Cardiac Output, LowNCT05905536

Perioperative Monitoring of Cardiac Surgery Patients With the Vitalstream Physiological Monitor

A study testing Vitalstream in people with Cardiac Output, Low and Stroke Volume, run by Wake Forest University Health Sciences at 1 site in United States.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The purpose of this study is to validate cardiac output and stroke volume derived from Vitalstream against Gold Standard measurements obtained using thermodilution. The Vitalstream device is a continuous noninvasive physiological monitor (Caretaker Medical LLC, Charlottesville, Virginia, further referred to as "CTM")… Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Cardiac Output, Low, Stroke Volume
What is being tested?
Vitalstream
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
58 participants
Where
1 siteUnited States
Study dates
15 Aug 2023to 30 Jul 2024
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Adult post-cardiac surgery needing cardiopulmonary bypass and use of the pulmonary artery catheter (PAC) as standard of care, (s/p coronary artery bypass graft (CABG), valve, heart transplant, major aortic \& other vascular surgery, and a combination of CABG and valve procedures)
  • patients (age > 18) admitted to the Intensive Care Unit (ICU) with a pulmonary artery catheter (continuous or intermittent thermodilution cardiac output) and an arterial catheter for Blood Pressure (BP) monitoring (standard of care)

Who cannot join

  • Patients without an appropriately positioned or functioning (PAC) pulmonary artery catheter admitted to the cardiac surgery ICU after surgery. Patients on left ventricular assist device (LVAD) support

Trial locations and contacts

1 site in 1 country.

United States1 site
  • Atrium Health Wake Forest Baptist

    Winston-Salem, North Carolina, 27157

Other trials in United States

About this study

The purpose of this study is to validate cardiac output and stroke volume derived from Vitalstream against Gold Standard measurements obtained using thermodilution. The Vitalstream device is a continuous noninvasive physiological monitor (Caretaker Medical LLC, Charlottesville, Virginia, further referred to as "CTM") provides heart rate, continuous noninvasive blood pressure (BP), respiratory rate, stroke volume and cardiac output.

Read the detailed description

The device is currently undergoing IEC 60601 Medical Safety Standards testing and has already passed all FDA-required emission and discharge testing. The Vitalstream tracks central aortic BP via pulse analysis, specifically Pulse Decomposition Analysis ("PDA"), of the peripheral pulse at a distal site, typically finger. The device uses a low pressure [30-40 mmHg], pump-inflated, finger cuff that pneumatically couples arterial pulsations via a pressure line to a custom-designed piezo-electric pressure sensor for detection and analysis. Physiological data are communicated wirelessly to a tablet-based user interface via Bluetooth. The Vitalstream monitor is most beneficial as it is non-invasive, is a minimal risk device, and for this protocol will not be utilized to make treatment decisions for the study subject.

Being tested
Vitalstream
Keywords
cardiac output, cardiac surgery, pulmonary artery catheter
Medical subject headings
Cardiac Output, Low

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • VitalstreamDevice

    The device will be placed on the subject and monitoring started in the holding room on the morning of surgery. Monitoring will continue postoperatively until the pulmonary artery catheter (PAC) is removed (Standard of Care) or discharged, or at study team discretion. At Intensive Care Unit (ICU) admittance and again 3 hours later a straight leg raise will be done to monitor for changes in hemodynamics.

Study groups in NCT05905536
Study groupRoleWhat they receive
VitalstreamExperimentalDevice placed on the subject preoperatively in the holding room and continued postoperatively into the Cardiac Intensive Care Unit (ICU).
Receives: Device: Vitalstream

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Cardiac output values

    Cardiac output values correlation of cardiac output between the PA catheter as assessed by the CCO and the VitalStream - the amount of blood pumped by the heart minute - Cardiac output is calculated by multiplying stroke volume with heart rate - Cardiac output in humans is generally 5-6 L/min in an at-rest to more than 35 L/min in elite athletes during exercise. HR is determined by signals from the sinoatrial node, which automatically depolarizes at an intrinsic rate of 60 to 100 times each minute - Low-output symptoms are caused by the inability of the heart to generate enough cardiac output. This leads to reduced blood flow to the brain and other vital organs

    Measured: hour 24

  2. Blood pressure values

    correlation of blood pressure continuously being monitored by the Vitalstream and the subjects indwelling arterial line

    Measured: hour 24

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted15 Jun 2023
  2. Study start15 Aug 2023
  3. Primary completion30 Jul 2024
  4. Study completion30 Jul 2024

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Other
Allocation
Not applicable
Intervention model
Single group
Model description
cardiac patient population through the major part of their continuum of care, with monitoring starting at the start of the subjects holding room pre-operative preparation and continuing through surgery to recovery in the Cardiovascular Intensive Care Unit (CVICU), where monitoring will continue until the pulmonary artery catheter (PAC) is removed
Masking
None (open label)
Enrolment
58 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05905536
Sponsor's protocol ID
IRB00096075
Status last verified
Feb 2025
First submitted
7 Jun 2023
Last updated
12 Aug 2025
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study testing Vitalstream in people with Cardiac Output, Low and Stroke Volume, run by Wake Forest University Health Sciences at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 12 Aug 2025. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Cardiac output values (time frame: hour 24). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 12 Aug 2025.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in