Epidural AnalgesiaNCT03161717

Efficacy and Safety of Electrical Stimulation-guided Epidural Analgesia for Vaginal Delivery

A study testing Epidural electrical stimulation (EES) and Loss of resistance (LOR) in people with Epidural Analgesia, run by Sang Sik Choi at 1 site in South Korea.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

Forty pregnant women (36 to 41 weeks gestation) will randomly allocate to two groups. Groups will be defined based on the method used to identify the epidural space for epidural anesthesia: the loss of resistance group (n=20) and the epidural electrical stimulation group (n=20). Read more about this study

Who is it for?
Ages 19 years and older, women onlyHealthy volunteers can take part
Conditions the study is for
Epidural Analgesia
What is being tested?
Epidural electrical stimulation (EES) and Loss of resistance (LOR)
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
40 participants
Where
1 siteSouth Korea
Study dates
11 Mar 2015to Mar 2019
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 19 years and older
  • Women only
  • Healthy volunteers accepted
  • Adult, Older adult

Who may be able to join

  • Patients who were at 36 to 41 weeks' gestation and admitted in labor to the university clinic for vaginal delivery were included. Patients were American Society of Anesthesiologists (ASA) physical status of I or II, and were scheduled to receive epidural analgesia

Who cannot join

  • Skin infection at the injection site
  • Difficult catheter placement owing to previous lumbar spinal surgery or deformity
  • Presence of a hemostatic disorder or use of antiplatelet therapy
  • Injection of an analgesic within the previous 12 hours
  • Presence of a cardiac pacemaker

Trial locations and contacts

1 site in 1 country.

Chung Hun Lee, MD contact

82-2-2626-3240

bodlch@naver.com

Sang Sik Choi, MD, PhD contact

82-2-2626-3238

clonidine@empal.com

South Korea1 site, 1 recruiting
  • Korea University Guro Hospital

    Seoul, 08308

    Seung-hoe Song, MBE, 82-2-2626-1635, ssessong@korea.ac.kr

    Da-in Lee, 82-2-2626-2279, 0124dain@gmail.com

    Recruiting

Other trials in South Korea

About this study

Official title: A Comparative Study of Success Rate, Efficacy, Safety Between Electrical Stimulation-guided Epidural Catheter Placement and the Loss of Resistance Conventional Method for Vaginal Delivery

Forty pregnant women (36 to 41 weeks gestation) will randomly allocate to two groups. Groups will be defined based on the method used to identify the epidural space for epidural anesthesia: the loss of resistance group (n=20) and the epidural electrical stimulation group (n=20). Pain will be assessed using a numerical visual analog scale and maternal satisfaction by a post-partum interview. The success rate of epidural analgesia, maternal satisfaction, and neonatal Apgar scores will be compared between groups.

Read the detailed description

Investigators will place epidural catheter in the epidural space using loss of resistance technique, and will confirm correct placement of the epidural catheter using electrical stimulation.

Epidural catheter placement, electrical stimulation, and confirmation of response is followed:

Patients will be placed in the left lateral decubitus position. The site will be aseptically prepared and 1% lidocaine will be infiltrated to the skin. An 18-gauge Tuohy needle will be inserted midline of L4/5 interspinous space.

For the Loss of resistance (LOR) group, after identification of the epidural space, the Tuohy needle will be stopped, and a 20-gauge epidural catheter will be advanced through the Tuohy needle.

The same process will be followed for the Epidural electrical stimulation (EES) group. In addition, the epidural space will be confirmed by epidural electrical stimulation using a 20-gauge epidural catheter (RegionalStimTm, Sewoon Medical Co., Ltd, Seoul, Korea, 800 mm) with a conductive guidewire (conductive guidewire, Nitinol, 1100 mm).

After confirming there is no reverse flow of cerebrospinal fluid or blood with aspiration, 3 mL of 1% lidocaine, with 15 mcg of epinephrine (1:200000), will be injected through the epidural catheter as test dose. If there is no response to the test dose, patients will be moved to the delivery room. To control labor pain, a one-time injection containing 50 mcg of fentanyl, 3 mL of 0.75% ropivacaine, and 6 mL of normal saline (total volume 10 mL) will be administered. A continuous infusion of 3 to 10 mL/hour depending on the patient's pain will be used of 75 mcg of fentanyl, 8.5 mL of 0.75% ropivacaine, and 40 mL of normal saline (total volume 50 mL).

Blood pressure (BP), heart rate (HR), oxygen saturation (SpO2), and neurologic assessment findings will be monitored up to 72 hours after labor.

Pain relief in labor is assessed by a change in the visual analogue scale (VAS) score. A 10 point VAS, where 0 is no pain and 10 is unbearable pain, is used to assess pain during labor. The scale is assessed before epidural anesthesia and after epidural anesthesia. Differences in the VAS response we used to assess the efficacy of the epidural anesthesia in decreasing labor pain. Comparison of the change in VAS between groups is used to compare pain control of the two methods. The success of epidural analgesia is defined by sensory block, without motor block, and a decrease in pain score after adequate dosing of epidural medication. Failure of epidural analgesia is defined by a lack of sensory block and a less that 2 point difference on the VAS after adequate dosing of epidural medications.

Patient satisfaction will be evaluated by a postpartum interview. Satisfaction is graded between a score of 1-5, where 1 represent very unsatisfied and 5 represent very satisfied. Patients will indicate a score of 1 to 5.

One- and 5-minute Apgar scores will be compared to assess the effect of epidural electrical stimulation on the neonate. Additional time required for epidural electrical stimulation will be determined by the difference (in seconds) from LOR to identification of the epidural space through electrical stimulation.

Being tested
Epidural electrical stimulation (EES), Loss of resistance (LOR)
Keywords
electrical stimulation, vaginal delivery

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Epidural electrical stimulation (EES)Device

    Using loss of resistance technique and electrical stimulation

  • Loss of resistance (LOR)Device

    Using loss of resistance technique only

Study groups in NCT03161717
Study groupRoleWhat they receive
Epidural electrical stimulation (EES)Experimentaln=20
Receives: Device: Epidural electrical stimulation (EES)
Loss of resistance (LOR)Active comparatorn=20
Receives: Device: Loss of resistance (LOR)

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Success rate of epidural analgesia

    Evaluation parameter : Accuracy comparison between loss of resistance and epidural electrical stimulation

    Measured: Up to 6 months

Secondary outcomes (5)
  1. Maternal satisfaction

    Patient satisfaction will be evaluated by a postpartum interview. Satisfaction is graded between a score of 1-5, where 1 represent very unsatisfied and 5 represent very satisfied. Patients will indicate a score of 1 to 5

    Measured: Up to 6 months

  2. Neonatal Apgar score

    Assessment of neonatal

    Measured: Up to 6 months

  3. Procedure-related complications

    • Check allergy reaction of anesthetics or chlorohexidine
    • Check whether Insert of local anesthetics to intravascular or not

    Measured: Up to 6 months

  4. Minimum electrical current to elicit a response in the epidural electrical stimulation group

    • Check stimulation strength that patients begin the feel for the first
    • Check the proper stimulation part of body

    Measured: Up to 6 months

  5. Additional time for epidural electrical stimulation

    Determined by the difference (in seconds) from loss of resistance(LOR) to identification of the epidural space through electrical stimulation

    Measured: Up to 6 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted22 May 2017
  2. Study start11 Mar 2015
  3. Primary completionMar 2019 (estimated)
  4. Study completionMar 2019 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Model description
Parallel Assignment
Masking
None (open label)
Enrolment
40 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03161717
Sponsor's protocol ID
MD14043 (RegionalStimⓡ)
Status last verified
May 2017
First submitted
18 May 2017
Last updated
22 May 2017
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Silva M, Halpern SH. Epidural analgesia for labor: Current techniques. Local Reg Anesth. 2010;3:143-53. doi: 10.2147/LRA.S10237. Epub 2010 Dec 8.

    PubMed 23144567
  • Wantman A, Hancox N, Howell PR. Techniques for identifying the epidural space: a survey of practice amongst anaesthetists in the UK. Anaesthesia. 2006 Apr;61(4):370-5. doi: 10.1111/j.1365-2044.2006.04534.x.

    PubMed 16548958
  • Eappen S, Blinn A, Segal S. Incidence of epidural catheter replacement in parturients: a retrospective chart review. Int J Obstet Anesth. 1998 Oct;7(4):220-5. doi: 10.1016/s0959-289x(98)80042-3.

    PubMed 15321183
  • Hermanides J, Hollmann MW, Stevens MF, Lirk P. Failed epidural: causes and management. Br J Anaesth. 2012 Aug;109(2):144-54. doi: 10.1093/bja/aes214. Epub 2012 Jun 26.

    PubMed 22735301
  • Tsui BC, Tarkkila P, Gupta S, Kearney R. Confirmation of caudal needle placement using nerve stimulation. Anesthesiology. 1999 Aug;91(2):374-8. doi: 10.1097/00000542-199908000-00010.

    PubMed 10443599
  • Tsui BC, Gupta S, Finucane B. Confirmation of epidural catheter placement using nerve stimulation. Can J Anaesth. 1998 Jul;45(7):640-4. doi: 10.1007/BF03012093.

    PubMed 9717595

Questions about this trial

What is this clinical trial studying?

A study testing Epidural electrical stimulation (EES) and Loss of resistance (LOR) in people with Epidural Analgesia, run by Sang Sik Choi at 1 site in South Korea.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 22 May 2017. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in South Korea. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Chung Hun Lee, MD (82-2-2626-3240, bodlch@naver.com), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Success rate of epidural analgesia (time frame: Up to 6 months). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT03161717, which also lists 6 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 22 May 2017.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in