Clinical trials: Marginal Bone Loss
Jaw, Edentulous, Partially
Study to Compare Marginal Bone Loss Around Implants From Two Dental Implant Systems.
The purpose of this study is to compare marginal bone level changes between ASTRA TECH Implant System; Fixture ST and Biomet 3i; Osseotite® Implants.
- Trial name
- NCT00746187
- Testing
- ASTRA TECH Implant System; Fixture ST: Ø 4.5 cm in lengths of 9, 11 and 13 mm., 3i Osseotite® implant: Ø 4.0 in lengths of 8.5, 10, 11.5 and 13 mm
- Where
- 2 sites in United States
- Volunteers
- 36 people
- Sponsor
- Dentsply Sirona Implants and Consumables
Jaw, Edentulous, Partially
Study to Evaluate Implant Survival Rate of Astra Tech Fixture ST in the Posterior Maxilla With One-stage Surgery and Early Loading
The purpose of this study is primarily to evaluate implant survival rate of Astra Tech Fixture ST placed in the posterior maxilla.
- Trial name
- NCT00748241
- Testing
- Astra Tech Fixture ST
- Where
- 2 sites in United States
- Volunteers
- 19 people
- Sponsor
- Dentsply Sirona Implants and Consumables
Alveolar Process Atrophy
Marginal Bone and Soft Tissue Alterations After Use of OsseoSpeed EV Profile Implants
Evaluation of the marginal bone and soft tissue alterations after the OsseoSpeed™ EV Profile implants placement in anterior maxilla.
- Trial name
- NCT04243421
- Testing
- Implantation
- Where
- Poland
- Volunteers
- 30 people, healthy volunteers welcome
- Sponsor
- Medical University of Bialystok
Jaw, Edentulous, Partially
Study on OsseoSpeed™ Implants Replacing 2-5 Teeth in the Posterior Upper Jaw, Restored With Provisional Teeth Attached 6-7 Weeks Later
The purpose of the study is to evaluate Astra Tech Dental Implant System, Fixture Osseospeed™, in patients with tooth loss in the posterior maxilla in an early loading protocol.
- Trial name
- NCT00711113
- Testing
- OsseoSpeed™
- Where
- 3 sites in United States, Germany
- Volunteers
- 47 people
- Sponsor
- Dentsply Sirona Implants and Consumables
Gingival Tissue
Influence of Mucosa Tissue Thickness on Marginal Bone Loss of Implants With Smooth Collars
The primary objective of this study is to compare the amount of implant marginal bone loss radiographically and probing depth in between thin and thick mucosa group that will receive a machined collar implant.
- Trial name
- NCT02925078
- Testing
- Biohorizons Tapered Internal Implant, Laser-Lok, Resorbable Blast Textured (RBT)
- Where
- United States
- Volunteers
- 30 people, healthy volunteers welcome
- Sponsor
- University of Michigan
Jaw, Edentulous, Partially
Study on OsseoSpeed™ Implants in Patients Missing 2-5 Teeth in the Posterior Lower Jaw, Restored With Permanent Teeth Attached 6-7 Weeks Later
The purpose of the study is to evaluate Astra Tech Dental Implant System, Fixture Osseospeed™, in patients with tooth loss in the posterior mandible in an early loading protocol.
- Trial name
- NCT00711425
- Testing
- OsseoSpeed™
- Where
- 3 sites in United States, Germany
- Volunteers
- 45 people
- Sponsor
- Dentsply Sirona Implants and Consumables