AzTrials
AzTrials

Fluid TherapyNCT03280953

Assessing Fluid Responsiveness With PWTT

An observational study of Fluid Therapy and Monitoring, Intraoperative, run by Johannes Gutenberg University Mainz at 1 site in Germany.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Pulse wave Transit time (PWTT) is a parameter calculated from ECG and pulseoximeter. It is supposed to help assessing the preload Status and guide intraoperative fluid therapy. This Project aims to validate the benefit of PWTT assessment in an observational clinical fluid study. Read more about this study

Who is it for?
Ages 18 to 80 years
Conditions the study is for
Fluid Therapy, Monitoring, Intraoperative
What is being tested?
Assessing fluid responsiveness by PWTT value
How many people
38 participants
Where
1 siteGermany
Study dates
31 May 2016to 31 Jan 2019
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 80 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Study population: Patients who are scheduled for elective open abdominal surgery

Who may be able to join

  • Adults 18 - 80 years old
  • elective open abdominal surgery
  • clinical indication for direct arterial blood pressure Monitoring
  • supine Position intraoperatively

Who cannot join

  • under 18 years, over 80 years old
  • pregnant
  • no informed consent
  • systemic inflammatory response syndrome (SIRS) or Sepsis
  • Severe cardiac, coronary or vascular disease
  • Arrythmia
Show all 12Show fewer
  • Cardiac valves anomaly
  • BMI > 35
  • American Society of Anesthesiologists (ASA) physical status classification system: 4
  • Lung disease that excludes Ventilation with a tidal volume >8ml/kg
  • esophageal pathology
  • planned prone position surgery

Trial locations and contacts

1 site in 1 country.

Germany1 site
  • University Medical Center of Johannes Gutenberg University

    Mainz, Rhineland-Palatinate, 55131

Other trials in Germany

About this study

Official title: Finding the Cut-off Value of Pulse Wave Transit Time (PWTT) to Estimate the Fluid Responsibility

Pulse wave Transit time (PWTT) is a parameter calculated from ECG and pulseoximeter. It is supposed to help assessing the preload Status and guide intraoperative fluid therapy. This Project aims to validate the benefit of PWTT assessment in an observational clinical fluid study. In case of hypovolemia, patients will receive a fluid Bolus and hemodynamic data from clinical Standard Monitoring, esophageal doppler and PWTT will be recorded before and after the fluid Bolus. Receiver operating characteristic (ROC) curve will be used to determine the validity of PWTT as indicator for fluid responsiveness and its cut off value.

Read the detailed description

PWTT is determined by measuring the beginning and the end of pulse wave duration and can be calculated as the time interval from the ECG R-wave peak to the rise point of the pulse oximeter wave.

it consists of two components: pre ejection period (PEP) and arterial pulse wave transit time (a-PWTT). PEP is defined as the time from the ECG R wave to the rise point of the aortic root pressure wave. a-PWTT is defined as the time from the rise point of the aortic pressure wave to the rise point of the pulse oximeter wave. a-PWTT is the component which is directly related to the velocity of the pulse wave. However noninvasively, we can measure only PWTT, which also includes PEP. In general, PEP change over short periods of time is negligible in most cases, so we can assume that PWTT corresponds to

a-PWTT. In studies using several studies using animals and healthy volunteers, PWTT showed good correlation with stroke volume or systolic blood pressure. Also in experimental and clinical setting, it is shown that PEP changes indicate change in preloads.

It is not known at this moment, which of the following factors to be considered in processing raw data to acquire accurate PWTT value on predicting fluid responsiveness.

  1. The beginning of pulse wave can be assessed by the appearance of either Q wave, which represents the initial phase of depolarisation going through the interventricular septum or R wave, which represents the ventricular depolarisation in ECG.
  2. The end of pulse wave duration can be assessed by peripheral plethysmography mostly from a finger tip but also from an ear lobe.
  3. The pulse wave time can be simply measured as it is, but can also be adjusted by heart rate using Bazett-Formula.
  4. Not only the simple PWTT but also ventilatory induced fluctuation of PWTT (ΔPWTT) may be used for predicting fluid responsiveness.
Being tested
Assessing fluid responsiveness by PWTT value

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Assessing fluid responsiveness by PWTT valueDiagnostic test

    PWTT value will be analysed to find the cutoff values compared by esophageal doppler and pulse pressure variation.

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. PWTT change before and after fluid bolus

    PWTT recorded before and 1 minute after fluid bolus of 7ml/kg intraoperatively. PWTT values will be calculated: defining PWTT start by either Q-wave or R-wave, defining PWTT end at arrival of the plethysmographic signal either at the finger tip or at the ear lobe, defining PWTT length by either simple measurement or adjusted by the Bazett-Formula. Additionally, as a dynamic parameter respiratory variation of PWTT (ΔPWTT) will be computed.

    Measured: 1 day

Secondary outcomes (5)
  1. Heart rate before and after fluid bolus

    Heart rate (in beats per minute), derived from intraoperative standard monitoring. This hemodynamic parameter will be measured before and 1min after fluid bolus.

    Measured: 1 day

  2. Blood pressure before and after fluid bolus

    Systolic blood pressure/diastolic blood pressure/mean arterial pressure (in millimeters of mercury), derived from intraoperative standard monitoring. This hemodynamic parameter will be measured before and 1min after fluid bolus.

    Measured: 1 day

  3. Flow Time corrected before and after fluid bolus

    Flow Time corrected (in milliseconds) measured by esophageal doppler. This hemodynamic parameter will be measured before and 1min after fluid bolus.

    Measured: 1 day

  4. Stroke volume before and after fluid bolus

    Stroke volume (in milliliters per heartbeat) measured by esophageal doppler. This hemodynamic parameter will be measured before and 1min after fluid bolus.

    Measured: 1 day

  5. Pulse Pressure Variation before and after fluid bolus

    Pulse Pressure Variation (as percentage) assessed using arterial pressure monitoring. This hemodynamic parameter will be measured before and 1min after fluid bolus.

    Measured: 1 day

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted13 Sep 2017
  2. Study start31 May 2016
  3. Primary completion31 Dec 2018
  4. Study completion31 Jan 2019

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Case only
Time perspective
Prospective
Enrolment
38 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03280953
Sponsor's protocol ID
837.004.16
Status last verified
Jul 2020
First submitted
25 Apr 2017
Last updated
30 Jul 2020
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Rhodes A, Cecconi M, Hamilton M, Poloniecki J, Woods J, Boyd O, Bennett D, Grounds RM. Goal-directed therapy in high-risk surgical patients: a 15-year follow-up study. Intensive Care Med. 2010 Aug;36(8):1327-32. doi: 10.1007/s00134-010-1869-6. Epub 2010 Apr 8.

    PubMed 20376431

Questions about this trial

What is this clinical trial studying?

An observational study of Fluid Therapy and Monitoring, Intraoperative, run by Johannes Gutenberg University Mainz at 1 site in Germany.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 12 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 30 Jul 2020. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Germany. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

PWTT change before and after fluid bolus (time frame: 1 day). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT03280953, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 30 Jul 2020.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in