AzTrials
AzTrials

Cataract SenileEMVNCT05417633

RayOne EMV Mini-monovision - Efficiency and Safety of 3 Grades of Mini-monovision

A study testing intraocular lens - RayOne EMV (Rayner Surgical GmbH,Berlin, Deutschland) in people with Cataract Senile and Presbyopia, run by Somich, s.r.o. at 1 site in Czechia.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

Aim:To determine the effectiveness and subjective satisfaction of patients with bilateral cataract surgery and implantation of intraocular lens (IOL) RayOne EMV with enhanced optic, using different degrees of mini-monovision (up to 0.74, between 0.75 -1.24 and 1.25-1.75). Read more about this study

Who is it for?
Ages 50 years and older
Conditions the study is for
Cataract Senile, Presbyopia
What is being tested?
intraocular lens - RayOne EMV (Rayner Surgical GmbH,Berlin, Deutschland)
Type of treatment
Surgery or procedure
Could I receive a placebo?
No, everyone receives an active treatment
How many people
60 participants
Where
1 siteCzechia
Study dates
1 Jan 2022to 21 Mar 2023
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 50 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • bilateral senile cataract

Who cannot join

  • corneal astigmatism greater than 0.75 diopters (D)
  • difference in the planned dioptric value of intraocular lens (IOL) over 2 D (calculated for bilateral emetropia)
  • perioperative complications not allowing proper implantation and centering of IOL in the lens bag
  • time between surgeries of both eyes greater than 1 month
  • eye disease, which could reduce visual acuity
  • previous refractive surgeries
  • systemic diseases that could affect postoperative visual acuity

Trial locations and contacts

1 site in 1 country.

Pavel Studeny, MD contact

00420775555342

studenypavel@seznam.cz

Czechia1 site, 1 recruiting
  • Somich

    Karlovy Vary, 36006

    Pavel Studeny, MD, 00420775555342, studenypavel@seznam.cz

    Recruiting

Other trials in Czechia

About this study

Aim:To determine the effectiveness and subjective satisfaction of patients with bilateral cataract surgery and implantation of intraocular lens (IOL) RayOne EMV with enhanced optic, using different degrees of mini-monovision (up to 0.74, between 0.75 -1.24 and 1.25-1.75). To compare individual groups between themselves . In particular, we would like to compare the independence of spectacle correction when looking into the distance, at medium distance and at reading distance.

Read the detailed description

Purpose: To determine the effectiveness and subjective satisfaction of patients with bilateral cataract surgery and implantation of intraocular lens (IOL) RayOne EMV with enhanced optic, using different degrees of mini-monovision (up to 0.74, between 0.75 -1.24 and 1.25-1.75). To compare individual groups between themselve

Preoperative examination - Eye dominance - hole in card method Argos optical biometrics (Movu, Inc., CA, U.S.) Barrett's formulas (Barrett universal II) will be used to calculate the optimal IOL. A RayOne EMV lens with a planned postoperative spherical equivalent (SE) of -0.25 to 0.25 will be implanted in the dominant eye. A lens with a planned SE of -0.25 to -0.74 will be implanted in the non-dominant eye in the first group, -0.75 to -1.24 in the second group and -1.25 to -1.75 in the third group.

Surgery Standard course of surgery, corneal incision at No. 12, combination of topical and intracameral anesthesia, implantation of IOL into the capsular bag, primary posterior capsulorhexis (PPCCC) performed after implantation.

Postoperative evaluation In addition to standard postoperative examinations (anterior segment condition, intraocular pressure), the resulting refraction will be monitored postoperatively (3 and 6 months after second eye surgery) using an autorefractometer.

Uncorrected (UCVA) and corrected distance visual acuity (DCVA) will be examined using projection optotypes. Uncorrected (UIVA) medium distance visual acuity (60 cm) and uncorrected (UNVA) and corrected (CNVA) near visual acuity (30 cm) using standardized EDTRS reading tables. All values of visual acuity will be examined monocularly and binocularly (bUCVA, bDCVA, bUNVA, bCNVA, bUIVA). Visual acuity values will be expressed in logMAR.

Binocular Contrast sensitivity will be examined using a Glaretester CGT 1000 instrument (Takagi, Seiko Co. Ltd., Nagano, Japan) at a distance (test distance) of 30 cm, 60 cm 5 m. (day), type of glare, low glare, presentation duration of test target 0.8 s, presentation interval of test target 2 s. The resulting values will be expressed numerically and graphically in comparison with the standard .

Patients will be asked to complete questionnaires:

  1. the occurrence of secondary visual symptoms (eg halo - ring around the light source, glare - fog around the light source and starbursts - rays around the light source). Patients will rate these side effects on a scale of 0 - 5 (0 - none, 1 - very mild, 2 - mild 3 - moderate 4 - severe 5 - very severe).
  2. for independence on glasses a) at close range b) at medium distance c) at a distance. Patients rate on a scale of 1 - 5 (1 - never uses glasses, 2 - exceptionally uses glasses 3 - occasionally uses glasses 4 - often uses glasses 5 - always uses glasses).
  3. Satisfaction with the result of the operation. Patients rate on a scale of 1 - 5 (1 - very satisfied 2 - rather satisfied 3 - neutral 4 - rather dissatisfied 5 - very dissatisfied).
  4. Statistical analysis - descriptive data describing the group of patients and visual, refractive results and contrast sensitivity and questionnaires will be processed. The Wilcoxon signed-rank test will be used to compare preoperative and postoperative visual acuity. The Mann-Whitney U test will be used to compare visual symptoms and patient satisfaction in each group
Being tested
intraocular lens - RayOne EMV (Rayner Surgical GmbH,Berlin, Deutschland)
Keywords
Intraocular lens enhanced, minimonovision
Medical subject headings
Presbyopia

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • intraocular lens - RayOne EMV (Rayner Surgical GmbH,Berlin, Deutschland)Procedure or surgery

    Inducing different values of monovision

Study groups in NCT05417633
Study groupRoleWhat they receive
Group 1Active comparatormonovision 0.25 - 0.74 D
Receives: Procedure: intraocular lens - RayOne EMV (Rayner Surgical GmbH,Berlin, Deutschland)
Group 2Active comparatormonovision 0.75 -1.24 D
Receives: Procedure: intraocular lens - RayOne EMV (Rayner Surgical GmbH,Berlin, Deutschland)
Group 3Active comparatormonovision 1.24 - 1.75
Receives: Procedure: intraocular lens - RayOne EMV (Rayner Surgical GmbH,Berlin, Deutschland)

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. visual acuity (VA)

    uncorrected for distance (UDVA), intermediate distance (UIVA), near (UNVA) corrected for distance (CDVA), intermediate distance (CIVA), near (CNVA)

    Measured: 3-6 months

  2. sS Subjective satisfaction

    questionnaire of subjective satisfaction, dependence on glasses, incidence of secondary visual phenomena - scale 1-5

    Measured: 3-6 months

Secondary outcomes (1)
  1. contrast sensitivity

    Glaretester

    Measured: 3-6 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted14 Jun 2022
  2. Study start1 Jan 2022
  3. Primary completion31 Dec 2022 (estimated)
  4. Study completion21 Mar 2023 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
Double blind
Who is masked
Participant, Care provider
Enrolment
60 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05417633
Sponsor's protocol ID
Somich
Acronym
EMV
Status last verified
Jun 2022
First submitted
2 May 2022
Last updated
14 Jun 2022
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No: one researcher

Publications

  • Boerner CF, Thrasher BH. Results of monovision correction in bilateral pseudophakes. J Am Intraocul Implant Soc. 1984 Winter;10(1):49-50. doi: 10.1016/s0146-2776(84)80077-4.

    PubMed 6706816
  • Rodov L, Reitblat O, Levy A, Assia EI, Kleinmann G. Visual Outcomes and Patient Satisfaction for Trifocal, Extended Depth of Focus and Monofocal Intraocular Lenses. J Refract Surg. 2019 Jul 1;35(7):434-440. doi: 10.3928/1081597X-20190618-01.

    PubMed 31298723
  • Shen Z, Lin Y, Zhu Y, Liu X, Yan J, Yao K. Clinical comparison of patient outcomes following implantation of trifocal or bifocal intraocular lenses: a systematic review and meta-analysis. Sci Rep. 2017 Mar 28;7:45337. doi: 10.1038/srep45337.

    PubMed 28422087
  • Abdelrazek Hafez T, Helaly HA. Spectacle Independence And Patient Satisfaction With Pseudophakic Mini-Monovision Using Aberration-Free Intraocular Lens. Clin Ophthalmol. 2019 Oct 31;13:2111-2117. doi: 10.2147/OPTH.S215229. eCollection 2019.

    PubMed 31802840
  • Wilkins MR, Allan BD, Rubin GS, Findl O, Hollick EJ, Bunce C, Xing W; Moorfields IOL Study Group. Randomized trial of multifocal intraocular lenses versus monovision after bilateral cataract surgery. Ophthalmology. 2013 Dec;120(12):2449-2455.e1. doi: 10.1016/j.ophtha.2013.07.048. Epub 2013 Sep 23.

    PubMed 24070808
  • de Vries NE, Nuijts RM. Multifocal intraocular lenses in cataract surgery: literature review of benefits and side effects. J Cataract Refract Surg. 2013 Feb;39(2):268-78. doi: 10.1016/j.jcrs.2012.12.002.

    PubMed 23332253
  • Greenstein S, Pineda R 2nd. The Quest for Spectacle Independence: A Comparison of Multifocal Intraocular Lens Implants and Pseudophakic Monovision for Patients with Presbyopia. Semin Ophthalmol. 2017;32(1):111-115. doi: 10.1080/08820538.2016.1228400. Epub 2016 Oct 28.

    PubMed 27792408

Questions about this trial

What is this clinical trial studying?

A study testing intraocular lens - RayOne EMV (Rayner Surgical GmbH,Berlin, Deutschland) in people with Cataract Senile and Presbyopia, run by Somich, s.r.o. at 1 site in Czechia.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 7 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 14 Jun 2022. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Czechia. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Pavel Studeny, MD (00420775555342, studenypavel@seznam.cz), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

visual acuity (VA) (time frame: 3-6 months). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT05417633, which also lists 7 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 14 Jun 2022.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.