A Five-Year Metal-on-Metal Retrospective Clinical Study

An observational study of Osteoarthritis, run by Anderson Orthopaedic Research Institute at 1 site in United States.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

This retrospective study will review the Anderson Orthopaedic Institute's initial experience among a consecutive series of 126 patients who had primary total hip arthroplasty using a metal-on-metal articulation consisting of a DePuy Pinnacle cup with an Ultamet liner coupled with a 36-mm cobalt-chrome alloy femoral… Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Osteoarthritis
What is being tested?
Metal-on-metal primary total hip arthroplasty (DePuy )
Type of treatment
Medical device
How many people
126 participants
Where
1 siteUnited States
Study dates
Dec 2011to Jun 2012
Phase
Observational
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Study population: A consecutive series of patients who had primary total hip arthroplasties performed at the Anderson Clinic using DePuy Pinnacle cups, Ultamet metal liners and 36-mm cobalt-chromium alloy femoral heads.

Who may be able to join

  • Primary total hip arthroplasty patients who had surgery between April 2001 and November 2002 who were implanted with a Pinnacle acetabular cup, an Ultamet metal-on-metal insert and a 36mm cobalt-chrome alloy femoral head

Who cannot join

  • Revision total hip arthroplasties
  • Primary total hip arthroplasties using Ultamet liners coupled with 28-mm femoral heads

Trial locations and contacts

1 site in 1 country.

United States1 site
  • Anderson Orthopaedic Research Institute

    Alexandria, Virginia, 22306

Other trials in United States

About this study

This retrospective study will review the Anderson Orthopaedic Institute's initial experience among a consecutive series of 126 patients who had primary total hip arthroplasty using a metal-on-metal articulation consisting of a DePuy Pinnacle cup with an Ultamet liner coupled with a 36-mm cobalt-chrome alloy femoral head. The relationship between metal ion levels, cup orientation, osteolysis, radiographic implant stability and clinical outcome measures including component revision, complications, patient satisfaction and Harris Hip Scores will be evaluated.

Read the detailed description

Metal-on-metal bearings for total hip arthroplasty are an alternative to traditional polyethylene bearing surfaces and hip simulators studies have shown that metal-on-metal bearings have lower wear than metal-on-polyethylene bearings. In addition, simulator studies indicate that the amount of wear decreases as head size increases allowing the use of larger head diameters than possible with other bearing surfaces. Since dislocation is currently the most common reason for reoperation in the United States, representing 22.5% of hip revisions, the combination of low wear and larger head sizes to reduce dislocation hold the promise of improving outcome among total hip arthroplasty patients. While there are potential advantages to metal-on-metal bearings, a few concerns have been noted in the literature. Although the total volume of wear is low with these bearings, the articulation generates metal debris that may be related to patient and surgical factors such as implant positioning. Despite a reduced wear volume, there is also the possibility that an increased bioreactivity associated with metal debris might induce an osteolytic response or local tissue hypersensitivity reaction.

This study will retrospectively review the outcome of a consecutive series of 126 patients who had 131 primary THAs performed between April 2001 and November 2002 at the Anderson Clinic with a Pinnacle acetabular cup, an Ultamet insert and a 36-mm cobalt-chrome alloy femoral head. These total hip arthroplasties represent the Anderson Orthopaedic Institute's in initial experience with this implant. The relationship between metal ion levels, cup orientation, osteolysis, radiographic implant stability and clinical outcome measures including component revision, complications, patient satisfaction and Harris Hip Scores will be evaluated. The outcome data from our analysis will also be compared with the data from other published series with metal-on-metal bearing surfaces. Serial radiographs obtained as part of routine post-operative care will be used to evaluate osteolysis, implant stability and radiographic complications such as periprosthetic fracture. The area of each osteolytic region will be measured on the AP pelvic x-ray using Martell's Hip Analysis Suite. Computed tomography (CT) scans obtained as part of routine follow-up will be also analyzed to identify regions of acetabular osteolysis. The volume and location of each osteolytic defect identified on CT will be evaluated using three-dimensional image analysis software (Analyze, Biomedical Imaging Resource, Rochester, MN). A three-dimensional (3D) reconstruction of the pelvis, cup and acetabular osteolytic lesions will also be generated from the CT image data. This reconstruction will be oriented to simulate the AP pelvic radiographic view. Cobalt and chromium ion level data will be compiled for patients who had blood drawn to evaluate metal ion levels. The mean and median blood metal-ion levels for these patients will be calculated and the results will be compared to the metal-ion levels reported in the literature.

Conditions
Osteoarthritis
Being tested
Metal-on-metal primary total hip arthroplasty (DePuy )
Keywords
Hip replacement, Metal-on-metal bearings, Osteolysis, Metal ion levels, Outcome
Medical subject headings
Osteoarthritis, Osteolysis

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Metal-on-metal primary total hip arthroplasty (DePuy )Device

    Also called DePuy Pinnacle acetabular cup, DePuy Ultamet metal liner, DePuy 36-mm femoral head

    Replacement of a patient's native hip with an artificial implant featuring a metal-on-metal articulation

Study groups in NCT01481896
Study groupRoleWhat they receive
Metal-on-Metal Total Hip ArthroplastiesConsecutive series of patients who had metal-on-metal primary total hip arthroplasty performed with DePuy Pinnacle cups, Ultamet metal liners and 36-mm cobalt-chromium alloy femoral heads.
Receives: Device: Metal-on-metal primary total hip arthroplasty (DePuy )

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Metal Ion Levels Per Participant

    Metal ion levels include cobalt and chromium ion levels determined from tests of blood samples. Metal ion levels are reported per participant since blood samples were taken from individual participants who could have had one or both hips replaced.

    Measured: At a mean of 4.2 years after primary total hip arthroplasty

Secondary outcomes (6)
  1. Cup Orientation Per Hip

    Cup orientation including abduction and anteversion is determined using follow-up radiographs. Since a participant with both hips replaced could have different cup orientations for each hip, cup abduction and anteversion angles are reported per hip.

    Measured: On the first post-operative anteroposterior pelvic radiograph after primary total hip arthroplasty

  2. Harris Hip Score Per Hip

    Harris Hip Scores are derived from a patient questionnaire and physical examination. Since a participant with both hips replaced could have different Harris Hip Scores for each hip, the Harris Hip Scores are reported per hip.

    Measured: At a mean of 5.6 years after primary total hip arthroplasty

  3. Osteolysis Per Hip

    Osteolysis is defined as localized areas of peri-prosthetic bone loss that did not exist prior to surgery and is evaluated using radiographs and CT scans. Since a participant with both hips replaced could have a osteolysis present or absent for each hip, osteolysis is reported per hip.

    Measured: At a mean of 5.6 years after primary total hip arthroplasty

  4. Implant Stability Per Hip

    Implant stability is classified and stable/bone ingrown, fibrous fixed or loose and evaluated using conventional radiographs. Since a participant with both hips replaced could have a different type of stability for each hip, implant stability is reported per hip.

    Measured: At a mean of 5.6 years after primary total hip arthroplasty

  5. Component Revision Per Hip

    For implants that require a component revision, the reason for the revision is determined based on the pre-operative history and operative findings at the time of revision. Since a participant with both hips replaced could have a revision of each hip, component revision is reported per hip.

    Measured: At a mean of 6.7 years after primary total hip arthroplasty

  6. Patient Satisfaction Per Hip

    Whether or not an individual is satisfied with the outcome of their hip arthroplasty is evaluated using a questionnaire. Since a participant with both hips replaced could have a different level of satisfaction for each hip, patient satisfaction is reported per hip.

    Measured: At a mean of 5.6 years after primary total hip arthroplasty

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted30 Nov 2011 (estimated)
  2. Study startDec 2011
  3. Primary completionJun 2012
  4. Study completionJun 2012

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Cohort
Time perspective
Retrospective
Enrolment
126 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT01481896
Sponsor's protocol ID
AORI2011-0100
Other IDs
Study #09013
Status last verified
Aug 2013
First submitted
23 Nov 2011
Last updated
9 Oct 2013
Data monitoring committee
No

Publications

  • MacDonald SJ. Metal-on-metal total hip arthroplasty: the concerns. Clin Orthop Relat Res. 2004 Dec;(429):86-93. doi: 10.1097/01.blo.0000150309.48474.8b.

    PubMed 15577471
  • Bozic KJ, Kurtz S, Lau E, Ong K, Chiu V, Vail TP, Rubash HE, Berry DJ. The epidemiology of bearing surface usage in total hip arthroplasty in the United States. J Bone Joint Surg Am. 2009 Jul;91(7):1614-20. doi: 10.2106/JBJS.H.01220.

    PubMed 19571083
  • Bozic KJ, Kurtz SM, Lau E, Ong K, Chiu V, Vail TP, Rubash HE, Berry DJ. The epidemiology of revision total knee arthroplasty in the United States. Clin Orthop Relat Res. 2010 Jan;468(1):45-51. doi: 10.1007/s11999-009-0945-0. Epub 2009 Jun 25.

    PubMed 19554385
  • Dowson D, Hardaker C, Flett M, Isaac GH. A hip joint simulator study of the performance of metal-on-metal joints: Part II: design. J Arthroplasty. 2004 Dec;19(8 Suppl 3):124-30. doi: 10.1016/j.arth.2004.09.016.

    PubMed 15578566
  • Rieker CB, Schon R, Kottig P. Development and validation of a second-generation metal-on-metal bearing: laboratory studies and analysis of retrievals. J Arthroplasty. 2004 Dec;19(8 Suppl 3):5-11. doi: 10.1016/j.arth.2004.09.017.

    PubMed 15578545
  • Silva M, Heisel C, Schmalzried TP. Metal-on-metal total hip replacement. Clin Orthop Relat Res. 2005 Jan;(430):53-61. doi: 10.1097/01.blo.0000149995.84350.d7.

    PubMed 15662304
  • Beaule PE, Campbell P, Mirra J, Hooper JC, Schmalzried TP. Osteolysis in a cementless, second generation metal-on-metal hip replacement. Clin Orthop Relat Res. 2001 May;(386):159-65. doi: 10.1097/00003086-200105000-00020.

    PubMed 11347829
  • Willert HG, Buchhorn GH, Fayyazi A, Flury R, Windler M, Koster G, Lohmann CH. Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study. J Bone Joint Surg Am. 2005 Jan;87(1):28-36. doi: 10.2106/JBJS.A.02039pp.

    PubMed 15637030
  • Engh CA Jr, Ho H, Engh CA. Metal-on-metal hip arthroplasty: does early clinical outcome justify the chance of an adverse local tissue reaction? Clin Orthop Relat Res. 2010 Feb;468(2):406-12. doi: 10.1007/s11999-009-1063-8. Epub 2009 Sep 1.

    PubMed 19727991

Questions about this trial

What is this clinical trial studying?

An observational study of Osteoarthritis, run by Anderson Orthopaedic Research Institute at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 9 Oct 2013. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 9 Oct 2013). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Metal Ion Levels Per Participant (time frame: At a mean of 4.2 years after primary total hip arthroplasty). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT01481896, which also lists 9 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 9 Oct 2013.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in