This is a prospective, single-center study. The primary purpose of this study is to evaluate the sensitivity and specificity of offline computational ultrasonic flow ratio (UFR) with conventional pressure wire-based fractional flow reserve (FFR) as the standard reference. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Coronary Artery Stenosis
What is being tested?
fractional flow reserve (FFR); ultrasonic flow ratio (UFR); intravascular ultrasound (IVUS)
How many people
408 participants
Where
No sites listed yet
Study dates
20 Sep 2023to 31 Dec 2024
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Study population: Patients ≥ 18 years of age who will be admitted for coronary angiography and had an indication for FFR measurement at the FuWai Hospital, Beijing, China, due to stable angina or unstable angina will be consecutively enrolled.

Who may be able to join

  • Stable angina pectoris, unstable angina pectoris, or after the acute phase of myocardial infarction
  • Age ≥18 years
  • Written informed consent
  • Intermediated coronary lesions (diameter stenosis of 30%-80% by visual estimation from coronary angiography)

Who cannot join

  • Ineligible for diagnostic IVUS or FFR examination
  • Prior coronary artery bypass grafting of the interrogated vessels
  • Myocardial infarction within 72 h of coronary angiography
  • Severe heart failure
  • Serum creatinine levels >150 umol/L, or glomerular filtration rates <45 ml/kg/1.73 m2
  • Allergy to the contrast agent or adenosine
Show all 9Show fewer
  • Life expectancy < 2 years
  • IVUS pullback not covering the entire lesion
  • Severe myocardial bridge in the interrogated vessel

Trial locations and contacts

No sites are listed yet.

Jie Qian, MD contact

+8613601396650

qianjfw@163.com

About this study

Official title: Functional Diagnostic Accuracy of Ultrasonic Flow Ratio in Assessment of De Novo Coronary Artery Lesions

This is a prospective, single-center study. The primary purpose of this study is to evaluate the sensitivity and specificity of offline computational ultrasonic flow ratio (UFR) with conventional pressure wire-based fractional flow reserve (FFR) as the standard reference. The study will be conducted in Fuwai Hospital, and a total of 408 patients with coronary vessel diameter stenosis ≥30% and ≤80% are planned to be recruited. Participants who meet the inclusion criteria and do not meet the exclusion criteria will undergo intravascular ultrasound (IVUS) followed by FFR examination. IVUS imaging will be sent to an independent core laboratory for UFR calculation. UFR analyses were performed offline in a blinded fashion without awareness of FFR measurement. Using FFR≤0.80 as the gold standard, the sensitivity and specificity of UFR in the functional significance of coronary artery stenosis will be analyzed.

Being tested
fractional flow reserve (FFR); ultrasonic flow ratio (UFR); intravascular ultrasound (IVUS)
Keywords
intravascular ultrasound, ultrasonic flow ratio, fractional flow reserve
Medical subject headings
Coronary Stenosis

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • fractional flow reserve (FFR); ultrasonic flow ratio (UFR); intravascular ultrasound (IVUS)Diagnostic test

    pressure wire-based fractional flow reserve (FFR); intravascular ultrasound (IVUS)-based ultrasonic flow ratio (UFR)

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Sensitivity and specificity of UFR in predicting functionally significant coronary stenosis at the patient level, using FFR as the reference standard

    Sensitivity is defined as the proportion of UFR ≤ 0.80 in patients with hemodynamically-significant stenosis as measured by FFR (FFR ≤ 0.80); specificity is defined as the proportion of UFR > 0.80 in patients without hemodynamically-significant stenosis as measured by FFR (FFR > 0.80).

    Measured: Immediately after the procedure

Secondary outcomes (3)
  1. Sensitivity and specificity of UFR in predicting functionally significant coronary stenosis at the vessel level, using FFR as the reference standard

    Sensitivity is defined as the proportion of UFR ≤ 0.80 in vessels with hemodynamically-significant stenosis as measured by FFR (FFR ≤ 0.80); specificity is defined as the proportion of UFR > 0.80 in vessels without hemodynamically-significant stenosis as measured by FFR (FFR > 0.8).

    Measured: Immediately after the procedure

  2. Diagnostic accuracy of UFR in predicting functionally significant coronary stenosis at the patient level, using FFR as the reference standard

    Diagnostic accuracy is defined as UFFR (≤0.80 or >0.80) to identify hemodynamically-significant coronary stenosis with FFR (≤0.8 or >0.8) as the reference standard.

    Measured: Immediately after the procedure

  3. The AUC of UFR for coronary stenosis with FFR as the gold standard

    AUC is defined as the area under the receiver-operating characteristic curve

    Measured: Immediately after the procedure

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted25 Sep 2023
  2. Study start20 Sep 2023 (estimated)
  3. Primary completion31 Dec 2024 (estimated)
  4. Study completion31 Dec 2024 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Cohort
Time perspective
Prospective
Enrolment
408 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06052670
Sponsor's protocol ID
2023-GSP-GG-4
Acronym
FUNCTION
Status last verified
Sep 2023
First submitted
12 Sep 2023
Last updated
25 Sep 2023
Results posted
No
FDA-regulated drug
No
FDA-regulated device
No

Questions about this trial

What is this clinical trial studying?

An observational study of Coronary Artery Stenosis, run by China National Center for Cardiovascular Diseases.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 9 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 25 Sep 2023. Status can change between updates, so confirm with the study contact before making plans.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Jie Qian, MD (+8613601396650, qianjfw@163.com), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Sensitivity and specificity of UFR in predicting functionally significant coronary stenosis at the patient level, using FFR as the reference standard (time frame: Immediately after the procedure). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 25 Sep 2023.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in