AzTrials
AzTrials

Edentulous JawNCT07740798

Trueness of Intra-Oral Scanners Compared to an Extra-Oral Scanner for Scanning of Mandibular Edentulous Impressions

A study testing Digital impression of the mandibular edentulous arch in people with Edentulous Jaw, run by Ain Shams University.

Not yet recruiting

Opening soon. The study is approved but enrolment has not started yet. Sites may already take enquiries.

Sites and contacts
Official record
Search all trials

Trial summary

the relative accuracy of different intraoral scanner types specifically for capturing the complex morphology of edentulous arches, including peripheral borders and mobile tissues, remains an area of investigation, with conflicting reports in the literature. Read more about this study

Who is it for?
Any ageHealthy volunteers can take part
Conditions the study is for
Edentulous Jaw
What is being tested?
Digital impression of the mandibular edentulous arch
Could I receive a placebo?
No, everyone receives an active treatment
How many people
9 participants
Where
No sites listed yet
Study dates
15 Jul 2026to 15 Oct 2026
Phase
Interventional
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages Any age
  • All sexes
  • Healthy volunteers accepted
  • Child, Adult, Older adult

Who may be able to join

  • edentulous patients
  • last teeth extraction 6 months before the impression procedures

Who cannot join

  • un cooperative patients
  • Neuromotor disorders
  • Parkinsonism
  • Tremors

Trial locations and contacts

No sites are listed yet. Contact the study team or a site near you to ask about taking part.

About this study

the relative accuracy of different intraoral scanner types specifically for capturing the complex morphology of edentulous arches, including peripheral borders and mobile tissues, remains an area of investigation, with conflicting reports in the literature.

The purpose of this study is to compare the accuracy of different intraoral scanners with a laboratory scanner for digitizing impressions of edentulous mandible.

Read more

Completely edentulous patients will be gathered; final impressions will be taken for them using zinc oxide \& eugenol impression material then they will be scanned with intra oral and extra oral scanners for indirect digitalization.

Scans will be superimposed and compared using a software program for analysis for accuracy in the form of trueness

Read the detailed description

completely edentulous patients will be recruited.

Study procedures:

Custom trays will be fabricated and checked for extension, and then definitive impressions will be made with type-1 low fusing impression compound (Tracing sticks; Kemdent, UK) for border molding and zinc oxide eugenol impression paste (Cavex Holland B.N) for the impression. Reference markers will be placed on the impressions in anterior and posterior ridge areas.

The indirect digitalization of impressions will be made with two different Intraoral scanning devices and a laboratory scanner.

  • Intra oral scanners are:
  1. Aoralscan (Shining 3D Tech. Co., Ltd. Hangzhou, China): structured light-optical triangulation technology.
  2. MEDIT i600 (Medit Corp. Seoul, South Korea): structured light-3d-in-motion video technology.
  • Extra oral scanner: UP3D. Scans will be exported as standard tessellation language (STL) files. The STL files then will be compared using a 3D analysis software program for analysis.

For "trueness" measurements every STL file of each experimental group will be superimposed to the extra oral scan.

Conditions
Edentulous Jaw
Being tested
Digital impression of the mandibular edentulous arch
Medical subject headings
Jaw, Edentulous

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Digital impression of the mandibular edentulous archOther

    Digital impression of the mandibular edentulous arch will be made by MEDIT i600 scanner (Medit Corp. Seoul, South Korea) followed by another digital impression of the same arch using Aoralscan scanner (Shining 3D Tech. Co., Ltd. Hangzhou, China). Both impressions will be compared to each other in terms of trueness.

Study groups in NCT07740798
Study groupRoleWhat they receive
Digital impression of the mandibular edentulous archExperimentalDigital impression of the mandibular edentulous arch will be made by MEDIT i600 scanner (Medit Corp. Seoul, South Korea) followed by another digital impression of the same arch using Aoralscan scanner (Shining 3D Tech. Co., Ltd. Hangzhou, China). Both impressions will be compared to each other in terms of trueness.
Receives: Other: Digital impression of the mandibular edentulous arch

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. trueness assessment of impression techniques for mandibular edentulous arches

    Assessment of trueness of Digital impression of the mandibular edentulous arch using intra oral scanner will be made by MEDIT i600 scanner (Medit Corp. Seoul, South Korea) followed by another digital impression of the same arch using Aoralscan scanner (Shining 3D Tech. Co., Ltd. Hangzhou, China). Both impressions will be compared to each other in terms of trueness in relation to desktop scanner. Root mean square of trueness in m.m will be reported.

    Measured: 3 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted3 Aug 2026
  2. Study start15 Jul 2026 (estimated)
  3. Primary completion1 Oct 2026 (estimated)
  4. Study completion15 Oct 2026 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Health services research
Allocation
Not applicable
Intervention model
Single group
Model description
final impressions will be taken for the participants using zinc oxide \& eugenol impression material then they will be scanned with intra oral and extra oral scanners for indirect digitalization. Scans will be superimposed and compared using a software program for analysis for accuracy in the form of trueness.
Masking
None (open label)
Enrolment
9 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07740798
Sponsor's protocol ID
OOC-8-25-6
Status last verified
Aug 2026
First submitted
14 Jul 2026
Last updated
4 Aug 2026
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No

Questions about this trial

What is this clinical trial studying?

A study testing Digital impression of the mandibular edentulous arch in people with Edentulous Jaw, run by Ain Shams University.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: opening soon, as of the sponsor's last update on 4 Aug 2026. Status can change between updates, so confirm with the study contact before making plans.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

Contact Ahmed Mohamed, MD (01111191337, ahmedmostafa@dent.asu.edu.eg), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

trueness assessment of impression techniques for mandibular edentulous arches (time frame: 3 months). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 4 Aug 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in
Clinical Trial NCT07740798 | AzTrials