Cone Beam Computed Tomography (CBCT) has been used to assess the volume of the maxillary sinus using the manual and semi-automatic segmentation. The majority of researches stressed on the reduced accuracy of the automatic segmentation when compared to the real volume. Read more about this study

Who is it for?
Any ageHealthy volunteers can take part
Conditions the study is for
Sinus Volume, CBCT Segmentation
What is being tested?
semiautomatic software
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
10 participants
Where
No sites listed yet
Study dates
1 Oct 2019to 1 Sep 2020
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages Any age
  • All sexes
  • Healthy volunteers accepted
  • Child, Adult, Older adult

Who may be able to join

  • -
  • Inclusion Criteria of participants of the In vitro part of the study:
  • Skulls with intact walls of maxillary sinus.
  • Skulls with dentulous or edentulous jaws.

Who cannot join

  • Skulls with missing parts of the maxilla that could be caused from traumatic injuries, diseases and space occupying lesions of maxilla.
  • Skulls with severe mutilation caused by environmental decay.
  • Inclusion Criteria of participants of the In vivo part of the study:
  • Patients without any pathosis affects maxillary sinus.
  • Patients with dentulous or edentulous jaws.
  • Patients with traumatic injuries, diseases and space occupying lesions of maxilla.
  • Patients with sinus lifting or surgeries.
  • Patients with mucosal thickening more than 3mm

Trial locations and contacts

No sites are listed yet.

About this study

Official title: Cone Beam Computed Tomographic Segmentation in Volumetric Measurements of Maxillary Sinus Using Different Soft Wares: A Validity and Reliability Study

Cone Beam Computed Tomography (CBCT) has been used to assess the volume of the maxillary sinus using the manual and semi-automatic segmentation. The majority of researches stressed on the reduced accuracy of the automatic segmentation when compared to the real volume. Regarding the semi-automatic segmentation, there are researches assessed the volumetric measurement of the maxillary sinus and they reported that there is no significant difference between semi- automatic and the manual segmentation in CT.

Read the detailed description

Automatic segmentation is believed to be less time consuming and more accurate in assessment of structures with regular border but fairly assessed the structures with irregular border like paranasal sinuses. The semi-automatic software is efficient and accurate as manual tracing with significant reduction in inter-observer variability and time . On the other hand, all neighboring contacting voxels located within a defined range (threshold) of similar HU values of different adjacent tissues may be measured so over calculation or under calculation could be suspected

Being tested
semiautomatic software
Keywords
CBCT, maxillary sinus, segmentation

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • semiautomatic softwareDevice

    Also called Mimics medical 19., Romexis, On Demand 3D

    semiautomatic segmentation is as accurate as the direct volume of maxillary sinus and as well as the manual segmentation.

Study groups in NCT04092699
Study groupRoleWhat they receive
patientOtherCBCT Dicom file of patient has been scanned will be used for measurements of maxillary sinus volume by different software
Receives: Device: semiautomatic software
skullsOtherCBCT Dicom file of patient has been scanned will be used for measurements of maxillary sinus volume by different software
Receives: Device: semiautomatic software

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Validity and reliability of CBCT semiautomatic segmentation in Volumetric measurements of maxillary sinus.

    validity and reliability

    Measured: 1 year

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted17 Sep 2019
  2. Study start1 Oct 2019 (estimated)
  3. Primary completion1 Jun 2020 (estimated)
  4. Study completion1 Sep 2020 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Device feasibility
Allocation
Randomised
Intervention model
Sequential
Masking
Single blind
Who is masked
Outcomes assessor
Enrolment
10 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04092699
Sponsor's protocol ID
Dentistry
Status last verified
Sep 2019
First submitted
11 Sep 2019
Last updated
17 Sep 2019
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Undecided

Publications

  • Berberi A, Bouserhal L, Nader N, Assaf RB, Nassif NB, Bouserhal J, Salameh Z. Evaluation of Three-Dimensional Volumetric Changes After Sinus Floor Augmentation with Mineralized Cortical Bone Allograft. J Maxillofac Oral Surg. 2015 Sep;14(3):624-9. doi: 10.1007/s12663-014-0736-3. Epub 2014 Dec 24.

    PubMed 26225054
  • Alsufyani NA, Flores-Mir C, Major PW. Three-dimensional segmentation of the upper airway using cone beam CT: a systematic review. Dentomaxillofac Radiol. 2012 May;41(4):276-84. doi: 10.1259/dmfr/79433138.

    PubMed 22517995
  • El H, Palomo JM. Measuring the airway in 3 dimensions: a reliability and accuracy study. Am J Orthod Dentofacial Orthop. 2010 Apr;137(4 Suppl):S50.e1-9; discussion S50-2. doi: 10.1016/j.ajodo.2010.01.014.

    PubMed 20381759

Questions about this trial

What is this clinical trial studying?

A study testing semiautomatic software in people with Sinus Volume and CBCT Segmentation, run by Cairo University.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 8 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 17 Sep 2019. Status can change between updates, so confirm with the study contact before making plans.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Reham Ashraf, master (01027518071 ext. 01027518071, reham.ashraf87@yahoo.com), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Validity and reliability of CBCT semiautomatic segmentation in Volumetric measurements of maxillary sinus. (time frame: 1 year). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT04092699, which also lists 3 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 17 Sep 2019.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in