Clinical trials: Fractured Scaphoid Bone
Intact Scaphoid Bone, Intact Metacarpal Bone
Bone Microcirculation After Extracorporeal Shock Wave Therapy
In trauma surgery and hand surgery treatment strategies of none healing bone fractures aim at replacing pseudarthrosis by well vascularized bone and improving microcirculation.
- Conditions
- Intact Scaphoid Bone, Intact Metacarpal Bone, Fractured Scaphoid Bone, Fractured Metacarpal Bone
- Trial name
- NCT02424084
- Testing
- Extracorporeal Shock Wave Therapy (Device Name: PiezoWave)
- Where
- Germany
- Volunteers
- 80 people, healthy volunteers welcome
- Sponsor
- University Hospital Schleswig-Holstein
Scaphoid Fracture
Pilot Study to Test the Feasibility of the Use of MRI in Suspected Scaphoid Fractures
This pilot study aims to test the feasibility and work flows associated with using MRI as the initial imaging modality in the investigation of patients presenting with suspected scaphoid fracture.
- Trial name
- NCT02605096
- Testing
- MRI, X-ray
- Volunteers
- 10 people
- Sponsor
- Guy's and St Thomas' NHS Foundation Trust
Non-displaced Scaphoid Fractures
Cast Immobilization for Non-Displaced Scaphoid Fractures
This trial is trying to understand if immobilization of the thumb after a non-displaced scaphoid fracture affects recovery. The standard of care overseas is a cast that allows for free movement of the thumb, and in the United…
- Trial name
- NCT00916539
- Testing
- Cast that immobilizes the thumb, Cast that does not immobilize the thumb
- Where
- United States
- Volunteers
- 62 people
- Sponsor
- Massachusetts General Hospital
Distal Tubercle Fractures of the Scaphoid
Symptomatic Treatment of Distal Tubercle Fractures of the Scaphoid
AIM: The aim of this study is to assess whether patients with an acute distal tubercle fracture of the scaphoid treated with a removable brace for 4 to 6 weeks have the same level of symptoms and disability 6 months after injury…
- Trial name
- NCT02366234
- Sponsor
- Massachusetts General Hospital
Acute Scaphoid Waist Fractures
Fluoroscopy vs. Computed Tomography for Diagnosis of Displacement and Instability of Acute Scaphoid Waist Fractures
Aim: The aim of this study is to analyze if fluoroscopy is as accurate as computed tomography in diagnosing displacement of acute scaphoid waist fractures.
- Trial name
- NCT02479009
- Testing
- Fluoroscopy
- Sponsor
- Massachusetts General Hospital
Scaphoid Non-union Advanced Collapse (SNAC Wrist)
The Use of Adaptive Proximal Scaphoid Implant (APSI): Long Term Follow-up
Scaphoid proximal pole fracture with avascular necrosis is a complex surgical problem. In some cases, it's possible to perform a scaphoid hemiarthroplasty with an adaptative proximal scaphoid implant (APSI), made of pyrocarbon…
- Trial name
- NCT06808594
- Testing
- APSI prosthesis implant
- Volunteers
- 36 people
- Sponsor
- Azienda Ospedaliera Universitaria Integrata Verona
Scaphoid Fracture
Percutaneous Fixation of Acute Scaphoid Fractures
Percutaneous Trans-trapezial fixation of acute Scaphoid fractures by Herbert screw
- Trial name
- NCT04776551
- Testing
- Percutaneous fixation of acute Scaphoid fractures
- Where
- Egypt
- Volunteers
- 20 people
- Sponsor
- Sohag University
Distal Radius Fracture, Scaphoid Fracture
Use of Digital Tomosynthesis for Detection and Case Management of Scaphoid and Distal Radius Fractures: A VolumeRAD Data Collection Study
The study described herein is being conducted to collect clinical data associated with diagnosis and treatment information using the VolumeRAD advanced application.
- Trial name
- NCT03856450
- Testing
- DTS, X-ray, MRI or CT
- Where
- United States
- Volunteers
- 140 people, healthy volunteers welcome
- Sponsor
- GE Healthcare
Wrist Fracture, Scaphoid Fracture
Fast Track for Wrist and Scaphoid Fractures
This is a mono centric, prospective, randomised trial on the implementation and assessment of a shortened pathway for mono-trauma of the wrist and suspected fracture of distal radius and/or ulna and/or scaphoid bone.
- Trial name
- NCT05183477
- Testing
- fast track, normal pathway
- Where
- Switzerland
- Volunteers
- 196 people
- Sponsor
- Ente Ospedaliero Cantonale, Bellinzona
Nonunion of Fracture of Scaphoid Bone, Fractures, Ununited
Scaphoid Non-union and Low-intensity Pulsed Ultrasound Trial
This is a prospective, double-blind, multicentered, randomized controlled trial to determine the effectiveness of low-intensity pulsed ultrasound in decreasing the time to union of scaphoid non-unions after operative fixation as…
- Trial name
- SNAPU (NCT02383160)
- Testing
- Bioventus Exogen 4000: Low-intensity pulsed ultrasound
- Where
- 6 sites in Canada
- Volunteers
- 154 people
- Sponsor
- University of Calgary
Union, Scaphoid
Union Rate of Scaphoid Non-Union Fracture in Adults by Herbert Screw Versus Volar Buttress Plate
This study aimed to evaluate the short-term results of treating non-united scaphoid waist fractures with a humpback deformity by graft and internal fixation using a volar buttress plate versus the use of a Herbert screw.
- Conditions
- Union, Scaphoid, Non-Union Fracture, Herbert Screw
- Trial name
- NCT07039695
- Testing
- Volar buttress plate, Herbert screw
- Where
- Egypt
- Volunteers
- 30 people
- Sponsor
- Helwan University
Orthopedic
Long-term Surgical Outcomes of Scaphoid Proximal Pole Fracture Nonunion
The treatment for scaphoid proximal pole nonunion remains challenging due to the poor vascularity in the proximal pole fragment, associated SL injury and the technique of fixation.
- Trial name
- NCT03701269
- Where
- Taiwan
- Volunteers
- 10 people
- Sponsor
- Taipei Veterans General Hospital, Taiwan
Scaphoid Fractures, Distal Radius Fractures
Prospective Clinical Trial Comparing Infraclavicular Versus Axillary Approach to Brachial Plexus Block
The brachial plexus block is an anesthetic technique often used for surgical procedures of the upper limb. To get the brachial plexus block, several routes can be used, including the axillary and infraclavicular approach.
- Conditions
- Scaphoid Fractures, Distal Radius Fractures, Wrist Injury Arthrodesis
- Trial name
- NCT02208245
- Testing
- Ultrasound: Axillary block, Ultrasound: Infraclavicular block, Ropivacaine
- Where
- Brazil
- Volunteers
- 46 people
- Sponsor
- Federal University of São Paulo
Medial Malleolus Fracture, Lisfranc Injury
Performance and Safety Evaluation of Inion CompressOn Screw in Foot and Ankle Surgeries. PMCF Investigation
The study in question is a post market clinical follow up (PMCF) study to evaluate the safety and performance of bioabsorbable headless compression screw Inion CompressOn in selected fracture, osteotomy and arthrodeses operations…
- Conditions
- Medial Malleolus Fracture, Lisfranc Injury, Lisfranc Fracture, Talus Fracture
- Trial name
- NCT05555459
- Testing
- Operation
- Where
- Finland
- Volunteers
- 125 people
- Sponsor
- Inion Oy
Fracture
Wrist Fracture Evaluation With a Desktop Orthopedic Tomosynthesis System
Trauma to the extremities such wrist, ankle, limb is very common and affects all population groups. It constitutes a significant public health issue. Standard radiography remains the basic imaging tool.
- Trial name
- NCT03993691
- Testing
- Tomo-E scan, Radiograph
- Where
- United States
- Volunteers
- 30 people
- Sponsor
- University of North Carolina, Chapel Hill
Scaphoid Fracture
Operative Versus Conservative Treatment of Scaphoid Fractures
The aim of this study is to compare the time to return to previous activity level between operative treatment and non-operative cast immobilization of patients with an acute complete fracture of the middle part of the scaphoid…
- Trial name
- NCT00205985
- Testing
- Scaphoid screw
- Where
- Germany
- Volunteers
- 100 people
- Sponsor
- AO Clinical Investigation and Publishing Documentation