Atrial Fibrillation (AF)ASSESS PFANCT07721948
Assessment of Catheter Tissue Contact in PFA
A study testing Electrode tissue contact assessment during pulsed field ablation in people with Atrial Fibrillation (AF), run by University Medical Centre Ljubljana at 1 site in Slovenia.
Trial summary
Pulmonary vein isolation remains the cornerstone of invasive treatment for atrial fibrlllation. Despite recent technological advances in the field of pulsed field ablation (PFA) pulmonary vein isolation durability and arrhythmia free success rates remain approximately at the level of previous years and the… Read more about this study
- Who is it for?
- Ages 18 to 80 years
- Conditions the study is for
- Atrial Fibrillation (AF)
- What is being tested?
- Electrode tissue contact assessment during pulsed field ablation
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 60 participants
- Where
- 1 siteSlovenia
- Study dates
- 1 Dec 2026to 1 Dec 2028
- Phase
- Interventional
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 80 years
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Patients with electrocardiographically documented paroxysmal atrial fibrillation (AF), defined according to the European Heart Rhythm Association (EHRA) guidelines
Who cannot join
- Contraindication to pulsed field ablation in the left atrium (e.g., presence of a left atrial appendage occlusion device).
- Contraindication to undergoing the procedure under general anesthesia.
- Age >80 years.
- Markedly enlarged left atrium (diameter >50 mm on echocardiography, LAVI >50 mL/m²).
- Life expectancy <1 year.
- Acute life-threatening illness.
Show all 9Show fewer
- Presence of left atrial thrombus.
- Secondary atrial fibrillation.
- Previous left atrial ablation.
Trial locations and contacts
1 site in 1 country. Contact the study team or a site near you to ask about taking part.
Slovenia1 site
University Medical Centre Ljubljana
Ljubljana, 1000
Matevž Jan, MD, PhD, 0038615228238, matevz.jan@kclj.si
Jernej Štublar, PhD
About this study
Official title: Assessment of Electrode-tissue Contact and Pulmonary Vein Isolation Durability After Pulsed Field Ablation With a Circular "Single Shot" Catheter in Patients With Paroxysmal Atrial Fibrillation
Pulmonary vein isolation remains the cornerstone of invasive treatment for atrial fibrlllation. Despite recent technological advances in the field of pulsed field ablation (PFA) pulmonary vein isolation durability and arrhythmia free success rates remain approximately at the level of previous years and the radiofrequency ablation era.
Isolation durability during PFA procedures might be enhanced by:
Read more
- Intraprocedural monitoring contact of catheter electrode to atrial tissue.
- Intraprocedural assessment of the transmurality of irreversible electroporation lesion.
The aim of our study is to use intracardiac electrogram (iEGM) based analysis for assessment of catheter-tissue contact and PFA lesion durability.
Read the detailed description
Study design: single group, prospective, observational study. Inclusion criteria and eligibility: patients with paroxysmal atrial fibrillation referred to our center for catheter ablation in accordance with EHRA guidelines and with signed written consent for participation in the study.
Study group: 60 patients divided in two groups. Group 1: initial 10 patients that will have the PFA procedure performed as is stated under Group 1 in the Procedural Protocol section.
Group 2: next 50 patients that will have procedural protocol defined after analysis of procedures in the initial 10 patients.
Procedural protocol:
all patients will have a contrast enhanced computer tomography (CTA) scan of the left atrium performed before the ablation procedure. CTA based left atrial 3D reconstruction will be created with a dedicated segmentation software and fused with the 3D model of the left atrium created during the procedure using the 3D electroanatomical mapping (EAM) system.
Procedures will be performed in deep sedation, using 3D EAM system and intracardiac echocardiography. PFA applications per vein and per antrum will be delivered as specified and recommended by Medtronic. After full lesion set high density mapping of pulmonary veins, venous ostia and antral regions for signs of acute conduction gaps and residual (dormant) conduction within isolation lines will be performed.
Group 1: will include the first 10 patients. First PFA applications per side (left or right) will be delivered in a manual mode (4 manual applications per one full set). An intracardiac electrocardiogram (iEGM) recording period of 30 seconds will be used before the start of applications and a 2 minute iEGM recording period will be used after each of the 4 manual applications with the ablation catheter left in place during the recording. After the first application on each side, applications will be switched to automatic mode and a iEGM recording period of 2 minutes will be used after each automatic application with 30 seconds recording used as the baseline. Recording will include bipolar and unipolar iEGMs. Total number of applications will 32, 4 ostial and 4 antral per vein.
Group 2: will include additional 50 patients. Mode of iEMG recording (bipolar, unipolar, filter settings) and recording time will differ from Group 1 and will be specified based on analysis and correlation of iEGM recordings with acute and longterm conduction gaps.
In this group additional PFA applications will be delivered at ostial/antral regions that will harbor potentially insufficient (nontransmural irreversible electroporation) lesions according to analysis and correlation of iEGM recordings with acute and longterm conduction gaps.
Follow-up (Group 1 and 2) At 6-8 weeks after the procedure all patients will undergo a mandatory reassessment procedure with high density mapping of veins, venous ostia and antral regions for signs of longterm conduction gaps. Any conduction gaps and residual (dormant) conduction within isolation lines will be recorded and tagged on the 3D EAM maps.
Patients will be followed at the outpatient clinic at 3, 6 and 12 months with 7-day holter ECG recordings at each visit.
Outcome measures
- Assessment of contact (electrode - tissue) based on analysis of intraprocedural characteristics and acute changes of bipolar iEGMs.
- Assessment of PFA lesion durability based on analysis of intraprocedural characteristics and changes of unipolar iEGMs and information about the presence of conduction gaps from mandatory reassessment procedures.
Study will be conducted in two phases
Phase 1 (duration 1 year):
Obtaining approval of Medical ethics committee Enrolment of 10 patients (group 1) with remap at 6-8 weeks
Phase 2 (duration 2 years) with 1 year follow-up in an out-patient clinic using 7-day holter ECG recordings at 3, 6 and 12 months
- Conditions
- Atrial Fibrillation (AF)
- Being tested
- Electrode tissue contact assessment during pulsed field ablation
- Keywords
- Atrial Fibrillation, Pulsed field ablation, Intracardiac electrogram, Pulse Select, Contact assessment
- Medical subject headings
- Atrial Fibrillation
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Electrode tissue contact assessment during pulsed field ablationDevice
Pulsed field ablation (PFA) catheter electrode - tissue contact assessment based on analysis of bipolar intracardiac electrocardiograms: a multipolar PFA catheter will be used for pulmonary vein isolation in a manual mode, which means that instead of delivering fully therapeutic four ablative high voltage pulse trains at each location around pulmonary veins, each of those pulse trains will be delivered manually. Changes (voltage, shape,...) in bipolar intracardiac electrocardiograms (iEGM) measured with ablative catheter electrodes will be assessed after each manual pulse train delivery.
| Study group | Role | What they receive |
|---|---|---|
| Catheter - tissue contact assessment | Experimental | Assessment of contact between electrodes on the pulsed field ablation (PFA) catheter and left atrial wall will be made based on change of bipolar intracardiac electrograms (iEGM) after first PFA delivery. Receives: Device: Electrode tissue contact assessment during pulsed field ablation |
What is being measured
The primary outcome is the main question the study is designed to answer.
Assessment of contact
Assessment of contact (electrode - tissue) based on analysis of intraprocedural characteristics and acute changes of bipolar iEGMs: when bipolar iEGM voltage amplitude will decrease significantly after first manual ablative pulse train delivery the contact will be considered as good, in contrast to no or minimal change in bipolar iEGM amplitude when contact will be considered as poor.
Measured: During index procedure.
Assessment of PFA lesion durability
Assessment of PFA lesion durability based on analysis of intraprocedural characteristics and changes of unipolar intracardiac electrocardiograms (iEGM). Additionally to bipolar iEGM changes during index procedure for used for contact assessment also the unipolar iEGM changes will be followed with an assumption that prolonged and unchanged increased unipolar iEGM amplitude after PFA delivery at each location correlates with transmural PFA lesion formation that leads to durable ablation lesions and durable pulmonary vein isolation.This durability of ablation lesions and pulmonary vein isolation will be assessed at mandatory reassessment procedures (remapping procedures with a high-density mapping catheter).
Measured: From index procedure until 6-8 week mandatory reassessment procedure.
Secondary outcomes (1)
Recurrence of arrhythmia
Recurrence based on registration of 30 second or longer episodes of atrial fibrillation/atrial flutter/atrial tachycardia on 7-day holter electrocardiogram or arrhythmia recorded on 12-lead surface electrocardiogram at 3, 6 and 12 monthy after index procedure. If available, additional symptom driven holter ECG or 12-lead electrocardiogram recordings will be used for analysis.
Measured: From index procedure until completed 12 month follow-up.
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted23 Jul 2026
- Study start1 Dec 2026 (estimated)
- Primary completion1 Dec 2028 (estimated)
- Study completion1 Dec 2028 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Atrial Fibrillation (AF)Studies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Sequential
- Masking
- None (open label)
- Enrolment
- 60 participants (estimated)
Sponsor and investigators
- Lead sponsor
- University Medical Centre Ljubljana
- Sponsor type
- University, hospital or other
- Collaborators
- Medtronic
- Responsible party
- Principal investigator, Matevz Jan, University Medical Centre Ljubljana
- Investigators
- Damijan Miklavčič, PhD, Study chair, University of Ljubljana
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT07721948
- Sponsor's protocol ID
- ASSESS PFA
- Acronym
- ASSESS PFA
- Status last verified
- Oct 2026
- First submitted
- 14 Jul 2026
- Last updated
- 22 Oct 2026
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
- Individual data sharing
- Yes: IPD used in results for publication.