Plasma of Argon Cleaning on Implant Abutments: 5-year Results of a Randomized Clinical Trial

A study testing Steam clean and Plasma of Argon in people with Endosseous Dental Implant Failure and Alveolar Bone Loss, run by University of Valencia.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Contamination of implant abutments could potentially influence the peri-implant tissue inflammatory response. The aim of the present study was to assess the radiographic bone changes around customized, platform switched, abutments placed according to the "one-abutment-one-time" protocol, with and without plasma of… Read more about this study

Who is it for?
Ages 18 years and older
What is being tested?
Steam clean and Plasma of Argon
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
30 participants
Where
No sites listed yet
Study dates
Jan 2010to Sep 2015
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Patients aged 18 years or older, previously treated for periodontal disease according to a comprehensive treatment strategy,25 requiring a single implant-supported restoration in the anterior maxilla or premolar region with the presence of mesial and distal tooth.
  • Bone crest allowing the insertion of a 4 mm platform implant without further bone augmentation procedures and with thin (≤ 1 mm) gingival biotype, measured by previously reported protocol.

Who cannot join

  • no relevant medical conditions;
  • non-smoker or smoking ≤ 10 cigarettes/day;
  • plaque Index and bleeding on probing ≤ 25 %;
  • impossibility of follow-up for 5 years after prosthetic loading;
  • pregnant and lactating patients;
  • patients with a history of bisphosphonate therapy;
  • presence of sites with acute infections.

About this study

Official title: Effect of Plasma of Argon Cleaning on Implant Abutments in Patients With a History of Periodontal Disease and Thin Biotype: Five Years Post-loading Results of a Randomized Controlled Trial

Contamination of implant abutments could potentially influence the peri-implant tissue inflammatory response. The aim of the present study was to assess the radiographic bone changes around customized, platform switched, abutments placed according to the "one-abutment-one-time" protocol, with and without plasma of argon cleaning treatment.

Read the detailed description

After technical procedures, presence of contaminants (mostly Titanium wear micro-particles, Carbon and Aluminum traces due to lubricant used during customization) on the whole abutment surface, the internal connection and the screw can be found, even after the usually cleaning steps (steaming).

Such debris, present at titanium/connective-bone tissues interface (gingival portion of the abutment), could directly or indirectly deleteriously influence the inflammatory response on the peri-implant tissues.

Plasma of Argon cleaning treatment was demonstrated to have a double effect on titanium abutments: removal of pollutions following customization and increase of cell adhesion. Additionally, Plasma of Argon demonstrated very potent anti-biofilm activity. This prospective, match paired, triple-blinded randomized controlled trial was aimed to test if plasma treatment of customized abutments can affect radiographic peri-implant marginal bone level changes after 5 years of prosthetic loading.

Being tested
Steam clean, Plasma of Argon
Medical subject headings
Alveolar Bone Loss

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Steam cleanDevice

    Control group: dental implant abutments underwent cleaning by steam (VAP 1, Zhermark, Cologne, Germany), performed for 5 seconds at 4 megapascal (MPa).

  • Plasma of ArgonDevice

    Test group: dental implant underwent argon plasma treatment in a plasma reactor (Diener Electronic, Jettingen, Germany). The treatment conditions were 75 W of power and 1 bar of pressure for 12 minutes.

Study groups in NCT02552810
Study groupRoleWhat they receive
Plasma of ArgonActive comparatorAbutment cleaning by plasma of Argon protocol .
Receives: Device: Plasma of Argon
Steam cleanActive comparatorAbutment cleaning by steam clean device.
Receives: Device: Steam clean

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Success Rate of the Implants and Prostheses (Participants).

    An implant was considered a failure if it presented any mobility, assessed by tapping or rocking the implant head with the metallic handles of two instruments, and/or any signs of radiolucency, progressive marginal bone loss or infection, and any mechanical complications (e.g. implant fracture) rendering the implant unusable, though still mechanically stable in the bone. This was evaluated on an intraoral radiograph taken with a paralleling technique strictly perpendicular to the implant-bone interface. The implant stability was assessed at initial loading and following 3 years of application, with the prostheses removed.

    A prosthesis was considered a failure if it needed to be replaced by an alternative prosthesis.

    Measured: During all the follow-up (5 years)

Secondary outcomes (5)
  1. Any Biological or Technical Complications.

    Complications: any biological (pain, swelling, suppuration, etc) and/or mechanical complications (fracture of the framework and/or the veneering material, screw loosening, etc) were considered.

    Measured: During all the follow-up (5 years)

  2. Peri-implant Marginal Bone Level Changes (Express in mm).

    At the time of loading with the provisional crown (T0), periapical standardized digital or analogical radiographs were taken in order to control the perfect adaptation of the abutment on the implant and control peri-implant bone level. The customized film holder was made using an hard silicone on the bite of film holders (Rinn XCP; Dentsply Rinn, Elgin, IL, USA) and the parallel technique was used. Radiographs were also taken at 12 (T1), 24 (T2), 48 (T4), and 60 months (T5) after the final restoration delivery, to evaluate marginal bone level changes.

    Measured: At 5 years.

  3. Esthetic Parameters Measured as the Changes in Mesial and Distal Papilla Height (PH) and Buccal Peri-implant Mucosa Changes at the Zenith (REC), Expressed in mm.

    A customized millimeter tubular support (stent) was placed temporarily around each dental implant. For each site, mesial and distal soft tissue dimensions (papilla height, PH), and buccal peri-implant mucosa dimension at the zenith (REC) were measured, and reported in millimeters. Two measurements were recorded. The first at definitive crown delivery (baseline), and the second at the 5 years follow-up examination. Changes in PH and REC were reported in millimeters as the difference between values recorded at the 5-year follow-up and the baseline.

    The full procedure was published in:

    Canullo L, Iurlaro G, Iannello G. Double-blind randomized controlled trial study on post-extraction immediately restored implants using the switching platform concept: soft tissue response. Preliminary report. Clinical Oral Implants Research [Internet]. 2009 Apr;20(4):414-20.

    Measured: At 5 years.

  4. Percentage of Patients With Plaque Index

    Modified Plaque Index (mPI) was evaluated as the amount of plaque at the cervical part of the implant-supported crown, scored by running a probe along the implant-supported crown surface. Measured as Yes or Not.

    Measured: At 5 years.

  5. Percentage of Patients With Bleeding on Probing

    Presence of bleeding within 10 seconds after probing. Measured as Yes or Not.

    Measured: At 5 years.

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted17 Sep 2015 (estimated)
  2. Study startJan 2010
  3. Primary completionSep 2010
  4. Study completionSep 2015

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
Double blind
Who is masked
Participant, Outcomes assessor
Enrolment
30 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02552810
Sponsor's protocol ID
UValencia_001_Plasma
Status last verified
May 2016
First submitted
14 Sep 2015
Last updated
17 Jun 2016
Data monitoring committee
Yes
Individual data sharing
No

Publications

  • Canullo L, Penarrocha D, Clementini M, Iannello G, Micarelli C. Impact of plasma of argon cleaning treatment on implant abutments in patients with a history of periodontal disease and thin biotype: radiographic results at 24-month follow-up of a RCT. Clin Oral Implants Res. 2015;26(1):8-14. doi: 10.1111/clr.12290. Epub 2013 Nov 6.

    PubMed 24191873

Questions about this trial

What is this clinical trial studying?

A study testing Steam clean and Plasma of Argon in people with Endosseous Dental Implant Failure and Alveolar Bone Loss, run by University of Valencia.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 7 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 17 Jun 2016. Status can change between updates, so confirm with the study contact before making plans.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 17 Jun 2016). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Success Rate of the Implants and Prostheses (Participants). (time frame: During all the follow-up (5 years)). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT02552810, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 17 Jun 2016.