Endotracheal Tube CuffNCT07017205

Microaspiration and Endotracheal Tubes

A study testing Application of oropharyngeal dye and tracheal aspirate collection in people with Endotracheal Tube Cuff and Microaspiration, run by Argentinian Intensive Care Society at 1 site in Argentina.

Not yet recruiting

Opening soon. The study is approved but enrolment has not started yet. Sites may already take enquiries.

Sites and contacts
Official record
Search all trials

Trial summary

The goal of this clinical trial is to learn if a new method for managing breathing tube pressure is better at preventing fluid from leaking into patients' lungs during surgery. It will also check if it causes fewer side effects like a sore throat. Read more about this study

Who is it for?
Ages 18 years and older
What is being tested?
Application of oropharyngeal dye and tracheal aspirate collection
Could I receive a placebo?
No, everyone receives an active treatment
How many people
72 participants
Where
1 siteArgentina
Study dates
1 Feb 2026to 31 May 2026
Phase
Interventional
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Adult patients (>18 years old) scheduled for surgery lasting at least one hour.
  • ASA I-III classification.
  • Signed informed consent.

Who cannot join

  • Pre-existing airway pathology (e.g., tracheomalacia, granulomas, stenosis, tumors).
  • Anticipated difficult intubation (Macocha Score > 3 points).
  • Selective lung ventilation / one-lung ventilation.
  • Current participation in another clinical trial.
  • Elimination Criteria:
  • Accidental extubation.
  • Cardiorespiratory arrest or death.

Trial locations and contacts

1 site in 1 country. Contact the study team or a site near you to ask about taking part.

Gustavo A Plotnikow, BPT; BCs ICU; PhD(c) contact

+5491164543771

gplotnikow@hbritanico.com.ar

Argentina1 site
  • Hospital Britanico de Buenos Aires

    CABA, Buenos Aires, 1280

    Gustavo A Plotnikow, +5491164543771, gplotnikow@hbritanico.com.ar

Other trials in Argentina

About this study

Official title: Automated Versus Manual Cuff Pressure Control for Preventing Microaspiration With TaperGuard Endotracheal Tubes in Elective Surgery: A Randomized Controlled Trial

The goal of this clinical trial is to learn if a new method for managing breathing tube pressure is better at preventing fluid from leaking into patients' lungs during surgery. It will also check if it causes fewer side effects like a sore throat.

The main questions it aims to answer are:

Read more

Does using a continuous pressure controller reduce fluid leakage past the breathing tube cuff compared to the standard manual method? Does the continuous pressure controller lead to fewer and less severe sore throats and voice changes after surgery?

Researchers will compare two groups:

Group 1: Patients whose breathing tube cuff pressure is managed with a continuous automatic controller.

Group 2: Patients whose breathing tube cuff pressure is managed with the standard manual method.

Participants will:

Be randomly assigned to one of the two groups before their surgery. Receive a small, safe amount of blue dye in their mouth during the procedure to help measure leakage.

Have two small secretion samples collected from their breathing tube during surgery.

Be asked about sore throat and voice changes at 1, 2, 3, and 24 hours after the breathing tube is removed.

Read the detailed description
  1. The Clinical Challenge: Microaspiration and the Breathing Tube Endotracheal intubation is a life-saving procedure, but it inherently bypasses the body's natural defenses against lung infection. A critical, yet often overlooked, problem is microaspiration. This is the silent leakage of small amounts of oropharyngeal secretions past the cuff of the breathing tube and into the lower airways and lungs. This phenomenon is a primary contributor to the development of Ventilator-Associated Pneumonia (VAP), a serious complication that increases patient morbidity, mortality, and healthcare costs. The cuff's primary role is to create a seal within the trachea. However, conventional cylindrical cuffs can form folds or channels when inflated, creating a direct pathway for secretions to leak through. Furthermore, maintaining the correct cuff pressure (recommended 25-30 cmH₂O) is challenging; pressure can fluctuate due to patient movement, changes in anesthesia gas volume, and surgical positioning.
  2. Technological Innovations and the Evidence Gap To address these issues, manufacturers have developed advanced endotracheal tubes. This study focuses on the TaperGuard™ Evac tube (Covidien/Medtronic), which features a uniquely shaped tapered cuff. This design is intended to inflate more uniformly against the tracheal wall, theoretically reducing the formation of leakage channels compared to traditional cylindrical cuffs. Concurrently, technology for pressure management has evolved. While the current standard of care involves intermittent manual checks with a manometer, automated cuff pressure controllers (like the Pressure Easy® device) have been introduced. These devices continuously monitor and adjust the pressure, maintaining it within a pre-set target range throughout the entire procedure without manual intervention. While laboratory (bench-top) studies strongly suggest that tapered cuffs are superior at preventing fluid leakage, and some early clinical studies are promising, there is a lack of robust, in-vivo evidence from a controlled surgical setting. This study aims to fill that gap by directly testing the combined effect of the advanced tube design with two different levels of pressure management sophistication.
  3. The Study's Core Investigation: A Two-Factor Comparison This trial is not just testing a new device, but rather investigating a clinical management strategy. The central question is: Does moving from a manual, intermittent pressure management protocol to a continuous, automated one provide a significant clinical benefit when using a modern, tapered-cuff endotracheal tube? To answer this, we are employing a rigorous model to objectively quantify microaspiration: The Blue Dye Model: A small, safe volume of blue dye is instilled into the patient's oropharynx above the cuff after intubation. The presence or absence of this dye in tracheal aspirate samples, collected later from below the cuff, serves as an objective, binary measure (Yes/No) of whether leakage has occurred.
  4. Broader Impact and Secondary Patient-Centered Outcomes Beyond the primary goal of preventing pneumonia, the study also investigates patient comfort and safety post-operatively. Damage to the tracheal mucosa from improper cuff pressure or physical irritation from the tube can lead to: Post-extubation sore throat: A common and uncomfortable complaint. Post-extubation dysphonia: Hoarseness or voice changes resulting from vocal cord irritation. By ensuring more stable and optimal cuff pressure, the continuous controller may mitigate these issues. We will track these outcomes using standardized, validated scales (a Numeric Rating Scale for pain and the GRBAS scale for voice quality) to determine if the intervention leads to a tangible improvement in the patient's immediate recovery experience.
  5. Methodological Rigor

To ensure the results are reliable and unbiased, the study employs key methodological safeguards:

Randomization: Patients are randomly assigned to a study group using a computer-generated sequence to ensure groups are comparable.

Partial Blinding: While the clinical team at the bedside cannot be blinded to the monitoring device, the laboratory analysis of the tracheal secretion samples is performed by personnel who are completely unaware of which group the sample came from. This prevents bias in determining the primary outcome.

In summary, this study seeks to provide high-quality evidence to guide clinical practice in operating rooms, determining if an investment in automated pressure control technology yields measurable benefits in patient safety and comfort when using state-of-the-art endotracheal tubes.

Being tested
Application of oropharyngeal dye and tracheal aspirate collection

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Application of oropharyngeal dye and tracheal aspirate collectionDevice

    After intubation, 2 mL of blue dye will be applied to the oropharyngeal mucosa. Once hemodynamically stable (MAP >65 mmHg), the first tracheal aspirate will be collected within 10 minutes by a blinded investigator for analysis.

Study groups in NCT07017205
Study groupRoleWhat they receive
Conventional Cuff Pressure Control GroupActive comparatorPatients will be intubated by experienced anesthesiologists using a TaperGuard Evac tube (Covidien) with tapered cuff and subglottic suction system. Cuff inflation will be performed using the standard method commonly employed in clinical practice (passive recoil of syringe plunger).
Receives: Device: Application of oropharyngeal dye and tracheal aspirate collection
Continuous Cuff Pressure Control GroupExperimentalThe intervention group will receive a TaperGuard Evac tube (Covidien) with tapered cuff and subglottic suction system, plus continuous cuff pressure monitoring using the Pressure Easy® device (Medtronic) to maintain 25-30 cmH₂O.
Receives: Device: Application of oropharyngeal dye and tracheal aspirate collection

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Penetration of blue-dyed oropharyngeal secretions into the distal airway

    Evaluate the penetration of blue-dyed oropharyngeal secretions into the distal airway in patients undergoing orotracheal intubation.

    Measured: From enrollment to the end of Surgery: Tracheal aspirate samples will be collected at two defined time points: the first between 10 and 30 minutes after intubation and hemodynamic stabilization, and the second immediately prior to extubation.

Secondary outcomes (3)
  1. Real-time changes in endotracheal tube cuff pressure during the surgical procedure

    Cuff pressure monitoring will be performed at predefined intervals. In the experimental group, continuous cuff pressure monitoring will be conducted using the Pressure Easy® Cuff Pressure Controller. In the control group, cuff pressure will be manually regulated with a manovacuometer, using the syringe-backflow method to adjust pressure.

    Measured: Intraoperative ( surgical procedure)

  2. Determine the incidence of post-extubation pain.

    Post extubation pain evaluated using the verbal numerical rating scale (0-10).

    Measured: The pain will be assessed at the following post-extubation time points: 1 hour, 2 hours, 3 hours, and 24 hours.

  3. Determine the incidence of post-extubation dysphonia.

    Post-extubation dysphonia: Assessed using the GRBAS (Grade, Roughness, Breathiness, Asthenia, Strain) clinical scale, with the grade aspect scored from 0 to 3.

    Measured: These dysphonia will be assessed at the following post-extubation time points: 1 hour, 2 hours, 3 hours, and 24 hours.

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted12 Jun 2025
  2. Study start1 Feb 2026 (estimated)
  3. Primary completion30 Apr 2026 (estimated)
  4. Study completion31 May 2026 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Screening
Allocation
Randomised
Intervention model
Parallel groups
Masking
Double blind
Who is masked
Participant, Investigator
Enrolment
72 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07017205
Sponsor's protocol ID
PRIISABA15678
Status last verified
Dec 2025
First submitted
4 Jun 2025
Last updated
15 Dec 2025
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Undecided

Publications

  • Dullenkopf A, Gerber A, Weiss M. Fluid leakage past tracheal tube cuffs: evaluation of the new Microcuff endotracheal tube. Intensive Care Med. 2003 Oct;29(10):1849-53. doi: 10.1007/s00134-003-1933-6. Epub 2003 Aug 16.

    PubMed 12923620
  • Lorente L, Lecuona M, Jimenez A, Lorenzo L, Roca I, Cabrera J, Llanos C, Mora ML. Continuous endotracheal tube cuff pressure control system protects against ventilator-associated pneumonia. Crit Care. 2014 Apr 21;18(2):R77. doi: 10.1186/cc13837.

    PubMed 24751286
  • Blot SI, Poelaert J, Kollef M. How to avoid microaspiration? A key element for the prevention of ventilator-associated pneumonia in intubated ICU patients. BMC Infect Dis. 2014 Nov 28;14:119. doi: 10.1186/1471-2334-14-119.

    PubMed 25430629

Questions about this trial

What is this clinical trial studying?

A study testing Application of oropharyngeal dye and tracheal aspirate collection in people with Endotracheal Tube Cuff and Microaspiration, run by Argentinian Intensive Care Society at 1 site in Argentina.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 7 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: opening soon, as of the sponsor's last update on 15 Dec 2025. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Argentina. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

Contact Gustavo A Plotnikow, BPT; BCs ICU; PhD(c) (+5491164543771, gplotnikow@hbritanico.com.ar), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Penetration of blue-dyed oropharyngeal secretions into the distal airway (time frame: From enrollment to the end of Surgery: Tracheal aspirate samples will be collected at two defined time points: the first between 10 and 30 minutes after intubation and hemodynamic stabilization, and the second immediately prior to extubation.). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT07017205, which also lists 3 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 15 Dec 2025.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in