This prospective, multicenter, observational cohort study aims to establish a post-market registry framework to evaluate the real-world clinical applicability, long-term safety, and effectiveness of innovative heart valve devices in China. Read more about this study

Who is it for?
Ages 18 years and older
What is being tested?
Transcatheter Aortic Valve Replacement, Transcatheter Edge-to-Edge Repair and Transcatheter Tricuspid Valve Annuloplasty
Type of treatment
Medical device
How many people
5,500 participants
Where
1 siteChina
Study dates
10 May 2026to 31 Jan 2029
How long will I take part?
1 Year
Phase
Observational

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Study population: Patients with valvular heart disease who have undergone treatment with innovative heart valve replacement or repair systems, including transcatheter aortic valve replacement (TAVR), transcatheter edge-to-edge repair (TEER), and transcatheter tricuspid valve annuloplasty (TTVA), at 50 medical centers in China.

Who may be able to join

  • Patients with valvular heart disease (VHD) receiving treatment with prosthetic aortic valve replacement systems (transcatheter and surgical valves), transcatheter mitral valve edge-to-edge repair (TEER) systems, or transcatheter tricuspid valve annuloplasty systems
  • Age ≥ 18 years
  • Patients who voluntarily participate in the study and sign the informed consent form
  • Willing and able to comply with follow-up requirements

Who cannot join

None listed.

Trial locations and contacts

1 site in 1 country. Contact the study team or a site near you to ask about taking part.

Guangyuan Song, MD, PhD contact

+86 13801120805

songgy_anzhen@vip.163.com

China1 site
  • Beijing Anzhen Hospital

    Beijing, Beijing Municipality, 100029

    Guangyuan Song, MD, PhD, +86 13801120805, songgy_anzhen@vip.163.com

Other trials in China

About this study

Official title: An Active Post-Market Surveillance Study Assessing the Real-World Clinical Applicability, Long-Term Safety, and Effectiveness of Innovative Medical Devices for Valvular Heart Disease

This prospective, multicenter, observational cohort study aims to establish a post-market registry framework to evaluate the real-world clinical applicability, long-term safety, and effectiveness of innovative heart valve devices in China.

Read the detailed description

This prospective, multicenter, observational registry study plans to consecutively enroll patients across 50 Chinese hospitals undergoing treatment with innovative heart valve devices-including transcatheter aortic valve replacement (TAVR), surgical aortic valve replacement (SAVR), transcatheter mitral valve edge-to-edge repair (TEER), and transcatheter tricuspid valve annuloplasty (TTVA) systems. By collecting comprehensive data on medical history, physical examinations, laboratory tests, echocardiography, computed tomography (CT), electrocardiogram (ECG), wearable synchronous electrocardiogram-phonocardiogram, procedural details, pharmacotherapy, as well as regular clinical and imaging follow-up, this study aims to establish a post-market registry framework to evaluate the real-world clinical applicability, long-term safety, and effectiveness of innovative heart valve devices.

Being tested
Transcatheter Aortic Valve Replacement, Transcatheter Edge-to-Edge Repair, Transcatheter Tricuspid Valve Annuloplasty, Surgical Aortic Valve Replacement
Medical subject headings
Aortic Valve Stenosis, Aortic Valve Insufficiency, Mitral Valve Insufficiency, Tricuspid Valve Insufficiency

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Transcatheter Aortic Valve ReplacementDevice

    Transcatheter Aortic Valve Replacement

  • Transcatheter Edge-to-Edge RepairDevice

    Transcatheter Edge-to-Edge Repair

  • Transcatheter Tricuspid Valve AnnuloplastyDevice

    Transcatheter Tricuspid Valve Annuloplasty

  • Surgical Aortic Valve ReplacementDevice

    Surgical Aortic Valve Replacement

Study groups in NCT07605624
Study groupRoleWhat they receive
Transcatheter Aortic Valve ReplacementNot described
Receives: Device: Transcatheter Aortic Valve Replacement
Transcatheter Edge-to-Edge RepairNot described
Receives: Device: Transcatheter Edge-to-Edge Repair
Transcatheter Tricuspid Valve AnnuloplastyNot described
Receives: Device: Transcatheter Tricuspid Valve Annuloplasty
Device: Surgical Aortic Valve ReplacementNot described
Receives: Device: Surgical Aortic Valve Replacement

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Mortality

    Measured: Up to 1 year post-procedure

  2. Rate of neurologic events

    Neurologic events are defined according to VARC-3 criteria, including ischaemic stroke, haemorrhagic stroke, and Transient ischaemic attack (TIA):

    Ischaemic Stroke: Acute focal neurologic deficit in a vascular territory with symptoms ≥ 24h OR < 24h with neuroimaging (CT or MRI) or pathology confirmation of CNS infarction.

    Haemorrhagic Stroke: Acute neurologic deficit due to non-traumatic intracranial hemorrhage, confirmed by neuroimaging (CT or MRI) or pathology.

    TIA: Transient focal neurologic deficit < 24h presumed to be ischaemic, but without evidence of acute infarction on neuroimaging (CT or MRI) or pathology.

    Measured: Up to 1 year post-procedure

  3. Hospitalization

    Measured: Up to 1 year post-procedure

  4. Bleeding and transfusions

    Bleeding events are defined according to VARC-3 criteria:

    Type 1 (Minor): Overt bleeding that does not require intervention but leads to hospitalization, increased level of care, or medical evaluation, or requires a transfusion of 1 unit of whole blood or red blood cells.

    Type 2 (Major): Overt bleeding that requires a transfusion of 2 to 4 units of whole blood or red blood cells, or is associated with a hemoglobin drop of 3 to 5 g/dL.

    Type 3 (Life-threatening or Disabling): Overt bleeding in a critical organ (e.g., intracranial, pericardial with tamponade), causing hypovolemic shock or severe hypotension requiring vasopressors or surgery, or requiring a transfusion of ≥ 5 units of whole blood or red blood cells, or associated with a hemoglobin drop ≥ 5 g/dL.

    Type 4 (Fatal): Overt bleeding leading to death, classified as probable based on clinical suspicion or definite if confirmed by autopsy or neuroimaging.

    Measured: Up to 1 year post-procedure

  5. Vascular and access-related complications

    Measured: Periprocedural

  6. Cardiac structural complications

    Measured: Periprocedural

  7. Bioprosthetic valve dysfunction

    Measured: Up to 1 year post-procedure

  8. Clinically significant valve thrombosis

    Measured: Up to 1 year post-procedure

  9. Technical success

    Technical success is defined according to VARC-3 criteria, requiring the fulfillment of the following:

    1. Freedom from mortality.
    2. Successful access, delivery of the device, and retrieval of the delivery system.
    3. Correct positioning of a single prosthetic heart valve into the proper anatomical location.
    4. Freedom from surgery or intervention related to the device, or to a major vascular, access-related, or cardiac structural complication.

    Measured: Periprocedural

  10. Device success

    Device success is defined according to VARC-3 criteria, requiring the fulfillment of the following:

    1. Technical success
    2. Freedom from mortality
    3. Freedom from surgery or intervention related to the device or to a major vascular or access-related or cardiac structural complication
    4. Intended performance of the valve

    Measured: at 30 days

  11. Early safety

    Taking the Transcatheter Aortic Valve Replacement cohort as an example, early safety is defined according to VARC-3 criteria, requiring the fulfillment of the following:

    1. Freedom from all-cause mortality
    2. Freedom from all stroke
    3. Freedom from VARC type 2-4 bleeding
    4. Freedom from major vascular, access-related, or cardiac structural complication
    5. Freedom from acute kidney injury stage 3 or 4
    6. Freedom from moderate or severe aortic regurgitation
    7. Freedom from new permanent pacemaker due to procedure-related conduction abnormalities
    8. Freedom from surgery or intervention related to the device

    Measured: at 30 days

  12. Clinical efficacy

    Taking the Transcatheter Aortic Valve Replacement cohort as an example, clinical efficacy is defined according to VARC-3 criteria, requiring the fulfillment of the following:

    1. Freedom from all-cause mortality
    2. Freedom from all stroke
    3. Freedom from hospitalization for procedure- or valve-related causes
    4. Freedom from KCCQ Overall Summary Score <45 or decline from baseline of >10 point

    Measured: Up to 1 year post-procedure

Secondary outcomes (9)
  1. Other procedural or valve-related complications

    Measured: Periprocedural

  2. New conduction disturbances and arrhythmias

    Measured: Up to 1 year post-procedure

  3. Acute kidney injury

    Measured: Periprocedural

  4. Myocardial infarction

    Measured: Up to 1 year post-procedure

  5. Leaflet thickening and reduced motion

    Measured: Up to 1 year post-procedure

  6. Change in Kansas City Cardiomyopathy Questionnaire (KCCQ) Score

    Measured: Up to 1 year post-procedure

  7. New York Heart Association (NYHA) Functional Classification

    Class I, II, III, or IV

    Measured: Up to 1 year post-procedure

  8. EuroQol 5-Dimension (EQ-5D) Questionnaire Score

    Measured: Up to 1 year post-procedure

  9. Change in 6-Minute Walk Distance (6MWD)

    Measured: Up to 1 year post-procedure

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted26 May 2026
  2. Study start10 May 2026 (estimated)
  3. Primary completion31 Jan 2029 (estimated)
  4. Study completion31 Jan 2029 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Cohort
Time perspective
Prospective
Enrolment
5,500 participants (estimated)
Target duration
1 Year
IDs, dates and publications
ClinicalTrials.gov ID
NCT07605624
Sponsor's protocol ID
Beijinganzhen20260406
Status last verified
May 2026
First submitted
20 Apr 2026
Last updated
26 May 2026
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
No

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in