Airway ExtubationNCT04356625

Maximum Expiratory Pressure in Induced Cough as a Predictor of Extubation Failure

A study testing MEPic in people with Airway Extubation, run by Hospital Nacional Profesor Alejandro Posadas at 1 site in Argentina.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Clinical trial for the evaluation of diagnostic tests. The sample was composed of adults under mechanical ventilation who passed the spontaneous breathing trial and was ready to be extubated. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Airway Extubation
What is being tested?
MEPic
Could I receive a placebo?
No, everyone receives an active treatment
How many people
80 participants
Where
1 siteArgentina
Study dates
1 Oct 2018to 9 Sep 2019
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Under mechanical ventilation via endotracheal tube in a period greater than 48 hours
  • Passing the spontaneous breathing trial an be ready for extubation.
  • Agree to participate in the study and sign the informed consent by the patient or family member

Who cannot join

  • tracheostomized prior to admission to mechanical ventilation
  • history of neuromuscular disease
  • presence of unstable heart disease
  • received upper digestive surgery
  • presence of uncontained enterocutaneous fistula
  • candidates for non-invasive ventilation as a modality of interface exchange for extubation or as a preventive modality
  • patients who did not reach a MEP (habitual) of 30 cmH20 since they are not extubated by the extubation protocol of our institution.

Trial locations and contacts

1 site in 1 country.

Argentina1 site
  • Ladislao Diaz Ballve

    Haedo, Buenos Aires, 1706

Other trials in Argentina

About this study

Official title: Maximum Expiratory Pressure in Induced Cough as a Predictor of Extubation Failure in Intensive Care Unit Patients on Mechanical Ventilation Ready to Extubate. A Single-arm Open Clinical Trial.

Clinical trial for the evaluation of diagnostic tests. The sample was composed of adults under mechanical ventilation who passed the spontaneous breathing trial and was ready to be extubated. The maximum expiratory pressure measured in the usual way and the maximum expiratory pressure generated during the induced cough were taken as predictor variables. The outcome variable was extubation failure, measured at 72 hours and at 7 days.

Read the detailed description

After completing the spontaneous breathing trial (SBT), with the extubation decision defined by the physician in charge of the patient and maximal expiratory pressure (MEP) as usually measured greater than 30 centimeters of water (cmH2O). Following this, the patient was allowed to rest for 5 minutes in the same condition. With the patient in the supine position sitting 45 ° to 60 °, the closed suction catheter was removed, an elbow was placed at 90 ° and a bacterial filter in series with the endotracheal tube (ET), an adapter was also coupled with a outlet port to the aneroid pressure gauge. In series an inspiratory unidirectional valve was placed that did not allow expiration. Immediately 2 ml of physiological solution was slowly instilled through the port in the 90º elbow to trigger the cough reflex. The presence or absence of reflex cough and the MEP during induced cough (MEPic) value were verified.

As a safety method, the procedures were stopped if the patient presented signs of intolerance such as respiratory rate (RF)> 35 breaths per minute, saturation <90%, heart rate (HR)> 140 beats per minute or increase of 20 % of resting levels.

Being tested
MEPic
Keywords
airway extubation, maximal expiratory pressure, induced cough, ventilator weaning

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • MEPicDiagnostic test

    • patient in the supine position sitting 45° to 60°,
    • closed suction catheter was removed
    • a 90° elbow was placed and a bacterial filter in series with endotracheal tube
    • adapter was also coupled to the aneroid pressure gauge
    • in series an inspiratory unidirectional valve was placed that did not allow expiration
    • 2 ml of physiological solution was slowly instilled through the port in the 90º elbow to cause induced cough
Study groups in NCT04356625
Study groupRoleWhat they receive
MEPicOther* Ready for extubation (pass SBT) * Measurement of maximum expiratory pressure during the induced cough (MEPic)
Receives: Diagnostic Test: MEPic

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Extubation failure

    Endotracheal tube removal failure

    Measured: 72 hours

  2. Extubation failure

    Endotracheal tube removal failure

    Measured: 7 days

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted22 Apr 2020
  2. Study start1 Oct 2018
  3. Primary completion1 Sep 2019
  4. Study completion9 Sep 2019

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Not applicable
Intervention model
Single group
Model description
Single-arm clinical trial to establish diagnostic performance of MEPic
Masking
None (open label)
Enrolment
80 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04356625
Sponsor's protocol ID
209LUP0S0/18
Status last verified
Apr 2020
First submitted
20 Apr 2020
Last updated
4 May 2020
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Carrera M, Urrutia JG, Ardariz CB, Porra ML, Gamarra C, Ballve LPD. Maximal expiratory pressure compared with maximal expiratory pressure during induced cough as a predictor of extubation failure. Crit Care Sci. 2023 Mar 1;35(1):37-43. doi: 10.5935/2965-2774.20230275-en.

    PubMed 37712728

Questions about this trial

What is this clinical trial studying?

A study testing MEPic in people with Airway Extubation, run by Hospital Nacional Profesor Alejandro Posadas at 1 site in Argentina.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 7 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 4 May 2020. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Argentina. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Extubation failure (time frame: 72 hours). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT04356625, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 4 May 2020.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in