Ultrasound TrainingNCT01895868
Long-terms Effects of Simulation-based Ultrasound Training: A Randomized Trial
A study testing Simulation-based ultrasound training in people with Ultrasound Training and Ultrasound Simulation, run by Copenhagen University Hospital, Rigshospitalet at 1 site in Denmark.
Trial summary
The clinical effects of simulation-based ultrasound training has not yet been explored. To examine the long-term effects of training, we plan to conduct a trial, where half of all new residents are randomized to simulation-based training and the other half to traditional clinical training only. Read more about this study
- Who is it for?
- Any ageHealthy volunteers can take part
- Conditions the study is for
- Ultrasound Training, Ultrasound Simulation, Ultrasound Assessment
- What is being tested?
- Simulation-based ultrasound training
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 26 participants
- Where
- 1 siteDenmark
- Study dates
- Jul 2013to Apr 2014
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages Any age
- All sexes
- Healthy volunteers accepted
- Child, Adult, Older adult
Who may be able to join
- 1) proficiency in written and oral Danish, 2) informed written consent.
Who cannot join
- 1) prior employment at an OB/GYN department in a clinical position, 2) any formal ultrasound training with or without hands-on practice and (3) prior experience with virtual reality simulation.
Trial locations and contacts
1 site in 1 country.
About this study
The clinical effects of simulation-based ultrasound training has not yet been explored. To examine the long-term effects of training, we plan to conduct a trial, where half of all new residents are randomized to simulation-based training and the other half to traditional clinical training only. The effects are assessed after two months of practice by evaluating two ultrasound scans performed by the residents. These scans are subsequently evaluated by a blinded consultant gynecologist and rated using the Objective Structured Assessment of Ultrasound Skills, which has been validated in previous studies.
Read the detailed description
Ultrasonography has become increasingly used in many medical specialties over the last decades as smaller and less expensive ultrasound equipment has become available. Although ultrasound imaging traditionally is considered safe, its use is highly operator dependent (EFSUMB 2010). The lack of sufficient operator skills can lead to diagnostic errors that eventually compromise patient safety due to unnecessary tests or interventions (Moore \& Copel 2011). Clinical ultrasound training is challenged with long learning curves and is therefore both time consuming and requires large teacher resources (Jang et al. 2010). Some trainees may therefore never acquire the basic skills and knowledge needed for independent practice (Tolsgaard et al. 2012). In the search for effective training methods, simulation-based training has proven to be an effective adjunct to clinical training, which has been documented in several studies on interventional procedures (Larsen et al. 2009, Zendejas et al 2011, Barsuk et al. 2009). Most comparative studies on simulation-based training have, however, only examined the initial effects of simulation-based training on the first couple of procedures, it is not known if VR simulation training provides sustained improvements trainee performance throughout their learning curves until they reach clinical proficiency. Large resources are currently being allocated to simulation training in many different specialties but the effects of simulation may easily be over-estimated if only evaluating the immediate effects of simulation training. A small difference in the number of supervised ultrasound examinations needed for proficiency may not justify the financial costs associated with investing in simulation equipment, space for simulation training as well as teacher resources during simulation training. Therefore, the research questions of this study was:
In a group of ultrasound novices, what are the implications of simulation-based training compared to clinical training alone on the technical quality of scans performed after two months of training?
Methods
Study design This study is reported according to the CONSORT statement (www.consort-statement.org). A randomized observer-blind study to compare VR ultrasound training with traditional supervised practice on subsequent patient scans (see Figure 1 for flowchart of study design). Ethical approval was obtained from the Regional Ethical Committee of the Capital Region, Denmark. The Danish Data Protection Agency approved the storing of patient relevant information. This randomized trial is reported to clinicaltrials.gov prior to inclusion of participants.
Setting This study is carried out at the Departments of Gynecology at the Juliane Marie Centre, Copenhagen University Hospital, Denmark, Næstved Hospital, and Hillerød Hospital.
Participants Participants are all new OB/GYN residents at three different hospitals in Eastern Denmark. Inclusion criteria are 1) proficiency in written and oral Danish, 2) informed written consent. The exclusion criteria are 1) prior employment at an OB/GYN department in a clinical position, 2) any formal ultrasound training with or without hands-on practice and (3) prior experience with virtual reality simulation.
Randomization A research fellow at The Center for Clinical Education, Rigshospitalet, independently performs randomisation of participants by computer to either intervention group (simulation training) or control group (clinical training only). The allocation of participants is concealed to the primary investigator during the enrolment of participants. Once informed consent has been signed and a participant number has been provided, the allocation sequence is retrieved per telephone.
Intervention Participants in the intervention group receive simulation training using two types of ultrasound simulators (see Figure 2 for flowchart of the simulation programme). Participants are introduced to a high-fidelity Virtual-Reality (VR) simulator (Scantrainer, Medaphor). The VR simulator provides images obtained from real patients and haptic feedback from the ultrasound probe. Participants train on this type of simulator until a predefined proficiency-level has been attained. The selection of modules is based on a previous validation study and only modules and items that discriminate between novice and expert performances are included in the training programme (Madsen et al. 2013). All participants are provided feedback after completing each module. When all modules are passed on the VR simulator, the participants receive proficiency-based training training on the low-fidelity simulator (BluePhantom) to allow participants to review the functions, they just trained, using real ultrasound equipment. The simulator performances are assessed using the Objective Structured Examination of Ultrasound Skills (OSAUS) and feedback is provided using this framework after each trial. Proficiency is set according pass/fail-scores established in a previous study (Tolsgaard et al. 2013).
Clinical training Participants in both groups receive traditional clinical training. This includes supervised practice in terms of apprenticeship learning followed by supervision during independent practice. The new residents do not usually go on calls for the first one to two weeks. Local department rules dictates which types of examinations that always requires a second examination by a supervising clinicians (e.g. fetal demise or pregnancy of unknown location).
Main outcome measure The main outcome measure is the technical proficiency after two months of practice. Two scans from the emergency department are recorded and subsequently assessed by a blinded clinician, who also had access to the ultrasound descriptions that corresponded to each scan. The assessments were performed using the Objective Structured Assessment of Ultrasound Skills (Tolsgaard et al. 2013), which has been validated in a construct validity study including 30 clinicians with different levels of experience prior to this trial.
Sample size calculation Sample size calculations are based on previous studies on clinical performances of ultrasound novices with the performance of medical students, who completed a simulation-based training programme (Tolsgaard et al. 2013). The average difference in OSAUS scores between these groups was 0.85 (2.65-1.8 (mean SD 0.4). It was anticipated that these differences would be diluted according to literature from other areas of simulation-based technical skills training (Smith et al. 2010), where simulation effects persisted after 3 months of training but the differences between groups was diminished to 55% of the initial effects. Assuming a 55% dilution, an alpha-level of 0.05 and a power of 0.80, the total number of participants needed was 26.
- Conditions
- Ultrasound Training, Ultrasound Simulation, Ultrasound Assessment, Technology-enhanced Learning, Virtual Reality Simulation
- Being tested
- Simulation-based ultrasound training
- Keywords
- Ultrasound training, Ultrasound simulation, Ultrasound assessment, Technology-enhanced learning, virtual reality simulation
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Simulation-based ultrasound trainingOther
Also called Scantrainer, Medaphor, BluePhantom, CAE
| Study group | Role | What they receive |
|---|---|---|
| Simulation-based training | Active comparator | Participants in the intervention group receive simulation training using two types of ultrasound simulators: The Scantrainer (Medaphor) and the BluePhantom (CAE). All participants are training to pre-established proficiency-criteria. Receives: Other: Simulation-based ultrasound training |
| Control | No intervention | Clinical training alone. |
What is being measured
The primary outcome is the main question the study is designed to answer.
Technical ultrasound performances
The main outcome measure is the technical proficiency after two months of practice. Two scans from the emergency department are recorded and subsequently assessed by a blinded clinician, who also had access to the ultrasound descriptions that corresponded to each scan. The assessments were performed using the Objective Structured Assessment of Ultrasound Skills (Tolsgaard et al. 2013), which has been validated in a construct validity study including 30 clinicians with different levels of experience prior to this trial.
Measured: 2 months
Secondary outcomes (1)
Diagnostic accuracy
Diagnostic accuracy is assessed using the previously described video recordings.
Measured: Two months
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted11 Jul 2013 (estimated)
- Study startJul 2013
- Primary completionApr 2014
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (1)Papers the sponsor has linked to this study.
- Other trials for Ultrasound TrainingStudies of the same condition, open and under way.
- More trials run by Copenhagen University Hospital, RigshospitaletThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Single blind
- Who is masked
- Outcomes assessor
- Enrolment
- 26 participants (actual)
Sponsor and investigators
- Lead sponsor
- Copenhagen University Hospital, Rigshospitalet
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Martin G. Tolsgaard, Copenhagen University Hospital, Rigshospitalet
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT01895868
- Sponsor's protocol ID
- H-3-2012-154
- Other IDs
- H-3-2012-154
- Status last verified
- Apr 2014
- First submitted
- 7 Jul 2013
- Last updated
- 7 Apr 2014
- Results posted
- No
- Data monitoring committee
- No
Publications
Tolsgaard MG, Ringsted C, Dreisler E, Norgaard LN, Petersen JH, Madsen ME, Freiesleben NL, Sorensen JL, Tabor A. Sustained effect of simulation-based ultrasound training on clinical performance: a randomized trial. Ultrasound Obstet Gynecol. 2015 Sep;46(3):312-8. doi: 10.1002/uog.14780. Epub 2015 Aug 6.
PubMed 25580809
Study at a glance
From the registry record, last updated by the sponsor on 7 Apr 2014. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Long-terms Effects of Simulation-based Ultrasound Training: A Randomized Trial
- ClinicalTrials.gov ID
- NCT01895868
- Acronym / sponsor ID
- H-3-2012-154
- Conditions
- Ultrasound Training, Ultrasound Simulation, Ultrasound Assessment, Technology-enhanced Learning, Virtual Reality Simulation
- Keywords
- Ultrasound training, Ultrasound simulation, Ultrasound assessment, Technology-enhanced learning, virtual reality simulation
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 26 participants (actual)
- Lead sponsor
- Copenhagen University Hospital, RigshospitaletUniversity, hospital or other
- Study start
- Jul 2013
- Primary completion
- Apr 2014 (actual)
- First posted
- 11 Jul 2013 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The clinical effects of simulation-based ultrasound training has not yet been explored. To examine the long-term effects of training, we plan to conduct a trial, where half of all new residents are randomized to simulation-based training and the other half to traditional clinical training only. The effects are assessed after two months of practice by evaluating two ultrasound scans performed by the residents. These scans are subsequently evaluated by a blinded consultant gynecologist and rated using the Objective Structured Assessment of Ultrasound Skills, which has been validated in previous studies.
Detailed description
Ultrasonography has become increasingly used in many medical specialties over the last decades as smaller and less expensive ultrasound equipment has become available. Although ultrasound imaging traditionally is considered safe, its use is highly operator dependent (EFSUMB 2010). The lack of sufficient operator skills can lead to diagnostic errors that eventually compromise patient safety due to unnecessary tests or interventions (Moore \& Copel 2011). Clinical ultrasound training is challenged with long learning curves and is therefore both time consuming and requires large teacher resources (Jang et al. 2010). Some trainees may therefore never acquire the basic skills and knowledge needed for independent practice (Tolsgaard et al. 2012). In the search for effective training methods, simulation-based training has proven to be an effective adjunct to clinical training, which has been documented in several studies on interventional procedures (Larsen et al. 2009, Zendejas et al 2011, Barsuk et al. 2009). Most comparative studies on simulation-based training have, however, only examined the initial effects of simulation-based training on the first couple of procedures, it is not known if VR simulation training provides sustained improvements trainee performance throughout their learning curves until they reach clinical proficiency. Large resources are currently being allocated to simulation training in many different specialties but the effects of simulation may easily be over-estimated if only evaluating the immediate effects of simulation training. A small difference in the number of supervised ultrasound examinations needed for proficiency may not justify the financial costs associated with investing in simulation equipment, space for simulation training as well as teacher resources during simulation training. Therefore, the research questions of this study was:
In a group of ultrasound novices, what are the implications of simulation-based training compared to clinical training alone on the technical quality of scans performed after two months of training?
Methods
Study design This study is reported according to the CONSORT statement (www.consort-statement.org). A randomized observer-blind study to compare VR ultrasound training with traditional supervised practice on subsequent patient scans (see Figure 1 for flowchart of study design). Ethical approval was obtained from the Regional Ethical Committee of the Capital Region, Denmark. The Danish Data Protection Agency approved the storing of patient relevant information. This randomized trial is reported to clinicaltrials.gov prior to inclusion of participants.
Setting This study is carried out at the Departments of Gynecology at the Juliane Marie Centre, Copenhagen University Hospital, Denmark, Næstved Hospital, and Hillerød Hospital.
Participants Participants are all new OB/GYN residents at three different hospitals in Eastern Denmark. Inclusion criteria are 1) proficiency in written and oral Danish, 2) informed written consent. The exclusion criteria are 1) prior employment at an OB/GYN department in a clinical position, 2) any formal ultrasound training with or without hands-on practice and (3) prior experience with virtual reality simulation.
Randomization A research fellow at The Center for Clinical Education, Rigshospitalet, independently performs randomisation of participants by computer to either intervention group (simulation training) or control group (clinical training only). The allocation of participants is concealed to the primary investigator during the enrolment of participants. Once informed consent has been signed and a participant number has been provided, the allocation sequence is retrieved per telephone.
Intervention Participants in the intervention group receive simulation training using two types of ultrasound simulators (see Figure 2 for flowchart of the simulation programme). Participants are introduced to a high-fidelity Virtual-Reality (VR) simulator (Scantrainer, Medaphor). The VR simulator provides images obtained from real patients and haptic feedback from the ultrasound probe. Participants train on this type of simulator until a predefined proficiency-level has been attained. The selection of modules is based on a previous validation study and only modules and items that discriminate between novice and expert performances are included in the training programme (Madsen et al. 2013). All participants are provided feedback after completing each module. When all modules are passed on the VR simulator, the participants receive proficiency-based training training on the low-fidelity simulator (BluePhantom) to allow participants to review the functions, they just trained, using real ultrasound equipment. The simulator performances are assessed using the Objective Structured Examination of Ultrasound Skills (OSAUS) and feedback is provided using this framework after each trial. Proficiency is set according pass/fail-scores established in a previous study (Tolsgaard et al. 2013).
Clinical training Participants in both groups receive traditional clinical training. This includes supervised practice in terms of apprenticeship learning followed by supervision during independent practice. The new residents do not usually go on calls for the first one to two weeks. Local department rules dictates which types of examinations that always requires a second examination by a supervising clinicians (e.g. fetal demise or pregnancy of unknown location).
Main outcome measure The main outcome measure is the technical proficiency after two months of practice. Two scans from the emergency department are recorded and subsequently assessed by a blinded clinician, who also had access to the ultrasound descriptions that corresponded to each scan. The assessments were performed using the Objective Structured Assessment of Ultrasound Skills (Tolsgaard et al. 2013), which has been validated in a construct validity study including 30 clinicians with different levels of experience prior to this trial.
Sample size calculation Sample size calculations are based on previous studies on clinical performances of ultrasound novices with the performance of medical students, who completed a simulation-based training programme (Tolsgaard et al. 2013). The average difference in OSAUS scores between these groups was 0.85 (2.65-1.8 (mean SD 0.4). It was anticipated that these differences would be diluted according to literature from other areas of simulation-based technical skills training (Smith et al. 2010), where simulation effects persisted after 3 months of training but the differences between groups was diminished to 55% of the initial effects. Assuming a 55% dilution, an alpha-level of 0.05 and a power of 0.80, the total number of participants needed was 26.
Study design
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Single blind (outcomes assessor)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| Simulation-based training | Active comparator | Other: Simulation-based ultrasound trainingParticipants in the intervention group receive simulation training using two types of ultrasound simulators: The Scantrainer (Medaphor) and the BluePhantom (CAE). All participants are training to pre-established proficiency-criteria. |
| Control | No intervention | –Clinical training alone. |
Who may qualify
- Sex
- All
- Healthy volunteers
- Accepted
- Age groups
- Child, Adult, Older adult
Key inclusion criteria (1 listed)
- 1) proficiency in written and oral Danish, 2) informed written consent.
Key exclusion criteria (1 listed)
- 1) prior employment at an OB/GYN department in a clinical position, 2) any formal ultrasound training with or without hands-on practice and (3) prior experience with virtual reality simulation.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Simulation-based ultrasound trainingAlso: Scantrainer, Medaphor, BluePhantom, CAE | Other | Simulation-based training |
Primary outcome
Technical ultrasound performances
Time frame: 2 months
The main outcome measure is the technical proficiency after two months of practice. Two scans from the emergency department are recorded and subsequently assessed by a blinded clinician, who also had access to the ultrasound descriptions that corresponded to each scan. The assessments were performed using the Objective Structured Assessment of Ultrasound Skills (Tolsgaard et al. 2013), which has been validated in a construct validity study including 30 clinicians with different levels of experience prior to this trial.
1 secondary outcome
Diagnostic accuracy
Time frame: Two months
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 7 Apr 2014.
- Derived from this study: PubMed 25580809Tolsgaard MG, Ringsted C, Dreisler E, Norgaard LN, Petersen JH, Madsen ME, Freiesleben NL, Sorensen JL, Tabor A. Sustained effect of simulation-based ultrasound training on clinical performance: a randomized trial. Ultrasound Obstet Gynecol. 2015 Sep;46(3):312-8. doi: 10.1002/uog.14780. Epub 2015 Aug 6.
Related trials for Ultrasound Training
Recruiting
Resistance Exercise With Blood Flow Restriction by Vascular Occlusion on Myocardial Function in Heart Failure With Reduced Ejection Fraction
Heart Failure, Ventricular Function, Left
Recruiting
Functional Electrical Stimulation Combined With Exercise for Rotator Cuff-Related Shoulder Pain in Older Adults
Rotator Cuff Disease, Subacromial Pain Syndrome
Recruiting
Diaphragm Training Ultrasound
DIAPHRAGM -Ultrasound -Weaning -Mechanical Ventilation
Not yet recruiting
High-Velocity Resistance Training for Brain Blood Flow and Cognitive Function in Older Adults
At Risk for AD-dementia, With Subjective Cognitive Decline, At Risk for Cognitive Decline
Not yet recruiting
Comparison Between Eccentric Hamstring Training and Sprint-Specific Training
Healthy Adult, Athlete
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
The record lists no contact. Use the official record to reach the sponsor.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Simulation-based ultrasound training in people with Ultrasound Training and Ultrasound Simulation, run by Copenhagen University Hospital, Rigshospitalet at 1 site in Denmark.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 1 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 7 Apr 2014. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Denmark. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Technical ultrasound performances (time frame: 2 months). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT01895868, which also lists 1 linked publication.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 7 Apr 2014.