Aortic StenosisPERIGONNCT02088554
PERIGON Pivotal Trial
A study testing Model 400 aortic valve bioprosthesis in people with Aortic Stenosis, run by Medtronic Cardiac Surgery at 38 sites in 8 countries.
Trial summary
To evaluate the safety and effectiveness of the Model 400 aortic valve bioprosthesis. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Aortic Stenosis
- What is being tested?
- Model 400 aortic valve bioprosthesis
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 1,312 participants
- Where
- 38 sitesin 8 countries
- Study dates
- 12 May 2014to 31 Dec 2035
- Phase
- Interventional
- Are there results?
- Yes, posted in the registrySummary in the doctors' view
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Patient has moderate or greater aortic stenosis or regurgitation, and there is clinical indication for replacement of their native or prosthetic aortic valve with a bioprosthesis, with or without concomitant procedures, which are limited to any of the following:
- Left atrial appendage (LAA) ligation ii. CABG (coronary artery bypass grafting) iii. Patent foramen ovale (PFO) closure iv. Ascending aortic aneurysm or dissection repair not requiring circulatory arrest v. Resection of a sub-aortic membrane not requiring myectomy
- Patient is geographically stable and willing to return to the implanting site for all follow-up visits
- Patient is of legal age to provide informed consent in the country where they enroll in the trial
- Patient has been adequately informed of risks and requirements of the trial and is willing and able to provide informed consent for participation in the clinical trial
Who cannot join
- Patient has a pre-existing prosthetic valve or annuloplasty device in another position or requires replacement or repair of the mitral, pulmonary or tricuspid valve
- Patient has had previous implant and then explant of the Model 400 aortic valve bioprosthesis
- Patient presents with active endocarditis, active myocarditis or other systemic infection
- Patient has an anatomical abnormality which would increase surgical risk of morbidity or mortality, including:
- Ascending aortic aneurysm or dissection repair requiring circulatory arrest
- Acute Type A aortic dissection
Show all 26Show fewer
- Ventricular aneurysm
- Porcelain aorta
- Hostile mediastinum
- Hypertrophic obstructive cardiomyopathy (HOCM)
- Documented pulmonary hypertension (systolic >60mmHg)
- Patient has a non-cardiac major or progressive disease, with a life expectancy of less than 2 years. These conditions include, but are not limited to:
- Child-Pugh Class C liver disease
- Terminal cancer
- End-stage lung disease
- Patient has renal failure, defined as dialysis therapy or glomerular filtration rate(GFR)<30 mL/min/1.73 m2
- Patient has hyperparathyroidism
- Patient is participating in another investigational device or drug trial or observational competitive study
- Patient is pregnant, lactating or planning to become pregnant during the trial period
- Patient has a documented history of substance (drug or alcohol) abuse
- Patient has greater than mild mitral valve regurgitation or greater than mild tricuspid valve regurgitation as assessed by echocardiography
- Patient has systolic ejection fraction (EF)<20% as assessed by echocardiography
- Patient has Grade IV Diastolic Dysfunction
- Patient has documented bleeding diatheses
- Patient has had an acute preoperative neurological deficit or myocardial infarction and has not returned to baseline or stabilized ≥30 days prior to enrollment
- Patient requires emergency surgery
Trial locations and contacts
38 sites in 8 countries.
38 sites in 8 countries
United States20 sites
University of Michigan Cardiovascular Center
Ann Arbor, Michigan, 48109-5853
Piedmont Hospital
Atlanta, Georgia, 30309
University of Colorado Hospital
Aurora, Colorado, 80045-2545
Cardiothoracic and Vascular Surgeons (CTVS)
Austin, Texas, 78756-4080
University of Maryland Medical Center
Baltimore, Maryland, 21201
Massachusetts General Hospital
Boston, Massachusetts, 02114
Maimonides Medical Center
Brooklyn, New York, 11219
Cleveland Clinic
Cleveland, Ohio, 44195-0001
Riverside Methodist Hospital (OhioHealth)
Columbus, Ohio, 43214
University of Florida Shands
Gainesville, Florida, 32610
Hartford Hospital
Hartford, Connecticut, 06102
Houston Methodist Hospital
Houston, Texas, 77030
University of Southern California (USC) University Hospital
Los Angeles, California, 90033-5313
Aurora Saint Luke's Medical Center
Milwaukee, Wisconsin, 53215-4330
Minneapolis Heart Institute Foundation
Minneapolis, Minnesota, 55407-1139
The Mount Sinai Medical Center
New York, New York, 10029
New York-Presbyterian Hospital/Columbia University Medical Center
New York, New York, 10032
Oklahoma Heart Hospital
Oklahoma City, Oklahoma, 73135
University of Washington Medical Center
Seattle, Washington, 98195-0001
ProMedica Toledo Hospital
Toledo, Ohio, 43606
Canada5 sites
London Health Sciences Centre - University Campus
London, Ontario, N6A 5A5
Montreal Heart Institute
Montreal, Quebec, H1T 1C8
University of Ottawa Heart Institute
Ottawa, Ontario, K1Y 4W7
Institut Universitaire de Cardiologie et de Pneumologie de Québec (IUCPQ)
Québec, G1V 4G5
Toronto General Hospital
Toronto, M5G 2C4
Germany5 sites
Uniklinik Köln
Cologne, Köln, 50924
Universitäts Klinikum Frankfurt - Goethe-Universität
Frankfurt, 60590
Medizinische Hochschule Hannover
Hanover, 30625
Herzzentrum Leipzig GmbH
Leipzig, 04289
Deutsches Herzzentrum München
Munich, München, DE 80636
France2 sites
Hôpital Cardiologique du Haut-Lévêque
Bordeaux, 33604
Hôpital Bichat - Claude Bernard
Paris, 75018
Netherlands2 sites
Leids Universitair Medisch Centrum (LUMC)
Leiden, 2333 ZA
Erasmus MC
Rotterdam, 3015 CE
Switzerland2 sites
Inselspital - Universitätsspital Bern
Bern, 3010
UniversitätsSpital Zürich
Zurich, 8091
United Kingdom1 site
Guy's & St Thomas' NHS Foundation Trust - St Thomas' Hospital
London, SE1 7EH
About this study
Official title: Medtronic PERIcardial SurGical AOrtic Valve ReplacemeNt Pivotal Trial A Multi-center, Non-randomized Trial to Determine the Safety and Effectiveness of the Model 400 Aortic Valve Bioprosthesis in Patients With Aortic Valve Disease
To evaluate the safety and effectiveness of the Model 400 aortic valve bioprosthesis.
Read the detailed description
This is a prospective, interventional, non-randomized, worldwide, multi-center trial. A maximum of 1300 subjects were to be implanted at a maximum of 40 sites in the US, Europe and Canada. The trial includes male and female patients of legal age to provide informed consent in the country where they enrolled in the trial, requiring replacement for a diseased, damaged, or malfunctioning native or prosthetic aortic valve. Subjects are followed out to 5 years, and select sites follow subjects out to 12 years. Enrollment closed on 14Jul2017 for all valve sizes. Enrollment was reopened in Apr2019 for the 29mm valve size at a subset of US and Canadian sites to obtain greater patient numbers required by the FDA to support US commercial approval of this valve size. Enrollment for the 29mm valve size closed on 14Feb2023.
- Conditions
- Aortic Stenosis
- Being tested
- Model 400 aortic valve bioprosthesis
- Medical subject headings
- Aortic Valve Stenosis
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Model 400 aortic valve bioprosthesisDevice
| Study group | Role | What they receive |
|---|---|---|
| Model 400 aortic valve bioprosthesis | Experimental | Not described Receives: Device: Model 400 aortic valve bioprosthesis |
What is being measured
The primary outcome is the main question the study is designed to answer.
Evaluate the Safety of the Model 400 Avalus Valve With Regard to Valve-related Adverse Events and Death at 1 Year Post-implant
Safety of the valve is evaluated by the time-related incidence of valve-related adverse events and death. The following valve-related adverse events are evaluated in this study: Thromboembolism, Thrombosis, Hemorrhage, Paravalvular leak (PVL), Endocarditis, Hemolysis, Structural valve deterioration, Non-structural dysfunction, Reintervention, Explant, and Death. A minimum of 15 participants per valve size are evaluated. The incidence rates will be used to summarize valve-related adverse events and death.
Measured: 1 year post-implant
Confirm the Effectiveness of the Model 400 Avalus Valve With Regard to the Change of New York Heart Association (NYHA) Classification From Baseline Through 1 Year
At each timepoint, a minimum of 15 participants per valve size evaluated for change in New York Heart Association (NYHA) functional classification from baseline to 1 year post-procedure.
Measure Description: Cardiac Disease with Functional Classes (lower value is more desirable than higher value) I - No limitation of physical activity. Ordinary physical activity does not cause undue fatigue, palpitation or shortness of breath.
II - Slight limitation of physical activity. Comfortable at rest. Ordinary physical activity results in fatigue, palpitation, shortness of breath or chest pain.
III - Marked limitation of physical activity. Comfortable at rest. Less than ordinary activity causes fatigue, palpitation, shortness of breath or chest pain.
IV - Symptoms of heart failure at rest. Any physical activity causes further discomfort.
Measured: Discharge (up to 30 days), 3-6 months, and 1 year post-implant
Confirm the Effectiveness of the Model 400 Avalus Valve With Regard to Effective Orifice Area Through 1 Year Post-procedure
A minimum of 15 participants per valve size evaluated by transthoracic echocardiography technique and assessed by an independent core laboratory. The effective orifice area (EOA) is measured as the minimal cross-sectional area of the blood flow downstream of the aortic valve.
Measured: Discharge (up to 30 days), 3-6 months, 1 year post-implant
Confirm the Effectiveness of the Model 400 Avalus Valve With Regard to the Effective Orifice Area Index (EOAI) Through 1 Year Post-implant
A minimum of 15 participants per valve size evaluated by transthoracic echocardiography technique and assessed by an independent core laboratory for effective orifice area index (EOAI = EOA/BSA) Effective orifice area index is equal to the effective orifice area (EOA) in cm^2 divided by body surface area (BSA) in m^2.
The achievement criterion for the effective orifice area index (EOAI) is defined to be ≥0.6 cm^2/m^2 12 months after the procedure. This criterion is in accordance with the definition of severe aortic stenosis in the American College of Cardiology (ACC) / American Heart Association (AHA) guidelines for the management of valvular heart disease.
Measured: Discharge (up to 30 days), 3-6 months, and 1 year post-implant
Confirm the Effectiveness of the Model 400 Avalus Valve With Regard to the Peak Pressure Gradient (mmHg) From Discharge up to 1 Year
A minimum of 15 participants per valve size evaluated by transthoracic echocardiography technique and assessed by an independent core laboratory.
The peak pressure gradient is the maximum value measured of flow of blood through the aortic valve as measured in millimeters of mercury.
Measured: Measured at discharge (up to 30 days), 3-6 months, and 1 year post-implant
Confirm the Effectiveness of the Model 400 Avalus Valve With Regard to Mean Pressure Gradient (mmHg) Through 1 Year Post-implant
A minimum of 15 participants per valve size evaluated by transthoracic echocardiography technique and will be assessed by an independent core laboratory. The mean pressure gradient is the average flow of blood through the aortic valve measured in millimeters of mercury.
Measured: Discharge (up to 30 days), 3-6 months, and 1 year post-implant
Confirm the Effectiveness of the Model 400 Avalus Valve With Regard to Performance Index (L/Min) Through 1 Year Post-implant
A minimum of 15 participants per valve size will have performance index (L/Min) measured by transthoracic echocardiography technique and will be assessed by an independent core laboratory. The performance index is the measurement of the effective orifice area divided by the native orifice area.
Measured: Discharge (up to 30 days), 3-6 months, and 1 year post-implant
Confirm the Effectiveness of the Model 400 Avalus Valve With Regard to Cardiac Output (L/Min) Through 1 Year Post-implant
Cardiac output is the amount of blood pumped by the heart per minute. A minimum of 15 participants per valve size were evaluated for this outcome measure by transthoracic echocardiography technique and assessed by an independent core laboratory.
Measured: Discharge (up to 30 days), 3-6 months, and 1 year post-implant
Confirm the Effectiveness of the Model 400 Avalus Valve With Regard to Cardiac Index (L/Min/m^2) Through 1 Year Post-implant
A minimum of 15 participants per valve size evaluated by transthoracic echocardiography technique and will be assessed by an independent core laboratory.
The cardiac index is an assessment of the cardiac output based on a patient's size measured by dividing the cardiac output by the patient's body's surface area.
Measured: Discharge (up to 30 days), 3-6 months, and 1 year post-implant
Secondary outcomes (9)
Evaluate the Safety of the Model 400 Avalus Valve With Regard to Valve-related Adverse Events and Death Annually Through 5 Years Post-implant
Safety of the valve is evaluated by the time-related incidence of valve-related adverse events and death. The following valve-related adverse events are evaluated in this study: Thromboembolism, Thrombosis, Hemorrhage, Paravalvular leak (PVL), Endocarditis, Hemolysis, Structural valve deterioration, Non-structural dysfunction, Reintervention, Explant, and Death. The Kaplan-Meier event rates will be used to summarize valve-related adverse events and death. The Kaplan-Meier rate and the corresponding 95% confidence interval will be presented for each visit interval.
Measured: Annually, at years 2, 3, 4, and 5 post-implant
Confirm the Effectiveness of the Model 400 Avalus Valve With Regard to the Change of New York Heart Association (NYHA) Classification From Baseline Through 5 Years Post-implant
At each timepoint, participants were evaluated for change in New York Heart Association (NYHA) functional classification from baseline through 5 years post-procedure.
Measure Description: Cardiac Disease with Functional Classes (lower value is more desirable than higher value) I - No limitation of physical activity. Ordinary physical activity does not cause undue fatigue, palpitation or shortness of breath.
II - Slight limitation of physical activity. Comfortable at rest. Ordinary physical activity results in fatigue, palpitation, shortness of breath or chest pain.
III - Marked limitation of physical activity. Comfortable at rest. Less than ordinary activity causes fatigue, palpitation, shortness of breath or chest pain.
IV - Symptoms of heart failure at rest. Any physical activity causes further discomfort.
Measured: Annually, at years 2, 3, 4, and 5 post-implant
Confirm the Effectiveness of the Model 400 Avalus Valve With Regard to Effective Orifice Area Through 5 Years Post-procedure
Evaluated by transthoracic echocardiography technique and assessed by an independent core laboratory. The effective orifice area (EOA) is measured as the minimal cross-sectional area of the blood flow downstream of the aortic valve.
Measured: Annually, at years 2, 3, 4, and 5 post-implant
Confirm the Effectiveness of the Model 400 Avalus Valve With Regard to the Effective Orifice Area Index (EOAI) Through 5 Years Post-implant
Evaluated by transthoracic echocardiography technique and assessed by an independent core laboratory for effective orifice area index (EOAI = EOA/BSA) Effective orifice area index is equal to the effective orifice area (EOA) in cm^2 divided by body surface area (BSA) in m^2.
The achievement criterion for the effective orifice area index (EOAI) is defined to be ≥0.6 cm^2/m^2 12 months after the procedure. This criterion is in accordance with the definition of severe aortic stenosis in the American College of Cardiology (ACC) / American Heart Association (AHA) guidelines for the management of valvular heart disease.
Measured: Annually, at years 2, 3, 4, and 5 post-implant
Confirm the Effectiveness of the Model 400 Avalus Valve With Regard to the Peak Pressure Gradient (mmHg) From Discharge up to 5 Years Post-implant
Evaluated by transthoracic echocardiography technique and assessed by an independent core laboratory.
The peak pressure gradient is the maximum value measured of flow of blood through the aortic valve as measured in millimeters of mercury.
Measured: Annually, at years 2, 3, 4, and 5 post-implant
Confirm the Effectiveness of the Model 400 Avalus Valve With Regard to Mean Pressure Gradient (mmHg) Through 5 Years Post-implant
Evaluated by transthoracic echocardiography technique and will be assessed by an independent core laboratory. The mean pressure gradient is the average flow of blood through the aortic valve measured in millimeters of mercury.
Measured: Annually, at years 2, 3, 4, and 5 post-implant
Confirm the Effectiveness of the Model 400 Avalus Valve With Regard to Performance Index (L/Min) Through 5 Years Post-implant
Performance index (L/Min) measured by transthoracic echocardiography technique and will be assessed by an independent core laboratory. The performance index is the measurement of the effective orifice area divided by the native orifice area.
Measured: Annually, at years 2, 3, 4, and 5 post-implant
Confirm the Effectiveness of the Model 400 Avalus Valve With Regard to Cardiac Output (L/Min) Through 5 Years Post-implant
Cardiac output is the amount of blood pumped by the heart per minute, evaluated by transthoracic echocardiography technique and assessed by an independent core laboratory.
Measured: Annually, at years 2, 3, 4, and 5 post-implant
Confirm the Effectiveness of the Model 400 Avalus Valve With Regard to Cardiac Index (L/Min/m^2) Through 5 Years Post-implant
Evaluated by transthoracic echocardiography technique and will be assessed by an independent core laboratory.
The cardiac index is an assessment of the cardiac output based on a patient's size measured by dividing the cardiac output by the patient's body's surface area.
Measured: Annually, at years 2, 3, 4, and 5 post-implant
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted17 Mar 2014 (estimated)
- Study start12 May 2014
- Primary completion17 Apr 2023
- Study completion31 Dec 2035 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Posted resultsParticipant flow, outcome measures and adverse events reported by the sponsor.
- Publications (4)Papers the sponsor has linked to this study.
- Other trials for Aortic StenosisStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 1,312 participants (actual)
Sponsor and investigators
- Lead sponsor
- Medtronic Cardiac Surgery
- Sponsor type
- Industry (pharma, biotech, devices)
- Collaborators
- Medtronic
- Responsible party
- Sponsor
- Investigators
- Joseph Sabik, MD, Principal investigator, University Hospital Cleveland Medical Center (Not a recruiting site)Prof. Dr. Robert Johannes Menno Klautz, MD, Principal investigator, Leiden University Medical Center
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT02088554
- Sponsor's protocol ID
- PERIGON
- Acronym
- PERIGON
- Status last verified
- Apr 2026
- First submitted
- 4 Mar 2014
- Last updated
- 29 Apr 2026
- Results posted
- Yes, on ClinicalTrials.gov
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
Publications
Velders BJJ, Vriesendorp MD, Weissman NJ, Sabik JF 3rd, Reardon MJ, Dagenais F, Moront MG, Rao V, Fukuhara S, Gunzinger R, van Leeuwen WJ, Brown WM, Groenwold RHH, Klautz RJM, Asch FM. Core Laboratory Versus Center-Reported Echocardiographic Assessment of the Native and Bioprosthetic Aortic Valve. Echocardiography. 2024 Dec;41(12):e70047. doi: 10.1111/echo.70047.
PubMed 39624936Klautz RJM, Rao V, Reardon MJ, Deeb GM, Dagenais F, Moront MG, Little SH, Labrousse L, Patel HJ, Ito S, Li S, Sabik JF 3rd, Oh JK. Examining the typical hemodynamic performance of nearly 3000 modern surgical aortic bioprostheses. Eur J Cardiothorac Surg. 2024 May 3;65(5):ezae122. doi: 10.1093/ejcts/ezae122.
PubMed 38710669Velders BJJ, Vriesendorp MD, De Lind Van Wijngaarden RAF, Rao V, Reardon MJ, Shrestha M, Chu MWA, Sabik JF 3rd, Liu F, Klautz RJM. Perioperative care differences of surgical aortic valve replacement between North America and Europe. Heart. 2023 Jun 26;109(14):1106-1112. doi: 10.1136/heartjnl-2023-322350.
PubMed 36963820Klautz RJM, Kappetein AP, Lange R, Dagenais F, Labrousse L, Bapat V, Moront M, Misfeld M, Zeng C, Sabik Iii JF; PERIGON Investigators. Safety, effectiveness and haemodynamic performance of a new stented aortic valve bioprosthesis. Eur J Cardiothorac Surg. 2017 Sep 1;52(3):425-431. doi: 10.1093/ejcts/ezx066.
PubMed 28475690
Study at a glance
From the registry record, last updated by the sponsor on 29 Apr 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Medtronic PERIcardial SurGical AOrtic Valve ReplacemeNt Pivotal Trial A Multi-center, Non-randomized Trial to Determine the Safety and Effectiveness of the Model 400 Aortic Valve Bioprosthesis in Patients With Aortic Valve Disease
- ClinicalTrials.gov ID
- NCT02088554
- Acronym / sponsor ID
- PERIGON / PERIGON
- Conditions
- Aortic Stenosis
- Study type
- Interventional
- Recruitment status
- Active, not recruiting
- Enrolment
- 1,312 participants (actual)
- Lead sponsor
- Medtronic Cardiac SurgeryIndustry (pharma, biotech, devices)
- Collaborators
- Medtronic
- Study start
- 12 May 2014 (actual)
- Primary completion
- 17 Apr 2023 (actual)
- Study completion
- 31 Dec 2035 (estimated)
- First posted
- 17 Mar 2014 (estimated)
- Results
- Posted 4 Jun 2024
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
To evaluate the safety and effectiveness of the Model 400 aortic valve bioprosthesis.
Detailed description
This is a prospective, interventional, non-randomized, worldwide, multi-center trial. A maximum of 1300 subjects were to be implanted at a maximum of 40 sites in the US, Europe and Canada. The trial includes male and female patients of legal age to provide informed consent in the country where they enrolled in the trial, requiring replacement for a diseased, damaged, or malfunctioning native or prosthetic aortic valve. Subjects are followed out to 5 years, and select sites follow subjects out to 12 years. Enrollment closed on 14Jul2017 for all valve sizes. Enrollment was reopened in Apr2019 for the 29mm valve size at a subset of US and Canadian sites to obtain greater patient numbers required by the FDA to support US commercial approval of this valve size. Enrollment for the 29mm valve size closed on 14Feb2023.
Study design
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Model 400 aortic valve bioprosthesis | Experimental | Device: Model 400 aortic valve bioprosthesis |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (5 listed)
- Patient has moderate or greater aortic stenosis or regurgitation, and there is clinical indication for replacement of their native or prosthetic aortic valve with a bioprosthesis, with or without concomitant procedures, which are limited to any of the following:
- Patient is geographically stable and willing to return to the implanting site for all follow-up visits
- Patient is of legal age to provide informed consent in the country where they enroll in the trial
- Patient has been adequately informed of risks and requirements of the trial and is willing and able to provide informed consent for participation in the clinical trial
Key exclusion criteria (26 listed)
- Patient has a pre-existing prosthetic valve or annuloplasty device in another position or requires replacement or repair of the mitral, pulmonary or tricuspid valve
- Patient has had previous implant and then explant of the Model 400 aortic valve bioprosthesis
- Patient presents with active endocarditis, active myocarditis or other systemic infection
- Patient has an anatomical abnormality which would increase surgical risk of morbidity or mortality, including:
- Patient has a non-cardiac major or progressive disease, with a life expectancy of less than 2 years. These conditions include, but are not limited to:
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Model 400 aortic valve bioprosthesis | Device | Model 400 aortic valve bioprosthesis |
Primary outcome
Evaluate the Safety of the Model 400 Avalus Valve With Regard to Valve-related Adverse Events and Death at 1 Year Post-implant
Time frame: 1 year post-implant
Safety of the valve is evaluated by the time-related incidence of valve-related adverse events and death. The following valve-related adverse events are evaluated in this study: Thromboembolism, Thrombosis, Hemorrhage, Paravalvular leak (PVL), Endocarditis, Hemolysis, Structural valve deterioration, Non-structural dysfunction, Reintervention, Explant, and Death. A minimum of 15 participants per valve size are evaluated. The incidence rates will be used to summarize valve-related adverse events and death.
Confirm the Effectiveness of the Model 400 Avalus Valve With Regard to the Change of New York Heart Association (NYHA) Classification From Baseline Through 1 Year
Time frame: Discharge (up to 30 days), 3-6 months, and 1 year post-implant
At each timepoint, a minimum of 15 participants per valve size evaluated for change in New York Heart Association (NYHA) functional classification from baseline to 1 year post-procedure. Measure Description: Cardiac Disease with Functional Classes (lower value is more desirable than higher value) I - No limitation of physical activity. Ordinary physical activity does not cause undue fatigue, palpitation or shortness of breath. II - Slight limitation of physical activity. Comfortable at rest. Ordinary physical activity results in fatigue, palpitation, shortness of breath or chest pain. III - Marked limitation of physical activity. Comfortable at rest. Less than ordinary activity causes fatigue, palpitation, shortness of breath or chest pain. IV - Symptoms of heart failure at rest. Any physical activity causes further discomfort.
Confirm the Effectiveness of the Model 400 Avalus Valve With Regard to Effective Orifice Area Through 1 Year Post-procedure
Time frame: Discharge (up to 30 days), 3-6 months, 1 year post-implant
A minimum of 15 participants per valve size evaluated by transthoracic echocardiography technique and assessed by an independent core laboratory. The effective orifice area (EOA) is measured as the minimal cross-sectional area of the blood flow downstream of the aortic valve.
Confirm the Effectiveness of the Model 400 Avalus Valve With Regard to the Effective Orifice Area Index (EOAI) Through 1 Year Post-implant
Time frame: Discharge (up to 30 days), 3-6 months, and 1 year post-implant
A minimum of 15 participants per valve size evaluated by transthoracic echocardiography technique and assessed by an independent core laboratory for effective orifice area index (EOAI = EOA/BSA) Effective orifice area index is equal to the effective orifice area (EOA) in cm^2 divided by body surface area (BSA) in m^2. The achievement criterion for the effective orifice area index (EOAI) is defined to be ≥0.6 cm^2/m^2 12 months after the procedure. This criterion is in accordance with the definition of severe aortic stenosis in the American College of Cardiology (ACC) / American Heart Association (AHA) guidelines for the management of valvular heart disease.
Confirm the Effectiveness of the Model 400 Avalus Valve With Regard to the Peak Pressure Gradient (mmHg) From Discharge up to 1 Year
Time frame: Measured at discharge (up to 30 days), 3-6 months, and 1 year post-implant
A minimum of 15 participants per valve size evaluated by transthoracic echocardiography technique and assessed by an independent core laboratory. The peak pressure gradient is the maximum value measured of flow of blood through the aortic valve as measured in millimeters of mercury.
Confirm the Effectiveness of the Model 400 Avalus Valve With Regard to Mean Pressure Gradient (mmHg) Through 1 Year Post-implant
Time frame: Discharge (up to 30 days), 3-6 months, and 1 year post-implant
A minimum of 15 participants per valve size evaluated by transthoracic echocardiography technique and will be assessed by an independent core laboratory. The mean pressure gradient is the average flow of blood through the aortic valve measured in millimeters of mercury.
Confirm the Effectiveness of the Model 400 Avalus Valve With Regard to Performance Index (L/Min) Through 1 Year Post-implant
Time frame: Discharge (up to 30 days), 3-6 months, and 1 year post-implant
A minimum of 15 participants per valve size will have performance index (L/Min) measured by transthoracic echocardiography technique and will be assessed by an independent core laboratory. The performance index is the measurement of the effective orifice area divided by the native orifice area.
Confirm the Effectiveness of the Model 400 Avalus Valve With Regard to Cardiac Output (L/Min) Through 1 Year Post-implant
Time frame: Discharge (up to 30 days), 3-6 months, and 1 year post-implant
Cardiac output is the amount of blood pumped by the heart per minute. A minimum of 15 participants per valve size were evaluated for this outcome measure by transthoracic echocardiography technique and assessed by an independent core laboratory.
Confirm the Effectiveness of the Model 400 Avalus Valve With Regard to Cardiac Index (L/Min/m^2) Through 1 Year Post-implant
Time frame: Discharge (up to 30 days), 3-6 months, and 1 year post-implant
A minimum of 15 participants per valve size evaluated by transthoracic echocardiography technique and will be assessed by an independent core laboratory. The cardiac index is an assessment of the cardiac output based on a patient's size measured by dividing the cardiac output by the patient's body's surface area.
9 secondary outcomes
Evaluate the Safety of the Model 400 Avalus Valve With Regard to Valve-related Adverse Events and Death Annually Through 5 Years Post-implant
Time frame: Annually, at years 2, 3, 4, and 5 post-implant
Confirm the Effectiveness of the Model 400 Avalus Valve With Regard to the Change of New York Heart Association (NYHA) Classification From Baseline Through 5 Years Post-implant
Time frame: Annually, at years 2, 3, 4, and 5 post-implant
Confirm the Effectiveness of the Model 400 Avalus Valve With Regard to Effective Orifice Area Through 5 Years Post-procedure
Time frame: Annually, at years 2, 3, 4, and 5 post-implant
Confirm the Effectiveness of the Model 400 Avalus Valve With Regard to the Effective Orifice Area Index (EOAI) Through 5 Years Post-implant
Time frame: Annually, at years 2, 3, 4, and 5 post-implant
Confirm the Effectiveness of the Model 400 Avalus Valve With Regard to the Peak Pressure Gradient (mmHg) From Discharge up to 5 Years Post-implant
Time frame: Annually, at years 2, 3, 4, and 5 post-implant
Confirm the Effectiveness of the Model 400 Avalus Valve With Regard to Mean Pressure Gradient (mmHg) Through 5 Years Post-implant
Time frame: Annually, at years 2, 3, 4, and 5 post-implant
Confirm the Effectiveness of the Model 400 Avalus Valve With Regard to Performance Index (L/Min) Through 5 Years Post-implant
Time frame: Annually, at years 2, 3, 4, and 5 post-implant
Confirm the Effectiveness of the Model 400 Avalus Valve With Regard to Cardiac Output (L/Min) Through 5 Years Post-implant
Time frame: Annually, at years 2, 3, 4, and 5 post-implant
Confirm the Effectiveness of the Model 400 Avalus Valve With Regard to Cardiac Index (L/Min/m^2) Through 5 Years Post-implant
Time frame: Annually, at years 2, 3, 4, and 5 post-implant
Results and safety
Loading the posted results from ClinicalTrials.gov…
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 29 Apr 2026.
- Posted resultsParticipant flow, baseline, all outcome measures and adverse events.
- Derived from this study: PubMed 39624936Velders BJJ, Vriesendorp MD, Weissman NJ, Sabik JF 3rd, Reardon MJ, Dagenais F, Moront MG, Rao V, Fukuhara S, Gunzinger R, van Leeuwen WJ, Brown WM, Groenwold RHH, Klautz RJM, Asch FM. Core Laboratory Versus Center-Reported Echocardiographic Assessment of the Native and Bioprosthetic Aortic Valve. Echocardiography. 2024 Dec;41(12):e70047. doi: 10.1111/echo.70047.
- Derived from this study: PubMed 38710669Klautz RJM, Rao V, Reardon MJ, Deeb GM, Dagenais F, Moront MG, Little SH, Labrousse L, Patel HJ, Ito S, Li S, Sabik JF 3rd, Oh JK. Examining the typical hemodynamic performance of nearly 3000 modern surgical aortic bioprostheses. Eur J Cardiothorac Surg. 2024 May 3;65(5):ezae122. doi: 10.1093/ejcts/ezae122.
- Derived from this study: PubMed 36963820Velders BJJ, Vriesendorp MD, De Lind Van Wijngaarden RAF, Rao V, Reardon MJ, Shrestha M, Chu MWA, Sabik JF 3rd, Liu F, Klautz RJM. Perioperative care differences of surgical aortic valve replacement between North America and Europe. Heart. 2023 Jun 26;109(14):1106-1112. doi: 10.1136/heartjnl-2023-322350.
- Derived from this study: PubMed 28475690Klautz RJM, Kappetein AP, Lange R, Dagenais F, Labrousse L, Bapat V, Moront M, Misfeld M, Zeng C, Sabik Iii JF; PERIGON Investigators. Safety, effectiveness and haemodynamic performance of a new stented aortic valve bioprosthesis. Eur J Cardiothorac Surg. 2017 Sep 1;52(3):425-431. doi: 10.1093/ejcts/ezx066.
Related trials for Aortic Stenosis
Active, not recruitingObservational study
REdo Transcatheter Aortic VALVE Implantation for the Management of Transcatheter Aortic Valve Failure
Aortic Valve Stenosis
Not yet recruiting
NHLBI SESAME (SEptal Scoring Along Midline Endocardium) Multi-Center Prospective Study Using Improvised Off-Label Devices
Hypertrophic Cardiomyopathy, Left Ventricular Outflow Obstruction
Not yet recruiting
Exercise and Diet Supplements for Older Patients Undergoing TAVI: the IRON-TAVI Trial
Aortic Stenosis Disease, Aortic Stenosis Symptomatic
Not yet recruiting
A Clinical Trial to Evaluate the Effects of the NeuEve Dryness Treatment Kit on Vaginal Health, Comfort, and Quality of Life in Postmenopausal Women
Relieves Vaginal Dryness / Improves Self-Lubrication, Improves Strength & Elasticity of Vagina (Aka Collagen and Elastin)
RecruitingPhase 2
A Trial to Evaluate the Efficacy and Safety of Ninerafaxstat in Patients With Symptomatic Non-obstructive Hypertrophic Cardiomyopathy
Non-obstructive Hypertrophic Cardiomyopathy
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Joseph Sabik, MD principal investigator
University Hospital Cleveland Medical Center (Not a recruiting site)
Prof. Dr. Robert Johannes Menno Klautz, MD principal investigator
Leiden University Medical Center
38 sites in 8 countries: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Model 400 aortic valve bioprosthesis in people with Aortic Stenosis, run by Medtronic Cardiac Surgery at 38 sites in 8 countries.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 5 inclusion and 26 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: under way, not looking for participants, as of the sponsor's last update on 29 Apr 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 38 sites in United States, Canada, Germany, France, Netherlands and 3 more countries. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Yes. Results are posted in the registry (first posted 4 Jun 2024). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Evaluate the Safety of the Model 400 Avalus Valve With Regard to Valve-related Adverse Events and Death at 1 Year Post-implant (time frame: 1 year post-implant). The study lists 9 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT02088554, which also lists 4 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 29 Apr 2026.