Clinical trials: Fractures of the Upper Limb
Intra-Articular or Extra-Articular Distal Humerus Fracture, Distal Humerus Fracture
Clinical Outcomes After Treatment of Distal Humerus Fractures With the LORRAINE 2.5/3.5 mm Distal Humerus System
Distal humerus fractures are fractures of the lower part of the upper arm bone near the elbow. These fractures often require surgery using plates and screws to stabilize the bone while it heals.
- Trial name
- NCT07774091
- Testing
- LORRAINE 2.5/3.5 mm Distal Humerus System
- Where
- United States
- Volunteers
- 100 people
- Sponsor
- Bonebridge AG
Distal Radius Fractures
A Study Comparing the Effect of Amorphous Calcium Carbonate (ACC) on Healing Time of Distal Radius Fractures
Amorphical has a strong basis to believe that the Amorphous Calcium Carbonate (ACC) product has an effect on active mineralization during bone remodelling hence, it has a potential to accelerate fracture healing process.
- Trial name
- NCT01859468
- Testing
- Amorphous calcium carbonate
- Where
- 2 sites in Israel
- Volunteers
- 15 people
- Sponsor
- Amorphical Ltd.
Aseptic Loosening, Infection
Maxx Orthopedics' PCK Revision TKA Study of Component Survivorship
The objectives of this clinical investigation are to evaluate the safety and performance of the Freedom Total Knee® PCK System.
- Conditions
- Aseptic Loosening, Infection, Bone Loss, MCL - Medial Collateral Ligament Rupture of the Knee
- Trial name
- NCT03312088
- Testing
- Freedom Knee PCK Components
- Where
- United States
- Volunteers
- 300 people, healthy volunteers welcome
- Sponsor
- Maxx Orthopedics Inc
Hip Fracture
Safety and Efficacy of the WaisFix100i for Intracapsular Femoral Fracture Fixation
The purpose of this study is to determine the safety and efficacy of using WaisFix100i device for Intracapsular Femoral Fracture Fixation.
- Trial name
- NCT00521716
- Testing
- Intracapsular Femoral Fracture Fixation, WaisFix100i for Intracapsular Femoral Fracture Fixation
- Where
- Israel
- Volunteers
- 20 people
- Sponsor
- OrthoMediTec
Fracture Arm, Fracture Leg
Accuro XV Ultrasound Imaging System for BoneEnhance and Fracture Detection Algorithms
The Accuro XV is a cart-based, bedside ultrasound instrument that incorporates new signal processing-based technologies for enhanced bone and soft-tissue imaging.
- Conditions
- Fracture Arm, Fracture Leg, Wrist Injury, Ankle Injury
- Trial name
- NCT07853768
- Testing
- Accuro XV Ultrasound Imaging System
- Where
- 10 sites in United States
- Volunteers
- 25,000 people
- Sponsor
- Rivanna Medical, Inc.
Distal Radius Fractures
Proof-of-concept Study With NVDX3 for Treatment of Distal Radius Fractures.
Prospective, single arm, monocentric clinical study to test NVDX3 in patients suffering from distal radius fracture. NVDX3 will be implanted during a single surgical intervention.
- Trial name
- NCT05987033
- Testing
- NVDX3
- Where
- Luxembourg
- Volunteers
- 11 people
- Sponsor
- Novadip Biosciences
Ankle Fractures, Knee Fractures
Performance and Safety Follow-up of Bioabsorbable Headless Inion CompressOnTM Screws in the Fixation of Bone Fractures in Ankle, Knee and Elbow of Pediatric and Adolescent Patients
The study in question is a post market clinical follow up (PMCF) study to follow up the safety and performance of bioabsorbable headless compression screw Inion CompressOn in fracture fixation of the ankle, knee and elbow of…
- Conditions
- Ankle Fractures, Knee Fractures, Elbow Fractures
- Trial name
- NCT07473947
- Testing
- Fracture fixation operation
- Where
- Finland
- Volunteers
- 80 people
- Sponsor
- Inion Oy
Fractures, Bone, Nonunion of Fracture
Safety, Efficacy, & Use of ViviGen Cellular Bone Matrix Allograft in Orthopaedic Fracture Care
Prospective registry and retrospective data collection study to assess the efficacy and safety of Vivigen Cellular Bone Matrix (Vivigen) in orthopaedic trauma patients who require bone grafting in the acute, delayed, non-union…
- Conditions
- Fractures, Bone, Nonunion of Fracture, Fractures, Open, Fractures, Ununited
- Trial name
- NCT04299022
- Testing
- Vivigen Cellular Bone Matrix
- Where
- 4 sites in United States
- Volunteers
- 250 people
- Sponsor
- LifeNet Health
Osteoarthritis, Avascular Necrosis
A Clinical Investigation of the Comprehensive®, BioModular®, and Bi-Angular® Shoulder Systems
The purpose of this prospective clinical data collection is to document the performance and clinical outcomes of Biomet Humeral Stems
- Conditions
- Osteoarthritis, Avascular Necrosis, Rheumatoid Arthritis, Humeral Fractures
- Trial name
- NCT00699270
- Sponsor
- Biomet Orthopedics, LLC
Osteoarthritis, Rheumatoid Arthritis
A Clinical Investigation of the Discovery™ Elbow System
The purpose of this study is to perform a five-year, multi-center prospective evaluation of the Discovery™ Elbow System for outcome and durability.
- Conditions
- Osteoarthritis, Rheumatoid Arthritis, Avascular Necrosis, Humeral Fractures
- Trial name
- NCT00698867
- Where
- 4 sites in United States
- Volunteers
- 118 people
- Sponsor
- Biomet Orthopedics, LLC
Tibial Fracture, Femoral Fracture
Magnesium-Titanium Hybrid Intramedullary Nail System For Long Bone Fractures
This is a prospective, multicenter, randomized, controlled, non-inferiority clinical trial designed to evaluate the safety and effectiveness of the magnesium-titanium hybrid intramedullary nail system compared with the marketed…
- Conditions
- Tibial Fracture, Femoral Fracture, Humeral Fracture
- Trial name
- NCT07569575
- Testing
- Magnesium-Titanium Hybrid Intramedullary Nail System, Commercially Locked Metallic Intramedullary Nail
- Where
- 5 sites in China
- Volunteers
- 160 people
- Sponsor
- HuaMg Perfection Med Tech (Suzhou) Co., Ltd.
Osteopenia, Osteoporosis
Extension Study to Evaluate the Long Term Safety and Efficacy of Denosumab in the Treatment of Osteoporosis
The primary objective was to describe the safety and tolerability of up to 10 years or 7 years denosumab administration as measured by adverse event monitoring, immunogenicity and safety laboratory parameters in participants who…
- Trial name
- NCT00523341
- Testing
- Denosumab
- Volunteers
- 4,550 people
- Sponsor
- Amgen
Humeral Fractures, Pathological Fractures
Intramedullary Fixation of Humerus Fractures Without Intramedullary Reaming
The purpose of the study is to evaluate the safety and efficacy of the composite Nail - the Quantum interlocking intramedullary nailing system in the reduction of humeral fractures.
- Trial name
- NCT01087463
- Testing
- Quantum
- Where
- Israel
- Volunteers
- 20 people
- Sponsor
- N.M.B. Medical Applications Ltd
Distal Radius Fracture, Distal Ulna Fracture
PMCF Study on the Safety, Performance and Clinical Benefits of the DVR Plating System
The study is a single-center, retrospective, non-randomized, non-controlled and consecutive series post-market study. The purpose of this study is to confirm safety, performance and clinical benefits of the DVR Plates.
- Conditions
- Distal Radius Fracture, Distal Ulna Fracture, Osteotomy
- Trial name
- NCT04653051
- Where
- United Kingdom
- Volunteers
- 111 people
- Sponsor
- Zimmer Biomet
Humeral Fractures, Pathological Fractures
Intramedullary Fixation of Humerus Fractures
The purpose of the study is to evaluate the safety and efficacy of the composite Nail - the Quantum interlocking intramedullary nailing system in the reduction of humeral fractures.
- Trial name
- NCT01017289
- Testing
- Quantum
- Where
- Israel
- Volunteers
- 20 people
- Sponsor
- N.M.B. Medical Applications Ltd
Wrist Fracture, Proximal Humerus Fracture
PMCF Study on the Safety, Performance and Clinical Benefits Data of the XtraFix® Small External Fixation System
The study is a monocentric, retrospective, non-randomized, non-controlled and consecutive series post-market study. The purpose of this study is to confirm safety, performance and clinical benefits of the XtraFix® Small External…
- Trial name
- NCT05943574
- Where
- Italy
- Volunteers
- 91 people
- Sponsor
- Zimmer Biomet
Degenerative Conditions of the Radial Head/Neck, Post-traumatic Conditions of the Radial Head/Neck
ExploR® Modular Radial Head Data Collection
The purpose of this prospective clinical data collection is to document the performance and clinical outcomes of the ExploR® Modular Radial Head. This data collection effort will document the clinical outcomes of the radial head.
- Trial name
- NCT00533234
- Testing
- ExploR® Modular Radial Head
- Where
- United States
- Volunteers
- 4 people
- Sponsor
- Biomet Orthopedics, LLC
Delirium
A Research Study to Evaluate the Effectiveness of Dexmedetomidine in Preventing Delirium After Hip Fracture Repair Surgery
The purpose of this study is to evaluate the efficacy and safety of perioperative use of dexmedetomidine in the prevention of postoperative delirium in subjects undergoing surgery for fractured hip with general anesthesia.
- Trial name
- NCT00460473
- Testing
- Dexmedetomidine
- Where
- 30 sites in United States
- Volunteers
- 52 people
- Sponsor
- Hospira, now a wholly owned subsidiary of Pfizer
Fracture Fixation, Internal, Distal Radius Fracture
RemeOs™ DrillPin for Fixation of Distal Radius Fractures in Children
This is a pre-market, single-arm, open-label, monocenter clinical investigation evaluating the safety and performance of the magnesium (Mg)-based bioresorbable RemeOs™ DrillPin for surgical fixation of distal radius fractures in…
- Trial name
- NCT07028541
- Testing
- Magnesium-based bioresorbable DrillPin for fixation of distal radius fractures in children
- Volunteers
- 20 people
- Sponsor
- Bioretec Ltd.
Osteoarthritis, Rheumatoid Arthritis
A Clinical Investigation of the Copeland™ Humeral Resurfacing Head
The purpose of this study is to perform a five-year, prospective evaluation of the Copeland™ Humeral Resurfacing Head Prosthesis for outcome and durability.
- Conditions
- Osteoarthritis, Rheumatoid Arthritis, Avascular Necrosis, Humeral Fractures
- Trial name
- NCT00698750
- Volunteers
- 34 people
- Sponsor
- Biomet Orthopedics, LLC