Liver ResectionNCT07142876
Evaluation Of Liver Resection Using Harmonic Scalpel Versus Cavitron Ultrasonic Surgical Aspirator (CUSA).
A study testing Liver resection Cavitron Ultrasonic Surgical Aspirator (CUSA) and Liver resection with the harmonic scalpel in people with Liver Resection and Liver Tumours, run by Sohag University.
Trial summary
Evaluation Of Liver Resection Using Harmonic Scalpel Versus Cavitron Ultrasonic Surgical Aspirator (CUSA) Introduction The mode of parenchymal transection in hepatic resection has been a topic of great debate for decades. Read more about this study
- Who is it for?
- Ages 6 to 70 years
- Conditions the study is for
- Liver Resection, Liver Tumours, Liver Transplant Disorder
- What is being tested?
- Liver resection Cavitron Ultrasonic Surgical Aspirator (CUSA) and Liver resection with the harmonic scalpel
- Type of treatment
- Surgery or procedure
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 50 participants
- Where
- No sites listed yet
- Study dates
- 22 Aug 2025to 30 Dec 2026
- Phase
- Interventional
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 6 to 70 years
- All sexes
- No healthy volunteers
- Child, Adult, Older adult
Who may be able to join
- patients needing liver resection in normal liver and cirrhotic liver child-pough A and early B
- Age > 6 and < 70 years old
- One or two small (5 cm or less) hepatic lesions confined to the liver with no extra hepatic involvement
- Patients with -ve markers for viral hepatitis
Who cannot join
- patients with age < 6 or > 70 years old
- liver cirrhosis Child-pough C
- liver cell failure
- very large lesions including most of the liver tissue
- hepatic lesions with vascular invasion
- evidence of metastasis in cases with HCC
- patients with +ve markers for viral hepatitis
Trial locations and contacts
No sites are listed yet. Contact the study team or a site near you to ask about taking part.
Mohamed Mahmoud Mohamed Hassanein, Assistant lecturer contact
About this study
Official title: Evaluation Of Liver Resection Using Harmonic Scalpel Versus Cavitron Ultrasonic Surgical Aspirator (CUSA)
Evaluation Of Liver Resection Using Harmonic Scalpel Versus Cavitron Ultrasonic Surgical Aspirator (CUSA)
Introduction The mode of parenchymal transection in hepatic resection has been a topic of great debate for decades. Many resections have now evolved into laparoscopic , and robotic-assisted procedures to limit morbidity. Morbidity and mortality after hepatic resection has progressively improved over the years due to improved equipment, operative technique [3], and anesthetic management. Prior to 1980, mortality rates were reported to be in the 10-20% range with many deaths related to perioperative hemorrhage. Now perioperative mortality has dropped significantly to approximately 5%.
Read more
The clamp-crush technique, first reported in 1974, has been used for decades and remains the standard means of parenchymal division for many surgeons. Control of intraoperative hemorrhage has been one of the principle technical problems in advancing liver surgery. Excess blood loss and intraoperative blood transfusions have been shown to be associated with increased perioperative mortality and morbidity including an increased rate of hepatocellular carcinoma recurrence . Transfusions are also associated with increased infections and with increased cost. Costs of blood transfusions were recently examined in surgical patients.
Many devices are now available to surgeons for division of the liver parenchyma in both open and minimally invasive surgery including: the CUSA (Tyco Healthcare, Mansfield, MA), Harmonic Scalpel (Ethicon Endo-Surgery, Cincinnati, OH, USA), Ligasure (Valley Lab, Tyco Healthcare, Boulder, CO, USA), Tissue Link (Salient Surgical Technologies, Portsmouth, NH), water-jet dissection, radiofrequency, microwave assisted resection, vascular staplers, and others In this study, we looked at the TissueLink bipolar sealer device that was used in combination with the CUSA in group 1 termed the CUSA/TissueLink group, and the Harmonic Scalpel in the group 2 termed Harmonic Scalpel/TissueLink. The TissueLink uses radiofrequency energy focused near the end of the device for electrocautery and a low volume saline drip that produces ohmic heat causing precoagulation of hepatic parenchyma. The saline keeps the temperature at or below 100 C to avoid eshcar formation ultimately helping prevent delayed biliary leak and hemorrhage. The hemostatic effects of TissueLink are a result of its disruption of the collagen in blood vessels causing closing of the lumen .
The CUSA, a commonly used device in hepatic resection, was used in combination with the TissueLink in this study. We previously described this combination of devices reporting a shorter length of hospital stay, decreased operative time, and decreased intraoperative blood transfusion . CUSA uses ultrasonic energy to fragment and aspirate parenchymal tissue. This exposes biliary as well as vascular structures that may then be closed in a variety of ways at the surgeon's discretion. It allows for a precise transection plane allowing preservation of normal hepatic tissue .
The Harmonic Scalpel, used in this study in combination with the TissueLink, utilizes ultrasonic vibration of two blades causing destruction of hydrogen bonds. This disruption of hydrogen bonds causes protein denaturization coagulating small vessels of 3 mm diameter. The parenchyma is also cut when the blades move in a saw-like fashion In this study, we evaluated the safety and efficacy of two different techniques described above for the division of the hepatic parenchyma in order to improve perioperative outcomes.
Read the detailed description
Evaluation Of Liver Resection Using Harmonic Scalpel Versus Cavitron Ultrasonic Surgical Aspirator (CUSA)
Introduction The mode of parenchymal transection in hepatic resection has been a topic of great debate for decades. Many resections have now evolved into laparoscopic , and robotic-assisted procedures to limit morbidity. Morbidity and mortality after hepatic resection has progressively improved over the years due to improved equipment, operative technique [3], and anesthetic management. Prior to 1980, mortality rates were reported to be in the 10-20% range with many deaths related to perioperative hemorrhage. Now perioperative mortality has dropped significantly to approximately 5%.
The clamp-crush technique, first reported in 1974, has been used for decades and remains the standard means of parenchymal division for many surgeons. Control of intraoperative hemorrhage has been one of the principle technical problems in advancing liver surgery. Excess blood loss and intraoperative blood transfusions have been shown to be associated with increased perioperative mortality and morbidity including an increased rate of hepatocellular carcinoma recurrence . Transfusions are also associated with increased infections and with increased cost. Costs of blood transfusions were recently examined in surgical patients.
Many devices are now available to surgeons for division of the liver parenchyma in both open and minimally invasive surgery including: the CUSA (Tyco Healthcare, Mansfield, MA), Harmonic Scalpel (Ethicon Endo-Surgery, Cincinnati, OH, USA), Ligasure (Valley Lab, Tyco Healthcare, Boulder, CO, USA), Tissue Link (Salient Surgical Technologies, Portsmouth, NH), water-jet dissection, radiofrequency, microwave assisted resection, vascular staplers, and others In this study, we looked at the TissueLink bipolar sealer device that was used in combination with the CUSA in group 1 termed the CUSA/TissueLink group, and the Harmonic Scalpel in the group 2 termed Harmonic Scalpel/TissueLink. The TissueLink uses radiofrequency energy focused near the end of the device for electrocautery and a low volume saline drip that produces ohmic heat causing precoagulation of hepatic parenchyma. The saline keeps the temperature at or below 100 C to avoid eshcar formation ultimately helping prevent delayed biliary leak and hemorrhage. The hemostatic effects of TissueLink are a result of its disruption of the collagen in blood vessels causing closing of the lumen .
The CUSA, a commonly used device in hepatic resection, was used in combination with the TissueLink in this study. We previously described this combination of devices reporting a shorter length of hospital stay, decreased operative time, and decreased intraoperative blood transfusion . CUSA uses ultrasonic energy to fragment and aspirate parenchymal tissue. This exposes biliary as well as vascular structures that may then be closed in a variety of ways at the surgeon's discretion. It allows for a precise transection plane allowing preservation of normal hepatic tissue .
The Harmonic Scalpel, used in this study in combination with the TissueLink, utilizes ultrasonic vibration of two blades causing destruction of hydrogen bonds. This disruption of hydrogen bonds causes protein denaturization coagulating small vessels of 3 mm diameter. The parenchyma is also cut when the blades move in a saw-like fashion In this study, we evaluated the safety and efficacy of two different techniques described above for the division of the hepatic parenchyma in order to improve perioperative outcomes.
Aim Of the Work This study was conducted aiming to assess the efficacy and safety of liver resection using Harmonic Scalpel Versus cavitron Ultrasonic Surgical Aspirator (CUSA)
Patients and methods The study design: prospective randomized comparative clinical trial study analyzing outcomes of liver resection by two different techniques CUSA or Harmonic scalpel .This will be a prospective comparative study at Sohag University Hospital and Assuit University Hospital, Egypt The study population was divided into two equal groups (25 per group) according to the method of liver transection: group A by CUSA and group B by harmonic scalpel (HS).
Inclusion criteria patients needing liver resection in normal liver and cirrhotic liver child-pough A and early B with: Age > 6 and < 70 years old, One or two small (5 cm or less) hepatic lesions confined to the liver with no extra hepatic involvement, Patients with -ve markers for viral hepatitis.
The exclusion criteria:
patients with age < 6 or > 70 years old, liver cirrhosis Child-pough C, liver cell failure, very large lesions including most of the liver tissue, hepatic lesions with vascular invasion, evidence of metastasis in cases with HCC, and patients with +ve markers for viral hepatitis.
Approvals and consents This study will be done after obtaining approval from the research ethics committee of the Sohag faculty of medicine. A written Informed consent will be obtained from all participants before being enrolled in the study and before performing the procedure after receiving an explanation of the study protocol, including both types of operation and possible complications.
The study will be registered at www.clinicaltrials.gov.
Data collection:
Registered data will be collected from the hospital databases, clinical data. Setting This study will be performed in Sohag University Hospital and Assuit University Hospital.
All operations will be performed under general anesthesia.
Preoperative:
All Patients underwent the following: Complete history taking and clinical examination focusing on: presenting symptoms, symptoms of chronic liver diseases (chronic hepatitis, liver cirrhosis) and jaundice, history of any preceding disease or previous operations and history of travelling to endemic areas. Laboratory investigation: Complete blood picture, Liver function tests: Albumin, bilirubin, ALT, AST, Coagulation profile, Renal function tests and Tumor markers: Alpha fetoprotein (AFP), CEA, and CA 19-9. Radiological evaluation: Abdominal ultrasound and Tri-phasic CT with hepatic venography, arteriography, portography and magnetic resonance cholangiopancreatography (MRCP) and residual liver volume must be more than or equals to 35%. ERCP: was performed in patients presented clinically with jaundice.
Surgical technique:
The procedure was performed through a right inverted J-shaped incision. Following laparotomy, liver mobilization and piggyback were done in the standard technique then an intra-operative ultrasound and cholangiogram were done to define the major biliary system anatomy and vasculature.
Transection of the liver parenchyma started from the anterocaudal liver surface toward the hepatic veins. The line of parenchymal transection was mapped about 1 cm to the right of the middle hepatic vein (MHV) using intraoperative Doppler ultrasound. The clearly exposed vessels (More than 5mm) were ligated by 4/0 or 5/0 polyprolene or clipped with preservation of V5 and V8.
In-group A Cavitron Ultrasonic Surgical Settings Aspirator (CUSA) with standard tip was used for parenchymal transection with the following Settings; 23 kHz, 70 Watt, and continuous irrigation at rate of 4-6 ml/min with normal saline and the vessel coagulation was performed by the bipolar sealer (Valleylab force FX electrosurgical generator, Medtronic, Minneapolis, USA), the power was used at 50 Watt coagulation.
In group B the harmonic scalpel (Ethicon EndoSurgery, Johnson \& Johnson, New Jersey, USA) was set at a high power, and blood vessels or bile ducts up to 3-4 mm in diameter were coagulated for 5-6 seconds.
Following completion cholangiogram, open-suction silicon drain was placed into the subphrenic and subhepatic spaces close to the cut surface of the liver before abdominal wound closure.
Blood loss during parenchymal transection and immediately after hepatectomy until completion of the procedures was included and estimated by the volume of blood suctioned and subtraction of rinse fluids and/or weighting the swabs that were used during transection, (Every 1 mL of blood is equivalent to 1 g increase in the swab weight).
Postoperative bile leakage was diagnosed once bile was detected from the wound or the drain or drained intra-abdominal collection with total bilirubin level in the fluid more than 3 times that in the serum.
The liver resection time was defined as the duration from the beginning of parenchymal transection until the completion of transection with complete achievement of haemostasis from the liver cut surface.
Post-operative management All patients were admitted to the ICU for early post-operative care. Post-operative parameters of hepatic recovery, including serum total bilirubin, ALT, AST, prothrombin time, albumin, was measured daily until discharge from ICU then every other day till discharge.
The drain was removed when the amount drained was less than 100 mL/day and no bile leak and discharge from the hospital was based on the patient's general condition, clinical parameters, complications and abdominal ultrasound.
Follow-Up Upon discharge, all patients were followed once weekly with abdominal ultrasound together with routine laboratory data for at least 1 month.
- Being tested
- Liver resection Cavitron Ultrasonic Surgical Aspirator (CUSA), Liver resection with the harmonic scalpel
- Keywords
- liver resection, CUSA, Cavitron Ultrasonic Surgical Aspirator, Harmonic
- Medical subject headings
- Carcinoma, Hepatocellular, Abdominal Injuries
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Liver resection Cavitron Ultrasonic Surgical Aspirator (CUSA)Procedure or surgery
Also called Group A
In-group A Cavitron Ultrasonic Surgical Settings Aspirator (CUSA) with standard tip was used for parenchymal transection with the following Settings; 23 kHz, 70 Watt, and continuous irrigation at rate of 4-6 ml/min with normal saline and the vessel coagulation was performed by the bipolar sealer (Valleylab force FX electrosurgical generator, Medtronic, Minneapolis, USA), the power was used at 50 Watt coagulation.
Liver resection with the harmonic scalpelProcedure or surgery
Also called Group B
In group B the harmonic scalpel (Ethicon EndoSurgery, Johnson \& Johnson, New Jersey, USA) was set at a high power, and blood vessels or bile ducts up to 3-4 mm in diameter were coagulated for 5-6 seconds.
| Study group | Role | What they receive |
|---|---|---|
| Liver resection with Cavitron Ultrasonic Surgical Settings Aspirator (CUSA) | Active comparator | In-group A Cavitron Ultrasonic Surgical Settings Aspirator (CUSA) with standard tip was used for parenchymal transection with the following Settings; 23 kHz, 70 Watt, and continuous irrigation at rate of 4-6 ml/min with normal saline and the vessel coagulation was performed by the bipolar sealer (Valleylab force FX electrosurgical generator, Medtronic, Minneapolis, USA), the power was used at 50 Watt coagulation. Receives: Procedure: Liver resection Cavitron Ultrasonic Surgical Aspirator (CUSA) |
| Liver resection with the harmonic scalpel | Active comparator | In group B the harmonic scalpel (Ethicon EndoSurgery, Johnson \& Johnson, New Jersey, USA) was set at a high power, and blood vessels or bile ducts up to 3-4 mm in diameter were coagulated for 5-6 seconds. Receives: Procedure: Liver resection with the harmonic scalpel |
What is being measured
The primary outcome is the main question the study is designed to answer.
Postoperative bile leakage
Postoperative bile leakage was diagnosed once bile was detected from the wound or the drain or drained intra-abdominal collection with total bilirubin level in the fluid more than 3 times that in the serum.
Measured: Day 14
The liver resection time
The liver resection time was defined as the duration from the beginning of parenchymal transection until the completion of transection with complete achievement of haemostasis from the liver cut surface.
Measured: Day 1
Blood loss
Blood loss during parenchymal transection and immediately after hepatectomy until completion of the procedures was included and estimated by the volume of blood suctioned and subtraction of rinse fluids and/or weighting the swabs that were used during transection, (Every 1 mL of blood is equivalent to 1 g increase in the swab weight).
Measured: Day 1
Secondary outcomes (1)
liver functions
Post-operative parameters of hepatic recovery, including serum total bilirubin, ALT, AST, prothrombin time, albumin, was measured daily until discharge from ICU then every other day till discharge.
Measured: Day 14
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted27 Aug 2025
- Study start22 Aug 2025 (estimated)
- Primary completion1 Nov 2026 (estimated)
- Study completion30 Dec 2026 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Liver ResectionStudies of the same condition, open and under way.
- More trials run by Sohag UniversityThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Factorial
- Model description
- prospective randomized comparative clinical trial study analyzing outcomes of liver resection by two different techniques CUSA or Harmonic scalpel .This will be a prospective comparative study at Sohag University Hospital and Assuit University Hospital, Egypt The study population was divided into two equal groups (25 per group) according to the method of liver transection: group A by CUSA and group B by harmonic scalpel (HS). Inclusion criteria patients needing liver resection in normal liver and cirrhotic liver child-pough A and early B with: Age \> 6 and \< 70 years old, One or two small (5 cm or less) hepatic lesions confined to the liver with no extra hepatic involvement, Patients with -ve markers for viral hepatitis. The exclusion criteria: patients with age \< 6 or \> 70 years old, liver cirrhosis Child-pough C, liver cell failure, very large lesions including most of the liver tissue, vascular invasion, evidence of metastasis in cases with HCC, positive hepatitis
- Masking
- None (open label)
- Enrolment
- 50 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Sohag University
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Mohamed Mahmoud Mohamed Elzeer, Sohag University
- Investigators
- AbdElaal A Prof. AbdElaal Ali Sleem, professor, Study chair, AbdElaal Ali Sleem
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT07142876
- Sponsor's protocol ID
- Soh-Med-25-8-5MD
- Status last verified
- Aug 2025
- First submitted
- 19 Aug 2025
- Last updated
- 27 Aug 2025
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No: protecting my patients privacy and confidentiality
Study at a glance
From the registry record, last updated by the sponsor on 27 Aug 2025. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Evaluation Of Liver Resection Using Harmonic Scalpel Versus Cavitron Ultrasonic Surgical Aspirator (CUSA)
- ClinicalTrials.gov ID
- NCT07142876
- Acronym / sponsor ID
- Soh-Med-25-8-5MD
- Keywords
- liver resection, CUSA, Cavitron Ultrasonic Surgical Aspirator, Harmonic
- Study type
- Interventional
- Recruitment status
- Not yet recruiting
- Enrolment
- 50 participants (estimated)
- Lead sponsor
- Sohag UniversityUniversity, hospital or other
- Study start
- 22 Aug 2025 (estimated)
- Primary completion
- 1 Nov 2026 (estimated)
- Study completion
- 30 Dec 2026 (estimated)
- First posted
- 27 Aug 2025 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Evaluation Of Liver Resection Using Harmonic Scalpel Versus Cavitron Ultrasonic Surgical Aspirator (CUSA)
Introduction The mode of parenchymal transection in hepatic resection has been a topic of great debate for decades. Many resections have now evolved into laparoscopic , and robotic-assisted procedures to limit morbidity. Morbidity and mortality after hepatic resection has progressively improved over the years due to improved equipment, operative technique [3], and anesthetic management. Prior to 1980, mortality rates were reported to be in the 10-20% range with many deaths related to perioperative hemorrhage. Now perioperative mortality has dropped significantly to approximately 5%.
The clamp-crush technique, first reported in 1974, has been used for decades and remains the standard means of parenchymal division for many surgeons. Control of intraoperative hemorrhage has been one of the principle technical problems in advancing liver surgery. Excess blood loss and intraoperative blood transfusions have been shown to be associated with increased perioperative mortality and morbidity including an increased rate of hepatocellular carcinoma recurrence . Transfusions are also associated with increased infections and with increased cost. Costs of blood transfusions were recently examined in surgical patients.
Many devices are now available to surgeons for division of the liver parenchyma in both open and minimally invasive surgery including: the CUSA (Tyco Healthcare, Mansfield, MA), Harmonic Scalpel (Ethicon Endo-Surgery, Cincinnati, OH, USA), Ligasure (Valley Lab, Tyco Healthcare, Boulder, CO, USA), Tissue Link (Salient Surgical Technologies, Portsmouth, NH), water-jet dissection, radiofrequency, microwave assisted resection, vascular staplers, and others In this study, we looked at the TissueLink bipolar sealer device that was used in combination with the CUSA in group 1 termed the CUSA/TissueLink group, and the Harmonic Scalpel in the group 2 termed Harmonic Scalpel/TissueLink. The TissueLink uses radiofrequency energy focused near the end of the device for electrocautery and a low volume saline drip that produces ohmic heat causing precoagulation of hepatic parenchyma. The saline keeps the temperature at or below 100 C to avoid eshcar formation ultimately helping prevent delayed biliary leak and hemorrhage. The hemostatic effects of TissueLink are a result of its disruption of the collagen in blood vessels causing closing of the lumen .
The CUSA, a commonly used device in hepatic resection, was used in combination with the TissueLink in this study. We previously described this combination of devices reporting a shorter length of hospital stay, decreased operative time, and decreased intraoperative blood transfusion . CUSA uses ultrasonic energy to fragment and aspirate parenchymal tissue. This exposes biliary as well as vascular structures that may then be closed in a variety of ways at the surgeon's discretion. It allows for a precise transection plane allowing preservation of normal hepatic tissue .
The Harmonic Scalpel, used in this study in combination with the TissueLink, utilizes ultrasonic vibration of two blades causing destruction of hydrogen bonds. This disruption of hydrogen bonds causes protein denaturization coagulating small vessels of 3 mm diameter. The parenchyma is also cut when the blades move in a saw-like fashion In this study, we evaluated the safety and efficacy of two different techniques described above for the division of the hepatic parenchyma in order to improve perioperative outcomes.
Detailed description
Evaluation Of Liver Resection Using Harmonic Scalpel Versus Cavitron Ultrasonic Surgical Aspirator (CUSA)
Introduction The mode of parenchymal transection in hepatic resection has been a topic of great debate for decades. Many resections have now evolved into laparoscopic , and robotic-assisted procedures to limit morbidity. Morbidity and mortality after hepatic resection has progressively improved over the years due to improved equipment, operative technique [3], and anesthetic management. Prior to 1980, mortality rates were reported to be in the 10-20% range with many deaths related to perioperative hemorrhage. Now perioperative mortality has dropped significantly to approximately 5%.
The clamp-crush technique, first reported in 1974, has been used for decades and remains the standard means of parenchymal division for many surgeons. Control of intraoperative hemorrhage has been one of the principle technical problems in advancing liver surgery. Excess blood loss and intraoperative blood transfusions have been shown to be associated with increased perioperative mortality and morbidity including an increased rate of hepatocellular carcinoma recurrence . Transfusions are also associated with increased infections and with increased cost. Costs of blood transfusions were recently examined in surgical patients.
Many devices are now available to surgeons for division of the liver parenchyma in both open and minimally invasive surgery including: the CUSA (Tyco Healthcare, Mansfield, MA), Harmonic Scalpel (Ethicon Endo-Surgery, Cincinnati, OH, USA), Ligasure (Valley Lab, Tyco Healthcare, Boulder, CO, USA), Tissue Link (Salient Surgical Technologies, Portsmouth, NH), water-jet dissection, radiofrequency, microwave assisted resection, vascular staplers, and others In this study, we looked at the TissueLink bipolar sealer device that was used in combination with the CUSA in group 1 termed the CUSA/TissueLink group, and the Harmonic Scalpel in the group 2 termed Harmonic Scalpel/TissueLink. The TissueLink uses radiofrequency energy focused near the end of the device for electrocautery and a low volume saline drip that produces ohmic heat causing precoagulation of hepatic parenchyma. The saline keeps the temperature at or below 100 C to avoid eshcar formation ultimately helping prevent delayed biliary leak and hemorrhage. The hemostatic effects of TissueLink are a result of its disruption of the collagen in blood vessels causing closing of the lumen .
The CUSA, a commonly used device in hepatic resection, was used in combination with the TissueLink in this study. We previously described this combination of devices reporting a shorter length of hospital stay, decreased operative time, and decreased intraoperative blood transfusion . CUSA uses ultrasonic energy to fragment and aspirate parenchymal tissue. This exposes biliary as well as vascular structures that may then be closed in a variety of ways at the surgeon's discretion. It allows for a precise transection plane allowing preservation of normal hepatic tissue .
The Harmonic Scalpel, used in this study in combination with the TissueLink, utilizes ultrasonic vibration of two blades causing destruction of hydrogen bonds. This disruption of hydrogen bonds causes protein denaturization coagulating small vessels of 3 mm diameter. The parenchyma is also cut when the blades move in a saw-like fashion In this study, we evaluated the safety and efficacy of two different techniques described above for the division of the hepatic parenchyma in order to improve perioperative outcomes.
Aim Of the Work This study was conducted aiming to assess the efficacy and safety of liver resection using Harmonic Scalpel Versus cavitron Ultrasonic Surgical Aspirator (CUSA)
Patients and methods The study design: prospective randomized comparative clinical trial study analyzing outcomes of liver resection by two different techniques CUSA or Harmonic scalpel .This will be a prospective comparative study at Sohag University Hospital and Assuit University Hospital, Egypt The study population was divided into two equal groups (25 per group) according to the method of liver transection: group A by CUSA and group B by harmonic scalpel (HS).
Inclusion criteria patients needing liver resection in normal liver and cirrhotic liver child-pough A and early B with: Age > 6 and < 70 years old, One or two small (5 cm or less) hepatic lesions confined to the liver with no extra hepatic involvement, Patients with -ve markers for viral hepatitis.
The exclusion criteria:
patients with age < 6 or > 70 years old, liver cirrhosis Child-pough C, liver cell failure, very large lesions including most of the liver tissue, hepatic lesions with vascular invasion, evidence of metastasis in cases with HCC, and patients with +ve markers for viral hepatitis.
Approvals and consents This study will be done after obtaining approval from the research ethics committee of the Sohag faculty of medicine. A written Informed consent will be obtained from all participants before being enrolled in the study and before performing the procedure after receiving an explanation of the study protocol, including both types of operation and possible complications.
The study will be registered at www.clinicaltrials.gov.
Data collection:
Registered data will be collected from the hospital databases, clinical data. Setting This study will be performed in Sohag University Hospital and Assuit University Hospital.
All operations will be performed under general anesthesia.
Preoperative:
All Patients underwent the following: Complete history taking and clinical examination focusing on: presenting symptoms, symptoms of chronic liver diseases (chronic hepatitis, liver cirrhosis) and jaundice, history of any preceding disease or previous operations and history of travelling to endemic areas. Laboratory investigation: Complete blood picture, Liver function tests: Albumin, bilirubin, ALT, AST, Coagulation profile, Renal function tests and Tumor markers: Alpha fetoprotein (AFP), CEA, and CA 19-9. Radiological evaluation: Abdominal ultrasound and Tri-phasic CT with hepatic venography, arteriography, portography and magnetic resonance cholangiopancreatography (MRCP) and residual liver volume must be more than or equals to 35%. ERCP: was performed in patients presented clinically with jaundice.
Surgical technique:
The procedure was performed through a right inverted J-shaped incision. Following laparotomy, liver mobilization and piggyback were done in the standard technique then an intra-operative ultrasound and cholangiogram were done to define the major biliary system anatomy and vasculature.
Transection of the liver parenchyma started from the anterocaudal liver surface toward the hepatic veins. The line of parenchymal transection was mapped about 1 cm to the right of the middle hepatic vein (MHV) using intraoperative Doppler ultrasound. The clearly exposed vessels (More than 5mm) were ligated by 4/0 or 5/0 polyprolene or clipped with preservation of V5 and V8.
In-group A Cavitron Ultrasonic Surgical Settings Aspirator (CUSA) with standard tip was used for parenchymal transection with the following Settings; 23 kHz, 70 Watt, and continuous irrigation at rate of 4-6 ml/min with normal saline and the vessel coagulation was performed by the bipolar sealer (Valleylab force FX electrosurgical generator, Medtronic, Minneapolis, USA), the power was used at 50 Watt coagulation.
In group B the harmonic scalpel (Ethicon EndoSurgery, Johnson \& Johnson, New Jersey, USA) was set at a high power, and blood vessels or bile ducts up to 3-4 mm in diameter were coagulated for 5-6 seconds.
Following completion cholangiogram, open-suction silicon drain was placed into the subphrenic and subhepatic spaces close to the cut surface of the liver before abdominal wound closure.
Blood loss during parenchymal transection and immediately after hepatectomy until completion of the procedures was included and estimated by the volume of blood suctioned and subtraction of rinse fluids and/or weighting the swabs that were used during transection, (Every 1 mL of blood is equivalent to 1 g increase in the swab weight).
Postoperative bile leakage was diagnosed once bile was detected from the wound or the drain or drained intra-abdominal collection with total bilirubin level in the fluid more than 3 times that in the serum.
The liver resection time was defined as the duration from the beginning of parenchymal transection until the completion of transection with complete achievement of haemostasis from the liver cut surface.
Post-operative management All patients were admitted to the ICU for early post-operative care. Post-operative parameters of hepatic recovery, including serum total bilirubin, ALT, AST, prothrombin time, albumin, was measured daily until discharge from ICU then every other day till discharge.
The drain was removed when the amount drained was less than 100 mL/day and no bile leak and discharge from the hospital was based on the patient's general condition, clinical parameters, complications and abdominal ultrasound.
Follow-Up Upon discharge, all patients were followed once weekly with abdominal ultrasound together with routine laboratory data for at least 1 month.
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Factorial
- Masking
- None (open label)
- Number of arms
- 2
- Model description
- prospective randomized comparative clinical trial study analyzing outcomes of liver resection by two different techniques CUSA or Harmonic scalpel .This will be a prospective comparative study at Sohag University Hospital and Assuit University Hospital, Egypt The study population was divided into two equal groups (25 per group) according to the method of liver transection: group A by CUSA and group B by harmonic scalpel (HS). Inclusion criteria patients needing liver resection in normal liver and cirrhotic liver child-pough A and early B with: Age > 6 and < 70 years old, One or two small (5 cm or less) hepatic lesions confined to the liver with no extra hepatic involvement, Patients with -ve markers for viral hepatitis. The exclusion criteria: patients with age < 6 or > 70 years old, liver cirrhosis Child-pough C, liver cell failure, very large lesions including most of the liver tissue, vascular invasion, evidence of metastasis in cases with HCC, positive hepatitis
| Arm | Type | Receives |
|---|---|---|
| Liver resection with Cavitron Ultrasonic Surgical Settings Aspirator (CUSA) | Active comparator | Procedure: Liver resection Cavitron Ultrasonic Surgical Aspirator (CUSA)In-group A Cavitron Ultrasonic Surgical Settings Aspirator (CUSA) with standard tip was used for parenchymal transection with the following Settings; 23 kHz, 70 Watt, and continuous irrigation at rate of 4-6 ml/min with normal saline and the vessel coagulation was performed by the bipolar sealer (Valleylab force FX electrosurgical generator, Medtronic, Minneapolis, USA), the power was used at 50 Watt coagulation. |
| Liver resection with the harmonic scalpel | Active comparator | Procedure: Liver resection with the harmonic scalpelIn group B the harmonic scalpel (Ethicon EndoSurgery, Johnson \& Johnson, New Jersey, USA) was set at a high power, and blood vessels or bile ducts up to 3-4 mm in diameter were coagulated for 5-6 seconds. |
Who may qualify
- Ages
- 6 to 70 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Child, Adult, Older adult
Key inclusion criteria (4 listed)
- patients needing liver resection in normal liver and cirrhotic liver child-pough A and early B
- Age > 6 and < 70 years old
- One or two small (5 cm or less) hepatic lesions confined to the liver with no extra hepatic involvement
- Patients with -ve markers for viral hepatitis
Key exclusion criteria (7 listed)
- patients with age < 6 or > 70 years old
- liver cirrhosis Child-pough C
- liver cell failure
- very large lesions including most of the liver tissue
- hepatic lesions with vascular invasion
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Liver resection Cavitron Ultrasonic Surgical Aspirator (CUSA)Also: Group AIn-group A Cavitron Ultrasonic Surgical Settings Aspirator (CUSA) with standard tip was used for parenchymal transection with the following Settings; 23 kHz, 70 Watt, and continuous irrigation at rate of 4-6 ml/min with normal saline and the vessel coagulation was performed by the bipolar sealer (Valleylab force FX electrosurgical generator, Medtronic, Minneapolis, USA), the power was used at 50 Watt coagulation. | Procedure or surgery | Liver resection with Cavitron Ultrasonic Surgical Settings Aspirator (CUSA) |
| Liver resection with the harmonic scalpelAlso: Group BIn group B the harmonic scalpel (Ethicon EndoSurgery, Johnson \& Johnson, New Jersey, USA) was set at a high power, and blood vessels or bile ducts up to 3-4 mm in diameter were coagulated for 5-6 seconds. | Procedure or surgery | Liver resection with the harmonic scalpel |
Primary outcome
Postoperative bile leakage
Time frame: Day 14
Postoperative bile leakage was diagnosed once bile was detected from the wound or the drain or drained intra-abdominal collection with total bilirubin level in the fluid more than 3 times that in the serum.
The liver resection time
Time frame: Day 1
The liver resection time was defined as the duration from the beginning of parenchymal transection until the completion of transection with complete achievement of haemostasis from the liver cut surface.
Blood loss
Time frame: Day 1
Blood loss during parenchymal transection and immediately after hepatectomy until completion of the procedures was included and estimated by the volume of blood suctioned and subtraction of rinse fluids and/or weighting the swabs that were used during transection, (Every 1 mL of blood is equivalent to 1 g increase in the swab weight).
1 secondary outcome
liver functions
Time frame: Day 14
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 27 Aug 2025.
- Individual participant dataSharing planned: No. protecting my patients privacy and confidentiality
Related trials for Liver Resection
Not yet recruitingPhase 2
NIVO+IPI Neoadjuvant Therapy for Recurrent Resectable HCC
Hepatocellular Carcinoma (HCC), Recurrent Hepatocellular Cancer
Not yet recruiting
RAPID for Unresectable Colorectal Liver Metastases
Colorectal Liver Metastases (CRCLM), Colorectal Neoplasms
RecruitingPhase 4
Remimazolam Versus Propofol for Maintenance of Anaesthesia During Major Hepatectomy Under Low Central Venous Pressure
Intraoperative Hypotension, Hepatectomy
RecruitingPhase 2
Circulating Tumor DNA Methylation-Guided Adjuvant Therapy Decision-Making in Patients With Resectable Colorectal Cancer Liver Metastases After Resection
Colorectal Cancer Liver Metastases (CRLM), ctDNA
Recruiting
Implementation of a Pain Management Plan in Major Open Abdominal Surgeries.
Abdomen Cancer, Pancreas Adenocarcinoma (MSI-H)
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part.
Mohamed Mahmoud Mohamed Hassanein, Assistant lecturer contact
AbdElaal A Prof. AbdElaal Ali Sleem, professor study chair
AbdElaal Ali Sleem
Questions about this trial
What is this clinical trial studying?
A study testing Liver resection Cavitron Ultrasonic Surgical Aspirator (CUSA) and Liver resection with the harmonic scalpel in people with Liver Resection and Liver Tumours, run by Sohag University.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 4 inclusion and 7 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: opening soon, as of the sponsor's last update on 27 Aug 2025. Status can change between updates, so confirm with the study contact before making plans.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
Contact Mohamed Mahmoud Mohamed Hassanein, Assistant lecturer (+201099827891 ext. +201099827891, mohamed_elzeer@med.sohag.edu.eg), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Postoperative bile leakage (time frame: Day 14). The study lists 3 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 27 Aug 2025.