AzTrials
AzTrials

Thoracoabdominal Aortic AneurysmNCT06103942

Automated Carbon Dioxide Angiography in Fenestrated/Branched Endovascular Abdominal Aortic Aneurysm Repair

An observational study of Thoracoabdominal Aortic Aneurysm, run by Uppsala University.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

Carbon Dioxide (CO2)-based angiography is a digital subtraction angiography (DSA), where CO2 is used as an intra-arterial contrast agent. Now, with the availability of an automated CO2 injector system (Angiodroid Srl, Italy) and the improvement in image acquisition protocols, CO2 angiography is increasingly used for… Read more about this study

Who is it for?
Ages 18 to 95 years
Conditions the study is for
Thoracoabdominal Aortic Aneurysm
What is being tested?
CO2 angiography
How many people
30 participants
Where
No sites listed yet
Study dates
1 Nov 2023to 1 Nov 2025
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 95 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Study population: Patient with a formal indication to an endovascular treatment of complex throacoabdominal aneurysms.

Who may be able to join

  • Patients with indication for treatment of complex TAAA according to accepted international guidelines
  • Provided informed consent

Who cannot join

  • Severe COPD (Chronic Obstructive Pulmonary Disease), GOLD Stage 3 and 4
  • Known atrium- or ventricular septal defect with right-left-shunt
  • Current participation in other interventional studies

Trial locations and contacts

No sites are listed yet.

Giuseppe Asciutto, MD, PhD contact

+46 727 045645

giuseppe.asciutto@uu.se

About this study

Official title: Automated Carbon Dioxide Angiography in Comparison to Iodinated Contrast Medium Angiography During Fenestrated/Branched Endovascular Abdominal Aortic Aneurysm Repair (F/B-EVAR)

Carbon Dioxide (CO2)-based angiography is a digital subtraction angiography (DSA), where CO2 is used as an intra-arterial contrast agent.

Now, with the availability of an automated CO2 injector system (Angiodroid Srl, Italy) and the improvement in image acquisition protocols, CO2 angiography is increasingly used for vascular imaging and endovascular procedures.

Read more

Fenestrated and branched endovascular aortic repair (F/B-EVAR) for thoracoabdominal aortic aneurysms (TAAAs) is nowadays considered the treatment of first choice, due to its reduced procedure-related morbidity and mortality, when compared to open repair.

A peculiarity of these procedures is the need of high volumes of contrast media, which are not needed in case of open repair. This increases the related risk of impaired kidney function at the short- and long-term.

The present study will specifically examine the safety of the use of CO2 as intra-arterial contrast agent using the Angiodroid automated CO2-injection system during F/B-EVAR procedures. Furthermore, the current study will focus on image quality during the different steps of the procedure with the aim of standardize injection parameters (volume and pressure) for the detection of the ostium of the visceral vessels as well as of the iliac arteries, all defined as target vessels.

Read the detailed description

Carbon Dioxide (CO2)-based angiography is a digital subtraction angiography (DSA), where CO2 is used as an intra-arterial contrast agent. This practice started in 1970s and it is commonly used for patients who have an impaired renal function, allergy to iodinated contrast media (ICM) or that could have a contrast-induced nephropathy (CIN) risk.

Carbon dioxide is an effective and low-risk alternative to ICM, which is nowadays used in endovascular procedures, thanks to its unique properties, such as no risk for nephrotoxicity or allergic reaction. For many years, the two most important restrictions for this technique consisted of: 1) the absence of a delivery system that could minimize the risk of air contamination during the CO2 angiography and allow controlled injection (in terms of pressure and volume of injection) of the CO2 and 2) the absence of a customized imaging protocol for a better visualization of CO2 during DSA acquisition.

Now, with the availability of an automated CO2 injector system (Angiodroid Srl, Italy) and the improvement in image acquisition protocols, CO2 angiography is increasingly used for vascular imaging and endovascular procedures.

Fenestrated and branched endovascular aortic repair (F/B-EVAR) for thoracoabdominal aortic aneurysms (TAAAs) is nowadays considered the treatment of first choice, due to its reduced procedure-related morbidity and mortality, when compared to open repair.

A peculiarity of these procedures is the need of high volumes of contrast media, which are not needed in case of open repair. This increases the related risk of impaired kidney function at the short- and long-term.

The literature on CO2 angiography still lacks on studies regarding the systematic use of the technique in F/B-EVAR procedures.

The present study will specifically examine the safety of the use of CO2 as intra-arterial contrast agent using the Angiodroid automated CO2-injection system during F/B-EVAR procedures. Furthermore, the current study will focus on image quality during the different steps of the procedure with the aim of standardize injection parameters (volume and pressure) for the detection of the ostium of the visceral vessels as well as of the iliac arteries, all defined as target vessels.

The main study hypothesis is that the automated standardized injection of CO2 could provide the same angiographic information and image quality as ICM, which is nowadays used as standard contrast agent in endovascular procedures.

Being tested
CO2 angiography
Keywords
FEVAR, BEVAR, CO2, complex aortic aneurysm
Medical subject headings
Aortic Aneurysm, Thoracoabdominal

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • CO2 angiographyDiagnostic test

    A supplemental CO2 angiography will be performed before and after the stent graft placement.

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Technical success

    Technical success in terms of detecting the ostium of the visceral vessels as well as of the hypogastric arteries (defined as 100% accuracy when compared to the iodinated contrast agent angiography)

    Measured: at the time the intervention

  2. CO2 sensitivity and specificity compared to iodinated contrast agent angiography

    CO2 sensitivity and specificity compared to iodinated contrast agent angiography in detecting dissections, stenosis, occlusions or bleeding of the target vessel. The comparison will be blinded and retrospective.

    Measured: at the time the intervention

Secondary outcomes (1)
  1. Image quality

    Image quality with regard to the CO2 angiography defined as poor, moderate and good. The analysis of the images will be retrospective.

    Measured: at the time the intervention

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted27 Oct 2023
  2. Study start1 Nov 2023 (estimated)
  3. Primary completion1 Nov 2024 (estimated)
  4. Study completion1 Nov 2025 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Cohort
Time perspective
Prospective
Enrolment
30 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06103942
Sponsor's protocol ID
Nov2023
Status last verified
Oct 2023
First submitted
18 Oct 2023
Last updated
27 Oct 2023
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Rolland Y, Duvauferrier R, Lucas A, Gourlay C, Morcet N, Rambeau M, Chaperon J. Lower limb angiography: a prospective study comparing carbon dioxide with iodinated contrast material in 30 patients. AJR Am J Roentgenol. 1998 Aug;171(2):333-7. doi: 10.2214/ajr.171.2.9694446.

    PubMed 9694446
  • Palena LM, Diaz-Sandoval LJ, Candeo A, Brigato C, Sultato E, Manzi M. Automated Carbon Dioxide Angiography for the Evaluation and Endovascular Treatment of Diabetic Patients With Critical Limb Ischemia. J Endovasc Ther. 2016 Feb;23(1):40-8. doi: 10.1177/1526602815616924. Epub 2015 Nov 13.

    PubMed 26567126
  • Scalise F, Novelli E, Auguadro C, Casali V, Manfredi M, Zannoli R. Automated carbon dioxide digital angiography for lower-limb arterial disease evaluation: safety assessment and comparison with standard iodinated contrast media angiography. J Invasive Cardiol. 2015 Jan;27(1):20-6.

    PubMed 25589696
  • Seeger JM, Self S, Harward TR, Flynn TC, Hawkins IF Jr. Carbon dioxide gas as an arterial contrast agent. Ann Surg. 1993 Jun;217(6):688-97; discussion 697-8. doi: 10.1097/00000658-199306000-00011.

    PubMed 8507115
  • Caridi JG, Hawkins IF Jr. CO2 digital subtraction angiography: potential complications and their prevention. J Vasc Interv Radiol. 1997 May-Jun;8(3):383-91. doi: 10.1016/s1051-0443(97)70577-3. No abstract available.

    PubMed 9152911
  • Bettmann MA, D'Agostino R, Juravsky LI, Jeffery RF, Tottle A, Goudey CP. Carbon dioxide as an angiographic contrast agent. A prospective randomized trial. Invest Radiol. 1994 Jun;29 Suppl 2:S45-6. doi: 10.1097/00004424-199406001-00016. No abstract available.

    PubMed 7928269
  • Hawkins IF Jr, Wilcox CS, Kerns SR, Sabatelli FW. CO2 digital angiography: a safer contrast agent for renal vascular imaging? Am J Kidney Dis. 1994 Oct;24(4):685-94. doi: 10.1016/s0272-6386(12)80232-0.

    PubMed 7942829
  • D'Oria M, Wanhainen A, Lindstrom D, Tegler G, Mani K. Editor's Choice - Pre-Operative Moderate to Severe Chronic Kidney Disease is Associated with Worse Short-Term and Mid-Term Outcomes in Patients Undergoing Fenestrated-Branched Endovascular Aortic Repair. Eur J Vasc Endovasc Surg. 2021 Dec;62(6):859-868. doi: 10.1016/j.ejvs.2021.08.033. Epub 2021 Oct 27.

    PubMed 34716095
  • Gallitto E, Faggioli G, Vacirca A, Pini R, Mascoli C, Fenelli C, Logiacco A, Abualhin M, Gargiulo M. The benefit of combined carbon dioxide automated angiography and fusion imaging in preserving perioperative renal function in fenestrated endografting. J Vasc Surg. 2020 Dec;72(6):1906-1916. doi: 10.1016/j.jvs.2020.02.051. Epub 2020 Apr 8.

    PubMed 32276017
  • Chisci E, Michelagnoli S, Masciello F, Turini F, Panci S, Troisi N. Benefits and Role of Carbon Dioxide Angiography in Case of Misalignment Between Fenestration and Target Vessel During Fenestrated Endovascular Aneurysm Repair. J Endovasc Ther. 2022 Feb;29(1):7-10. doi: 10.1177/15266028211032955. Epub 2021 Aug 8.

    PubMed 34369173
  • Geisbusch S, Kuehnl A, Salvermoser M, Reutersberg B, Trenner M, Eckstein HH. Editor's Choice - Hospital Incidence, Treatment, and In Hospital Mortality Following Open and Endovascular Surgery for Thoraco-abdominal Aortic Aneurysms in Germany from 2005 to 2014: Secondary Data Analysis of the Nationwide German DRG Microdata. Eur J Vasc Endovasc Surg. 2019 Apr;57(4):488-498. doi: 10.1016/j.ejvs.2018.10.030. Epub 2019 Feb 7.

    PubMed 30745030
  • de Lachomette MF, Della N, Maucort-Boulch D, Duprey A, Rosset E, Feugier P, Lermusiaux P, Albertini JN, Millon A. Renal Function after Fenestrated or Branched Endovascular Aortic Repair: The Early Impairment Predictive Factors. Ann Vasc Surg. 2017 Apr;40:1-9. doi: 10.1016/j.avsg.2016.06.014. Epub 2016 Aug 27.

    PubMed 27575304

Questions about this trial

What is this clinical trial studying?

An observational study of Thoracoabdominal Aortic Aneurysm, run by Uppsala University.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 27 Oct 2023. Status can change between updates, so confirm with the study contact before making plans.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Giuseppe Asciutto, MD, PhD (+46 727 045645, giuseppe.asciutto@uu.se), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Technical success (time frame: at the time the intervention). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT06103942, which also lists 12 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 27 Oct 2023.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in