Severe Aortic Valve StenosisTAVRNCT07545369
ULTRA-EVOLUT RCT: A Comparison of Latest-Generation TAVR Valves
A study testing SAPIEN 3 Ultra Resilia and Evolut FX in people with Severe Aortic Valve Stenosis, run by Assiut University at 1 site in Egypt.
Trial summary
Title: The ULTRA-EVOLUT Randomized Control Trial: A Head-to-Head Comparison of Latest-Generation Transcatheter Aortic Valves Brief Summary: The goal of this clinical trial is to compare the latest-generation balloon-expandable (SAPIEN 3 Ultra Resilia) versus self-expanding (Evolut FX) transcatheter aortic valves in… Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Severe Aortic Valve Stenosis
- What is being tested?
- SAPIEN 3 Ultra Resilia and Evolut FX
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 200 participants
- Where
- 1 siteEgypt
- Study dates
- 12 Sep 2026to 12 Dec 2027
- Phase
- Interventional
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Severe aortic stenosis defined as aortic valve area (AVA) ≤1.0 cm², mean transvalvular gradient ≥40 mmHg, or peak transvalvular velocity ≥4.0 m/s
- Symptomatic with New York Heart Association (NYHA) functional class II, III, or IV
- Heart team consensus that transcatheter aortic valve implantation (TAVI) is the appropriate treatment strategy
- Anatomically suitable for both valve types (SAPIEN 3 Ultra Resilia and Evolut FX) as determined by pre-procedural computed tomography (CT) imaging
- Age ≥18 years
- Able and willing to provide written informed consent
- Able and willing to comply with all scheduled follow-up visits and assessments
Who cannot join
- Bicuspid aortic valve morphology
- Severe mitral regurgitation or severe tricuspid regurgitation requiring intervention
- Prior surgical or transcatheter aortic valve replacement
- Active infective endocarditis
- Contraindication to dual antiplatelet therapy or anticoagulation
- Estimated life expectancy less than 1 year due to non-cardiac comorbidities
- Pregnancy or breastfeeding
Trial locations and contacts
1 site in 1 country. Contact the study team or a site near you to ask about taking part.
Egypt1 site
Assiut University Heart Hospital
Asyut, Assiut Governorate, 71515
Ahmed A Hassaan, Master's degree, +20 1068115040, ahmed.hassaan1994@aun.edu.eg
Marwan S Mahmoud, MD, +20 1090686492, marwancordio@aun.edu.eg
About this study
Official title: The ULTRA-EVOLUT Randomized Control Trial: A Head-to-Head Comparison of Latest-Generation Transcatheter Aortic Valves
Title:
The ULTRA-EVOLUT Randomized Control Trial: A Head-to-Head Comparison of Latest-Generation Transcatheter Aortic Valves
Read more
Brief Summary:
The goal of this clinical trial is to compare the latest-generation balloon-expandable (SAPIEN 3 Ultra Resilia) versus self-expanding (Evolut FX) transcatheter aortic valves in patients with severe, symptomatic aortic stenosis who are undergoing transcatheter aortic valve implantation (TAVI).
The main questions it aims to answer are:
Does device success rate (defined by VARC-3 criteria) at 30 days differ between the SAPIEN 3 Ultra Resilia and the Evolut FX valves? Do hemodynamic performance (mean gradient, effective orifice area) and incidence of moderate/severe paravalvular leak differ between the two valve types at 30 days and 1 year? Researchers will compare patients randomized to receive the SAPIEN 3 Ultra Resilia valve versus patients randomized to receive the Evolut FX valve to see if there are differences in device success, safety outcomes, and valve performance.
Participants will:
Undergo standard pre-procedural clinical, echocardiographic, and CT assessment Be randomly assigned to receive either the SAPIEN 3 Ultra Resilia or Evolut FX valve during their clinically indicated TAVI procedure Receive post-procedure follow-up assessments including echocardiography and clinical evaluation at 24 hours, 30 days, 6 months, and 1 year
Read the detailed description
Study Design Overview
This is a prospective, randomized, controlled, single-blind, two-arm parallel-group trial conducted at a single tertiary cardiac care center. The study aims to compare the latest-generation balloon-expandable transcatheter heart valve (SAPIEN 3 Ultra Resilia) versus the latest-generation self-expanding transcatheter heart valve (Evolut FX) in patients with severe symptomatic aortic stenosis who are deemed appropriate for transcatheter aortic valve implantation (TAVI) by the local heart team.
Scientific Rationale
Previous landmark trials (e.g., PARTNER 3 and Evolut Low Risk) have established the safety and efficacy of TAVI in intermediate- to low-risk patients. However, direct head-to-head comparisons between the newest commercially available valve iterations-the SAPIEN 3 Ultra Resilia (featuring anti-calcification tissue treatment) and the Evolut FX (offering enhanced radial strength and conformability)-are lacking. Observational and registry data suggest potential differences in paravalvular leak rates, hemodynamic performance, and permanent pacemaker implantation rates, but randomized evidence is needed to eliminate bias and guide evidence-based, patient-specific valve selection.
Study Population and Enrollment
Consecutive patients with severe aortic stenosis (aortic valve area ≤1.0 cm², mean gradient ≥40 mmHg, or peak velocity ≥4.0 m/s), symptomatic (NYHA functional class II-IV), and anatomically suitable for both valve types will be screened for eligibility. Key exclusion criteria include bicuspid aortic valve, severe mitral or tricuspid regurgitation, prior aortic valve replacement, active endocarditis, and contraindication to anticoagulation.
A total of approximately 200 patients will be randomized in a 1:1 ratio to receive either the SAPIEN 3 Ultra Resilia or the Evolut FX valve. Sample size calculation assumes a 90% device success rate in both arms, 80% power, and a two-sided alpha of 0.05.
Randomization and Blinding
Randomization will be performed using a computer-generated sequence with variable block sizes. Allocation concealment will be maintained using sequentially numbered, opaque, sealed envelopes. The study is single-blind: outcome assessors and echocardiography core laboratory analysts will be blinded to valve type assignment. Operators and procedural staff cannot be blinded due to the inherent differences in valve delivery systems and deployment techniques.
Procedural and Follow-Up Protocol
All TAVI procedures will be performed according to international standards and local clinical practice. Post-procedure, patients will undergo clinical assessment, 12-lead electrocardiography, and transthoracic echocardiography at 24 hours, 30 days, 6 months, and 1 year. Adverse events will be adjudicated according to Valve Academic Research Consortium-3 (VARC-3) criteria.
Data Management and Statistical Analysis
Data will be collected prospectively using standardized case report forms and entered into a password-protected electronic database. Analysis will be performed using SPSS version 26.0 or later. Continuous variables will be compared using independent t-test or Mann-Whitney U test, and categorical variables using chi-square or Fisher's exact test. Time-to-event outcomes will be analyzed using Kaplan-Meier curves and log-rank tests. A two-sided p-value <0.05 will be considered statistically significant.
Ethical and Regulatory Considerations
The study will be conducted in accordance with the Declaration of Helsinki and Good Clinical Practice guidelines. Ethical approval has been obtained from the institutional review board. Written informed consent will be obtained from all participants prior to any study-related procedures. The trial will be registered on ClinicalTrials.gov prior to enrollment of the first participant. Results will be submitted for publication in a peer-reviewed journal regardless of the outcome.
- Conditions
- Severe Aortic Valve Stenosis
- Being tested
- SAPIEN 3 Ultra Resilia, Evolut FX
- Medical subject headings
- Aortic Valve Stenosis
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
SAPIEN 3 Ultra ResiliaDevice
Balloon-expandable transcatheter aortic valve featuring anti-calcification tissue treatment. Delivered via transcatheter approach (typically transfemoral) under fluoroscopic guidance. Valve sizes available include 20 mm, 23 mm, 26 mm, and 29 mm.
Evolut FXDevice
Self-expanding transcatheter aortic valve with enhanced radial strength and conformability. Features a recapturable and repositionable delivery system. Delivered via transcatheter approach (typically transfemoral). Valve sizes available include 23 mm, 26 mm, 29 mm, and 34 mm.
| Study group | Role | What they receive |
|---|---|---|
| SAPIEN 3 Ultra Resilia | Active comparator | Balloon-expandable transcatheter aortic valve with anti-calcification tissue treatment. Receives: Device: SAPIEN 3 Ultra Resilia |
| Evolut FX | Active comparator | Self-expanding transcatheter aortic valve with enhanced radial strength and conformability. Receives: Device: Evolut FX |
What is being measured
The primary outcome is the main question the study is designed to answer.
Device Success Rate at 30 Days
Composite endpoint defined according to Valve Academic Research Consortium-3 (VARC-3) criteria, including: absence of procedural mortality, correct positioning of a single prosthetic heart valve into the proper anatomical location, absence of moderate or severe prosthetic valve regurgitation (paravalvular or central), and acceptable hemodynamic performance (mean aortic valve gradient <20 mmHg or peak velocity <3 m/s)
Measured: 30 days post-procedure
Secondary outcomes (1)
Mean Aortic Valve Gradient
Hemodynamic performance assessed by transthoracic echocardiography. Measured as mean transvalvular gradient (mmHg).
Measured: 3 months post-procedure
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted22 Apr 2026
- Study start12 Sep 2026 (estimated)
- Primary completion12 Sep 2027 (estimated)
- Study completion12 Dec 2027 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Severe Aortic Valve StenosisStudies of the same condition, open and under way.
- More trials run by Assiut UniversityThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- None (open label)
- Enrolment
- 200 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Assiut University
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Ahmed Abdel Rahim Hassaan, Assiut University
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT07545369
- Sponsor's protocol ID
- 04-2026-100468
- Acronym
- TAVR
- Status last verified
- Apr 2026
- First submitted
- 16 Apr 2026
- Last updated
- 22 Apr 2026
- Results posted
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Study at a glance
From the registry record, last updated by the sponsor on 22 Apr 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- The ULTRA-EVOLUT Randomized Control Trial: A Head-to-Head Comparison of Latest-Generation Transcatheter Aortic Valves
- ClinicalTrials.gov ID
- NCT07545369
- Acronym / sponsor ID
- TAVR / 04-2026-100468
- Conditions
- Severe Aortic Valve Stenosis
- Study type
- Interventional
- Recruitment status
- Not yet recruiting
- Enrolment
- 200 participants (estimated)
- Lead sponsor
- Assiut UniversityUniversity, hospital or other
- Study start
- 12 Sep 2026 (estimated)
- Primary completion
- 12 Sep 2027 (estimated)
- Study completion
- 12 Dec 2027 (estimated)
- First posted
- 22 Apr 2026 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Title:
The ULTRA-EVOLUT Randomized Control Trial: A Head-to-Head Comparison of Latest-Generation Transcatheter Aortic Valves
Brief Summary:
The goal of this clinical trial is to compare the latest-generation balloon-expandable (SAPIEN 3 Ultra Resilia) versus self-expanding (Evolut FX) transcatheter aortic valves in patients with severe, symptomatic aortic stenosis who are undergoing transcatheter aortic valve implantation (TAVI).
The main questions it aims to answer are:
Does device success rate (defined by VARC-3 criteria) at 30 days differ between the SAPIEN 3 Ultra Resilia and the Evolut FX valves? Do hemodynamic performance (mean gradient, effective orifice area) and incidence of moderate/severe paravalvular leak differ between the two valve types at 30 days and 1 year? Researchers will compare patients randomized to receive the SAPIEN 3 Ultra Resilia valve versus patients randomized to receive the Evolut FX valve to see if there are differences in device success, safety outcomes, and valve performance.
Participants will:
Undergo standard pre-procedural clinical, echocardiographic, and CT assessment Be randomly assigned to receive either the SAPIEN 3 Ultra Resilia or Evolut FX valve during their clinically indicated TAVI procedure Receive post-procedure follow-up assessments including echocardiography and clinical evaluation at 24 hours, 30 days, 6 months, and 1 year
Detailed description
Study Design Overview
This is a prospective, randomized, controlled, single-blind, two-arm parallel-group trial conducted at a single tertiary cardiac care center. The study aims to compare the latest-generation balloon-expandable transcatheter heart valve (SAPIEN 3 Ultra Resilia) versus the latest-generation self-expanding transcatheter heart valve (Evolut FX) in patients with severe symptomatic aortic stenosis who are deemed appropriate for transcatheter aortic valve implantation (TAVI) by the local heart team.
Scientific Rationale
Previous landmark trials (e.g., PARTNER 3 and Evolut Low Risk) have established the safety and efficacy of TAVI in intermediate- to low-risk patients. However, direct head-to-head comparisons between the newest commercially available valve iterations-the SAPIEN 3 Ultra Resilia (featuring anti-calcification tissue treatment) and the Evolut FX (offering enhanced radial strength and conformability)-are lacking. Observational and registry data suggest potential differences in paravalvular leak rates, hemodynamic performance, and permanent pacemaker implantation rates, but randomized evidence is needed to eliminate bias and guide evidence-based, patient-specific valve selection.
Study Population and Enrollment
Consecutive patients with severe aortic stenosis (aortic valve area ≤1.0 cm², mean gradient ≥40 mmHg, or peak velocity ≥4.0 m/s), symptomatic (NYHA functional class II-IV), and anatomically suitable for both valve types will be screened for eligibility. Key exclusion criteria include bicuspid aortic valve, severe mitral or tricuspid regurgitation, prior aortic valve replacement, active endocarditis, and contraindication to anticoagulation.
A total of approximately 200 patients will be randomized in a 1:1 ratio to receive either the SAPIEN 3 Ultra Resilia or the Evolut FX valve. Sample size calculation assumes a 90% device success rate in both arms, 80% power, and a two-sided alpha of 0.05.
Randomization and Blinding
Randomization will be performed using a computer-generated sequence with variable block sizes. Allocation concealment will be maintained using sequentially numbered, opaque, sealed envelopes. The study is single-blind: outcome assessors and echocardiography core laboratory analysts will be blinded to valve type assignment. Operators and procedural staff cannot be blinded due to the inherent differences in valve delivery systems and deployment techniques.
Procedural and Follow-Up Protocol
All TAVI procedures will be performed according to international standards and local clinical practice. Post-procedure, patients will undergo clinical assessment, 12-lead electrocardiography, and transthoracic echocardiography at 24 hours, 30 days, 6 months, and 1 year. Adverse events will be adjudicated according to Valve Academic Research Consortium-3 (VARC-3) criteria.
Data Management and Statistical Analysis
Data will be collected prospectively using standardized case report forms and entered into a password-protected electronic database. Analysis will be performed using SPSS version 26.0 or later. Continuous variables will be compared using independent t-test or Mann-Whitney U test, and categorical variables using chi-square or Fisher's exact test. Time-to-event outcomes will be analyzed using Kaplan-Meier curves and log-rank tests. A two-sided p-value <0.05 will be considered statistically significant.
Ethical and Regulatory Considerations
The study will be conducted in accordance with the Declaration of Helsinki and Good Clinical Practice guidelines. Ethical approval has been obtained from the institutional review board. Written informed consent will be obtained from all participants prior to any study-related procedures. The trial will be registered on ClinicalTrials.gov prior to enrollment of the first participant. Results will be submitted for publication in a peer-reviewed journal regardless of the outcome.
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- None (open label)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| SAPIEN 3 Ultra Resilia | Active comparator | Device: SAPIEN 3 Ultra ResiliaBalloon-expandable transcatheter aortic valve with anti-calcification tissue treatment. |
| Evolut FX | Active comparator | Device: Evolut FXSelf-expanding transcatheter aortic valve with enhanced radial strength and conformability. |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (7 listed)
- Severe aortic stenosis defined as aortic valve area (AVA) ≤1.0 cm², mean transvalvular gradient ≥40 mmHg, or peak transvalvular velocity ≥4.0 m/s
- Symptomatic with New York Heart Association (NYHA) functional class II, III, or IV
- Heart team consensus that transcatheter aortic valve implantation (TAVI) is the appropriate treatment strategy
- Anatomically suitable for both valve types (SAPIEN 3 Ultra Resilia and Evolut FX) as determined by pre-procedural computed tomography (CT) imaging
- Age ≥18 years
Key exclusion criteria (7 listed)
- Bicuspid aortic valve morphology
- Severe mitral regurgitation or severe tricuspid regurgitation requiring intervention
- Prior surgical or transcatheter aortic valve replacement
- Active infective endocarditis
- Contraindication to dual antiplatelet therapy or anticoagulation
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| SAPIEN 3 Ultra ResiliaBalloon-expandable transcatheter aortic valve featuring anti-calcification tissue treatment. Delivered via transcatheter approach (typically transfemoral) under fluoroscopic guidance. Valve sizes available include 20 mm, 23 mm, 26 mm, and 29 mm. | Device | SAPIEN 3 Ultra Resilia |
| Evolut FXSelf-expanding transcatheter aortic valve with enhanced radial strength and conformability. Features a recapturable and repositionable delivery system. Delivered via transcatheter approach (typically transfemoral). Valve sizes available include 23 mm, 26 mm, 29 mm, and 34 mm. | Device | Evolut FX |
Primary outcome
Device Success Rate at 30 Days
Time frame: 30 days post-procedure
Composite endpoint defined according to Valve Academic Research Consortium-3 (VARC-3) criteria, including: absence of procedural mortality, correct positioning of a single prosthetic heart valve into the proper anatomical location, absence of moderate or severe prosthetic valve regurgitation (paravalvular or central), and acceptable hemodynamic performance (mean aortic valve gradient <20 mmHg or peak velocity <3 m/s)
1 secondary outcome
Mean Aortic Valve Gradient
Time frame: 3 months post-procedure
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 22 Apr 2026.
- Individual participant dataSharing planned: No
Related trials for Severe Aortic Valve Stenosis
Active, not recruiting
Comparison of the Balloon-Expandable Edwards Valve and Self-Expandable CoreValve Evolut R or Evolut PRO System for the Treatment of Small, Severely Dysfunctional Surgical Aortic Bioprotheses. The 'LYTEN' Trial
Aortic Valve Stenosis, Regurgitation, Aortic
Not yet recruiting
Effect of Double-Tap Optimization on Valve Expansion and Hemodynamics in Balloon-expandable Transcatheter Aortic Valve Implantation: A Randomized Clinical Trial (DO-OPT TAVI Trial)
Severe Aortic Stenosis
Active, not recruiting
Target Value Study to Evaluate the Safety and Efficacy of the Taurus NXT® Transcatheter Aortic Valve System for the Treatment of Severe Calcific Aortic Stenosis
Aortic Stenosis
RecruitingObservational study
Spanish Prospective Registry of Hydra THV for Transcatheter Aortic Valve Implantation
Severe Aortic Valve Stenosis, Valvular Heart Disease
RecruitingObservational study
Rare Disease Patient Registry & Natural History Study - Coordination of Rare Diseases at Sanford
Rare Disorders, Undiagnosed Disorders
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing SAPIEN 3 Ultra Resilia and Evolut FX in people with Severe Aortic Valve Stenosis, run by Assiut University at 1 site in Egypt.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 7 inclusion and 7 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: opening soon, as of the sponsor's last update on 22 Apr 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Egypt. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
Contact Ahmed A Hassaan, Assistant Lecturer (+201068115040, ahmed.hassaan1994@aun.edu.eg), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Device Success Rate at 30 Days (time frame: 30 days post-procedure). It is what the study was designed to measure, not a finding.