Mitral Valve RegurgitationNCT03285724

Safety and Performance Study of the Harpoon Mitral Valve Repair System

A study testing Harpoon Artificial ePTFE Chords in people with Mitral Valve Regurgitation and Mitral Valve Prolapse, run by Edwards Lifesciences at 2 sites in Poland.

Terminated

Stopped early. The study ended before it was planned to and will not resume.

Official record
Search all trials

Trial summary

The primary objective of this study is to evaluate the safety and performance of the Harpoon Medical Device. It is anticipated, that the Harpoon Medical Device will provide advantages over current surgical interventions including: 1) a small minimally invasive incision, 2) no sternotomy, 3) no cardiopulmonary bypass… Read more about this study

Who is it for?
Ages 18 years and older
What is being tested?
Harpoon Artificial ePTFE Chords
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
1 participants
Where
2 sitesPoland
Study dates
16 May 2017to 20 Apr 2018
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Age ≥ 18 years
  • Patient referred for mitral valve surgery
  • Presence of severe MR as read on an echocardiographic study performed within 60 days prior to procedure.
  • Estimated post-ePTFE cordal implantation coaptation surface is adequate in the judgment of the operating surgeon and the patient eligibility committee
  • Degenerative mitral valve disease associated with anterior, bileaflet, or posterior leaflet prolapse
  • Patient is able to sign informed consent and able to return for follow-up and is capable of participating in all testing associated with this clinical investigation
  • Women of child-bearing potential have a negative pregnancy test

Who cannot join

  • Age < 18 years
  • Infective endocarditis
  • History of Mediastinal Radiation
  • Inflammatory (rheumatic) valve disease
  • Requirement for concomitant cardiac surgery (e.g., coronary artery bypass grafting (CABG), aortic valve surgery, etc.)
  • Symptomatic coronary artery disease
Show all 23Show fewer
  • Cardiogenic shock at the time of enrollment
  • ST segment elevation myocardial infarction requiring intervention within 30 days prior to enrollment
  • Evidence of cirrhosis or hepatic synthetic failure
  • Pregnancy at the time of enrollment (women of child bearing age should have negative pregnancy within 14 days of surgery)
  • Severe pulmonary hypertension (PA systolic pressure > 70 mmHg)
  • Previous cardiac surgery, or surgery on the left pleural space
  • Left ventricular, atrial or appendage thrombus
  • Severely calcified mitral leaflets
  • Recent stroke (< 6 months) with permanent impairment
  • EuroScore (for mitral valve repair) > 8%
  • Patients with contraindications to Transesophageal echocardiography
  • Severe left or right ventricular dysfunction
  • NYHA Class IV
  • Renal insufficiency CKD stage 3b or worse (GFR < 45 ml/min/1.73 m2)
  • Patient is participating in another clinical study for which follow-up is currently ongoing. (Co-enrollment in an investigational device or interventional study)
  • Patient with non-cardiac co-morbidities and life expectancy < 1 year
  • Patient has a condition or conditions that, in the opinion of the Investigator, preclude participation, including willingness to comply with all follow-up procedures

Trial locations and contacts

2 sites in 1 country.

Poland2 sites
  • Jagiellonian University

    Krakow

  • Instytut of Kardiologii & Transplantology

    Warsaw, 04-628

Other trials in Poland

About this study

Official title: Safety and Performance Study of the Harpoon Medical Device in Patients With Degenerative Mitral Regurgitation

The primary objective of this study is to evaluate the safety and performance of the Harpoon Medical Device. It is anticipated, that the Harpoon Medical Device will provide advantages over current surgical interventions including: 1) a small minimally invasive incision, 2) no sternotomy, 3) no cardiopulmonary bypass, 4) no aortic manipulation, 5) a direct path to the valve plane, 6) performed on a beating heart, 7) real-time TEE-guided ePTFE cordal length adjustment and 8) less complicated procedure that is teachable and adoptable.

Read the detailed description

The device is designed to reduce the degree of mitral regurgitation by delivering and anchoring artificial chordae tendineae to the affected mitral valve leaflet(s) in a beating heart.

Being tested
Harpoon Artificial ePTFE Chords
Keywords
Mitral Valve Repair, Transapical, artificial chordae, bi-leaflet prolapse, anterior prolapse, posterior prolapse
Medical subject headings
Mitral Valve Insufficiency, Mitral Valve Prolapse

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Harpoon Artificial ePTFE ChordsDevice

    The Harpoon Medical Transapical device is intended to be used to reduce the degree of degenerative mitral regurgitation by delivering and anchoring one or more ePTFE cords to the affected mitral valve leaflet(s) via a small left thoracotomy on the beating heart in patients with anterior, bi-leaflet or posterior prolapse.

Study groups in NCT03285724
Study groupRoleWhat they receive
Harpoon Medical Transapical device TSD-5ExperimentalThis is a prospective, single arm, nonrandomized, early feasibility study to evaluate the safety and performance of the Harpoon Medical Device.
Receives: Device: Harpoon Artificial ePTFE Chords

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Number of Subjects With Procedural Success During the First 30 Days

    To demonstrate that the Harpoon Medical Device performs as designed and can successfully implant one or more ePTFE artificial cords on either the anterior, posterior, or both leaflets of the mitral valve via a small left thoracotomy on the beating heart and reduce mitral regurgitation from "severe" to less than or equal to "moderate" at the conclusion of the procedure and at 30 days post-procedure.

    Measured: Procedure, discharge, and 30 days

  2. Number of Subjects With Freedom From Serious Adverse Events (SAE) During the First 30 Days

    Procedure freedom from Serious Adverse Events (SAEs) during the procedure, at discharge, and at 30 days follow-up shall be tracked and recorded.

    Measured: Procedure, Discharge and 30 Days

Secondary outcomes (2)
  1. Subject's Severity of Mitral Regurgitation Over Time

    Severity of mitral regurgitation at 6 months, 12 months and 24 months follow-up shall be tracked and recorded

    Measured: 6 Months, 12 Months, and 24 Months

  2. Subject's Freedom From Serious Adverse Events Over Time

    Freedom from Serious Adverse Events (SAEs) at 6 months, 12 months and 24 months follow-up shall be tracked and recorded

    Measured: 6 Months, 12 Months, and 24 Months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted18 Sep 2017
  2. Study start16 May 2017
  3. Primary completion16 Jun 2017
  4. Study completion20 Apr 2018

Why it stopped: Edwards Lifesciences acquired Harpoon Medical in December 2017 and a decision has been made to close enrollment in the HMEFS-2000 protocol

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Model description
Single Group Assignment
Masking
None (open label)
Enrolment
1 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03285724
Sponsor's protocol ID
HMEFS-2000
Status last verified
Nov 2019
First submitted
14 Sep 2017
Last updated
19 Nov 2019
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
Undecided

Questions about this trial

What is this clinical trial studying?

A study testing Harpoon Artificial ePTFE Chords in people with Mitral Valve Regurgitation and Mitral Valve Prolapse, run by Edwards Lifesciences at 2 sites in Poland.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 7 inclusion and 23 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: stopped early, as of the sponsor's last update on 19 Nov 2019. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 2 sites in Poland. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 14 Oct 2019). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Number of Subjects With Procedural Success During the First 30 Days (time frame: Procedure, discharge, and 30 days). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 19 Nov 2019.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in