GlaucomaNCT05014386
AGV Implantation With Ologen in Pediatric Glaucomas
A study testing Ahmed Glaucoma Valve Implantation in secondary pediatric glaucomas. and Ahmed Glaucoma Valve Implantation with Ologen augmentation in secondary pediatric glaucomas in people with Glaucoma, run by Mansoura University.
Trial summary
Ahmed Glaucoma Valve Implantation with Ologen augmentation in secondary pediatric glaucomas: A 2-year randomized controlled trial. Background: Many studies have investigated the clinical benefits of Ologen for trabeculectomy. Read more about this study
- Who is it for?
- Ages 1 month to 16 years
- Conditions the study is for
- Glaucoma
- What is being tested?
- Ahmed Glaucoma Valve Implantation in secondary pediatric glaucomas. and Ahmed Glaucoma Valve Implantation with Ologen augmentation in secondary pediatric glaucomas
- Type of treatment
- Surgery or procedure
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 40 participants
- Where
- No sites listed yet
- Study dates
- Aug 2021to Jan 2024
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 1 month to 16 years
- All sexes
- No healthy volunteers
- Child
Who may be able to join
- Refractory pediatric glaucoma was defined by at least 2 repeated IOP measurements greater than 21 mmHg and accompanying signs of buphthalmos, corneal edema, Haabs striae, or optic nerve cupping despite maximal tolerated medical therapy.
Who cannot join
- Primary congenital glaucoma
Trial locations and contacts
No sites are listed yet.
About this study
Official title: Ahmed Glaucoma Valve Implantation With Ologen Augmentation in Secondary Pediatric Glaucomas
Ahmed Glaucoma Valve Implantation with Ologen augmentation in secondary pediatric glaucomas: A 2-year randomized controlled trial.
Background:
Read more
Many studies have investigated the clinical benefits of Ologen for trabeculectomy. However, its benefits for Ahmed glaucoma valve implantation have not been widely investigated.
Purpose:
The aim of this study was to compare the 2-year outcomes of AGV implantation with and without Ologen adjuvant for the treatment of children with 2ry pediatric glaucoma. Design: This is a single-center, randomized, controlled study. Participants: Consecutive children with refractory pediatric glaucoma requiring AGV implantation were enrolled in this study.
Methods:
Refractory pediatric glaucoma was defined by at least 2 repeated IOP measurements greater than 21 mmHg and accompanying signs of buphthalmos, corneal edema, Haabs striae, or optic nerve cupping despite maximal tolerated medical therapy. The primary outcome measure was AGV success. Complete success was defined as intraocular pressure (IOP) between 6 and 20 mmHg without glaucoma medications and additional IOP-lowering surgeries. Qualified success was defined as above, except IOP control maintained with glaucoma medications. In Ologen eyes, a round 12 × 1 mm circular Ologen disc will be placed over the FP7 or FP8 AGV-plate immediately before conjunctival closure. Control eyes received conventional FP7 or FP8 AGV surgery without Ologen augmentation.
Read the detailed description
Ahmed Glaucoma Valve Implantation with Ologen augmentation in secondary pediatric glaucomas: A 2-year randomized controlled trial.
Background:
The management of secondary pediatric glaucoma is challenging in terms of maintaining lifelong vision and avoiding an aggressive scarring course after surgery. Secondary Pediatric glaucoma includes a variety of ocular conditions that lead to high intraocular pressure (IOP) and progressive optic neuropathy. Glaucoma is a well-known complication of congenital cataract extraction and is the most frequent long-term complication of lensectomy with or without intraocular lens (IOL) implantation. The reported incidence in the literature is between 15% and 45%4. Another cause is aphakic glaucoma.Management of secondary pediatric glaucoma is mainly surgical, and medical therapy is used either as a temporizing measure or as an adjunctive treatment.
Traditionally, "staged approach" has been favored by many ophthalmologists. This involves starting with angle surgeries and their repetition in the case of failure, proceeding with trabeculectomy or combined trabeculotomy-trabeculectomy for refractory patients, and drainage device or cyclodestruction for very advanced patients.The poor clinical outcomes prompted surgeons to adapt glaucoma drainage devices (GDDs) as a mainstay of treatment for refractory glaucoma in both pediatric and adult populations.In children, Ahmed glaucoma valves (AGV) have greater than 80% success rate at 1- year, but success decreases to less than 50% by 5 years2. In order to improve long-term IOP control, mitomycinC (MMC) has been used as an adjuvant during implant placement. While MMC is a commonplace in trabeculectomy, its use with GDDs is controversial due to increased complications such as bleb leaks and endothelial cell damage. More recently, Ologen, a biodegradable Type-I collagen matrix, has been used in glaucoma surgeries. Ologen is safe and effective in enhancing trabeculectomy surgery in adults and children,.
Many studies have investigated the clinical benefits of Ologen for trabeculectomy. However, its benefits for Ahmed glaucoma valve implantation have not been widely investigated. Reports in adult patients have shown that Ologen may increase AGV success and decrease hypertensive phase incidence. Many studies have investigated the clinical benefits of Ologen for trabeculectomy. However, its benefits for Ahmed glaucoma valve implantation have not been widely investigated. As glaucoma drainage devices are being increasingly used for pediatric glaucoma,investigators decided to report the results and safety of Ahmed glaucoma valve (AGV) implantation in a series of secondary pediatric glaucoma as well as the clinical benefits of concomitant use Ologen as an adjuvant for for Ahmed glaucoma valve implantation .
Purpose:
The aim of this study was to compare the 2-year outcomes of AGV implantation with and without Ologen adjuvant for the treatment of children with 2ry pediatric glaucoma.
Design:
This is a single-center, randomized, controlled study.
Participants:
Consecutive children with refractory pediatric glaucoma requiring AGV implantation were enrolled in this study.
Methods:
Refractory pediatric glaucoma was defined by at least 2 repeated IOP measurements greater than 21 mmHg and accompanying signs of buphthalmos, corneal edema, Haabs striae, or optic nerve cupping despite maximal tolerated medical therapy. The primary outcome measure was AGV success. Complete success was defined as intraocular pressure (IOP) between 6 and 20 mmHg without glaucoma medications and additional IOP-lowering surgeries. Qualified success was defined as above, except that IOP control was maintained with glaucoma medications.
Surgical procedure:
A 7-0 silk traction suture was placed through the clear cornea.A conjunctival incision was made 4 mm posterior to the limbus in the supratemporal quadrant. After dissecting conjunctiva and Tenon's primed FP7 or FP8 AGV was inserted into the subconjunctival space and sutured to sclera using two interrupted 7-0 silk sutures 8-10 mm posterior to the limbus. A 23-gauge needle was used to enter the anterior chamber from the surgical limbus. The tube then was cut beveled up and inserted into the anterior chamber through the tunnel. In Ologen eyes, a round 12 × 1 mm circular Ologen disc will be placed over the FP7 or FP8 AGV-plate immediately before conjunctival closure. Control eyes received conventional FP7 or FP8 AGV surgery without Ologen augmentation.
Finally, conjunctiva and Tenon were approximated using a running 8-0 Vicryl suture.At the close of surgery, subtenon antibiotic and steroids were injected in all cases.
Data collection:
Preoperative data including age at the time of surgery, sex,laterality, type of glaucoma, prior ocular history, prior surgical treatment, number of glaucoma medications, IOP, cup to disc ratio, and central corneal thickness (CCT) were extracted from patients' record. Postoperative data included follow-up durations; IOP at months 3, 6, 12, 24, and 36; cup to disc ratios at months 12, 24,; and intraoperative and postoperative complications. In all cases, IOPs were measured by Tono-Pen (Mentor, Woburn, MA, USA) under anesthesia. In the clinic, IOPs were measured by ICare (ICare Finland Oy, Helsinki, Finland) and Goldmann applanation tonometer (Haag-Streit, Köniz, Switzerland).
Statistical analysis:
All statistical analysis was accomplished using IBM SPSS version 20. Assessment of the data normality was done using both Histogram plot and Shapiro-Wilk's test. Wilcoxon test was used to compare the preoperative and postoperative variables in each group. The comparison between the two groups was done using Mann-Whitney test for numerical variables and Chi-square test for categorical variables. Kaplan-Meier survival curve was plotted to estimate the mean survival time and probabilities of failure at different follow-up stages in the both groups. For all tests, P value of less than 0.05 was considered significant.
- Conditions
- Glaucoma
- Being tested
- Ahmed Glaucoma Valve Implantation in secondary pediatric glaucomas., Ahmed Glaucoma Valve Implantation with Ologen augmentation in secondary pediatric glaucomas
- Keywords
- Ahmed Glaucoma Valve, Ologen, secondary pediatric glaucomas
- Medical subject headings
- Glaucoma
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Ahmed Glaucoma Valve Implantation in secondary pediatric glaucomas.Procedure or surgery
A 7-0 silk traction suture was placed through the clear cornea.A conjunctival incision was made 4 mm posterior to the limbus in the supratemporal quadrant. After dissecting conjunctiva and Tenon's primed FP7 or FP8 AGV was inserted into the subconjunctival space and sutured to sclera using two interrupted 7-0 silk sutures 8-10 mm posterior to the limbus. A 23-gauge needle was used to enter the anterior chamber from the surgical limbus. The tube then was cut beveled up and inserted into the anterior chamber through the tunnel. Finally, conjunctiva and Tenon were approximated using a running 8-0 Vicryl suture.At the close of surgery, subtenon antibiotic and steroids were injected in all cases.
Ahmed Glaucoma Valve Implantation with Ologen augmentation in secondary pediatric glaucomasProcedure or surgery
A 7-0 silk traction suture was placed through the clear cornea.A conjunctival incision was made 4 mm posterior to the limbus in the supratemporal quadrant. After dissecting conjunctiva and Tenon's primed FP7 or FP8 AGV was inserted into the subconjunctival space and sutured to sclera using two interrupted 7-0 silk sutures 8-10 mm posterior to the limbus. A 23-gauge needle was used to enter the anterior chamber from the surgical limbus. The tube then was cut beveled up and inserted into the anterior chamber through the tunnel. a round 12 × 1 mm circular Ologen disc will be placed over the FP7 or FP8 AGV-plate immediately before conjunctival closure. Finally, conjunctiva and Tenon were approximated using a running 8-0 Vicryl suture.At the close of surgery, subtenon antibiotic and steroids were injected in all cases.
| Study group | Role | What they receive |
|---|---|---|
| Ahmed Glaucoma Valve Implantation | Active comparator | A 7-0 silk traction suture was placed through the clear cornea.A conjunctival incision was made 4 mm posterior to the limbus in the supratemporal quadrant. After dissecting conjunctiva and Tenon's primed FP7 or FP8 AGV was inserted into the subconjunctival space and sutured to sclera using two interrupted 7-0 silk sutures 8-10 mm posterior to the limbus. A 23-gauge needle was used to enter the anterior chamber from the surgical limbus. The tube then was cut beveled up and inserted into the anterior chamber through the tunnel. Finally, conjunctiva and Tenon were approximated using a running 8-0 Vicryl suture.At the close of surgery, subtenon antibiotic and steroids were injected in all cases. Receives: Procedure: Ahmed Glaucoma Valve Implantation in secondary pediatric glaucomas. |
| Ologen augmentation group | Active comparator | In addition to what is planned for the other Arm;, a round 12 × 1 mm circular Ologen disc will be placed over the FP7 or FP8 AGV-plate immediately before conjunctival closure. Receives: Procedure: Ahmed Glaucoma Valve Implantation with Ologen augmentation in secondary pediatric glaucomas |
What is being measured
The primary outcome is the main question the study is designed to answer.
AGV success
Complete success was defined as intraocular pressure (IOP) between 6 and 20 mmHg without glaucoma medications and additional IOP-lowering surgeries. Qualified success was defined as above, except that IOP control was maintained with glaucoma medications.
Measured: 2 years
Secondary outcomes (2)
cup to disc ratios
cup to disc ratio
Measured: 2 years
postoperative complications
postoperative complications
Measured: 2 years
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted20 Aug 2021
- Study startAug 2021 (estimated)
- Primary completionDec 2023 (estimated)
- Study completionJan 2024 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for GlaucomaStudies of the same condition, open and under way.
- More trials run by Mansoura UniversityThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Model description
- This is a single-center, randomized, controlled couple armed study.
- Masking
- Triple blind
- Who is masked
- Participant, Care provider, Outcomes assessor
- Enrolment
- 40 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Mansoura University
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Amr Mohammed Elsayed Abdelkader, Mansoura University
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT05014386
- Sponsor's protocol ID
- AGV with ologen in SPG
- Status last verified
- Aug 2021
- First submitted
- 13 Aug 2021
- Last updated
- 20 Aug 2021
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- Yes: The (IPD) will be provided as supplemental digital content
Study at a glance
From the registry record, last updated by the sponsor on 20 Aug 2021. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Ahmed Glaucoma Valve Implantation With Ologen Augmentation in Secondary Pediatric Glaucomas
- ClinicalTrials.gov ID
- NCT05014386
- Acronym / sponsor ID
- AGV with ologen in SPG
- Conditions
- Glaucoma
- Keywords
- Ahmed Glaucoma Valve, Ologen, secondary pediatric glaucomas
- Study type
- Interventional
- Recruitment status
- Unknown status
- Enrolment
- 40 participants (estimated)
- Lead sponsor
- Mansoura UniversityUniversity, hospital or other
- Study start
- Aug 2021 (estimated)
- Primary completion
- Dec 2023 (estimated)
- Study completion
- Jan 2024 (estimated)
- First posted
- 20 Aug 2021 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Ahmed Glaucoma Valve Implantation with Ologen augmentation in secondary pediatric glaucomas: A 2-year randomized controlled trial.
Background:
Many studies have investigated the clinical benefits of Ologen for trabeculectomy. However, its benefits for Ahmed glaucoma valve implantation have not been widely investigated.
Purpose:
The aim of this study was to compare the 2-year outcomes of AGV implantation with and without Ologen adjuvant for the treatment of children with 2ry pediatric glaucoma. Design: This is a single-center, randomized, controlled study. Participants: Consecutive children with refractory pediatric glaucoma requiring AGV implantation were enrolled in this study.
Methods:
Refractory pediatric glaucoma was defined by at least 2 repeated IOP measurements greater than 21 mmHg and accompanying signs of buphthalmos, corneal edema, Haabs striae, or optic nerve cupping despite maximal tolerated medical therapy. The primary outcome measure was AGV success. Complete success was defined as intraocular pressure (IOP) between 6 and 20 mmHg without glaucoma medications and additional IOP-lowering surgeries. Qualified success was defined as above, except IOP control maintained with glaucoma medications. In Ologen eyes, a round 12 × 1 mm circular Ologen disc will be placed over the FP7 or FP8 AGV-plate immediately before conjunctival closure. Control eyes received conventional FP7 or FP8 AGV surgery without Ologen augmentation.
Detailed description
Ahmed Glaucoma Valve Implantation with Ologen augmentation in secondary pediatric glaucomas: A 2-year randomized controlled trial.
Background:
The management of secondary pediatric glaucoma is challenging in terms of maintaining lifelong vision and avoiding an aggressive scarring course after surgery. Secondary Pediatric glaucoma includes a variety of ocular conditions that lead to high intraocular pressure (IOP) and progressive optic neuropathy. Glaucoma is a well-known complication of congenital cataract extraction and is the most frequent long-term complication of lensectomy with or without intraocular lens (IOL) implantation. The reported incidence in the literature is between 15% and 45%4. Another cause is aphakic glaucoma.Management of secondary pediatric glaucoma is mainly surgical, and medical therapy is used either as a temporizing measure or as an adjunctive treatment.
Traditionally, "staged approach" has been favored by many ophthalmologists. This involves starting with angle surgeries and their repetition in the case of failure, proceeding with trabeculectomy or combined trabeculotomy-trabeculectomy for refractory patients, and drainage device or cyclodestruction for very advanced patients.The poor clinical outcomes prompted surgeons to adapt glaucoma drainage devices (GDDs) as a mainstay of treatment for refractory glaucoma in both pediatric and adult populations.In children, Ahmed glaucoma valves (AGV) have greater than 80% success rate at 1- year, but success decreases to less than 50% by 5 years2. In order to improve long-term IOP control, mitomycinC (MMC) has been used as an adjuvant during implant placement. While MMC is a commonplace in trabeculectomy, its use with GDDs is controversial due to increased complications such as bleb leaks and endothelial cell damage. More recently, Ologen, a biodegradable Type-I collagen matrix, has been used in glaucoma surgeries. Ologen is safe and effective in enhancing trabeculectomy surgery in adults and children,.
Many studies have investigated the clinical benefits of Ologen for trabeculectomy. However, its benefits for Ahmed glaucoma valve implantation have not been widely investigated. Reports in adult patients have shown that Ologen may increase AGV success and decrease hypertensive phase incidence. Many studies have investigated the clinical benefits of Ologen for trabeculectomy. However, its benefits for Ahmed glaucoma valve implantation have not been widely investigated. As glaucoma drainage devices are being increasingly used for pediatric glaucoma,investigators decided to report the results and safety of Ahmed glaucoma valve (AGV) implantation in a series of secondary pediatric glaucoma as well as the clinical benefits of concomitant use Ologen as an adjuvant for for Ahmed glaucoma valve implantation .
Purpose:
The aim of this study was to compare the 2-year outcomes of AGV implantation with and without Ologen adjuvant for the treatment of children with 2ry pediatric glaucoma.
Design:
This is a single-center, randomized, controlled study.
Participants:
Consecutive children with refractory pediatric glaucoma requiring AGV implantation were enrolled in this study.
Methods:
Refractory pediatric glaucoma was defined by at least 2 repeated IOP measurements greater than 21 mmHg and accompanying signs of buphthalmos, corneal edema, Haabs striae, or optic nerve cupping despite maximal tolerated medical therapy. The primary outcome measure was AGV success. Complete success was defined as intraocular pressure (IOP) between 6 and 20 mmHg without glaucoma medications and additional IOP-lowering surgeries. Qualified success was defined as above, except that IOP control was maintained with glaucoma medications.
Surgical procedure:
A 7-0 silk traction suture was placed through the clear cornea.A conjunctival incision was made 4 mm posterior to the limbus in the supratemporal quadrant. After dissecting conjunctiva and Tenon's primed FP7 or FP8 AGV was inserted into the subconjunctival space and sutured to sclera using two interrupted 7-0 silk sutures 8-10 mm posterior to the limbus. A 23-gauge needle was used to enter the anterior chamber from the surgical limbus. The tube then was cut beveled up and inserted into the anterior chamber through the tunnel. In Ologen eyes, a round 12 × 1 mm circular Ologen disc will be placed over the FP7 or FP8 AGV-plate immediately before conjunctival closure. Control eyes received conventional FP7 or FP8 AGV surgery without Ologen augmentation.
Finally, conjunctiva and Tenon were approximated using a running 8-0 Vicryl suture.At the close of surgery, subtenon antibiotic and steroids were injected in all cases.
Data collection:
Preoperative data including age at the time of surgery, sex,laterality, type of glaucoma, prior ocular history, prior surgical treatment, number of glaucoma medications, IOP, cup to disc ratio, and central corneal thickness (CCT) were extracted from patients' record. Postoperative data included follow-up durations; IOP at months 3, 6, 12, 24, and 36; cup to disc ratios at months 12, 24,; and intraoperative and postoperative complications. In all cases, IOPs were measured by Tono-Pen (Mentor, Woburn, MA, USA) under anesthesia. In the clinic, IOPs were measured by ICare (ICare Finland Oy, Helsinki, Finland) and Goldmann applanation tonometer (Haag-Streit, Köniz, Switzerland).
Statistical analysis:
All statistical analysis was accomplished using IBM SPSS version 20. Assessment of the data normality was done using both Histogram plot and Shapiro-Wilk's test. Wilcoxon test was used to compare the preoperative and postoperative variables in each group. The comparison between the two groups was done using Mann-Whitney test for numerical variables and Chi-square test for categorical variables. Kaplan-Meier survival curve was plotted to estimate the mean survival time and probabilities of failure at different follow-up stages in the both groups. For all tests, P value of less than 0.05 was considered significant.
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Triple blind (participant, care provider, outcomes assessor)
- Number of arms
- 2
- Model description
- This is a single-center, randomized, controlled couple armed study.
| Arm | Type | Receives |
|---|---|---|
| Ahmed Glaucoma Valve Implantation | Active comparator | Procedure: Ahmed Glaucoma Valve Implantation in secondary pediatric glaucomas.A 7-0 silk traction suture was placed through the clear cornea.A conjunctival incision was made 4 mm posterior to the limbus in the supratemporal quadrant. After dissecting conjunctiva and Tenon's primed FP7 or FP8 AGV was inserted into the subconjunctival space and sutured to sclera using two interrupted 7-0 silk sutures 8-10 mm posterior to the limbus. A 23-gauge needle was used to enter the anterior chamber from the surgical limbus. The tube then was cut beveled up and inserted into the anterior chamber through the tunnel. Finally, conjunctiva and Tenon were approximated using a running 8-0 Vicryl suture.At the close of surgery, subtenon antibiotic and steroids were injected in all cases. |
| Ologen augmentation group | Active comparator | Procedure: Ahmed Glaucoma Valve Implantation with Ologen augmentation in secondary pediatric glaucomasIn addition to what is planned for the other Arm;, a round 12 × 1 mm circular Ologen disc will be placed over the FP7 or FP8 AGV-plate immediately before conjunctival closure. |
Who may qualify
- Ages
- 1 month to 16 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Child
Key inclusion criteria (1 listed)
- Refractory pediatric glaucoma was defined by at least 2 repeated IOP measurements greater than 21 mmHg and accompanying signs of buphthalmos, corneal edema, Haabs striae, or optic nerve cupping despite maximal tolerated medical therapy.
Key exclusion criteria (1 listed)
- Primary congenital glaucoma
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Ahmed Glaucoma Valve Implantation in secondary pediatric glaucomas.A 7-0 silk traction suture was placed through the clear cornea.A conjunctival incision was made 4 mm posterior to the limbus in the supratemporal quadrant. After dissecting conjunctiva and Tenon's primed FP7 or FP8 AGV was inserted into the subconjunctival space and sutured to sclera using two interrupted 7-0 silk sutures 8-10 mm posterior to the limbus. A 23-gauge needle was used to enter the anterior chamber from the surgical limbus. The tube then was cut beveled up and inserted into the anterior chamber through the tunnel. Finally, conjunctiva and Tenon were approximated using a running 8-0 Vicryl suture.At the close of surgery, subtenon antibiotic and steroids were injected in all cases. | Procedure or surgery | Ahmed Glaucoma Valve Implantation |
| Ahmed Glaucoma Valve Implantation with Ologen augmentation in secondary pediatric glaucomasA 7-0 silk traction suture was placed through the clear cornea.A conjunctival incision was made 4 mm posterior to the limbus in the supratemporal quadrant. After dissecting conjunctiva and Tenon's primed FP7 or FP8 AGV was inserted into the subconjunctival space and sutured to sclera using two interrupted 7-0 silk sutures 8-10 mm posterior to the limbus. A 23-gauge needle was used to enter the anterior chamber from the surgical limbus. The tube then was cut beveled up and inserted into the anterior chamber through the tunnel. a round 12 × 1 mm circular Ologen disc will be placed over the FP7 or FP8 AGV-plate immediately before conjunctival closure. Finally, conjunctiva and Tenon were approximated using a running 8-0 Vicryl suture.At the close of surgery, subtenon antibiotic and steroids were injected in all cases. | Procedure or surgery | Ologen augmentation group |
Primary outcome
AGV success
Time frame: 2 years
Complete success was defined as intraocular pressure (IOP) between 6 and 20 mmHg without glaucoma medications and additional IOP-lowering surgeries. Qualified success was defined as above, except that IOP control was maintained with glaucoma medications.
2 secondary outcomes
cup to disc ratios
Time frame: 2 years
postoperative complications
Time frame: 2 years
Results and safety
Results are not available in the source record.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 20 Aug 2021.
- Individual participant dataSharing planned: Yes. The (IPD) will be provided as supplemental digital content
Related trials for Glaucoma
Recruiting
Implementing AI-based Glaucoma Screening Within Federally Qualified Health Centers
Glaucoma, Ocular Hypertension
Not yet recruiting
AI-Assisted vs Conventional Teleglaucoma Referral
Glaucoma
Recruiting
Brain Stimulation Effects on Orientation and Mobility Skills in Adults With Vision Impairment
Retinitis Pigmentosa (RP), Rod Cone Dystrophy
Recruiting
Automated Applanation Tonometry - Updated
Glaucoma, Glaucoma, Suspect
RecruitingPhase 2
A Phase 2a Study Comparing the Efficacy, Safety and Tolerability of Pregabalin Eye Drops Comparing With Timolol Eye Drops in Adults With Glaucoma or High Eye Pressure.
Primary Open - Angle Glaucoma (POAG), Ocular Hypertension (OHT)
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Questions about this trial
What is this clinical trial studying?
A study testing Ahmed Glaucoma Valve Implantation in secondary pediatric glaucomas. and Ahmed Glaucoma Valve Implantation with Ologen augmentation in secondary pediatric glaucomas in people with Glaucoma, run by Mansoura University.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 1 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: status not confirmed, as of the sponsor's last update on 20 Aug 2021. Status can change between updates, so confirm with the study contact before making plans.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Results are not available in the source record.
How can a doctor refer a patient or contact the research team?
Contact Amr Mohammed Elsayed A Mohammed, MD, FRCS (01004314242 ext. +20, dramrabdelkader@gmail.com), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
AGV success (time frame: 2 years). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 20 Aug 2021.