Blood Glucose, HighNCT05504096

Calibration and Evaluation of Non-Invasive Wireless Blood Glucose Monitoring

A study testing Actxa BGM Tracker (GLO2) and SVT In-Ear Prototype (IEP) in people with Blood Glucose, High and Blood Glucose, Low, run by KK Women's and Children's Hospital at 1 site in Singapore.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Wrist-worn wearables are used for fitness and health monitoring. This global expansion of wearable technology opens up opportunities for the diagnosis and management of chronic conditions. Read more about this study

Who is it for?
Ages 21 years and olderHealthy volunteers can take part
Conditions the study is for
Blood Glucose, High, Blood Glucose, Low
What is being tested?
Actxa BGM Tracker (GLO2) and SVT In-Ear Prototype (IEP)
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
500 participants
Where
1 siteSingapore
Study dates
8 Oct 2021to 18 Feb 2023
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 21 years and older
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Who may be able to join

  • Aged 21 years and above
  • Are able to walk to, take public transport to or drive to the testing site independently
  • Able to understand written and spoken English

Who cannot join

  • Have difficulty in giving informed consent
  • Have a pacemaker
  • Are diagnosed with hypertension
  • Are on anti-hypertensive drugs
  • Are pregnant

Trial locations and contacts

1 site in 1 country.

Singapore1 site
  • KK Women's and Children's Hospital

    Singapore, 229899

Other trials in Singapore

About this study

Wrist-worn wearables are used for fitness and health monitoring. This global expansion of wearable technology opens up opportunities for the diagnosis and management of chronic conditions.

Diabetic patients have a two to three-fold higher risk of developing cardiovascular disease and that cardiovascular diseases accounted for 29.2.% of all deaths in Singapore. The wearable device is a promising avenue that allows for continuous monitoring of the large population of patients. Its ubiquitous and easy to use nature is an added advantage for its implementation.

In this study, the investigators aim to leverage existing photoplethysmography (PPG) technology, together with artificial intelligence, to accurately monitor blood glucose levels in a continuous and non-invasive manner. A simple non-invasive tool to monitor blood glucose will be developed, and alerts will be issued when the blood glucose levels fall in the unhealthy range. A standard glucometer will be used to calibrate and validate PPG measurements of blood glucose. This study aims to recruit 500 participants from KK Women's and Children's Hospital.

Read the detailed description

Wrist-worn wearables are currently being used for fitness and health monitoring. The global expansion of wearable technology combined with smartphones access creates new questions and opportunities in the diagnosis and management of chronic conditions.

High-end consumer wearables have integrated green light reflection photoplethysmography (PPG) sensors into their products. A PPG is an optically obtained plethysmogram that can be used to detect blood volume changes within mascrovasculature.

Smartphones, smartwatches and heart rate tracking devices are the most commonly used devices to feature PPG. In a published literature assessing smartphone apps using PPG for heart rate monitoring, it has found that these devices are reasonably accurate, with correlation coefficients > 0.93 and mean absolute percentage errors ranging from 3.3% to 6.2%. Although PPG sensors were initially only designed to track heart rate, there has been a push to use these with algorithms in the detection of arrhythmias such as AF, and other fields.

Diabetic patients have a two to three-fold higher risk of developing cardiovascular disease, and that cardiovascular diseases accounted for 29.2% of all deaths in Singapore. Wearable devices are ubiquitous, easy to use, and may allow for screening and further monitoring of a large population of patients.

This research proposes to leverage PPG technology, together with artificial intelligence, and incorporate this into affordable wearable lifestyle devices, wrist-worn and in-ear, to accurately monitor continuously and non-invasively glucose levels in humans. A simple non-invasive tool to monitor blood glucose will be developed, and alerts will be issued when the blood glucose level falls in the unhealthy range. The standard glucometer will be used to calibrate and validate the PPG measurements of blood glucose. This study targets to recruit and measure the blood glucose of 500 participants from KK Women's and Children's Hospital.

The primary aims of this study are: (1) Calibrate and validate PPG measurements of blood glucose, obtained both the wrist-worn and in-ear PPG devices, against the standard glucometer; (2) To develop a risk prediction model to identify subjects with blood glucose in the unhealthy range, using both subject characteristics and important features extracted from the PPG measurements using machine learning techniques.

The secondary aim of this study is to validate that in-ear and wrist-worn wearables both provide relative accurate heart rate and heart rate interval measurements.

Being tested
Actxa BGM Tracker (GLO2), SVT In-Ear Prototype (IEP)
Keywords
Blood Glucose Monitoring, Wearable, Photoplethysmography (PPG), Diabetes
Medical subject headings
Diabetes Mellitus

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Actxa BGM Tracker (GLO2)Device

    Wrist-worn wearable

  • SVT In-Ear Prototype (IEP)Device

    In-Ear wearable

Study groups in NCT05504096
Study groupRoleWhat they receive
Single-Arm: Healthy ParticipantsOtherAll participants will be administered with the In-Ear and Wearable devices concurrently for 8 minutes while the application records the readings from the devices. Participants with the first glucometer reading of less than 11.1 mmol/L will be required to return one-hour post sugary drink consumption for a second reading with both devices.
Receives: Device: Actxa BGM Tracker (GLO2); Device: SVT In-Ear Prototype (IEP)

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Capillary blood glucose level using the glucometer and PPG signal readings

    Raw PPG signal readings obtained from the devices will be collected via an application on a phone. Capillary glucose reading will be obtained using a glucometer at the same sitting.

    Measured: Both the PPG signals and capillary blood glucose will be collected at the same time during the visit lasting up to 2 hour per subject. A total of 500 subjects will be recruited up to 6 months

  2. Risk prediction model of diabetes using PPG features on the wearables

    This study aims to develop means for non-invasive measurement of blood glucose and to assist with the early detection of diabetes among subjects who do not exhibit any noticeable signs of the disease.

    PPG data will be collected from the wearables, and the standard glucometer will be used to calibrate and validate these PPG measurements of blood glucose. The objective is to calibrate and evaluate PPG as a means for assessing and monitoring blood glucose levels.

    The effects of each of the PPG variables collected will be assessed by its ability to detect an increased blood glucose level, in terms of sensitivity, specificity, and positive and negative predictive values.

    A risk prediction model will be developed to identify subjects with blood glucose in the unhealthy range, using both subject characteristics and important features extracted from the PPG measurements using artificial intelligence and machine learning techniques.

    Measured: The study will be completed within 6 months involving 500 subjects. Data analysis and risk prediction model will be completed up to 12 months

Secondary outcomes (1)
  1. Validate that in-ear and wrist-worn wearables both provide relative accurate heart rate and heart rate interval measurements.

    Smartwatches in the market have been shown to provide relatively accurate data as to the measurement of heart rate and this feature has been incorporated into newly developed smartwatches.

    In this study, PPG data collected will be used to assess by its ability to detect heart rate and heart rate intervals, in terms of sensitivity, specificity, and positive and negative predictive values.

    Measured: Subjects will be assessed at one visit study. Total duration of the study is 15mins for subjects whose capillary blood glucose is greater than or equal to 11.1mmol/L, and about 90minutes for those less than 11.1mmol/L.

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted17 Aug 2022
  2. Study start8 Oct 2021
  3. Primary completion18 Feb 2023
  4. Study completion18 Feb 2023

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Other
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
500 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05504096
Sponsor's protocol ID
2020/2968
Status last verified
Feb 2023
First submitted
19 Nov 2021
Last updated
21 Feb 2023
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No

Publications

  • Kviesis-Kipge, E., Zaharans, J., Rubenis, O., & Grabovskis, A. A photoplethysmography device for multipurpose blood circulatory system assessment. In European Conference on Biomedical Optics (p. 80900W). Optical Society of America.

  • Monte-Moreno E. Non-invasive estimate of blood glucose and blood pressure from a photoplethysmograph by means of machine learning techniques. Artif Intell Med. 2011 Oct;53(2):127-38. doi: 10.1016/j.artmed.2011.05.001. Epub 2011 Jun 22.

    PubMed 21696930
  • Philip, L.A., Rajasekaran, K., & Smily Jeya Jothi, E. Continuous monitoring of blood glucose using photophlythesmograph signal. Proceedings of IEEE International Conference on Innovations in Electrical, Electronics, Instrumentation and Media Technology (ICEEIMT). 2017: 187-191

  • Hina, H. Nadeem and W. Saadeh, A Single LED Photoplethysmography-Based Noninvasive Glucose Monitoring Prototype System. 2019 IEEE International Symposium on Circuits and Systems (ISCAS). 2019; 1-5

  • De Ridder B, Van Rompaey B, Kampen JK, Haine S, Dilles T. Smartphone Apps Using Photoplethysmography for Heart Rate Monitoring: Meta-Analysis. JMIR Cardio. 2018 Feb 27;2(1):e4. doi: 10.2196/cardio.8802.

    PubMed 31758768

Questions about this trial

What is this clinical trial studying?

A study testing Actxa BGM Tracker (GLO2) and SVT In-Ear Prototype (IEP) in people with Blood Glucose, High and Blood Glucose, Low, run by KK Women's and Children's Hospital at 1 site in Singapore.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 21 Feb 2023. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Singapore. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Capillary blood glucose level using the glucometer and PPG signal readings (time frame: Both the PPG signals and capillary blood glucose will be collected at the same time during the visit lasting up to 2 hour per subject. A total of 500 subjects will be recruited up to 6 months). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT05504096, which also lists 5 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 21 Feb 2023.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in