Clinical Evaluation of MDT-2111 in Subjects With Small Aortic Annuli and Symptomatic Severe Aortic Stenosis

A study testing MDT-2111 TAVI 23 mm in people with Aortic Valve Stenosis, run by Medtronic Cardiovascular at 4 sites in Japan.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record

Search all trials

Trial summary

The primary objective of the present trial is to demonstrate the safety and effectiveness of the MDT-2111 in the treatment of symptomatic severe aortic stenosis in subjects with small aortic annuli and deemed difficult for surgical operation. Read more about this study

Who is it for?
Any age
Conditions the study is for
Aortic Valve Stenosis
What is being tested?
MDT-2111 TAVI 23 mm
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
20 participants
Where
4 sitesJapan
Study dates
Jul 2012to Sep 2019
Phase
Interventional

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages Any age
  • All sexes
  • No healthy volunteers
  • Child, Adult, Older adult

Who may be able to join

  • Subject must have co-morbidities such that one cardiologist and one cardiac surgeon agree that medical factors preclude operation, based on a conclusion that the probability of death or serious morbidity exceeds the probability of meaningful improvement.
  • Subject has senile degenerative aortic valve stenosis with:
  • mean gradient > 40 mmHg or jet velocity greater than 4.0 m/s by either resting or dobutamine stress echocardiogram, or simultaneous pressure recordings at cardiac catheterization (either resting or dobutamine stress), AND an initial aortic valve area of ≤ 0.8 cm² (or aortic valve area index ≤ 0.5 cm²/m²) by resting echocardiogram.
  • Subject is symptomatic from his/her aortic valve stenosis, as demonstrated by NYHA Functional Class Class III or greater. If screening committee agrees the eligibility of a patient with class II , based on medical factors, he/she can be enrolled.
  • Patient has been informed of the nature of the trial and has signed an Informed Consent Form.
  • Patient agrees to comply with specified follow-up evaluations and to return to the same investigational site where the procedure was performed.

Who cannot join

  • Evidence of an acute myocardial infarction ≤ 30 days prior to the intended treatment.
  • Any percutaneous coronary or peripheral interventional procedure performed within 30 days prior to the procedure.
  • Blood dyscrasias as defined:
  • Leukopenia (WBC count < 1,000 cells/mm³)
  • Thrombocytopenia (platelet count <50,000 cells/mm³)
  • History of bleeding diathesis or coagulopathy
Show all 53Show fewer
  • Hypercoagulable states
  • Untreated clinically significant coronary artery disease requiring revascularization.
  • Cardiogenic shock manifested by low cardiac output, vasopressor dependence, or mechanical hemodynamic support.
  • Need for emergency surgery for any reason.
  • Severe ventricular dysfunction with left ventricular ejection fraction (LVEF) < 20% as measured by resting echocardiogram.
  • Recent (within 6 months) cerebrovascular accident (CVA) or transient ischemic attack(TIA).
  • End stage renal disease requiring chronic dialysis.
  • GI bleeding within the past 3 months.
  • A known hypersensitivity or contraindication to any of the following which cannot be adequately pre-medicated:
  • Aspirin
  • Ticlopidine
  • Heparin
  • Contrast media
  • Nitinol (titanium and nickel alloy)
  • Ongoing sepsis, including active endocarditis.
  • Subject refuses a blood transfusion.
  • Life expectancy < 12 months due to associated non-cardiac co-morbid conditions.
  • Other medical, social, or psychological conditions that in the opinion of an Investigator precludes the subject from appropriate consent.
  • Severe dementia (resulting in either inability to provide informed consent for the trial/procedure, prevents independent lifestyle outside of a chronic care facility, or will fundamentally complicate rehabilitation from the procedure or compliance with follow-up visits).
  • Currently participating in an investigational drug or another device trial. Note: Trials requiring extended follow-up for products that were investigational, but have since become commercially available, are not considered investigational trials.
  • Symptomatic carotid or vertebral artery disease.
  • Native aortic annulus size < 18 mm or > 20 mm per the screening diagnostic imaging.
  • Pre-existing prosthetic heart valve in any position.
  • Mixed aortic valve disease (aortic stenosis and aortic regurgitation with predominant aortic regurgitation).
  • Mitral regurgitation (moderate to severe) or severe tricuspid regurgitation.
  • Moderate to severe mitral stenosis.
  • Hypertrophic obstructive cardiomyopathy.
  • Echocardiographic evidence of intracardiac mass, thrombus or vegetation.
  • Severe basal septal hypertrophy with an outflow gradient.
  • Ascending aorta diameter > 34 mm
  • Congenital bicuspid or unicuspid valve verified by echocardiography.
  • For patients with native coronary artery dependent circulation:
  • Sinus of valsalva width < 25 mm OR
  • Height of the left or right coronary sinus of valsalva (to the tubular aorta) < 15mm.
  • Femoral or iliac artery of the first choice corresponding to any one of the following:
  • Angle at aortic root (the angle between aortic valve annulus plane and horizontal plane/vertebra) exceeds 70°.
  • Vessel diameter of femoral or iliac artery is less than 6 mm.
  • Aorta has severe calcification, excess tortuosity or severe atherosclerosis.
  • Transarterial access not able to accommodate an 18Fr sheath.
  • Subclavian artery of the second choice corresponding to any one of the following:
  • Angle at aortic root (the angle between aortic valve annulus plane and horizontal plane/vertebra) exceeds 70° (in the case of left subclavian artery) and 30° (in the case of right subclavian artery).
  • Vessel diameter of subclavian artery is less than 6 mm.
  • Transarterial access not able to accommodate an 18Fr sheath.
  • Direct Aortic Artery as third line choice of access. Patients are excluded from Direct Aortic access if:
  • Access site is less than 6 cm from the aortic valve basal plane
  • Access site has calcification or porcelain aorta
  • Access site and delivery trajectory contain RIMA or patent RIMA graft

Trial locations and contacts

4 sites in 1 country.

Japan4 sites
  • Saitama Medical University

    Hidaka, Saitama

  • Shonan Kamakura General Hospital

    Kamakura, Kanagawa

  • National Cerebral and Cardiovascular Center

    Suita, Osaka

  • Osaka University Hospital

    Suita, Osaka

Other trials in Japan

About this study

Official title: Medtronic MDT-2111 CoreValve Japan 23mm Study

The primary objective of the present trial is to demonstrate the safety and effectiveness of the MDT-2111 in the treatment of symptomatic severe aortic stenosis in subjects with small aortic annuli and deemed difficult for surgical operation.

Read the detailed description

The purpose of this trial is to evaluate the effectiveness and safety of the MDT-2111 TAV system in subjects with small annuli and symptomatic severe AS deemed difficult for surgical intervention. The primary endpoint is a composite of functional effectiveness as measured by improvement of at least 1 New York Heart Association (NYHA) class from baseline to 6 months and anatomical effectiveness as measured by Effective Orifice Area (EOA) ≥1.0 cm² at 6 months.

Being tested
MDT-2111 TAVI 23 mm
Keywords
Valvular Heart Disease, Severe Aortic Stenosis, Aortic Valve Replacement
Medical subject headings
Aortic Valve Stenosis, Heart Valve Diseases

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • MDT-2111 TAVI 23 mmDevice

    Device: 23 mm MDT-2111 System for Transcatheter Aortic Valve Implantation (TAVI) Transcatheter Aortic Valve Implantation (TAVI) using the 23 mm MDT-2111 system.

Study groups in NCT01634269
Study groupRoleWhat they receive
MDT-2111 TAVI 23 mmExperimentalSubjects with small annuli and symptomatic severe AS deemed difficult for surgical intervention.
Receives: Device: MDT-2111 TAVI 23 mm

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Composite Score of Change in New York Heart Association (NYHA) Class and Effective Orifice Area (EOA).

    The primary endpoint is a composite of functional effectiveness as measured by improvement of at least 1 NYHA class from baseline to 6 months and anatomical effectiveness as measured by Effective Orifice Area (EOA) ≥1.0 cm² at 6 months.

    Measured: baseline and 6 months

Secondary outcomes (38)
  1. New York Heart Classification (NYHA) Over Time

    NEW YORK HEART ASSOCIATION CLASSIFICATION (NYHA) Class I: Subject with cardiac disease but without resulting limitations of physical activity.

    Class II: Subjects with cardiac disease resulting in slight limitation of physical activity.

    Class III: Subjects with cardiac disease resulting in marked limitation of physical activity.

    Class IV: Subjects with cardiac disease resulting in inability to carry on any physical activity without discomfort.

    Measured: 30 days

  2. New York Heart Classification (NYHA) Over Time

    NEW YORK HEART ASSOCIATION CLASSIFICATION (NYHA) Class I: Subject with cardiac disease but without resulting limitations of physical activity.

    Class II: Subjects with cardiac disease resulting in slight limitation of physical activity.

    Class III: Subjects with cardiac disease resulting in marked limitation of physical activity.

    Class IV: Subjects with cardiac disease resulting in inability to carry on any physical activity without discomfort.

    Measured: 6 months

  3. New York Heart Classification (NYHA) Over Time

    NEW YORK HEART ASSOCIATION CLASSIFICATION (NYHA) Class I: Subject with cardiac disease but without resulting limitations of physical activity.

    Class II: Subjects with cardiac disease resulting in slight limitation of physical activity.

    Class III: Subjects with cardiac disease resulting in marked limitation of physical activity.

    Class IV: Subjects with cardiac disease resulting in inability to carry on any physical activity without discomfort.

    Measured: 12 months

  4. New York Heart Classification (NYHA) Over Time

    NEW YORK HEART ASSOCIATION CLASSIFICATION (NYHA) Class I: Subject with cardiac disease but without resulting limitations of physical activity.

    Class II: Subjects with cardiac disease resulting in slight limitation of physical activity.

    Class III: Subjects with cardiac disease resulting in marked limitation of physical activity.

    Class IV: Subjects with cardiac disease resulting in inability to carry on any physical activity without discomfort.

    Measured: 24 months

  5. Major Adverse Cardiovascular and Cerebrovascular Event (MACCE)

    MACCE is defined as a composite of:

    • all-cause death
    • myocardial infarction (MI)
    • all stroke, and
    • reintervention (defined as any cardiac surgery or percutaneous reintervention catheter procedure that repairs, otherwise alters or adjusts, or replaces a previously implanted valve)

    Measured: 0 day to 30 days

  6. Major Adverse Cardiovascular and Cerebrovascular Event (MACCE)

    MACCE is defined as a composite of:

    • all-cause death
    • myocardial infarction (MI)
    • all stroke, and
    • reintervention (defined as any cardiac surgery or percutaneous reintervention catheter procedure that repairs, otherwise alters or adjusts, or replaces a previously implanted valve)

    Measured: 0 day to 6 months

  7. Major Adverse Cardiovascular and Cerebrovascular Event (MACCE)

    MACCE is defined as a composite of:

    • all-cause death
    • myocardial infarction (MI)
    • all stroke, and
    • reintervention (defined as any cardiac surgery or percutaneous reintervention catheter procedure that repairs, otherwise alters or adjusts, or replaces a previously implanted valve)

    Measured: 0 day to 12 months

  8. Major Adverse Cardiovascular and Cerebrovascular Event (MACCE)

    MACCE is defined as a composite of:

    • all-cause death
    • myocardial infarction (MI)
    • all stroke, and
    • reintervention (defined as any cardiac surgery or percutaneous reintervention catheter procedure that repairs, otherwise alters or adjusts, or replaces a previously implanted valve)

    Measured: 0 day to 24 months

  9. Device Success as Defined in the Description.

    The following components must be satisfied for device success:

    1. successful vascular access, delivery and deployment of device and successful retrieval of delivery system
    2. correct position of device in the proper anatomical location
    3. EOA≥1.0 cm² AND mean gradient <20 mmHg or peak velocity <3 m/s, without moderate or severe AR
    4. only one valve implanted.

    Measured: after procedure or discharge

  10. Procedural Success, Defined as Device Success and Absence of In-hospital MACCE

    Procedural success is defined as device success and absence of in-hospital MACCE.

    Measured: from admission for procedure to discharge

  11. Echocardiographic Assessment of Prosthetic Valve Performance - Mean Gradient

    Measured: 30 days

  12. Echocardiographic Assessment of Prosthetic Valve Performance - Mean Gradient

    Measured: 6 months

  13. Echocardiographic Assessment of Prosthetic Valve Performance - Mean Gradient

    Measured: 12 months

  14. Echocardiographic Assessment of Prosthetic Valve Performance - Mean Gradient

    Measured: 24 months

  15. Echocardiographic Assessment of Prosthetic Valve Performance - Effective Orifice Area (EOA)

    Measured: 30 days

  16. Echocardiographic Assessment of Prosthetic Valve Performance - Effective Orifice Area (EOA)

    Measured: 6 months

  17. Echocardiographic Assessment of Prosthetic Valve Performance - Effective Orifice Area (EOA)

    Measured: 12 months

  18. Echocardiographic Assessment of Prosthetic Valve Performance - Effective Orifice Area (EOA)

    Measured: 24 months

  19. Echocardiographic Assessment of Prosthetic Valve Performance - Left Ventricular Ejection Fraction (LVEF)

    Measured: 30 days

  20. Echocardiographic Assessment of Prosthetic Valve Performance - Left Ventricular Ejection Fraction (LVEF)

    Measured: 6 months

  21. Echocardiographic Assessment of Prosthetic Valve Performance - Left Ventricular Ejection Fraction (LVEF)

    Measured: 12 months

  22. Echocardiographic Assessment of Prosthetic Valve Performance - Left Ventricular Ejection Fraction (LVEF)

    Measured: 24 months

  23. Echocardiographic Assessment of Prosthetic Valve Performance - Total Aortic Regurgitation (Transvalvular & Paravalvular) (Total AR)

    Measured: 30 days

  24. Echocardiographic Assessment of Prosthetic Valve Performance - Total Aortic Regurgitation (Transvalvular & Paravalvular) (Total AR)

    Measured: 6 months

  25. Echocardiographic Assessment of Prosthetic Valve Performance - Total Aortic Regurgitation (Transvalvular & Paravalvular) (Total AR)

    Measured: 12 months

  26. Echocardiographic Assessment of Prosthetic Valve Performance - Total Aortic Regurgitation (Transvalvular & Paravalvular) (Total AR)

    Measured: 24 months

  27. Repeat Hospitalization

    Measured: 0 day to 30 days

  28. Repeat Hospitalization

    Measured: 0 day to 6 months

  29. Repeat Hospitalization

    Measured: 0 day to 12 months

  30. Repeat Hospitalization

    Measured: 0 day to 24 months

  31. Valve-related Deaths

    Measured: 0 day to 30 days

  32. Valve-related Deaths

    Measured: 0 day to 6 months

  33. Valve-related Deaths

    Measured: 0 day to 12 months

  34. Valve-related Deaths

    Measured: 0 day to 24 months

  35. Quality of Life Assessment Using SF-36 Questionnaire - Physical Component Summary (Paired Change From Baseline)

    The SF-36 assessment was used to evaluate subject Quality of life (QoL) by assessing change in physical function and general health status. The SF-36 v2 ͭ ͫ Scoring Program was used to convert raw scores ranging from 0 to 100 into norm-based scores, allowing direct comparison to the reference values for the Japanese population. The Z-score of each subdomain is calculated as the numbers of standard deviation away from the Japanese population mean of the corresponding raw score. Norm-based score is then derived as fifty plus 10 times of the z-score. A norm-based score of less than 50 was interpreted as below average when compared to the Japanese population whereas norm-based scores greater than 50 were interpreted as above average.

    Measured: Baseline to 30 days

  36. Quality of Life Assessment Using SF-36 Questionnaire - Physical Component Summary (Paired Change From Baseline)

    The SF-36 assessment was used to evaluate subject Quality of life (QoL) by assessing change in physical function and general health status. The SF-36 v2 ͭ ͫ Scoring Program was used to convert raw scores ranging from 0 to 100 into norm-based scores, allowing direct comparison to the reference values for the Japanese population. The Z-score of each subdomain is calculated as the numbers of standard deviation away from the Japanese population mean of the corresponding raw score. Norm-based score is then derived as fifty plus 10 times of the z-score. A norm-based score of less than 50 was interpreted as below average when compared to the Japanese population whereas norm-based scores greater than 50 were interpreted as above average.

    Measured: Baseline to 6 months

  37. Quality of Life Assessment Using SF-36 Questionnaire - Physical Component Summary (Paired Change From Baseline)

    The SF-36 assessment was used to evaluate subject Quality of life (QoL) by assessing change in physical function and general health status. The SF-36 v2 ͭ ͫ Scoring Program was used to convert raw scores ranging from 0 to 100 into norm-based scores, allowing direct comparison to the reference values for the Japanese population. The Z-score of each subdomain is calculated as the numbers of standard deviation away from the Japanese population mean of the corresponding raw score. Norm-based score is then derived as fifty plus 10 times of the z-score. A norm-based score of less than 50 was interpreted as below average when compared to the Japanese population whereas norm-based scores greater than 50 were interpreted as above average.

    Measured: Baseline to 12 months

  38. Quality of Life Assessment Using SF-36 Questionnaire - Physical Component Summary (Paired Change From Baseline)

    The SF-36 assessment was used to evaluate subject Quality of life (QoL) by assessing change in physical function and general health status. The SF-36 v2 ͭ ͫ Scoring Program was used to convert raw scores ranging from 0 to 100 into norm-based scores, allowing direct comparison to the reference values for the Japanese population. The Z-score of each subdomain is calculated as the numbers of standard deviation away from the Japanese population mean of the corresponding raw score. Norm-based score is then derived as fifty plus 10 times of the z-score. A norm-based score of less than 50 was interpreted as below average when compared to the Japanese population whereas norm-based scores greater than 50 were interpreted as above average.

    Measured: Baseline to 24 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted6 Jul 2012 (estimated)
  2. Study startJul 2012
  3. Primary completionFeb 2014
  4. Study completionSep 2019

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
20 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT01634269
Sponsor's protocol ID
MDT-2111 23 mm trial
Status last verified
Oct 2019
First submitted
2 Jul 2012
Last updated
15 Oct 2019
Data monitoring committee
Yes
Individual data sharing
Undecided

Publications

  • Sawa Y, Torikai K, Kobayashi J, Niinami H, Kuratani T, Maeda K, Kanzaki H, Komiyama N, Tanaka Y, Zhang A, Saito S. Midterm Outcomes With a Self-Expandable Transcatheter Heart Valve in Japanese Patients With Symptomatic Severe Aortic Stenosis. Circ J. 2017 Jul 25;81(8):1108-1115. doi: 10.1253/circj.CJ-17-0112. Epub 2017 Mar 17.

    PubMed 28321003