Endotracheal Tube CuffNCT07017205
Microaspiration and Endotracheal Tubes
A study testing Application of oropharyngeal dye and tracheal aspirate collection in people with Endotracheal Tube Cuff and Microaspiration, run by Argentinian Intensive Care Society at 1 site in Argentina.
Trial summary
The goal of this clinical trial is to learn if a new method for managing breathing tube pressure is better at preventing fluid from leaking into patients' lungs during surgery. It will also check if it causes fewer side effects like a sore throat. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Endotracheal Tube Cuff, Microaspiration, Endotracheal Tube Cuff Pressure
- What is being tested?
- Application of oropharyngeal dye and tracheal aspirate collection
- Type of treatment
- Injection or infusion, Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 72 participants
- Where
- 1 siteArgentina
- Study dates
- 1 Feb 2026to 31 May 2026
- Phase
- Interventional
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Adult patients (>18 years old) scheduled for surgery lasting at least one hour.
- ASA I-III classification.
- Signed informed consent.
Who cannot join
- Pre-existing airway pathology (e.g., tracheomalacia, granulomas, stenosis, tumors).
- Anticipated difficult intubation (Macocha Score > 3 points).
- Selective lung ventilation / one-lung ventilation.
- Current participation in another clinical trial.
- Elimination Criteria:
- Accidental extubation.
- Cardiorespiratory arrest or death.
Trial locations and contacts
1 site in 1 country. Contact the study team or a site near you to ask about taking part.
Argentina1 site
Hospital Britanico de Buenos Aires
CABA, Buenos Aires, 1280
Gustavo A Plotnikow, +5491164543771, gplotnikow@hbritanico.com.ar
About this study
Official title: Automated Versus Manual Cuff Pressure Control for Preventing Microaspiration With TaperGuard Endotracheal Tubes in Elective Surgery: A Randomized Controlled Trial
The goal of this clinical trial is to learn if a new method for managing breathing tube pressure is better at preventing fluid from leaking into patients' lungs during surgery. It will also check if it causes fewer side effects like a sore throat.
The main questions it aims to answer are:
Read more
Does using a continuous pressure controller reduce fluid leakage past the breathing tube cuff compared to the standard manual method? Does the continuous pressure controller lead to fewer and less severe sore throats and voice changes after surgery?
Researchers will compare two groups:
Group 1: Patients whose breathing tube cuff pressure is managed with a continuous automatic controller.
Group 2: Patients whose breathing tube cuff pressure is managed with the standard manual method.
Participants will:
Be randomly assigned to one of the two groups before their surgery. Receive a small, safe amount of blue dye in their mouth during the procedure to help measure leakage.
Have two small secretion samples collected from their breathing tube during surgery.
Be asked about sore throat and voice changes at 1, 2, 3, and 24 hours after the breathing tube is removed.
Read the detailed description
- The Clinical Challenge: Microaspiration and the Breathing Tube Endotracheal intubation is a life-saving procedure, but it inherently bypasses the body's natural defenses against lung infection. A critical, yet often overlooked, problem is microaspiration. This is the silent leakage of small amounts of oropharyngeal secretions past the cuff of the breathing tube and into the lower airways and lungs. This phenomenon is a primary contributor to the development of Ventilator-Associated Pneumonia (VAP), a serious complication that increases patient morbidity, mortality, and healthcare costs. The cuff's primary role is to create a seal within the trachea. However, conventional cylindrical cuffs can form folds or channels when inflated, creating a direct pathway for secretions to leak through. Furthermore, maintaining the correct cuff pressure (recommended 25-30 cmH₂O) is challenging; pressure can fluctuate due to patient movement, changes in anesthesia gas volume, and surgical positioning.
- Technological Innovations and the Evidence Gap To address these issues, manufacturers have developed advanced endotracheal tubes. This study focuses on the TaperGuard™ Evac tube (Covidien/Medtronic), which features a uniquely shaped tapered cuff. This design is intended to inflate more uniformly against the tracheal wall, theoretically reducing the formation of leakage channels compared to traditional cylindrical cuffs. Concurrently, technology for pressure management has evolved. While the current standard of care involves intermittent manual checks with a manometer, automated cuff pressure controllers (like the Pressure Easy® device) have been introduced. These devices continuously monitor and adjust the pressure, maintaining it within a pre-set target range throughout the entire procedure without manual intervention. While laboratory (bench-top) studies strongly suggest that tapered cuffs are superior at preventing fluid leakage, and some early clinical studies are promising, there is a lack of robust, in-vivo evidence from a controlled surgical setting. This study aims to fill that gap by directly testing the combined effect of the advanced tube design with two different levels of pressure management sophistication.
- The Study's Core Investigation: A Two-Factor Comparison This trial is not just testing a new device, but rather investigating a clinical management strategy. The central question is: Does moving from a manual, intermittent pressure management protocol to a continuous, automated one provide a significant clinical benefit when using a modern, tapered-cuff endotracheal tube? To answer this, we are employing a rigorous model to objectively quantify microaspiration: The Blue Dye Model: A small, safe volume of blue dye is instilled into the patient's oropharynx above the cuff after intubation. The presence or absence of this dye in tracheal aspirate samples, collected later from below the cuff, serves as an objective, binary measure (Yes/No) of whether leakage has occurred.
- Broader Impact and Secondary Patient-Centered Outcomes Beyond the primary goal of preventing pneumonia, the study also investigates patient comfort and safety post-operatively. Damage to the tracheal mucosa from improper cuff pressure or physical irritation from the tube can lead to: Post-extubation sore throat: A common and uncomfortable complaint. Post-extubation dysphonia: Hoarseness or voice changes resulting from vocal cord irritation. By ensuring more stable and optimal cuff pressure, the continuous controller may mitigate these issues. We will track these outcomes using standardized, validated scales (a Numeric Rating Scale for pain and the GRBAS scale for voice quality) to determine if the intervention leads to a tangible improvement in the patient's immediate recovery experience.
- Methodological Rigor
To ensure the results are reliable and unbiased, the study employs key methodological safeguards:
Randomization: Patients are randomly assigned to a study group using a computer-generated sequence to ensure groups are comparable.
Partial Blinding: While the clinical team at the bedside cannot be blinded to the monitoring device, the laboratory analysis of the tracheal secretion samples is performed by personnel who are completely unaware of which group the sample came from. This prevents bias in determining the primary outcome.
In summary, this study seeks to provide high-quality evidence to guide clinical practice in operating rooms, determining if an investment in automated pressure control technology yields measurable benefits in patient safety and comfort when using state-of-the-art endotracheal tubes.
- Being tested
- Application of oropharyngeal dye and tracheal aspirate collection
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Application of oropharyngeal dye and tracheal aspirate collectionDevice
After intubation, 2 mL of blue dye will be applied to the oropharyngeal mucosa. Once hemodynamically stable (MAP >65 mmHg), the first tracheal aspirate will be collected within 10 minutes by a blinded investigator for analysis.
| Study group | Role | What they receive |
|---|---|---|
| Conventional Cuff Pressure Control Group | Active comparator | Patients will be intubated by experienced anesthesiologists using a TaperGuard Evac tube (Covidien) with tapered cuff and subglottic suction system. Cuff inflation will be performed using the standard method commonly employed in clinical practice (passive recoil of syringe plunger). Receives: Device: Application of oropharyngeal dye and tracheal aspirate collection |
| Continuous Cuff Pressure Control Group | Experimental | The intervention group will receive a TaperGuard Evac tube (Covidien) with tapered cuff and subglottic suction system, plus continuous cuff pressure monitoring using the Pressure Easy® device (Medtronic) to maintain 25-30 cmH₂O. Receives: Device: Application of oropharyngeal dye and tracheal aspirate collection |
What is being measured
The primary outcome is the main question the study is designed to answer.
Penetration of blue-dyed oropharyngeal secretions into the distal airway
Evaluate the penetration of blue-dyed oropharyngeal secretions into the distal airway in patients undergoing orotracheal intubation.
Measured: From enrollment to the end of Surgery: Tracheal aspirate samples will be collected at two defined time points: the first between 10 and 30 minutes after intubation and hemodynamic stabilization, and the second immediately prior to extubation.
Secondary outcomes (3)
Real-time changes in endotracheal tube cuff pressure during the surgical procedure
Cuff pressure monitoring will be performed at predefined intervals. In the experimental group, continuous cuff pressure monitoring will be conducted using the Pressure Easy® Cuff Pressure Controller. In the control group, cuff pressure will be manually regulated with a manovacuometer, using the syringe-backflow method to adjust pressure.
Measured: Intraoperative ( surgical procedure)
Determine the incidence of post-extubation pain.
Post extubation pain evaluated using the verbal numerical rating scale (0-10).
Measured: The pain will be assessed at the following post-extubation time points: 1 hour, 2 hours, 3 hours, and 24 hours.
Determine the incidence of post-extubation dysphonia.
Post-extubation dysphonia: Assessed using the GRBAS (Grade, Roughness, Breathiness, Asthenia, Strain) clinical scale, with the grade aspect scored from 0 to 3.
Measured: These dysphonia will be assessed at the following post-extubation time points: 1 hour, 2 hours, 3 hours, and 24 hours.
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted12 Jun 2025
- Study start1 Feb 2026 (estimated)
- Primary completion30 Apr 2026 (estimated)
- Study completion31 May 2026 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (3)Papers the sponsor has linked to this study.
- Other trials for Endotracheal Tube CuffStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Screening
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Double blind
- Who is masked
- Participant, Investigator
- Enrolment
- 72 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Argentinian Intensive Care Society
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Gustavo Plotnikow, HOSPITAL BRITANICO DE BUENOS AIRES
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT07017205
- Sponsor's protocol ID
- PRIISABA15678
- Status last verified
- Dec 2025
- First submitted
- 4 Jun 2025
- Last updated
- 15 Dec 2025
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- Undecided
Publications
Dullenkopf A, Gerber A, Weiss M. Fluid leakage past tracheal tube cuffs: evaluation of the new Microcuff endotracheal tube. Intensive Care Med. 2003 Oct;29(10):1849-53. doi: 10.1007/s00134-003-1933-6. Epub 2003 Aug 16.
PubMed 12923620Lorente L, Lecuona M, Jimenez A, Lorenzo L, Roca I, Cabrera J, Llanos C, Mora ML. Continuous endotracheal tube cuff pressure control system protects against ventilator-associated pneumonia. Crit Care. 2014 Apr 21;18(2):R77. doi: 10.1186/cc13837.
PubMed 24751286Blot SI, Poelaert J, Kollef M. How to avoid microaspiration? A key element for the prevention of ventilator-associated pneumonia in intubated ICU patients. BMC Infect Dis. 2014 Nov 28;14:119. doi: 10.1186/1471-2334-14-119.
PubMed 25430629
Study at a glance
From the registry record, last updated by the sponsor on 15 Dec 2025. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Automated Versus Manual Cuff Pressure Control for Preventing Microaspiration With TaperGuard Endotracheal Tubes in Elective Surgery: A Randomized Controlled Trial
- ClinicalTrials.gov ID
- NCT07017205
- Acronym / sponsor ID
- PRIISABA15678
- Study type
- Interventional
- Recruitment status
- Not yet recruiting
- Enrolment
- 72 participants (estimated)
- Lead sponsor
- Argentinian Intensive Care SocietyUniversity, hospital or other
- Study start
- 1 Feb 2026 (estimated)
- Primary completion
- 30 Apr 2026 (estimated)
- Study completion
- 31 May 2026 (estimated)
- First posted
- 12 Jun 2025 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The goal of this clinical trial is to learn if a new method for managing breathing tube pressure is better at preventing fluid from leaking into patients' lungs during surgery. It will also check if it causes fewer side effects like a sore throat.
The main questions it aims to answer are:
Does using a continuous pressure controller reduce fluid leakage past the breathing tube cuff compared to the standard manual method? Does the continuous pressure controller lead to fewer and less severe sore throats and voice changes after surgery?
Researchers will compare two groups:
Group 1: Patients whose breathing tube cuff pressure is managed with a continuous automatic controller.
Group 2: Patients whose breathing tube cuff pressure is managed with the standard manual method.
Participants will:
Be randomly assigned to one of the two groups before their surgery. Receive a small, safe amount of blue dye in their mouth during the procedure to help measure leakage.
Have two small secretion samples collected from their breathing tube during surgery.
Be asked about sore throat and voice changes at 1, 2, 3, and 24 hours after the breathing tube is removed.
Detailed description
- The Clinical Challenge: Microaspiration and the Breathing Tube Endotracheal intubation is a life-saving procedure, but it inherently bypasses the body's natural defenses against lung infection. A critical, yet often overlooked, problem is microaspiration. This is the silent leakage of small amounts of oropharyngeal secretions past the cuff of the breathing tube and into the lower airways and lungs. This phenomenon is a primary contributor to the development of Ventilator-Associated Pneumonia (VAP), a serious complication that increases patient morbidity, mortality, and healthcare costs. The cuff's primary role is to create a seal within the trachea. However, conventional cylindrical cuffs can form folds or channels when inflated, creating a direct pathway for secretions to leak through. Furthermore, maintaining the correct cuff pressure (recommended 25-30 cmH₂O) is challenging; pressure can fluctuate due to patient movement, changes in anesthesia gas volume, and surgical positioning.
- Technological Innovations and the Evidence Gap To address these issues, manufacturers have developed advanced endotracheal tubes. This study focuses on the TaperGuard™ Evac tube (Covidien/Medtronic), which features a uniquely shaped tapered cuff. This design is intended to inflate more uniformly against the tracheal wall, theoretically reducing the formation of leakage channels compared to traditional cylindrical cuffs. Concurrently, technology for pressure management has evolved. While the current standard of care involves intermittent manual checks with a manometer, automated cuff pressure controllers (like the Pressure Easy® device) have been introduced. These devices continuously monitor and adjust the pressure, maintaining it within a pre-set target range throughout the entire procedure without manual intervention. While laboratory (bench-top) studies strongly suggest that tapered cuffs are superior at preventing fluid leakage, and some early clinical studies are promising, there is a lack of robust, in-vivo evidence from a controlled surgical setting. This study aims to fill that gap by directly testing the combined effect of the advanced tube design with two different levels of pressure management sophistication.
- The Study's Core Investigation: A Two-Factor Comparison This trial is not just testing a new device, but rather investigating a clinical management strategy. The central question is: Does moving from a manual, intermittent pressure management protocol to a continuous, automated one provide a significant clinical benefit when using a modern, tapered-cuff endotracheal tube? To answer this, we are employing a rigorous model to objectively quantify microaspiration: The Blue Dye Model: A small, safe volume of blue dye is instilled into the patient's oropharynx above the cuff after intubation. The presence or absence of this dye in tracheal aspirate samples, collected later from below the cuff, serves as an objective, binary measure (Yes/No) of whether leakage has occurred.
- Broader Impact and Secondary Patient-Centered Outcomes Beyond the primary goal of preventing pneumonia, the study also investigates patient comfort and safety post-operatively. Damage to the tracheal mucosa from improper cuff pressure or physical irritation from the tube can lead to: Post-extubation sore throat: A common and uncomfortable complaint. Post-extubation dysphonia: Hoarseness or voice changes resulting from vocal cord irritation. By ensuring more stable and optimal cuff pressure, the continuous controller may mitigate these issues. We will track these outcomes using standardized, validated scales (a Numeric Rating Scale for pain and the GRBAS scale for voice quality) to determine if the intervention leads to a tangible improvement in the patient's immediate recovery experience.
- Methodological Rigor
To ensure the results are reliable and unbiased, the study employs key methodological safeguards:
Randomization: Patients are randomly assigned to a study group using a computer-generated sequence to ensure groups are comparable.
Partial Blinding: While the clinical team at the bedside cannot be blinded to the monitoring device, the laboratory analysis of the tracheal secretion samples is performed by personnel who are completely unaware of which group the sample came from. This prevents bias in determining the primary outcome.
In summary, this study seeks to provide high-quality evidence to guide clinical practice in operating rooms, determining if an investment in automated pressure control technology yields measurable benefits in patient safety and comfort when using state-of-the-art endotracheal tubes.
Study design
- Primary purpose
- Screening
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Double blind (participant, investigator)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| Conventional Cuff Pressure Control Group | Active comparator | Device: Application of oropharyngeal dye and tracheal aspirate collectionPatients will be intubated by experienced anesthesiologists using a TaperGuard Evac tube (Covidien) with tapered cuff and subglottic suction system. Cuff inflation will be performed using the standard method commonly employed in clinical practice (passive recoil of syringe plunger). |
| Continuous Cuff Pressure Control Group | Experimental | Device: Application of oropharyngeal dye and tracheal aspirate collectionThe intervention group will receive a TaperGuard Evac tube (Covidien) with tapered cuff and subglottic suction system, plus continuous cuff pressure monitoring using the Pressure Easy® device (Medtronic) to maintain 25-30 cmH₂O. |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (3 listed)
- Adult patients (>18 years old) scheduled for surgery lasting at least one hour.
- ASA I-III classification.
- Signed informed consent.
Key exclusion criteria (7 listed)
- Pre-existing airway pathology (e.g., tracheomalacia, granulomas, stenosis, tumors).
- Anticipated difficult intubation (Macocha Score > 3 points).
- Selective lung ventilation / one-lung ventilation.
- Current participation in another clinical trial.
- Accidental extubation.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Application of oropharyngeal dye and tracheal aspirate collectionAfter intubation, 2 mL of blue dye will be applied to the oropharyngeal mucosa. Once hemodynamically stable (MAP >65 mmHg), the first tracheal aspirate will be collected within 10 minutes by a blinded investigator for analysis. | Device | Continuous Cuff Pressure Control Group, Conventional Cuff Pressure Control Group |
Primary outcome
Penetration of blue-dyed oropharyngeal secretions into the distal airway
Time frame: From enrollment to the end of Surgery: Tracheal aspirate samples will be collected at two defined time points: the first between 10 and 30 minutes after intubation and hemodynamic stabilization, and the second immediately prior to extubation.
Evaluate the penetration of blue-dyed oropharyngeal secretions into the distal airway in patients undergoing orotracheal intubation.
3 secondary outcomes
Real-time changes in endotracheal tube cuff pressure during the surgical procedure
Time frame: Intraoperative ( surgical procedure)
Determine the incidence of post-extubation pain.
Time frame: The pain will be assessed at the following post-extubation time points: 1 hour, 2 hours, 3 hours, and 24 hours.
Determine the incidence of post-extubation dysphonia.
Time frame: These dysphonia will be assessed at the following post-extubation time points: 1 hour, 2 hours, 3 hours, and 24 hours.
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 15 Dec 2025.
- Background: PubMed 12923620Dullenkopf A, Gerber A, Weiss M. Fluid leakage past tracheal tube cuffs: evaluation of the new Microcuff endotracheal tube. Intensive Care Med. 2003 Oct;29(10):1849-53. doi: 10.1007/s00134-003-1933-6. Epub 2003 Aug 16.
- Background: PubMed 24751286Lorente L, Lecuona M, Jimenez A, Lorenzo L, Roca I, Cabrera J, Llanos C, Mora ML. Continuous endotracheal tube cuff pressure control system protects against ventilator-associated pneumonia. Crit Care. 2014 Apr 21;18(2):R77. doi: 10.1186/cc13837.
- Background: PubMed 25430629Blot SI, Poelaert J, Kollef M. How to avoid microaspiration? A key element for the prevention of ventilator-associated pneumonia in intubated ICU patients. BMC Infect Dis. 2014 Nov 28;14:119. doi: 10.1186/1471-2334-14-119.
- Individual participant dataSharing planned: Undecided
Related trials for Endotracheal Tube Cuff
Not yet recruiting
Effect of a Brief Educational Intervention on Endotracheal Tube Cuff Pressure
Intubation, Endotracheal Tube Cuff Pressure
Not yet recruitingObservational study
Irrigation Fluid Volume, Tube Cuff Pressure, and Neck Swelling During Shoulder Arthroscopy
Shoulder Arthroscopy, Endotracheal Tube Cuff Pressure
Not yet recruitingObservational study
Effect of Loss-of-Resistance Syringe Training on Endotracheal Tube Cuff Pressure
Endotracheal Tube Cuff Pressure, Postoperative Sore Throat
Recruiting
Effect of Endotracheal Tube Cuff Pressure Management on Postoperative Sore Throat in Pediatric Laparoscopic Appendectomy
Appendicitis Acute, Postoperative Sore Throat, Cough, Hoarseness
Not yet recruiting
Effect of Cuff Pressure Assessment Methods on Postoperative Complications in Breast Surgery
Airway Complications, Postoperative Sore Throat
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Application of oropharyngeal dye and tracheal aspirate collection in people with Endotracheal Tube Cuff and Microaspiration, run by Argentinian Intensive Care Society at 1 site in Argentina.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 3 inclusion and 7 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: opening soon, as of the sponsor's last update on 15 Dec 2025. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Argentina. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
Contact Gustavo A Plotnikow, BPT; BCs ICU; PhD(c) (+5491164543771, gplotnikow@hbritanico.com.ar), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Penetration of blue-dyed oropharyngeal secretions into the distal airway (time frame: From enrollment to the end of Surgery: Tracheal aspirate samples will be collected at two defined time points: the first between 10 and 30 minutes after intubation and hemodynamic stabilization, and the second immediately prior to extubation.). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT07017205, which also lists 3 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?