AzTrials
AzTrials

TachyarrhythmiaPhase 4NCT00324662

Study to Verify Proper Detection of Supraventricular Tachyarrhythmia With Single-Lead Dual-Chamber Implantable Cardioverter-Defibrillators (ADRIA)

A Phase 4 study testing Implantable cardioverter-defibrillator in people with Tachyarrhythmia, run by Biotronik SE & Co. KG at 10 sites in 2 countries.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

A unique single-lead dual-chamber implantable cardioverter-defibrillator (ICD) system (produced by Biotronik, Germany) features a conventional electrode in the ventricle (anchored in the ventricular apex) and a floating electrode (ring on the lead body) in the atrium, capable of sensing atrial electrical signals. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Tachyarrhythmia
What is being tested?
Implantable cardioverter-defibrillator
Type of treatment
Medical device
How many people
260 participants
Where
10 sitesin 2 countries
Study dates
Aug 2003to Jul 2008
Phase
Phase 4
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • ICD indication according to American College of Cardiology/American Heart Association (ACC/AHA) guidelines.
  • Informed consent

Who cannot join

  • Permanent atrial fibrillation
  • Requirement for atrial pacing
  • Patient is underage
  • No signed patient agreement
  • Patient life expectancy under 6 months

Trial locations and contacts

10 sites in 2 countries.

10 sites in 2 countries

Germany9 sites
  • Sana Klinikum Lichtenberg

    Berlin, 10365

  • Charité-Universitätsmedizin Campus Benjamin Franklin, Med. Klinik II / Kardiologie

    Berlin, 12200

  • Vivantes Netzwerk für Gesundheit GmbH (Humboldt)

    Berlin, 13437

  • Kardiologische Praxis

    Bonn, 53115

  • St. Johannes Hospital, Medizinische Klinik I

    Dortmund, 44137

  • Georg-August-Universität, Universitätsklinikum Göttingen

    Göttingen, 37099

  • Medizinische Hochschule Hannover

    Hanover, 30625

  • Westfälische Wilhelms-Universität

    Münster, 48129

  • Klinikum der Stadt Villingen Schwenningen GmbH

    Villingen, 78050

Other trials in Germany

Switzerland1 site
  • Kantonspital Basel, Abteilung für Kardiologie

    Basel, 4031

Other trials in Switzerland

About this study

Official title: ADRIA - Belos A+ vs DR Clinical Investigation of Arrhythmia Discrimination

A unique single-lead dual-chamber implantable cardioverter-defibrillator (ICD) system (produced by Biotronik, Germany) features a conventional electrode in the ventricle (anchored in the ventricular apex) and a floating electrode (ring on the lead body) in the atrium, capable of sensing atrial electrical signals. The purpose of this study is to determine whether this system detects a supraventricular tachyarrhythmia (e.g. atrial fibrillation, atrial tachycardia) in the equivalent manner as conventional dual-lead dual-chamber ICDs using two separate electrodes anchored in the ventricle and in the atrium, respectively.

Read the detailed description

Supraventricular tachyarrhythmia (SVT) is the main cause of inappropriate therapy in patients with single-chamber implantable cardioverter-defibrillators (ICDs). To minimize inappropriate shock delivery, ICDs should sense both atrial and ventricular intracardiac signals. Dual-chamber ICDs are used for this purpose, but are associated with increased postoperative complications due to the implantation of a separate atrial lead. It has to be shown that a novel single-lead dual-chamber ICD-system with enhanced SVT discrimination can achieve the same specificity in discriminating SVT episodes as conventional dual-chamber ICD, without the disadvantage of the implantation of several leads. In this study patients eligible for dual-chamber ICD therapy who do not need atrial pacing will receive either a single-lead dual-chamber ICD (Belos A+ and Kainox A+ electrode) or a dual-lead dual-chamber ICD (Belos DR). SMART detection algorithm will be used in both study groups for discrimination between atrial and ventricular tachyarrhythmias. Atrial tachyarrhythmia episodes are facultatively induced in both groups at implantation or predischarge via a bipolar stimulation catheter. Induced episodes and the corresponding ICD intervention (detection and therapy or inhibition of therapy) are documented. Follow-ups are scheduled for 1, 3, 6 and 12 months after implantation. ICD intervention, particularly related to spontaneous SVT episodes, will be evaluated based on ICD diagnostic memory data interrogated at follow-up controls.

Conditions
Tachyarrhythmia
Being tested
Implantable cardioverter-defibrillator
Keywords
Implantable cardioverter-defibrillator, Ventricular tachyarrhythmia, Supraventricular tachyarrhythmia, Electric Countershock
Medical subject headings
Tachycardia, Tachycardia, Ventricular

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Implantable cardioverter-defibrillatorDevice

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Rate of correctly discriminated supraventricular tachyarrhythmia episodes (specificity)

Secondary outcomes (4)
  1. Complication rate (e.g. lead dislocation, lead fracture)

  2. Duration of implantation

  3. Electrode performance (P-/R-wave amplitudes, ventricular pacing threshold and impedance)

  4. Sensitivity (rate of correctly discriminated episodes of ventricular fibrillation or ventricular tachycardia)

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted11 May 2006 (estimated)
  2. Study startAug 2003
  3. Primary completionJul 2008
  4. Study completionJul 2008

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase 4
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
None (open label)
Enrolment
260 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT00324662
Sponsor's protocol ID
TA044
Status last verified
Sep 2008
First submitted
10 May 2006
Last updated
30 Sep 2008
Results posted
No

Publications

  • Sticherling C, Zabel M, Spencker S, Meyerfeldt U, Eckardt L, Behrens S, Niehaus M; ADRIA Investigators. Comparison of a novel, single-lead atrial sensing system with a dual-chamber implantable cardioverter-defibrillator system in patients without antibradycardia pacing indications: results of a randomized study. Circ Arrhythm Electrophysiol. 2011 Feb;4(1):56-63. doi: 10.1161/CIRCEP.110.958397. Epub 2010 Dec 14.

    PubMed 21156772

Questions about this trial

What is this clinical trial studying?

A Phase 4 study testing Implantable cardioverter-defibrillator in people with Tachyarrhythmia, run by Biotronik SE & Co. KG at 10 sites in 2 countries.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 30 Sep 2008. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 10 sites in Germany, Switzerland. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

What does this phase mean?

Phase 4 studies take place after a treatment is approved, to learn more about its long-term benefits and risks in everyday use.

Not every study follows the same path, and some studies (observational studies, device studies) have no phase.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Rate of correctly discriminated supraventricular tachyarrhythmia episodes (specificity). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT00324662, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 30 Sep 2008.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in