Clinical trials: Ventricular Tachyarrhythmia
- Condition Ventricular Tachyarrhythmia
- Funder type Industry (pharma, biotech, devices)
- Has posted results yes
Ischemic Ventricular Tachycardia
Therapy Cool Path Ablate VT
To demonstrate that ablation with the Therapy Cool Path Duo cardiac ablation system can eliminate ischemic VT and that its use does not result in an unacceptable risk of serious adverse events.
- Trial name
- Ablate-VT (NCT00925522)
- Testing
- Therapy Cool Path Duo Cardiac Ablation System
- Where
- 5 sites in United States
- Volunteers
- 20 people
- Sponsor
- Abbott Medical Devices
Ventricular Tachycardia, Atrial Fibrillation
AVAI: Atrial Ventricular Arrythmia Incidence
The purpose of this observational study is to collect data regarding the population of patients implanted with St. Jude Medical ICD.
- Trial name
- AVAI (NCT00832975)
- Where
- 2 sites in Spain
- Volunteers
- 157 people
- Sponsor
- Abbott Medical Devices
Ventricular Fibrillation, Ventricular Tachycardia
Understanding Outcomes With the EMBLEM™ S-ICD in Primary Prevention Patients With Low Ejection Fraction
This study assesses the 18-month incidence of inappropriate shocks in subjects implanted with the EMBLEM Subcutaneous Implantable Defibrillator (S-ICD) for primary prevention of sudden cardiac death.
- Conditions
- Ventricular Fibrillation, Ventricular Tachycardia, Low Cardiac Output
- Trial name
- UNTOUCHED (NCT02433379)
- Testing
- EMBLEM S-ICD System
- Where
- 110 sites in United States, Belgium and 11 more
- Volunteers
- 1,173 people
- Sponsor
- Boston Scientific Corporation
Persistent Atrial Fibrillation, Ventricular Tachycardia
Advisor HD Grid Observational Study
The aim of this study is to quantify and characterize the outcomes of radiofrequency (RF) ablation after, and the utility of electroanatomical mapping with the Advisor™ HD Grid Mapping Catheter, Sensor Enabled™ (hereafter called…
- Trial name
- NCT03733392
- Testing
- Advisor HD Grid Mapping Catheter, Sensor Enabled
- Where
- 25 sites in Australia, Austria and 9 more
- Volunteers
- 379 people
- Sponsor
- Abbott Medical Devices
Monomorphic Ventricular Tachycardia
Substrate Targeted Ablation Using the FlexAbility™ Ablation Catheter System for the Reduction of Ventricular Tachycardia
To demonstrate that scar-based ventricular tachycardia (VT) ablation using the FlexAbility™ ablation catheter system results in a superior clinical outcome compared to routine drug therapy in subjects with documented Monomorphic…
- Trial name
- STAR-VT (NCT02130765)
- Testing
- Cardiac catheter ablation with ICD/CRT-D
- Where
- 38 sites in United States, Australia and 3 more
- Volunteers
- 64 people
- Sponsor
- Abbott Medical Devices
Scar-related Atrial Tachycardia, Persistent Atrial Fibrillation
A Study Assessing Arrhythmia Mapping With a Globe-Shaped, High-Density, Multi-Electrode Mapping Catheter
The purpose of this study is to assess the performance and safety for the use of the investigational catheter for intracardiac mapping in the atria and ventricles.
- Conditions
- Scar-related Atrial Tachycardia, Persistent Atrial Fibrillation, Paroxysmal Atrial Fibrillation, Ventricular Tachycardia
- Trial name
- COSMOS (NCT05373862)
- Testing
- Globe-Shaped, High-Density, Multi-Electrode Mapping Catheter
- Where
- 4 sites in Belgium, Croatia and 1 more
- Volunteers
- 40 people
- Sponsor
- Biosense Webster, Inc.
Ventricular Tachycardia, Ventricular Fibrillation
DATAS: The Dual Chamber & Atrial Tachyarrhythmias Adverse Events Study
The Dual Chamber \& Atrial Tachyarrhythmias Adverse Events Study (DATAS) was designed to analyze the ability of dual chamber ICDs, to reduce clinically significant adverse events as compared to single chamber ICD in a non…
- Conditions
- Ventricular Tachycardia, Ventricular Fibrillation, Defibrillators, Implantable
- Trial name
- DATAS (NCT00157820)
- Testing
- Single Chamber Implantable Cardioverter Defibrillator, Dual Chamber implantable cardioverter defibrilator
- Volunteers
- 354 people
- Sponsor
- Medtronic Cardiac Rhythm and Heart Failure
Bradycardia, Sinus Node Dysfunction
Physiologic Pacing Registry
The Physiologic Pacing Registry is a prospective, observational, multi-center registry performed to gain a broader understanding of 1) physiologic pacing implant and follow-up workflows, including pacing and sensing measurements…
- Conditions
- Bradycardia, Sinus Node Dysfunction, Heart Block, Syncope
- Trial name
- NCT03719040
- Testing
- Physiologic pacing device implant
- Where
- 50 sites in United States, Australia and 14 more
- Volunteers
- 870 people
- Sponsor
- Abbott Medical Devices
Tachyarrhythmias, Heart Failure
ConsultaTM CRT-D Clinical Evaluation Study
The purpose of the Consulta clinical study is to evaluate the overall system safety and clinical performance of the Consulta Implantable Cardioverter Defibrillator with Cardiac Resynchronization Therapy (CRT-D).
- Conditions
- Tachyarrhythmias, Heart Failure, Ventricular Dysfunction
- Trial name
- NCT00526162
- Testing
- Bi-ventricular Implantable Cardioverter Defibrillator
- Where
- Germany
- Volunteers
- 83 people
- Sponsor
- Medtronic Cardiac Rhythm and Heart Failure
Atrial Fibrillation, Tachycardia, Supraventricular
TOCCATA - Touch+™ for Catheter Ablation
The main objective of this study is to demonstrate the clinical safety of a contact force sensing RF ablation catheter when used for the treatment of supraventricular tachycardia and atrial fibrillation.
- Trial name
- TOCCATA (NCT01223469)
- Testing
- Contact force assisted irrigated RF ablation
- Volunteers
- 77 people
- Sponsor
- Abbott Medical Devices
Atrial Fibrillation, Atrial Flutter
Assessment of the Sphere-9™ Catheter and Affera Mapping and Ablation System for Treatment of Atrial and Ventricular Arrhythmias
A prospective, single-arm, multi-center, safety and performance assessment of the Sphere-9™ Catheter and the Affera Mapping and RF Ablation System to treat Atrial Arrhythmias
- Conditions
- Atrial Fibrillation, Atrial Flutter, Ventricular Tachycardia
- Trial name
- NCT04211441
- Testing
- Catheter mapping and ablation with the Sphere-9 Catheter and Affera Mapping and Ablation System
- Where
- 2 sites in Czechia
- Volunteers
- 74 people
- Sponsor
- Medtronic Cardiac Ablation Solutions
Heart Failure, Tachycardia, Ventricular
Optisure Lead Post Approval Study
The purpose of this post approval study is to characterize the chronic performance of the SJM Optisure family of HV leads in patients.
- Trial name
- NCT02235545
- Testing
- St. Jude Medical Optisure Lead
- Where
- 60 sites in United States, Belgium and 5 more
- Volunteers
- 1,735 people
- Sponsor
- Abbott Medical Devices
Cardiac Arrhythmia
EnSite Precision Observational Study
This document is a clinical investigation plan (CIP) for the EnSite Precision Observational Study. This clinical study is intended to quantify and characterize the usage of the EnSite Precision™ Cardiac Mapping System (Software…
- Trial name
- NCT03260244
- Testing
- cardiac mapping and radiofrequency ablation procedure
- Where
- 7 sites in United States
- Volunteers
- 1,065 people
- Sponsor
- Abbott Medical Devices
Ventricular Tachycardia
Catheter Evaluation for Endocardial Ablation in Patients With Ventricular Tachycardia
The primary objective is to provide additional corroborative safety and efficacy data for the Navistar ThermoCool catheter for the treatment of subjects with ischemic Ventricular Tachycardia.
- Trial name
- VT-CoA (NCT00412607)
- Testing
- NAVISTAR® THERMOCOOL® Catheter
- Volunteers
- 249 people
- Sponsor
- Biosense Webster, Inc.
Ventricular Fibrillation, Ventricular Tachycardia
Evaluation of the iD-SystemTM, One-Handed Disposable Internal Defibrillation System.
The main aim is to evaluate the safety and efficacy of the iD-System™, One-handed Disposable Internal Defibrillation System The device is made for manual defibrillation during intra-thoracic procedure, by transferring a shock…
- Trial name
- iD-System (NCT04011631)
- Testing
- Internal defibrillation during cardiac surgery, using the iD-system
- Where
- Belgium
- Volunteers
- 100 people
- Sponsor
- SMART Clinical Products BV
Sudden Cardiac Arrest, Ventricular Arrythmia
Improve Sudden Cardiac Arrest Study
The purpose of this study is to demonstrate that primary prevention patients with one or more additional risk factors (1.5 prevention criteria: syncope/pre-syncope, non-sustained ventricular tachycardia (NSVT), frequent…
- Trial name
- NCT02099721
- Testing
- ICD or CRT-D Device
- Where
- 93 sites in Argentina, Belarus and 14 more
- Volunteers
- 4,222 people
- Sponsor
- Medtronic Cardiac Rhythm and Heart Failure
Ventricular Tachycardia, Ischemic
Early Ablation Therapy for the Treatment of Ischemic Ventricular Tachycardia in Patients With Implantable Cardioverter Defibrillators
The purpose of this study is to determine if early ablation (i.e., ablation of ventricular tachycardia in patients with infrequent VT episodes) is more effective than medical therapy alone for the treatment of ischemic…
- Trial name
- ASPIRE (NCT01557842)
- Testing
- Drug Treatment, Catheter Ablation
- Where
- 23 sites in United States
- Volunteers
- 15 people
- Sponsor
- Biosense Webster, Inc.
Scar-related Atrial Tachycardia, Persistent Atrial Fibrillation
A Study of Intracardiac Ultrasound With the NUVISION NAV Ultrasound Catheter
The purpose of this study is to assess the performance and safety of using the investigational catheter.
- Conditions
- Scar-related Atrial Tachycardia, Persistent Atrial Fibrillation, Paroxysmal Atrial Fibrillation, Ventricular Tachycardia
- Trial name
- NCT05970120
- Testing
- NUVISION NAV Ultrasound Catheter
- Where
- 3 sites in Croatia, Israel and 1 more
- Volunteers
- 30 people
- Sponsor
- Biosense Webster, Inc.
Hyperkalemia
Effect of Sodium Zirconium Cyclosilicate on Arrythmia-related Cardiovascular Outcomes in Participants on Chronic Hemodialysis With Recurrent Hyperkalemia (DIALIZE-Outcomes)
The purpose of this study is to evaluate the effect of Sodium Zirconium Cyclosilicate (SZC) on arrhythmia-related cardiovascular outcomes in participants on chronic hemodialysis with recurrent hyperkalemia.
- Trial name
- NCT04847232
- Testing
- Sodium Zirconium Cyclosilicate (SZC)
- Where
- 340 sites in United States, Argentina and 24 more
- Volunteers
- 2,690 people
- Sponsor
- AstraZeneca
Ventricular Tachycardia, Ventricular Fibrillation
Septal - Success Rate and Clinical Outcome of Septal Implant of Ventricular Defibrillation Lead
The purpose of this study is to determine the safety and efficacy of the implant of a ICD lead of defibrillation in the septum of the right ventricle
- Trial name
- NCT00180297
- Testing
- Endotak Reliance G
- Where
- 18 sites in France
- Volunteers
- 215 people
- Sponsor
- Boston Scientific Corporation