Clinical trials: Partial-thickness Burn Wounds
Burn Injuries
Mepilex Ag Versus Silver Sulfadiazine in Children and Adults With Burn Injuries.
The purpose is to compare time to healing using absorbent foam silver dressing (Mepilex Ag) compared to a silver sulfadiazine (SSD) 1% cream in the treatment of partial thickness burn injuries.284 in-patients in 8-12 centres in…
- Trial name
- NCT01439074
- Testing
- Mepilex Ag, Silver Sulphadiazine Ag cream
- Where
- 9 sites in China
- Volunteers
- 162 people
- Sponsor
- Molnlycke Health Care AB
Burns
A Prospective, Descriptive Cohort Study With Prontosan® Wound Gel X in Partial and Full Thickness Burns Requiring Split Thickness Skin Grafts
The purpose of this study is to evaluate the healing of split thickness skin grafts when treated with Prontosan® Wound Gel X in patients with partial and full thickness skin burns.
- Trial name
- NCT01534858
- Testing
- Prontosan Wound Gel X
- Where
- 3 sites in Germany
- Volunteers
- 51 people
- Sponsor
- B. Braun Ltd. Centre of Excellence Infection Control
Inflammation, Burns
Open Multi-centre Investigation to Evaluate Signs and Symptoms of Local Inflammation/Infection on Chronic Ulcers and Partial Thickness Burns When Using Mepilex Border Ag as an Anti-microbial Wound Dressing
The purpose of this study is to evaluate the change in signs of inflammation/local infection when Mepilex Border Ag is used in normal clinical practice when used on chronic ulcers (venous leg, diabetic foot and pressure ulcers)…
- Conditions
- Inflammation, Burns, Ulcers
- Trial name
- NCT01214811
- Testing
- Mepilex Border Ag
- Where
- 3 sites in United States
- Volunteers
- 27 people
- Sponsor
- Molnlycke Health Care AB
Burn Injury
SN514-066b Enzyme in Deep Partial Thickness Burns
This study will examine the tolerability of a gel formulation of the enzyme SN514 in patients with burns suitable for enzymatic debridement.
- Trial name
- NCT06628037
- Testing
- SN514-066b
- Where
- United States
- Volunteers
- 13 people
- Sponsor
- SERDA bv
Burns
Safety and Efficacy of I-020502 in Meshed Skin Autografting
This is a phase II, multi-centre, controlled study comparing the safety and tolerability on wound healing following an application of I-020502 in a concentration of 1μg/mL TG-PDGF.AB versus staples applied in the same patient to…
- Trial name
- NCT00471939
- Testing
- I-020502
- Where
- Germany
- Volunteers
- 10 people
- Sponsor
- Kuros Biosurgery AG
Leg Ulcer, Diabetic Foot Ulcer
Study to Examine Clinical Performance and Safety of Cutimed® Gelling Fiber in Routine Clinical Practice
This is a post - market study with a wound dressing, a CE-marked medical device available on the european market. The device will be used in routine clinical practice, i.e.
- Conditions
- Leg Ulcer, Diabetic Foot Ulcer, Pressure Ulcer, Surgical Wound
- Trial name
- GELFI (NCT05148390)
- Testing
- Cutimed® Gelling Fiber
- Where
- Germany
- Volunteers
- 36 people
- Sponsor
- BSN Medical GmbH
Burn Injury, Burn Scar
Tissue Quality of Integra vs. BTM Treated Burns
An observational analysis of Integra-treated burns and Novosorb Biodegradable Temporizing Matrix (BTM)-treated burns will be undertaken 12-36 months post final skin graft application by retrospectively analyzing the patient's…
- Conditions
- Burn Injury, Burn Scar, Burn Wounds - Partial Thickness (2nd Degree), Skin Grafting
- Trial name
- NCT06760611
- Sponsor
- Integra LifeSciences Corporation
Burns
Oleogel-S10 Versus Standard of Care in Healing of Grade 2a Burn Wounds
The main goal of this phase III clinical trial is to show safety and efficacy of Oleogel-S10 in the acceleration of wound healing of grade 2a burn wounds.
- Trial name
- NCT01657292
- Testing
- Oleogel-S10 ointment, Octenilin® wound gel
- Where
- 9 sites in Germany, Sweden and 2 more
- Volunteers
- 61 people
- Sponsor
- Birken AG
Burns
Evaluation of Antimicrobial Soft Silicone, Silver Containing, Foam Dressing, Mepilex Border Ag, in Second Degree Burns
The investigation is designed as an open, non-controlled, post-marketing investigation. Subjects with at least one second degree burn less than 9.5x15 cm in size at 1-3 sites will be included.
- Trial name
- NCT01418482
- Testing
- Mepilex Border Ag
- Where
- 2 sites in Sweden
- Volunteers
- 15 people
- Sponsor
- Molnlycke Health Care AB
Burns
Study With an Autologous Dermo-epidermal Skin Substitute for the Treatment of Burns in Children
This phase IIb trial aims to evaluate the efficacy and safety of EHSG-KF (synonym denovoSkin) in comparison to meshed STSG in children with partial deep dermal and full thickness burns.
- Trial name
- NCT03229564
- Testing
- EHSG-KF, STSG
- Where
- 4 sites in Italy, Netherlands and 1 more
- Volunteers
- 12 people
- Sponsor
- CUTISS AG
Thermal Injury, Deep Partial-Thickness Burn
Safety and Efficacy Study of Autologous Engineered Skin Substitute to Treat Partial- and Full-Thickness Burn Wounds
The purpose of this research study is to test how well the investigational treatment, Engineered Skin Substitutes (ESS-W), works for covering and treating burn wounds.
- Conditions
- Thermal Injury, Deep Partial-Thickness Burn, Full-Thickness Burn
- Trial name
- NCT01655407
- Testing
- Autologous Engineered Skin Substitute, Split-Thickness Autograft (AG)
- Where
- 3 sites in United States
- Volunteers
- 10 people
- Sponsor
- Amarantus BioScience Holdings, Inc.
Thermal Burn
Safety and Feasibility of ADRCs Treatment To Patients With Thermal Wounds
The primary objective of the protocol is to evaluate preliminary safety and feasibility of ADRCs via intravenous delivery in the treatment of deep partial and full thickness thermal wounds.
- Trial name
- NCT03435172
- Testing
- Device-ADRCs intravenously infusion
- Where
- 5 sites in United States
- Volunteers
- 15 people
- Sponsor
- Cytori Therapeutics
Burns, Burn Degree Second
A Study to Evaluate the Safety, Tolerability and Efficacy in Patients With Burn(s)
For Phase 1, researchers will explore the safety, and tolerability of PMS-101 and determine the recommended Phase 2 dose (RP2D) using the donor site.
- Trial name
- NCT06440239
- Testing
- PMS-101, Standard treatment
- Where
- Australia
- Volunteers
- 40 people
- Sponsor
- Primoris Therapeutics
Burn
A Follow-up Study to Evaluate the Safety of ALLO-ASC-DFU in ALLO-ASC-BI-101 Clinical Trial
This is an open-label follow up study to evaluate the safety for the subjects with ALLO-ASC-DFU treatment in phase 1 clinical trial(ALLO-ASC-BI-101) for 23 months.
- Trial name
- NCT03183622
- Testing
- ALLO-ASC-DFU
- Where
- South Korea
- Volunteers
- 5 people
- Sponsor
- Anterogen Co., Ltd.
Burns
Phase 2 Pilot Study of the Safety and Efficacy of Topical MW-III in Thermal Burns
To compare MW-III to Silvadene® Cream 1% (Silver Sulfadiazine) with respect to "time to healing" (≥95% re-epithelialization) of a partial thickness target thermal burn.
- Trial name
- NCT01297400
- Testing
- Investigational Drug, MW-III, Silvadene® Cream 1% [Silver Sulfadiazine]
- Where
- 6 sites in United States, Mexico
- Volunteers
- 60 people
- Sponsor
- Skingenix, Inc.
Burns, Burns Second Degree
CellMist™ Autologous Cells to Treat Deep Second-Degree Burns
The overall purpose of this study is to evaluate the safety of the CellMist™ System in the treatment of deep second degree burns (II°B) in a prospective, multicenter, feasibility pilot study.
- Conditions
- Burns, Burns Second Degree, Burns Deep Second Degree
- Trial name
- CELLMIST1 (NCT04890574)
- Testing
- CellMist™ System
- Where
- United States
- Volunteers
- 14 people
- Sponsor
- RenovaCare, Inc
Partial Thickness Burn of Hand
A Study to Evaluate the Efficacy of Cytal® Burn Matrix in the Management of Partial-Thickness Burns to the Hand
This is a randomized controlled trial (RCT) aimed at determining if use of Cytal® Burn Matrix in the management of partial-thickness burns to the hand shows improved wound healing times when compared to EZ-Derm Porcine Xenograft.
- Trial name
- NCT03598023
- Testing
- Cytal® Burn Matrix, EZ-Derm® Porcine Xenograft
- Sponsor
- Integra LifeSciences Corporation
Burn Wounds - Partial Thickness (2nd Degree)
Field Shield Wound Dressing Study
This study is to compare the Field Shield Wound Dressing (FSWD) as a treatment for burn wounds to a standard of care burn wound dressing to evaluate healing, infection, pain/discomfort, and deepening of wound over time.
- Trial name
- NCT07337616
- Testing
- Field Shield Wound Dressing, Silverlon
- Where
- 2 sites in United States
- Volunteers
- 40 people
- Sponsor
- KeriCure Medical
Skin Wound, Burns
StrataGraft Safety, Tolerability and Efficacy in Pediatric Subjects
Autografting is a surgical procedure to transplant healthy skin (donor skin) from another part of the participant's own body (donor site) to the burned part. Autografting is the usual treatment for DPT burns.
- Conditions
- Skin Wound, Burns, Trauma-related Wound
- Trial name
- StrataSTEPS (NCT05517902)
- Testing
- StrataGraft
- Where
- United States
- Volunteers
- 1 people
- Sponsor
- Stratatech, a Mallinckrodt Company
Surgical Wound, Trauma Wound
Randomized Controlled Trial to Investigate Clinical Outcomes and Associated Costs When PermeaDerm is Used as Temporary Dressing for Surgical Wounds
The goal of this study is to compare the cost and clinical outcomes for two temporary dressings (Allograft and PermeaDerm) used in patients that need a skin graft to heal their wound.
- Conditions
- Surgical Wound, Trauma Wound, Autografts, Partial-thickness Burn
- Trial name
- NCT06750809
- Testing
- PermeaDerm Biosynthetic Wound Matrix, Frozen Human Cadaveric Allograft (FHCA)
- Where
- 13 sites in United States
- Volunteers
- 40 people
- Sponsor
- Avita Medical