Enhanced Lung Protective Ventilation With ECCO2R During ARDS

A study testing Low flow Extracorporeal CO2 removal in people with ARDS, Human and Ventilator-Induced Lung Injury, run by Hôpital Européen Marseille at 1 site in France.

Terminated

Stopped early. The study ended before it was planned to and will not resume.

Official record
Search all trials

Trial summary

Acute Respiratory Distress Syndrome (ARDS) is associated with a mortality rate of 30 - 45 % and required invasive mechanical ventilation (MV) in almost 85 % of patients[1]. During controlled MV, driving pressure (i.e., the difference between end-inspiratory and end-expiratory airway pressure) depends of both tidal… Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
ARDS, Human, Ventilator-Induced Lung Injury
What is being tested?
Low flow Extracorporeal CO2 removal
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
3 participants
Where
1 siteFrance
Study dates
23 May 2018to 5 Dec 2023
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • ARDS moderate or severe (Berlin criteria)
  • Onset < 48 h
  • Driving pressure ≥ 11 cmH2O

Who cannot join

  • Lack of consent or social protection
  • Chronic respiratory failure (requiring Oxygen or NIPPV)
  • Severe hypoxemia: PaO2/FIO2 < 80 with PEEP ≥ 18 cmH2O AND FIO2= 1
  • Acute Renal Failure requiring RRT
  • DNR order or death expected within the next 72 hours
  • Planned surgery or transport out-of-ICU expected within the next 72 hours
Show all 9Show fewer
  • Heparin allergy
  • Contraindication to jugular vein catheterization
  • Intracranial Hypertension

Trial locations and contacts

1 site in 1 country.

France1 site
  • Service de REANIMATION, HOPITAL EUROPEEN MARSEILLE

    Marseille

Other trials in France

About this study

Official title: Enhanced Lung Protective Ventilation With Extracorporeal CO2 Removal During Acute Respiratory Distress Syndrome

Acute Respiratory Distress Syndrome (ARDS) is associated with a mortality rate of 30 - 45 % and required invasive mechanical ventilation (MV) in almost 85 % of patients[1]. During controlled MV, driving pressure (i.e., the difference between end-inspiratory and end-expiratory airway pressure) depends of both tidal volume and respiratory system compliance. Either excessive tidal volume or reduced lung aeration may increase the driving pressure. ARDS patients receiving tidal volume of 6 ml/kg predicted body weight (PBW) and having a day-1 driving pressure ≥ 14 cmH2O have an increased risk of death in the hospital[2]. Seemly, in the LUNG SAFE observational cohort, ARDS patients having a day-1 driving pressure < 11 cmH2O had the lowest risk of death in the hospital[1]. Hence, driving pressure acts as a major contributor of mortality in ARDS, and probably reflects excessive regional lung distension resulting in pro-inflammatory and fibrotic biological processes. Whether decreasing the driving pressure by an intervention change mortality remains an hypothesis; but one of means is to decrease the tidal volume from 6 to 4 ml/ kg predicted body weight (PBW). However, this strategy promotes hypercarbia, at constant respiratory rate, by decreasing the alveolar ventilation. In this setting, implementing an extracorporeal CO2 removal (ECCO2R) therapy prevents from hypercarbia. A number of low-flow ECCO2R devices are now available and some of those use renal replacement therapy (RRT) platform. The investigators previously reported that combining a membrane oxygenator (0.65 m²) within a hemofiltration circuit provides efficacious low flow ECCO2R and blood purification in patients presenting with both ARDS and Acute Kidney injury[3].

This study aims to investigate the efficacy of an original ECCO2R system combining a 0.67 m² membrane oxygenator (Lilliput 2, SORIN) inserted within a specific circuit (HP-X, BAXTER) and mounted on a RRT monitor (PrismafleX, BAXTER). Such a therapy only aims to provide decarboxylation but not blood purification and has the huge advantage to be potentially implemented in most ICUs without requiring a specific ECCO2R device. The study will consist in three periods:

Read more
  • The first period will address the efficacy of this original ECCO2R system at tidal volume of 6 and 4 ml/kg PBW using an off-on-off design.
  • The second part will investigate the effect of varying the sweep gas flow (0-2-4-6-8-10 l/min) and the mixture of the sweep gas (Air/O2) on the CO2 removal rate.
  • The third part will compare three ventilatory strategies applied in a crossover design:
  1. Minimal distension: Tidal volume 4 ml/kg PBW and positive end-expiratory pressure (PEEP) based on the ARDSNet PEEP/FiO2 table (ARMA).
  2. Maximal recruitment: 4 ml/kg PBW and PEEP adjusted to maintain a plateau pressure between 23 - 25 cmH2O.
  3. Standard: Tidal volume 6 ml/kg and PEEP based on the ARDSNet PEEP/FiO2 table (ARMA).
Being tested
Low flow Extracorporeal CO2 removal
Medical subject headings
Respiratory Distress Syndrome, Ventilator-Induced Lung Injury

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Low flow Extracorporeal CO2 removalDevice

    Low flow Extracorporeal CO2 removal using a 0.67 m² membrane oxygenator (Lilliput 2) and a specific circuit (HP-X) mounted on a RRT monitor (PrismafleX)

Study groups in NCT03525691
Study groupRoleWhat they receive
Minimal distensionExperimentalTidal volume 4 ml/kg PBW and positive end-expiratory pressure (PEEP) based on the ARDSNet PEEP/FiO2 table (ARMA) + ECCO2R (sweep gas = 8 L/min, blood flow = 400 mL/min)
Receives: Device: Low flow Extracorporeal CO2 removal
Maximal recruitmentExperimentalTidal volume 4 ml/kg PBW and PEEP adjusted to maintain a plateau pressure between 23 - 25 cmH2O + ECCO2R (sweep gas = 8 L/min, blood flow = 400 mL/min)
Receives: Device: Low flow Extracorporeal CO2 removal
StandardActive comparatorTidal volume 6 ml/kg PBW and positive end-expiratory pressure (PEEP) based on the ARDSNet PEEP/FiO2 table (ARMA) without ECCO2R (no sweep gas flow, blood flow = 400 mL/min)
Receives: Device: Low flow Extracorporeal CO2 removal

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Change in PaCO2

    20 % decrease in PaCO2 after initiation of ECCO2R at tidal volume of 4 ml/kg PBW (as compared to 4 ml/kg without ECCO2R)

    Measured: 15 minutes after initiation of ECCO2R at tidal volume of 4 ml/kg PBW.

Secondary outcomes (9)
  1. PaCO2

    Arterial blood gas analyser (RAPIDPoint 500)

    Measured: each 15 minutes up to the third hour (Part I and II of the study). In the third part, measurement at baseline and at 1 hour and at 22 hours into each arm.

  2. CO2 removal rate

    Using measurements from both the blood side and the gas side (two methods)

    Measured: each 15 minutes up to the third hour (Part I and II of the study). In the third part, measurement at baseline and at 1 hour and at 22 hours into each arm.

  3. Transpulmonary pressure and work of breathing

    Using an oesophageal balloon catheter (NutriVent catheter) and a dedicated monitor (FluxMed, MBMed)

    Measured: each 15 minutes up to the third hour (Part I and II of the study). In the third part, measurement at baseline and at 1 hour and at 22 hours into each arm.

  4. Regional tidal ventilation

    Using an Electrical Impedance Tomography device (BB², Swisstom)

    Measured: each 15 minutes up to the third hour (Part I and II of the study). In the third part, measurement at baseline and at 1 hour and at 22 hours into each arm.

  5. End-expiratory Lung Volume

    Using the nitrogen wash-in wash-out method (Engstrom GE)

    Measured: each 15 minutes up to the third hour (Part I and II of the study). In the third part, measurement at baseline and at 1 hour and at 22 hours into each arm.

  6. Plasma Cytokines

    Using Elisa custom kit (Qiagen) from plasma samples

    Measured: Only in the third part, measurement at baseline and at 1 hour and at 22 hours into each arm.

  7. Pulmonary Cytokines

    Using Elisa custom kit (Qiagen) from BAL samples

    Measured: Only in the third part, measurement at baseline and at 1 hour and at 22 hours into each arm.

  8. Type III Procollagen

    Using both RIA and Elisa methods from plasma and BAL samples

    Measured: Only in the third part, measurement at baseline and at 1 hour and at 22 hours into each arm.

  9. Pulmonary Inflammatory and Fibrotic pathway

    Using mRNA custom kit RT-PCR analysis (Qiagen) from BAL samples

    Measured: Only in the third part, measurement at baseline and at 1 hour and at 22 hours into each arm.

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted16 May 2018
  2. Study start23 May 2018
  3. Primary completion5 Dec 2023
  4. Study completion5 Dec 2023

Why it stopped: insufficient enrollment

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Supportive care
Allocation
Randomised
Intervention model
Crossover
Masking
None (open label)
Enrolment
3 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03525691
Sponsor's protocol ID
2017-A03647-46
Acronym
PROVE
Status last verified
Dec 2023
First submitted
3 May 2018
Last updated
12 Dec 2023
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Bellani G, Laffey JG, Pham T, Fan E, Brochard L, Esteban A, Gattinoni L, van Haren F, Larsson A, McAuley DF, Ranieri M, Rubenfeld G, Thompson BT, Wrigge H, Slutsky AS, Pesenti A; LUNG SAFE Investigators; ESICM Trials Group. Epidemiology, Patterns of Care, and Mortality for Patients With Acute Respiratory Distress Syndrome in Intensive Care Units in 50 Countries. JAMA. 2016 Feb 23;315(8):788-800. doi: 10.1001/jama.2016.0291.

    PubMed 26903337
  • Amato MB, Meade MO, Slutsky AS, Brochard L, Costa EL, Schoenfeld DA, Stewart TE, Briel M, Talmor D, Mercat A, Richard JC, Carvalho CR, Brower RG. Driving pressure and survival in the acute respiratory distress syndrome. N Engl J Med. 2015 Feb 19;372(8):747-55. doi: 10.1056/NEJMsa1410639.

    PubMed 25693014
  • Allardet-Servent J, Castanier M, Signouret T, Soundaravelou R, Lepidi A, Seghboyan JM. Safety and Efficacy of Combined Extracorporeal CO2 Removal and Renal Replacement Therapy in Patients With Acute Respiratory Distress Syndrome and Acute Kidney Injury: The Pulmonary and Renal Support in Acute Respiratory Distress Syndrome Study. Crit Care Med. 2015 Dec;43(12):2570-81. doi: 10.1097/CCM.0000000000001296.

    PubMed 26488219

Questions about this trial

What is this clinical trial studying?

A study testing Low flow Extracorporeal CO2 removal in people with ARDS, Human and Ventilator-Induced Lung Injury, run by Hôpital Européen Marseille at 1 site in France.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 9 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: stopped early, as of the sponsor's last update on 12 Dec 2023. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in France. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study was stopped early (reason given: insufficient enrollment). Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Change in PaCO2 (time frame: 15 minutes after initiation of ECCO2R at tidal volume of 4 ml/kg PBW.). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT03525691, which also lists 3 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 12 Dec 2023; AzTrials last refreshed its copy on 26 Oct 2026.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in