the total analyzable pauses during the resuscitation attempt. The primary outcome is the mean of this patient-level proportion, averaged across all patients, compared between feedback and control groups.

    Measured: From enrollment to the end of treatment at day 1

Secondary outcomes (8)
  1. Number of Participants with Prehospital Return of Spontaneous Circulation (ROSC)

    Any return of spontaneous circulation (ROSC), defined per the Utstein Out-of-Hospital Cardiac Arrest Registry Template, at any point during the prehospital resuscitation attempt.

    Measured: From enrollment to the end of treatment at day 1

  2. Number of Participants Surviving to 30 Days

    Survival to 30 days

    Measured: From enrollment to day 30

  3. Number of Participants with Favorable Neurological Outcome

    Favorable neurological outcome, defined as a Modified Rankin Scale (mRS) score of 0-3, where 0 indicates no symptoms and 6 indicates death, assessed at hospital discharge or 30 days.

    Measured: From enrollment to hospital discharge or 30 days

  4. Proportion of Guideline-Adherent Ventilations

    Proportion (%) of ventilations with expiratory tidal volume 400-500 mL, per European Resuscitation Council recommendations, calculated across all ventilations pooled across patients during prehospital resuscitation. Device-recorded data, compared between feedback and control groups.

    Measured: From enrollment to the end of treatment at day 1

  5. Expiratory Tidal Volume per Ventilation

    Central tendency (mean or median) of expiratory tidal volume per ventilation, in milliliters (mL), calculated across all ventilations pooled across patients (not averaged per patient first). Device-recorded, compared between feedback and control groups.

    Measured: From enrollment to the end of treatment at day 1

  6. Ventilation Leakage

    Central tendency of gas leakage per ventilation, expressed as a percentage (%) of inspiratory tidal volume, calculated across all ventilations pooled across patients. Device-recorded, compared between feedback and control groups.

    Measured: From enrollment to the end of treatment at day 1

  7. Ventilation Pause Duration

    Duration of compression pauses in which ventilations are delivered, in seconds, calculated across all pauses pooled across patients. Device-recorded, compared between feedback and control groups.

    Measured: From enrollment to the end of treatment at day 1

  8. Minute Ventilation

    Inspiratory and expiratory minute volume, in liters per minute (L/min), calculated across all minutes pooled across patients. Device-recorded, compared between feedback and control groups.

    Measured: From enrollment to the end of treatment at day 1

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted13 Oct 2026
  2. Study start1 Jan 2027 (estimated)
  3. Primary completion1 Jun 2028 (estimated)
  4. Study completion1 Sep 2028 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Model description
Participants are randomized 1:1 to receive ventilation with real-time feedback (intervention) or with the same device operating in recording-only mode (control). Randomization is performed automatically by the study device itself: upon activation, the device randomly initiates in either feedback or recording-only mode and remains in the assigned mode for the first hour of use to ensure consistent treatment allocation.
Masking
Double blind
Who is masked
Participant, Outcomes assessor
Enrolment
515 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07870551
Sponsor's protocol ID
NL-011106
Other IDs
NL-011106
Acronym
OXY-VENT
Status last verified
Oct 2026
First submitted
6 Jul 2026
Last updated
19 Oct 2026
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study testing Ventilation Feedback Device (Active) in people with Cardiac Arrest (CA) and Cardiopulmonary Resuscitation (CPR), run by Jeroen van Eijk at 1 site in Netherlands.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: opening soon, as of the sponsor's last update on 19 Oct 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Netherlands. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

Contact Jeroen A. van Eijk, MD (+31 020 566 59 69, j.vaneijk1@amsterdamumc.nl), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Proportion of guideline-adherent ventilation pauses per resuscitation attempt (time frame: From enrollment to the end of treatment at day 1). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 19 Oct 2026.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in