Aortic StenosisNCT04066634

Vivio AS (Aortic Stenosis) Detection Study

A study testing Vivio System in people with Aortic Stenosis, run by Ventric Health, LLC at 3 sites in United States.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record

Search all trials

Trial summary

Evaluate the sensitivity and specificity of the Vivio System when used as an aid in the identification of heart sounds associated with severe aortic stenosis. Read more about this study

Who is it for?
Ages 21 years and olderHealthy volunteers can take part
Conditions the study is for
Aortic Stenosis
What is being tested?
Vivio System
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
200 participants
Where
3 sitesUnited States
Study dates
2 Apr 2019to 29 Oct 2019
Phase
Interventional

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 21 years and older
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Who may be able to join

  • Adult subjects (21 years of age or older).
  • Referred for transthoracic echocardiography by physician/primary care provider/cardiologist.
  • Willing and able to participate in all study evaluations and allow access to medical testing and records.
  • Signed informed consent or have a legally authorized representative who provides informed consent on behalf of the subject.

Who cannot join

  • Acute coronary syndrome, cardiogenic shock or the need for inotropic/mechanical circulatory support.
  • Need for bedside echocardiogram (inpatient).
  • Prosthetic device previously implanted at aortic valve position.
  • Inability to palpate carotid pulse (e.g. due to severe obesity)
  • History of carotid sinus hypersensitivity (i.e. fainting in response to touching or positioning the neck).
  • History of carotid artery disease or treatment (e.g. unstable carotid plaques that might rupture upon massage or endarterectomy).
  • Open skin lesions at target site of electronic stethoscope/Vivio device examination.

Trial locations and contacts

3 sites in 1 country.

United States3 sites
  • Morristown Medical Center

    Morristown, New Jersey, 07960

  • Miriam Hospital

    Providence, Rhode Island, 02906

  • St. Francis Hospital

    Roslyn, New York, 11576

Other trials in United States

About this study

Official title: Assessment of the Vivio System as an Aid in the Identification of Heart Sounds Associated With Severe Aortic Stenosis

Evaluate the sensitivity and specificity of the Vivio System when used as an aid in the identification of heart sounds associated with severe aortic stenosis.

Read the detailed description

Prospective, non-randomized, multi-center study of adult subjects referred for echocardiography. Total of 200 enrolled subjects at 3 sites. Up to 10 roll-in subjects per site. Enrolled subjects will undergo: Vivio data capture, Eko stethoscope capture of heart sounds, Standard of care transthoracic echocardiogram (TTE). Vivio analysis will not be available to non-Avicena personnel. Recorded sounds from the FDA-approved Eko stethoscope will be presented to an independent expert physician review panel blinded to Vivio and TTE results, to compare diagnosis of severe AS using Eko (auscultation) vs. Vivio (algorithms).

Conditions
Aortic Stenosis
Being tested
Vivio System
Medical subject headings
Aortic Valve Stenosis

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Vivio SystemDevice

    Also called Electronic stethoscope

    The Vivio Analysis Software is an analysis software that assists in identifying suspected systolic murmurs associated with aortic stenosis. The Vivio Analysis Software is used with the Vivio System, a non-invasive device used for the detection and amplification of sounds from the heart and arteries.

Study groups in NCT04066634
Study groupRoleWhat they receive
Assist in DiagnosisExperimentalThe Vivio Analysis Software is an analysis software that assists in identifying suspected systolic murmurs associated with aortic stenosis. The Vivio Analysis Software is used with the Vivio System, a non-invasive device used for the detection and amplification of sounds from the heart and arteries.
Receives: Device: Vivio System

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Primary Endpoint - Sensitivity and specificity of detection of heart sounds associated with severe aortic stenosis by the Vivio System

    Sensitivity and specificity of detection of heart sounds associated with severe aortic stenosis by the Vivio System compared to the Expert Physician Panel (EPP).

    Measured: 48 Hours

Secondary outcomes (4)
  1. Secondary Endpoint 1 - Sensitivity and specificity relative to PCPP detection of heart sounds associated with severe aortic stenosis.

    Sensitivity and specificity relative to PCPP detection of heart sounds associated with severe aortic stenosis.

    Measured: 48 Hours

  2. Secondary Endpoint 2 - Correlation of Vivio results to transthoracic echocardiography assessment of aortic stenosis as determined by echocardiography.

    Correlation of Vivio results to transthoracic echocardiography assessment of aortic stenosis as determined by echocardiography.

    Measured: 48 Hours

  3. Secondary Endpoint 3 - Additional analysis of data to include Likelihood Ratios (LR), Positive Predictive Value (PPV), and Negative Predictive Value (NPV).

    Additional analysis of data to include Likelihood Ratios (LR), Positive Predictive Value (PPV), and Negative Predictive Value (NPV).

    Measured: 48 Hours

  4. Secondary Endpoint 4 - Assessment of type and degree of all heart sounds associated with aortic stenosis (mild/moderate/severe).

    Assessment of type and degree of all heart sounds associated with aortic stenosis (mild/moderate/severe). The heart sounds associated with severe aortic stenosis using a traditional electronic stethoscope include S1 (normal), S2 (single or paradoxically split) and a late peaking (mid to late systole) diamond shaped, grade 3 or higher murmur. The Vivio system can detect a single component of S2 (aortic) over the carotid but not the pulmonic component or splitting characteristics. It can also detect the nature and timing of the systolic murmur as transmitted through the vascular system to the carotid. The heart sounds associated with severe aortic stenosis include S1 (normal), presence or absence of S2. Less severe aortic stenosis is characterized by an early to mid-peaking diamond shape murmur with a soft but present aortic component of S2.

    Measured: 48 Hours

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted26 Aug 2019
  2. Study start2 Apr 2019
  3. Primary completion29 Oct 2019
  4. Study completion29 Oct 2019

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
200 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04066634
Sponsor's protocol ID
VS-001-AS
Status last verified
Jul 2021
First submitted
25 Jul 2019
Last updated
2 Aug 2021
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
Yes

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in