Type1diabetesPhase 1NCT03424044
Three Way Crossover Closed Loop Study With Xeris Glucagon
A Phase 1 study testing XeriSol glucagon in people with Type1diabetes, run by Oregon Health and Science University at 1 site in United States.
Trial summary
Closed-loop systems are an emerging technology that automate hormone delivery. They are quickly paving the way to revolutionize the treatment of type 1 diabetes. Several categories have emerged: dual-hormone (insulin and glucagon) closed-loop systems and closed-loop systems with insulin only, one variety of which is… Read more about this study
- Who is it for?
- Ages 21 to 50 years
- Conditions the study is for
- Type1diabetes
- What is being tested?
- XeriSol glucagon
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 23 participants
- Where
- 1 siteUnited States
- Study dates
- 29 Mar 2018to 17 May 2019
- Phase
- Phase 1
- Are there results?
- Yes, posted in the registrySummary in the doctors' view
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 21 to 50 years
- All sexes
- No healthy volunteers
- Adult
Who may be able to join
- Diagnosis of type 1 diabetes mellitus for at least 1 year.
- Male or female subjects 21-50 years of age.
- Physically willing and able to perform 45 min of exercise.
- Current use of an insulin pump.
- Lives with another person age 18 or older who will be present while subject exercises at home and that can attend the training on using the system.
- Lives within 40 miles of OHSU main campus.
Show all 11Show fewer
- HbA1c <= 10% at screening.
- Total daily insulin requirement is less than 139 units/day.
- Current use of a phone or other device so can be contacted by study staff off-campus.
- Willingness to follow all study procedures, including attending all clinic visits.
- Willingness to sign informed consent and HIPAA documents.
Who cannot join
- Female of childbearing potential who is pregnant or intending to become pregnant or breast-feeding, or is not using adequate contraceptive methods. Acceptable contraception includes birth control pill/patch/vaginal ring, Depo-Provera, Norplant, an IUD, the double barrier method (the woman uses a diaphragm and spermicide and the man uses a condom), or abstinence.
- Any cardiovascular disease, defined as a clinically significant EKG abnormality at the time of screening or any history of: stroke, heart failure, myocardial infarction, angina pectoris, or coronary arterial bypass graft or angioplasty. Diagnosis of 2nd and 3rd degree heart block or any non-physiological arrhythmia judged by the investigator to be exclusionary.
- Renal insufficiency (GFR < 60 ml/min, using the MDRD equation as report by the OHSU laboratory).
- Liver failure, cirrhosis, or any other liver disease that compromises liver function as determined by the investigator.
- Hematocrit of less than 36% for men, less than 32% for women.
- Hypertensive subjects with systolic blood pressure >= 160 mm Hg or diastolic blood pressure >= 100 mm Hg despite treatment or who have treatment-refractory hypertension (e.g. requiring four or more medications).
Show all 32Show fewer
- History of severe hypoglycemia during the past 12 months prior to screening visit or hypoglycemia unawareness as judged by the investigator. Subjects will complete a hypoglycemia awareness questionnaire. Subjects will be excluded for four or more R responses.
- Adrenal insufficiency.
- Any active infection.
- Known or suspected abuse of alcohol, narcotics, or illicit drugs.
- Seizure disorder.
- Active foot ulceration.
- Severe peripheral arterial disease characterized by ischemic rest pain or severe claudication.
- Major surgical operation within 30 days prior to screening.
- Use of an investigational drug within 30 days prior to screening.
- Chronic usage of any immunosuppressive medication (such as cyclosporine, azathioprine, sirolimus, or tacrolimus).
- Bleeding disorder, treatment with warfarin, or platelet count below 50,000.
- Allergy to aspart insulin.
- Allergy to glucagon.
- Need for uninterrupted treatment of acetaminophen.
- Current administration of oral or parenteral corticosteroids.
- Any life threatening disease, including malignant neoplasms and medical history or malignant neoplasms within the past 5 years prior to screening (except basal and squamous cell skin cancer).
- Beta blockers or non-dihydropyridine calcium channel blockers.
- Current use of any medication intended to lower glucose other than insulin (e.g. use of liraglutide).
- Diagnosis of pheochromocytoma, insulinoma, or glucagonoma, personal or family history of multiple endocrine neoplasmia (MEN) 2A, MEN 2B, neurofibromatosis or von Hippel-Lindau disease.
- History of severe hypersensitivity to milk protein.
- Current use of any medication with strong anticholinergic properties, such as antihistamines, sleep aids, and antidiarrheal medications.
- Current use of indomethacin.
- Conditions that may results in low levels of releasable glucose in the liver and an inadequate reversal of hypoglycemia by glucagon such as prolonged fasting, starvation or chronic hypoglycemia as determined by the investigator.
- A positive response to any of the questions from the Physical Activity Readiness Questionnaire with one exception: subject will not be excluded if he/she takes a single blood pressure medication that doesn't impact heart rate and blood pressure is controlled on the medication (blood pressure is less than 140/90 mmHg).
- Any chest discomfort with physical activity, including pain or pressure, or other types of discomfort.
- Any clinically significant disease or disorder which in the opinion of the investigator may jeopardize the subject's safety or compliance with the protocol.
Trial locations and contacts
1 site in 1 country.
United States1 site
Oregon Health and Science University
Portland, Oregon, 97239
About this study
Official title: A Randomized, Three-way, Cross-over Study to Assess the Efficacy of a Dual-hormone Closed-loop System With XeriSol™ Glucagon vs Closed-loop System With Insulin Only vs a Predictive Low Glucose Suspend System
Closed-loop systems are an emerging technology that automate hormone delivery. They are quickly paving the way to revolutionize the treatment of type 1 diabetes. Several categories have emerged: dual-hormone (insulin and glucagon) closed-loop systems and closed-loop systems with insulin only, one variety of which is the low glucose suspend safety feature now available from Medtronic (MiniMed640G with SmartGuard). The study described within this protocol is designed to test the efficacy of a new closed-loop algorithm for managing blood glucose in people with type 1 diabetes before and after exercise. The new algorithm will have 3 modes: a single hormone insulin only mode, a dual-hormone insulin and glucagon mode and an insulin only mode with predictive low glucose suspend, all with an exercise detection algorithm. The purpose of this study is to determine whether a dual hormone AP using a stable investigational glucagon with an exercise detection algorithm outperforms both single hormone AP and a low glucose suspend algorithm.
Read the detailed description
Subjects will undergo three approximately 76 hour studies. During each of these intervention visits, subjects will wear an Omnipod to deliver insulin and a Dexcom G5 CGM to measure glucose. In the dual-hormone closed-loop study, participants will wear a second Omnipod filled with XeriSol™ glucagon. The first day of intervention visit will be a 12 hour inpatient visit with the subsequent time spent as an outpatient. The subject will come back to the research center on Day 4 in the morning to remove all devices. The blood glucose control system is called the Artificial Pancreas Controller (APC). During one of the studies, glucose will be controlled using the dual hormone mode. During another study, glucose will be controlled using the single hormone mode. The single and dual hormone modes of the APC controller determine insulin only and insulin with glucagon delivery rates based on proportional and derivative error and contain an exercise detection component. During the other study, glucose will be controlled using a predictive low glucose suspend (PLGS) mode. In the PLGS mode, the APC will be programmed with the subject's basal profile(s) which will be transmitted to the Omnipod Personal Diabetes Manager (PDM) and allow for boluses to be inputted by the subjects for meals and corrections using their typical carb ratios and correction factors. However, this system will have a safety feature to suspend insulin delivery when sensor glucose is predicted to go below a threshold. Treatment order will be randomized.
Subjects will arrive at the clinic at approximately 7 or 8am for the inpatient visits. Subjects will eat breakfast and lunch at approximately 8:30am, noon and 6pm respectively. The dinner meal will be consumed while the subject is at home. Subjects will exercise on a treadmill for 45 minutes. Subjects will be discharged 9 hours after admission. The subject will then go home for the remainder of the study visit. Studies will be remotely monitored. Subjects will return to OHSU on Day 4 for removal of all devices.
During each study, the subject will wear one subcutaneous DexcomTM G5 continuous glucose monitoring (CGM) system. The CGM system will provide sensed glucose data every 5 minutes. The accuracy of the sensed data will be obtained by reference measurements of capillary blood glucose. Sensed glucose data will be wirelessly transmitted via Bluetooth Low Energy (BTLE) from the Dexcom G5 transmitter to the Nexus 5 master controller every five minutes. The controller for all 3 modes is a Google Nexus 5 phone. The smart phone will wirelessly communicate via BTLE to an Omnipod through a PDM (Insulet Corp. ) for automated insulin delivery or in the case of dual-hormone AP, one used for automated insulin delivery and one for automated glucagon delivery.
A physician or nurse practitioner will be present for study start-up, will be on campus for exercise on Day 1 and will be immediately available on call at all other times.
- Conditions
- Type1diabetes
- Being tested
- Artificial Pancreas Controller in Dual Hormone Mode, Artificial Pancreas Controller in Single Hormone Mode, Artificial Pancreas Controller in Predictive Low Glucose Suspend Mode, XeriSol glucagon
- Keywords
- glucagon, closed-loop, Omnipod, exercise
- Medical subject headings
- Motor Activity
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Artificial Pancreas Controller in Dual Hormone ModeDevice
The artificial pancreas controller contains an algorithm for managing blood glucose in people with type 1 diabetes which includes an exercise detection component. The algorithm has 3 modes: a single hormone closed-loop insulin only mode, a dual-hormone closed-loop insulin and glucagon mode and an insulin only mode with predictive low glucose suspend. The Closed-loop Artificial Pancreas Controller includes insulin and glucagon delivery algorithm implemented on a smart phone, utilizing sensor glucose values from a Dexcom G5 sensor and sending delivery commands to two Omnipod insulin pumps, one filled with insulin and one with glucagon.
Artificial Pancreas Controller in Single Hormone ModeDevice
The artificial pancreas controller contains an algorithm for managing blood glucose in people with type 1 diabetes which includes an exercise detection component. The new algorithm will have 3 modes: a single hormone closed-loop insulin only mode, a dual-hormone closed-loop insulin and glucagon mode and an insulin only mode with predictive low glucose suspend. The Closed-loop Artificial Pancreas Controller includes insulin delivery algorithm implemented on a smart phone, utilizing sensor glucose values from a Dexcom G5 sensor and sending delivery commands to one Omnipod pump filled with insulin.
Artificial Pancreas Controller in Predictive Low Glucose Suspend ModeDevice
The artificial pancreas controller contains an algorithm for managing blood glucose in people with type 1 diabetes which includes an exercise detection component. The new algorithm will have 3 modes: a single hormone closed-loop insulin only mode, a dual-hormone closed-loop insulin and glucagon mode and an insulin only mode with predictive low glucose suspend. The Closed-loop Artificial Pancreas Controller includes insulin delivery algorithm implemented on a smart phone, utilizing sensor glucose values from a Dexcom G5 sensor and sending delivery commands to one Omnipod insulin pump filled with insulin.
XeriSol glucagonDrug
XeriSol glucagon is an investigational drug that is a stable, soluble liquid glucagon formulation that can be injected or administered through an insulin pump. XeriSol glucagon will be used to fill the Omnipod to deliver glucagon for the Artificial Pancreas Controller in Dual Hormone mode.
| Study group | Role | What they receive |
|---|---|---|
| Dual Hormone Closed-loop Arm | Experimental | Subjects will undergo a 76 hour study with 9 hours inpatient and 67 hours outpatient using the closed-loop artificial pancreas controller in dual hormone mode and XeriSol glucagon to manage blood sugar that includes an exercise detection component that includes a reduction in insulin delivery and an increase in glucagon delivery upon detection. Receives: Device: Artificial Pancreas Controller in Dual Hormone Mode; Drug: XeriSol glucagon |
| Single Hormone Closed-loop Arm | Experimental | Subjects will undergo a 76 hour study with 9 hours inpatient and 67 hours outpatient using the closed-loop artificial pancreas controller in single hormone mode to manage blood sugar that includes an exercise detection component that includes a reduction in insulin delivery upon detection. Receives: Device: Artificial Pancreas Controller in Single Hormone Mode |
| Predictive Low Glucose Suspend Arm | Experimental | Subjects will undergo a 76 hour study with 9 hours inpatient and 67 hours outpatient using the closed-loop artificial pancreas controller in predictive low glucose suspend mode. The system will run through the closed-loop system but will utilize the patient's optimized basal rates, correction factors and carb ratios as they would normally run on their own insulin pump. But the mode will have the additional safety net of the pump suspending insulin when it predicts a hypoglycemic event. Receives: Device: Artificial Pancreas Controller in Predictive Low Glucose Suspend Mode |
What is being measured
The primary outcome is the main question the study is designed to answer.
Percent of Time With Sensed Glucose < 70 mg/dl
Assess the percent of time that the Dexcom G5 or G6 reported sensor glucose values less than 70 mg/dl using Dexcom sensor across all three arms.
Measured: 4 hours post exercise on Day 1
Secondary outcomes (6)
Percent of Time With Sensed Glucose Between 70-180 mg/dl
Assess the percent of time that the Dexcom G5 or G6 reported sensor glucose values between 70-180 mg/dl using Dexcom sensor across all three arms.
Measured: entire 76 hour study
Number of Carbohydrate Treatments
Assess the number of rescue carbohydrate treatments across all three arms per day.
Measured: 24 hours
Percent of Time With Sensed Glucose < 54 mg/dl
Assess the percent of time that the Dexcom G5 or G6 reported sensor glucose values less than 54 mg/dl using Dexcom sensor across all three arms.
Measured: entire 76 hour study
Percent of Time With Sensed Glucose > 180 mg/dl
Assess the percent of time that the Dexcom G5 or G6 reported sensor glucose values greater than 180 mg/dl using Dexcom sensor across all three arms.
Measured: entire 76 hour study
Mean Amount of Insulin Delivered in One Day
Assess the mean amount of insulin delivered in units/kg as documented through the artificial pancreas controller across all three arms.
Measured: 24 hours
Mean Amount of Glucagon Delivered in One Day
Assess the mean amount of XeriSol glucagon delivered in mcg/kg as documented through the artificial pancreas controller in dual hormone arm.
Measured: 24 hours
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted6 Feb 2018
- Study start29 Mar 2018
- Primary completion17 May 2019
- Study completion17 May 2019
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Posted resultsParticipant flow, outcome measures and adverse events reported by the sponsor.
- Publications (1)Papers the sponsor has linked to this study.
- Other trials for Type1diabetesStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase 1
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Crossover
- Masking
- None (open label)
- Enrolment
- 23 participants (actual)
Sponsor and investigators
- Lead sponsor
- Oregon Health and Science University
- Sponsor type
- University, hospital or other
- Collaborators
- Xeris Pharmaceuticals
- Responsible party
- Principal investigator, Jessica Castle, Oregon Health and Science University
- Investigators
- Jessica Castle, MD, Principal investigator, Oregon Health and Science University
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT03424044
- Sponsor's protocol ID
- 17225
- Status last verified
- May 2020
- First submitted
- 31 Jan 2018
- Last updated
- 27 May 2020
- Results posted
- Yes, on ClinicalTrials.gov
- Data monitoring committee
- No
- FDA-regulated drug
- Yes
- FDA-regulated device
- Yes
Publications
Wilson LM, Jacobs PG, Ramsey KL, Resalat N, Reddy R, Branigan D, Leitschuh J, Gabo V, Guillot F, Senf B, El Youssef J, Steineck IIK, Tyler NS, Castle JR. Dual-Hormone Closed-Loop System Using a Liquid Stable Glucagon Formulation Versus Insulin-Only Closed-Loop System Compared With a Predictive Low Glucose Suspend System: An Open-Label, Outpatient, Single-Center, Crossover, Randomized Controlled Trial. Diabetes Care. 2020 Nov;43(11):2721-2729. doi: 10.2337/dc19-2267. Epub 2020 Sep 9.
PubMed 32907828
Study at a glance
From the registry record, last updated by the sponsor on 27 May 2020. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- A Randomized, Three-way, Cross-over Study to Assess the Efficacy of a Dual-hormone Closed-loop System With XeriSol™ Glucagon vs Closed-loop System With Insulin Only vs a Predictive Low Glucose Suspend System
- ClinicalTrials.gov ID
- NCT03424044
- Acronym / sponsor ID
- 17225
- Conditions
- Type1diabetes
- Keywords
- glucagon, closed-loop, Omnipod, exercise
- Phase
- Phase 1
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 23 participants (actual)
- Lead sponsor
- Oregon Health and Science UniversityUniversity, hospital or other
- Collaborators
- Xeris Pharmaceuticals
- Study start
- 29 Mar 2018 (actual)
- Primary completion
- 17 May 2019 (actual)
- Study completion
- 17 May 2019 (actual)
- First posted
- 6 Feb 2018 (actual)
- Results
- Posted 13 May 2020
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Closed-loop systems are an emerging technology that automate hormone delivery. They are quickly paving the way to revolutionize the treatment of type 1 diabetes. Several categories have emerged: dual-hormone (insulin and glucagon) closed-loop systems and closed-loop systems with insulin only, one variety of which is the low glucose suspend safety feature now available from Medtronic (MiniMed640G with SmartGuard). The study described within this protocol is designed to test the efficacy of a new closed-loop algorithm for managing blood glucose in people with type 1 diabetes before and after exercise. The new algorithm will have 3 modes: a single hormone insulin only mode, a dual-hormone insulin and glucagon mode and an insulin only mode with predictive low glucose suspend, all with an exercise detection algorithm. The purpose of this study is to determine whether a dual hormone AP using a stable investigational glucagon with an exercise detection algorithm outperforms both single hormone AP and a low glucose suspend algorithm.
Detailed description
Subjects will undergo three approximately 76 hour studies. During each of these intervention visits, subjects will wear an Omnipod to deliver insulin and a Dexcom G5 CGM to measure glucose. In the dual-hormone closed-loop study, participants will wear a second Omnipod filled with XeriSol™ glucagon. The first day of intervention visit will be a 12 hour inpatient visit with the subsequent time spent as an outpatient. The subject will come back to the research center on Day 4 in the morning to remove all devices. The blood glucose control system is called the Artificial Pancreas Controller (APC). During one of the studies, glucose will be controlled using the dual hormone mode. During another study, glucose will be controlled using the single hormone mode. The single and dual hormone modes of the APC controller determine insulin only and insulin with glucagon delivery rates based on proportional and derivative error and contain an exercise detection component. During the other study, glucose will be controlled using a predictive low glucose suspend (PLGS) mode. In the PLGS mode, the APC will be programmed with the subject's basal profile(s) which will be transmitted to the Omnipod Personal Diabetes Manager (PDM) and allow for boluses to be inputted by the subjects for meals and corrections using their typical carb ratios and correction factors. However, this system will have a safety feature to suspend insulin delivery when sensor glucose is predicted to go below a threshold. Treatment order will be randomized.
Subjects will arrive at the clinic at approximately 7 or 8am for the inpatient visits. Subjects will eat breakfast and lunch at approximately 8:30am, noon and 6pm respectively. The dinner meal will be consumed while the subject is at home. Subjects will exercise on a treadmill for 45 minutes. Subjects will be discharged 9 hours after admission. The subject will then go home for the remainder of the study visit. Studies will be remotely monitored. Subjects will return to OHSU on Day 4 for removal of all devices.
During each study, the subject will wear one subcutaneous DexcomTM G5 continuous glucose monitoring (CGM) system. The CGM system will provide sensed glucose data every 5 minutes. The accuracy of the sensed data will be obtained by reference measurements of capillary blood glucose. Sensed glucose data will be wirelessly transmitted via Bluetooth Low Energy (BTLE) from the Dexcom G5 transmitter to the Nexus 5 master controller every five minutes. The controller for all 3 modes is a Google Nexus 5 phone. The smart phone will wirelessly communicate via BTLE to an Omnipod through a PDM (Insulet Corp. ) for automated insulin delivery or in the case of dual-hormone AP, one used for automated insulin delivery and one for automated glucagon delivery.
A physician or nurse practitioner will be present for study start-up, will be on campus for exercise on Day 1 and will be immediately available on call at all other times.
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Crossover
- Masking
- None (open label)
- Number of arms
- 3
| Arm | Type | Receives |
|---|---|---|
| Dual Hormone Closed-loop Arm | Experimental | Device: Artificial Pancreas Controller in Dual Hormone Mode, Drug: XeriSol glucagonSubjects will undergo a 76 hour study with 9 hours inpatient and 67 hours outpatient using the closed-loop artificial pancreas controller in dual hormone mode and XeriSol glucagon to manage blood sugar that includes an exercise detection component that includes a reduction in insulin delivery and an increase in glucagon delivery upon detection. |
| Single Hormone Closed-loop Arm | Experimental | Device: Artificial Pancreas Controller in Single Hormone ModeSubjects will undergo a 76 hour study with 9 hours inpatient and 67 hours outpatient using the closed-loop artificial pancreas controller in single hormone mode to manage blood sugar that includes an exercise detection component that includes a reduction in insulin delivery upon detection. |
| Predictive Low Glucose Suspend Arm | Experimental | Device: Artificial Pancreas Controller in Predictive Low Glucose Suspend ModeSubjects will undergo a 76 hour study with 9 hours inpatient and 67 hours outpatient using the closed-loop artificial pancreas controller in predictive low glucose suspend mode. The system will run through the closed-loop system but will utilize the patient's optimized basal rates, correction factors and carb ratios as they would normally run on their own insulin pump. But the mode will have the additional safety net of the pump suspending insulin when it predicts a hypoglycemic event. |
Who may qualify
- Ages
- 21 to 50 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult
Key inclusion criteria (11 listed)
- Diagnosis of type 1 diabetes mellitus for at least 1 year.
- Male or female subjects 21-50 years of age.
- Physically willing and able to perform 45 min of exercise.
- Current use of an insulin pump.
- Lives with another person age 18 or older who will be present while subject exercises at home and that can attend the training on using the system.
Key exclusion criteria (32 listed)
- Female of childbearing potential who is pregnant or intending to become pregnant or breast-feeding, or is not using adequate contraceptive methods. Acceptable contraception includes birth control pill/patch/vaginal ring, Depo-Provera, Norplant, an IUD, the double barrier method (the woman uses a diaphragm and spermicide and the man uses a condom), or abstinence.
- Any cardiovascular disease, defined as a clinically significant EKG abnormality at the time of screening or any history of: stroke, heart failure, myocardial infarction, angina pectoris, or coronary arterial bypass graft or angioplasty. Diagnosis of 2nd and 3rd degree heart block or any non-physiological arrhythmia judged by the investigator to be exclusionary.
- Renal insufficiency (GFR < 60 ml/min, using the MDRD equation as report by the OHSU laboratory).
- Liver failure, cirrhosis, or any other liver disease that compromises liver function as determined by the investigator.
- Hematocrit of less than 36% for men, less than 32% for women.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Artificial Pancreas Controller in Dual Hormone ModeThe artificial pancreas controller contains an algorithm for managing blood glucose in people with type 1 diabetes which includes an exercise detection component. The algorithm has 3 modes: a single hormone closed-loop insulin only mode, a dual-hormone closed-loop insulin and glucagon mode and an insulin only mode with predictive low glucose suspend. The Closed-loop Artificial Pancreas Controller includes insulin and glucagon delivery algorithm implemented on a smart phone, utilizing sensor glucose values from a Dexcom G5 sensor and sending delivery commands to two Omnipod insulin pumps, one filled with insulin and one with glucagon. | Device | Dual Hormone Closed-loop Arm |
| Artificial Pancreas Controller in Single Hormone ModeThe artificial pancreas controller contains an algorithm for managing blood glucose in people with type 1 diabetes which includes an exercise detection component. The new algorithm will have 3 modes: a single hormone closed-loop insulin only mode, a dual-hormone closed-loop insulin and glucagon mode and an insulin only mode with predictive low glucose suspend. The Closed-loop Artificial Pancreas Controller includes insulin delivery algorithm implemented on a smart phone, utilizing sensor glucose values from a Dexcom G5 sensor and sending delivery commands to one Omnipod pump filled with insulin. | Device | Single Hormone Closed-loop Arm |
| Artificial Pancreas Controller in Predictive Low Glucose Suspend ModeThe artificial pancreas controller contains an algorithm for managing blood glucose in people with type 1 diabetes which includes an exercise detection component. The new algorithm will have 3 modes: a single hormone closed-loop insulin only mode, a dual-hormone closed-loop insulin and glucagon mode and an insulin only mode with predictive low glucose suspend. The Closed-loop Artificial Pancreas Controller includes insulin delivery algorithm implemented on a smart phone, utilizing sensor glucose values from a Dexcom G5 sensor and sending delivery commands to one Omnipod insulin pump filled with insulin. | Device | Predictive Low Glucose Suspend Arm |
| XeriSol glucagonXeriSol glucagon is an investigational drug that is a stable, soluble liquid glucagon formulation that can be injected or administered through an insulin pump. XeriSol glucagon will be used to fill the Omnipod to deliver glucagon for the Artificial Pancreas Controller in Dual Hormone mode. | Drug | Dual Hormone Closed-loop Arm |
Primary outcome
Percent of Time With Sensed Glucose < 70 mg/dl
Time frame: 4 hours post exercise on Day 1
Assess the percent of time that the Dexcom G5 or G6 reported sensor glucose values less than 70 mg/dl using Dexcom sensor across all three arms.
6 secondary outcomes
Percent of Time With Sensed Glucose Between 70-180 mg/dl
Time frame: entire 76 hour study
Number of Carbohydrate Treatments
Time frame: 24 hours
Percent of Time With Sensed Glucose < 54 mg/dl
Time frame: entire 76 hour study
Percent of Time With Sensed Glucose > 180 mg/dl
Time frame: entire 76 hour study
Mean Amount of Insulin Delivered in One Day
Time frame: 24 hours
Mean Amount of Glucagon Delivered in One Day
Time frame: 24 hours
Results and safety
Loading the posted results from ClinicalTrials.gov…
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 27 May 2020.
- Posted resultsParticipant flow, baseline, all outcome measures and adverse events.
- Derived from this study: PubMed 32907828Wilson LM, Jacobs PG, Ramsey KL, Resalat N, Reddy R, Branigan D, Leitschuh J, Gabo V, Guillot F, Senf B, El Youssef J, Steineck IIK, Tyler NS, Castle JR. Dual-Hormone Closed-Loop System Using a Liquid Stable Glucagon Formulation Versus Insulin-Only Closed-Loop System Compared With a Predictive Low Glucose Suspend System: An Open-Label, Outpatient, Single-Center, Crossover, Randomized Controlled Trial. Diabetes Care. 2020 Nov;43(11):2721-2729. doi: 10.2337/dc19-2267. Epub 2020 Sep 9.
Related trials for Type1diabetes
Active, not recruitingPhase 4
Diabetes in African Youth
type1diabetes
Recruiting
Cardiometabolic Effects of Non-Nutritive Sweeteners (NNS) in Type 1 Diabetes (T1D)
Non-Nutritive Sweetener, Type 1 Diabetes
Active, not recruitingPhase 2
Reducing Innate Inflammation in New Onset Type 1 Diabetes
Type 1 Diabetes, type1diabetes
Active, not recruiting
Teamwork, Targets, Technology, and Tight Control in Newly Diagnosed Pediatric T1D - 4T Study
Type1diabetes
Recruiting
Safety and Effectiveness of A Novel Continuous Glucose and Ketone Monitoring System
Type1diabetes
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Jessica Castle, MD principal investigator
Oregon Health and Science University
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A Phase 1 study testing XeriSol glucagon in people with Type1diabetes, run by Oregon Health and Science University at 1 site in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 11 inclusion and 32 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 27 May 2020. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
What does this phase mean?
Phase 1 studies test a treatment in a small group of people for the first time or in a new way, mainly to check safety and find the right dose.
Not every study follows the same path, and some studies (observational studies, device studies) have no phase.
Are results available for this study?
Yes. Results are posted in the registry (first posted 13 May 2020). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Percent of Time With Sensed Glucose < 70 mg/dl (time frame: 4 hours post exercise on Day 1). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT03424044, which also lists 1 linked publication.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 27 May 2020.