Labor AnalgesiaNCT05909085

The Impact of Needle Manipulation and Accuracy Between Hand Held Automatic and Traditional Ultrasound Device

A study testing Traditional ultrasound and Automated ultrasound in people with Labor Analgesia, run by Yale University at 1 site in United States.

Not yet recruiting

Opening soon. The study is approved but enrolment has not started yet. Sites may already take enquiries.

Sites and contacts
Official record

Search all trials

Trial summary

In this double blinded randomized controlled trial, the investigators would like to compare the effects on needle manipulation when relatively inexperienced sonographist (< 1 year of ultrasound experience) perform ultrasound guided labor epidurals utilizing a traditional handheld ultrasound versus a handheld device… Read more about this study

Who is it for?
Ages 18 to 45 years, women onlyHealthy volunteers can take part
Conditions the study is for
Labor Analgesia
What is being tested?
Traditional ultrasound and Automated ultrasound
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
200 participants
Where
1 siteUnited States
Study dates
1 Jul 2027to Dec 2027
Phase
Interventional

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 45 years
  • Women only
  • Healthy volunteers accepted
  • Adult

Who may be able to join

  • ASA-1, ASA-2, and ASA-3
  • Patients with no known back deformities
  • Ability to sit upright for epidural placement
  • No prior lumbar surgery
  • No allergies to ultrasound gel

Who cannot join

  • Coagulopathy
  • Low platelet count
  • Allergies to local anesthetics

Trial locations and contacts

1 site in 1 country. Contact the study team or a site near you to ask about taking part.

Antonio Gonzalez, MD contact

4133869415

Antonio.Gonzalez-fiol@yale.edu

United States1 site
  • Yale University

    New Haven, Connecticut, 06510

Other trials in United States

About this study

Official title: A Randomized Double Blinded Controlled Trial to Investigate the Impact of Needle Manipulation and Accuracy of Between Two Commercially Available Ultrasound Devices

In this double blinded randomized controlled trial, the investigators would like to compare the effects on needle manipulation when relatively inexperienced sonographist (< 1 year of ultrasound experience) perform ultrasound guided labor epidurals utilizing a traditional handheld ultrasound versus a handheld device that was engineered to provide automated guidance. The primary outcome of this study would be number of needle passes.

Read the detailed description

Patient will be approached upon admission to labor and delivery floor (Standard of care). The study will be presented to the patient and if they agree, they will be consented. (Study). Upon epidural patient request patient will be randomized to A-US vs B-US based on the randomization table. Ten envelopes will be available with the randomization choice. (Study). The resident will walk in with both US devices into the room (for patient blinding) and perform scan with the device the randomization table called for. (Study). After performing scan and markings of the patients back, the research fellow or clinical fellow will be called into the room to evaluate the number of needle manipulation and provide surveys related to patient and labor analgesia satisfaction. (Study).

Number of needle insertion attempts: defined as advancement of the needle through the skin in an effort to enter the epidural space; a needle requiring withdrawal from the skin for reinsertion is to be counted as an additional insertion attempt. Time to landmark identification: defined as the time interval between the start of needle puncture site identification and the time to first needle puncture attempt. The start time of needle puncture site identification in both the LT and UST corresponds to when the resident physician first places his/her hand on the patient to palpate the back. In both groups, all materials, supplies, and equipment will be prepared and readily available prior to the start of the procedure.

Conditions
Labor Analgesia
Being tested
Traditional ultrasound, Automated ultrasound

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Traditional ultrasoundDevice

    Labor epidural will be performed after marking patient skin using traditional ultrasound guidance

  • Automated ultrasoundDevice

    Labor epidural will be performed after marking patient skin using an automated ultrasound device

Study groups in NCT05909085
Study groupRoleWhat they receive
Handheld traditional ultrasoundActive comparatorTraditional US will be used to compare number of needle manipulations to the handheld US.
Receives: Device: Traditional ultrasound
Handheld Automated ultrasoundOtherAutomated device provides automatic information pertaining to distance to epidural space distance and interspace location.
Receives: Device: Automated ultrasound

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Number of needle passes

    Number of ventral needle movements without removing needle from skin. A needle pass is defined as any forward advancement or withdraw and forward redirection of the needle without withdraw from the skin.

    Measured: From local anesthetic injection (time 0) till Loss of resistance (in minutes), up to 60 minutes

Secondary outcomes (7)
  1. Number of Needle attempts

    Number of times the needle is advanced in and out of the skin

    Measured: From local anesthetic injection (time 0) till Loss of resistance (in minutes), up to 60 minutes

  2. Time to obtain ultrasound images with traditional ultrasound device

    Time from placing ultrasound on patients back until markings are complete

    Measured: Time at which ultrasound device is placed on patients back (time 0) until image obtained (in minutes), up to 30 minutes

  3. Time to obtain images with automated ultrasound device

    Time from placing ultrasound on patients back until markings are complete

    Measured: Time at which ultrasound device is placed on patients back (time 0) until image obtained (in minutes), up to 30 minutes

  4. Time from local anesthetic injection till time of epidural space identification

    Time will be recorded once local anesthetic is injected and stopped upon obtaining loss of resistance

    Measured: Up to 60 minutes

  5. Accuracy of handheld ultrasound - difference between predicted epidural space distance minus actual needle distance

    Accuracy will equal the difference between the estimated depth calculated by the device - actual needle depth as measured from skin to epidural space in centimeters.

    Measured: Up to 60 minutes

  6. Accuracy of automated ultrasound device - difference between predicted epidural space distance minus actual needle distance

    Accuracy will equal the difference between the estimated depth calculated by the device - actual needle depth as measured from skin to epidural space in centimeters.

    Measured: Up to 60 minutes

  7. Patient satisfaction

    Assessed after the administration of the loading dose. Patient will be asked to rate their pain on a scale 0-10, 0 = not satisfied, 10 = completely satisfied

    Measured: 15 - 20 minutes after epidural placement

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted18 Jun 2023
  2. Study start1 Jul 2027 (estimated)
  3. Primary completionDec 2027 (estimated)
  4. Study completionDec 2027 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Other
Allocation
Randomised
Intervention model
Parallel groups
Masking
Double blind
Who is masked
Participant, Outcomes assessor
Enrolment
200 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05909085
Sponsor's protocol ID
2000034863
Other IDs
No NIH funding 09.05.23
Status last verified
Sep 2026
First submitted
1 Jun 2023
Last updated
23 Sep 2026
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
No

Publications

  • Vallejo MC, Phelps AL, Singh S, Orebaugh SL, Sah N. Ultrasound decreases the failed labor epidural rate in resident trainees. Int J Obstet Anesth. 2010 Oct;19(4):373-8. doi: 10.1016/j.ijoa.2010.04.002. Epub 2010 Aug 8.

    PubMed 20696564
  • Carvalho B, Seligman KM, Weiniger CF. The comparative accuracy of a handheld and console ultrasound device for neuraxial depth and landmark assessment. Int J Obstet Anesth. 2019 Aug;39:68-73. doi: 10.1016/j.ijoa.2019.01.004. Epub 2019 Jan 11.

    PubMed 30770208
  • Weiniger CF, Carvalho B, Ronel I, Greenberger C, Aptekman B, Almog O, Kagan G, Shalev S. A randomized trial to investigate needle redirections/re-insertions using a handheld ultrasound device versus traditional palpation for spinal anesthesia in obese women undergoing cesarean delivery. Int J Obstet Anesth. 2022 Feb;49:103229. doi: 10.1016/j.ijoa.2021.103229. Epub 2021 Sep 23.

    PubMed 34670725
  • Seligman KM, Weiniger CF, Carvalho B. The Accuracy of a Handheld Ultrasound Device for Neuraxial Depth and Landmark Assessment: A Prospective Cohort Trial. Anesth Analg. 2018 Jun;126(6):1995-1998. doi: 10.1213/ANE.0000000000002407.

    PubMed 28858898