AzTrials
AzTrials

AmetropiaNCT03556579

The Effects of Contact Lenses With Experimental Dye on Visual Function

A study testing senofilcon A with new UV blocker and senofilcon A in people with Ametropia, run by Johnson & Johnson Vision Care, Inc. at 1 site in United States.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

This is a single-site, two-visit, contralateral, non-dispensing, randomized, controlled and subject-masked study to measure potential benefits of the new UV blocker. Read more about this study

Who is it for?
Ages 18 to 65 yearsHealthy volunteers can take part
Conditions the study is for
Ametropia
What is being tested?
senofilcon A with new UV blocker and senofilcon A
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
62 participants
Where
1 siteUnited States
Study dates
15 May 2018to 20 Sep 2018
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 65 years
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Who may be able to join

  • Potential subjects must satisfy all of the following criteria to be enrolled in the study:
  • The subject must read, understand, and sign the STATEMENT OF INFORMED CONSENT and receive a fully executed copy of the form.
  • Appear able and willing to adhere to the instructions set forth in this clinical protocol
  • Between 18 and 65 (inclusive) years of age at the time of screening.
  • Be a current spherical soft silicone hydrogel contact lens wearer in both eyes with a minimum of 6 hours/day and 5 days/week wear time over the last 30 days by self-report.
  • The subject's vertex-corrected spherical equivalent distance refraction must be in the range of -1.00 through -4.50 D in each eye.
  • The subject has a best corrected visual acuity of 20/25 or better in each eye.

Who cannot join

  • Currently pregnant or breastfeeding.
  • Any ocular or systemic allergies or diseases that may interfere with contact lens wear.
  • Any autoimmune disease or use of medication, which may interfere with contact lens wear. Habitual medications used by successful soft contact lens wearers are considered acceptable.
  • Entropion, ectropion, extrusions, chalazia, recurrent styes, glaucoma, history of recurrent corneal erosions, or aphakia.
  • Any previous, or planned, ocular or interocular surgery (e.g., radial keratotomy, PRK, LASIK, etc.).
  • Any corneal distortion resulting from previous hard or rigid gas permeable contact lens wear.
Show all 13Show fewer
  • Multifocal, toric or extended wear contact lens correction.
  • Participation in any contact lens or lens care product clinical trial within 14 days prior to study enrollment.
  • History of binocular vision abnormality or strabismus.
  • Any infectious disease (e.g., hepatitis, tuberculosis) or contagious immunosuppressive diseases (e.g., HIV) by self-report.
  • Employee or immediate family member of an employee of clinical site (e.g., Investigator, Coordinator, Technician).
  • Any ocular infection.
  • Any grade 3 or greater slit lamp findings (e.g., edema, corneal neovascularization, corneal staining, tarsal abnormalities, conjunctival injection) on the FDA classification scale, any previous history or signs of a contact lens-related corneal inflammatory event (e.g., past peripheral ulcer or round peripheral scar), or any other ocular abnormality that may contraindicate contact lens wear.

Trial locations and contacts

1 site in 1 country.

United States1 site
  • Georgia Center for Sight

    Statesboro, Georgia, 30642

Other trials in United States

About this study

This is a single-site, two-visit, contralateral, non-dispensing, randomized, controlled and subject-masked study to measure potential benefits of the new UV blocker.

Conditions
Ametropia
Being tested
senofilcon A with new UV blocker, senofilcon A
Medical subject headings
Refractive Errors

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • senofilcon A with new UV blockerDevice

    Test Lens

  • senofilcon ADevice

    Control Lens

Study groups in NCT03556579
Study groupRoleWhat they receive
Test/ControlExperimentalFor Visit 1, subjects will be randomly assigned to 1 of 2 contralateral lens sequences (Right: Test, Left: Control) OR (Right: Control, Left: Test). Then for visit 2, subjects will be randomly assigned to the same 1 of 2 contralateral lens sequences again.
Receives: Device: senofilcon A with new UV blocker; Device: senofilcon A
Control/TestExperimentalFor Visit 1, subjects will be randomly assigned to 1 of 2 contralateral lens sequences (Right: Test, Left: Control) OR (Right: Control, Left: Test). Then for visit 2, subjects will be randomly assigned to the same 1 of 2 contralateral lens sequences again.
Receives: Device: senofilcon A with new UV blocker; Device: senofilcon A

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Two-Point Light Spread Function

    The two-point light spread function was assessed at visit 2 for each subject eye under two conditions with a distance filter and without a distance filter. Measurements for this metric were taken twice, with the presence of an additional UV/HEV light source and without this additional light source (the same study lenses were used for both measurements). Two-point light spread function is defined that the as the minimum distance (mm) that two points of light are completely distinct. Measurements for this metric are positive. Smaller distances indicate better lens performance. The average distance for each lens type and light source combination was reported across age groups.

    Measured: Between 5 minutes and 3 hours Post Lens Insertion, at Visit 2

  2. Halos

    The appearance of Halos was assessed at visit 2 for each subject eye. Measurements for this metric were taken twice, with the presence of an additional UV/HEV light source and without this additional light source (the same study lenses were used for both measurements). Halos were quantified as the diameter (mm) of the outer edges of the Halo. Measurements for this metric are positive. Smaller diameter indicates better lens performance. The average diameter (mm) for each lens type and light source combination was reported across age groups.

    Measured: Between 5 minutes and 3 hours Post Lens Insertion, at Visit 2

  3. Starburts

    The appearance of starbursts was assessed at visit 2 for each subject eye. Measurements for this metric were taken twice, with the presence of an additional UV/HEV light source and without this additional light source (the same study lenses were used for both measurements). Starbursts are defined as the diameter (mm) of the light's lateral spread. Measurements for this metric are positive. Smaller diameter indicates better lens performance. The average diameter (mm) for each lens type and light source combination was reported across age groups.

    Measured: Between 5 minutes and 3 hours Post Lens Insertion, at Visit 2

Secondary outcomes (4)
  1. Glare Disability Threshold

    The Glare disability threshold was assessed for each eye at visit 1. The study lenses in this visit were assessed without the additional light sourced used at visit 2. Subjects were exposed to a target stimulus for 2 seconds; before the measurement was taken the annulus was set to a level below that which would cause the target stimulus to be veiled. The experimenter would then adjust the intensity of the annulus until subjects could no longer see the target stimulus. Subjects would indicate this by pressing a buzzer. Glare disability thresholds take on positive values, where higher values indicate better lens performance. The average glare disability level (change in log relative energy) for each lens type was reported across age groups.

    Measured: Between 5 minutes and 3 hours Post Lens Insertion, at Visit 1

  2. Photostress Recovery Time

    Photostress Recovery (PR) Time (seconds) was assessed for each eye at visit 1. The study lenses in this visit were assessed without the additional light sourced used at visit 2. Subjects are exposed to a target, once the target was able to be comfortable viewed by the subject, a bright bleaching light covered it. As the afterimage fades, participants will gradually be able to re-gain sight of the target. PR time will be recorded as the time it takes following exposure to the bleaching light to regain sight of the target. PR Times are positive values where smaller times indicate better lens performance. The average PR Time (seconds) for each lens type was reported across age groups.

    Measured: Between 5 minutes and 3 hours Post Lens Insertion, at Visit 1

  3. Glare Discomfort

    The Glare discomfort (change in palpebral fissure height) was assessed for each eye at visit 1. The study lenses in this visit were assessed without the additional light sourced used at visit 2. Glare discomfort can take on negative and positive values, where smaller values indicate better lens performance. The average glare discomfort (change in palpebral fissure height) for each lens type was reported across age groups.

    Measured: Between 5 minutes and 3 hours Post Lens Insertion, at Visit 1

  4. Heterochromatic Contrast Threshold

    Heterochromatic Contrast Threshold was assessed for each eye at visit 1. The study lenses in this visit were assessed without the additional light sourced used at visit 2. Heterochromatic contrast thresholds are measured as thresholds to a variable wavelength central target presented on a short-wave (460nm) sky-light background. Thresholds are positive values, where higher values indicate better lens performance. The average threshold each lens type was reported across age groups.

    Measured: Between 5 minutes and 3 hours Post Lens Insertion, at Visit 1

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted14 Jun 2018
  2. Study start15 May 2018
  3. Primary completion20 Sep 2018
  4. Study completion20 Sep 2018

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Crossover
Masking
Single blind
Who is masked
Participant
Enrolment
62 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03556579
Sponsor's protocol ID
CR-6100
Status last verified
Oct 2019
First submitted
31 May 2018
Last updated
18 Nov 2019
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
Yes

Questions about this trial

What is this clinical trial studying?

A study testing senofilcon A with new UV blocker and senofilcon A in people with Ametropia, run by Johnson & Johnson Vision Care, Inc. at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 7 inclusion and 13 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 18 Nov 2019. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 18 Nov 2019). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Two-Point Light Spread Function (time frame: Between 5 minutes and 3 hours Post Lens Insertion, at Visit 2). The study lists 3 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 18 Nov 2019.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in