Clinical trials: Dissection, Aortic
Aortic Dissection Involving the Descending Thoracic Aorta
Clinical Study to Assess Safety and Effectiveness of the Zenith® Dissection Endovascular System in Patients With Aortic Dissection
The purpose of this study is to evaluate the safety and effectiveness performance of the Zenith® Dissection Endovascular System in the treatment of aortic dissections involving the descending thoracic aorta.
- Trial name
- NCT00526487
- Testing
- Zenith® Dissection Endovascular System, Endovascular Repair
- Where
- 8 sites in Australia, Czechia and 3 more
- Volunteers
- 60 people
- Sponsor
- William Cook Europe
Thoracic Aortic Aneurysm, Thoracic Aorta Injury
CTAG Dissection/Trauma Post Marketing Surveillance Japan
Post Marketing Surveillance of the Conformable GORE® TAG® Thoracic Endoprosthesis
- Conditions
- Thoracic Aortic Aneurysm, Thoracic Aorta Injury, Thoracic Aortic Dissection
- Trial name
- NCT05414318
- Testing
- Conformable GORE® TAG® Thoracic Endoprosthesis
- Volunteers
- 55 people
- Sponsor
- W.L.Gore & Associates
Retinal Detachment, Achilles Tendon
A Study of Fluoroquinolones Exposure and Collagen-Related Serious Adverse Events
The purpose of this study is to evaluate whether there is an increased risk of achilles tendon rupture (ATR), retinal detachment (RD) or aortic aneurysm and dissection (AAD) following exposure to fluoroquinolone (FQ) or other…
- Conditions
- Retinal Detachment, Achilles Tendon, Aneurysm, Dissecting
- Trial name
- NCT03479736
- Testing
- Oral Fluoroquinolones (FQ), Other Antibiotics, Febrile Illness Not Treated with Antibiotics Will be Analyzed as an Exposure
- Where
- United States
- Volunteers
- 117,911 people
- Sponsor
- Janssen Research & Development, LLC
Type B Aortic Dissection
Guo's Subclavian Artery Reconstruction: The Prospective, Multiple Center Study of WeFlow-Tbranch Stent Graft System(GUEST Study)
This study is a prospective, multiple center study to evaluate the safety and effectiveness of WeFlow-Tbranch single embedded branch thoracic aorta stent graft system manufactured by EndoNom Medtech (Hangzhou) Co., Ltd.
- Trial name
- NCT04765605
- Testing
- WeFlow-Tbranch Stent Graft System
- Where
- 29 sites in China
- Volunteers
- 120 people
- Sponsor
- Hangzhou Endonom Medtech Co., Ltd.
Aneurysm, Dissection
PANTHER Study of Terumo Aortic Knitted and Woven Grafts, and Cardiovascular Patches
The purpose of this registry is to collect safety and performance data on all commercially available Terumo Aortic knitted and woven grafts, and cardiovascular patches in standard clinical practice.
- Conditions
- Aneurysm, Dissection, Aortic Root Aneurysm, Aortic Root Dissection
- Trial name
- PANTHER (NCT04545502)
- Testing
- Gelsoft Plus Vascular Graft, Vascular Bypass Graft, Cardiovascular Patch
- Where
- 30 sites in United States, Belgium and 4 more
- Volunteers
- 2,000 people
- Sponsor
- Vascutek Ltd.
Aortic Dissection Type B
WeFlow-EndoSeal™ Aorta Vascular Plug System for the Treatment of Stanford Type B Aortic Dissection
The goal of this prospective, multicenter, randomized controlled clinical trial is to evaluate the safety and efficacy of the WeFlow-EndoSeal™ vAorta Vascular Plug System combined with thoracic endovascular aortic repair (TEVAR)…
- Trial name
- NCT07658651
- Testing
- WeFlow-EndoSeal™ Aorta Vascular Plug System, Thoracic Endovascular Aortic Repair(TEVAR)
- Where
- China
- Volunteers
- 256 people
- Sponsor
- Hangzhou Endonom Medtech Co., Ltd.
Aortic Aneurysm, Thoracic, Descending Thoracic Aortic Dissection
Valiant Thoracic Stent Graft With the Captivia Delivery System in the Treatment of Descending Thoracic Aortic Diseases (VALIANT CAPTIVIA France)
The objective of this study is to assess the benefits of endovascular technique in terms of efficacy and safety of Valiant Thoracic Stent Graft with the Captivia Delivery System in the treatment of thoracic aortic disease, in a…
- Conditions
- Aortic Aneurysm, Thoracic, Descending Thoracic Aortic Dissection, Penetrating Ulcer, Aorta Thoracic; Traumatic Rupture
- Trial name
- NCT01775046
- Testing
- DTA patients (Valiant)
- Where
- 17 sites in France
- Volunteers
- 160 people
- Sponsor
- Medtronic Cardiovascular
Aortic Diseases
INSTEAD Trial: INvestigation of STEnt Grafts in Patients With Type B Aortic Dissection
The objective of this study is to compare treatment with an endograft prothesis versus antihypertensive treatment in patients with a dissection of the thoracic aorta.
- Trial name
- INSTEAD (NCT00525356)
- Testing
- Medtronic Talent Stent-Graft-System
- Where
- Netherlands
- Volunteers
- 136 people
- Sponsor
- Medtronic Cardiac Rhythm and Heart Failure
Aortic Dissection
Zenith® TXD Post-market Surveillance in Japan
The study is a post-market surveillance study required by Japanese Regulatory Authorities as a condition of approval
- Trial name
- NCT02663739
- Testing
- Zenith® TXD
- Where
- 27 sites in Japan
- Volunteers
- 57 people
- Sponsor
- Cook Group Incorporated
Thoracic Aortic Dissection
Post-market Clinical Trial of the Dominus® Stent-Graft
Real-world clinical trial evidence post-market, evaluating the safety and efficacy of the Dominus® StentGraft Endoprosthesis in treating thoracic aortic diseases, following the Instructions for Use
- Trial name
- DominusPMCF (NCT06270537)
- Testing
- Stent-Graft Dominus® Endoprosthesis
- Where
- 3 sites in Brazil
- Volunteers
- 100 people
- Sponsor
- Braile Biomedica Ind. Com. e Repr. Ltda.
Aortic Dissection
A Real World Study on Fabulous® Thoracic Aortic Stent System for Stanford B Aortic Dissection
A multicenter, retrospective study to evaluate the real-world efficacy of the Fabulous thoracic aortic stent system in the treatment of Stanford Type B aortic dissection.
- Trial name
- NCT05965271
- Testing
- Fabulous Thoracic Aortic Stent System
- Where
- 7 sites in China
- Volunteers
- 260 people
- Sponsor
- Hangzhou Endonom Medtech Co., Ltd.
Penetrating Ulcer of Aorta, Aneurysm Aortic
Evaluation of the Valiant Captivia Physician Fenestrated Stent Graft System in Aortic Arch and Descending Thoracic Aorta Pathologies
The study objectives are to assess safety and effectiveness, measured acutely and at the 30-day visit after implantation of the Valiant Captivia physician fenestrated Stent Graft.
- Conditions
- Penetrating Ulcer of Aorta, Aneurysm Aortic, Type B Aortic Dissection, Residual Dissection After Type A Repair
- Trial name
- EVERGREEN (NCT05479305)
- Testing
- The Valiant Captivia Stent Graft
- Where
- 4 sites in France
- Volunteers
- 30 people
- Sponsor
- Ceric Sàrl
Aneurysm Thoracic, Dissection of Thoracic Aorta
Ankura™ TAA Stent Graft System Post-Market Clinical Follow-up Study
The purpose of this study is to collect clinical data on patient outcomes, evaluate the safety and performance of Ankura TAA Stent Graft System and Surpass Super Stiff Guidewire, and build clinical evidence for patients with…
- Trial name
- NCT05639569
- Testing
- Ankura™ TAA Stent Graft System
- Where
- 15 sites in Germany, Greece and 3 more
- Volunteers
- 147 people
- Sponsor
- Lifetech Scientific (Shenzhen) Co., Ltd.
Aortic Aneurysm, Thoracic, Chronic Type B Dissection
Evaluation of the Valiant Mona LSA Thoracic Stent Graft System in Descending TAA and Chronic Dissections
The purpose of the Feasibility study is to characterize the safety of the Valiant Mona LSA Thoracic Stent Graft System, including an assessment of the safety and effectiveness of the device acutely and at the 30 day visit in the…
- Trial name
- NCT02365467
- Testing
- Valiant Mona LSA Thoracic Stent Graft System
- Where
- United States
- Volunteers
- 32 people
- Sponsor
- Medtronic Cardiovascular
Thoracic Diseases, Aortic Aneurysm
Thoraflex Hybrid and Relay Extension Post-Approval Study
The goal of this observational study is to evaluate the Thoraflex Hybrid device alone and in combination with the RelayPro NBS stent-graft in the treatment of aortic disease affecting the aortic arch and descending aorta with or…
- Conditions
- Thoracic Diseases, Aortic Aneurysm, Aortic Dissection, Thoracic Aortic Aneurysm
- Trial name
- EXTEND (NCT05639400)
- Testing
- Thoraflex Hybrid, RelayPro NBS
- Where
- 27 sites in United States, Austria and 5 more
- Volunteers
- 352 people
- Sponsor
- Vascutek Ltd.
Vascular Diseases
Prospective/Retrospective Registry of the E-vita OPEN PLUS Stent Graft System in France
The FEOR registry is undertaken to examine the real-world data of patients that were treated with the E-vita OPEN Plus Stent Graft System under routine care in France.
- Trial name
- FEOR (NCT04058691)
- Testing
- Surgical repair
- Where
- 2 sites in France
- Volunteers
- 100 people
- Sponsor
- JOTEC GmbH
Aortic Dissection, Aneurysm, Dissecting
The Branch-based Intraoperative Stent System in the Treatment of Stanford A Aortic Dissection(BROAD)
The purpose of the study was to evaluate the safety and efficacy of a branched type intraoperative stent system for the treatment of Stanford type A aortic dissection
- Conditions
- Aortic Dissection, Aneurysm, Dissecting, Aneurysm, Vascular Diseases
- Trial name
- BROAD (NCT05659641)
- Testing
- PerMed Stent Graft System In Surgical Operation, Endovastec CRONUS® Intraoperative stent system
- Where
- 18 sites in China
- Volunteers
- 259 people
- Sponsor
- Permed Biomedical Engineering Co., Ltd
Aortic Dissection, Acute DeBakey I Dissection
Post-market Registry of the AMDS for the Treatment of Acute DeBakey Type I Dissection
The objective of this registry is to collect information on the performance and clinical benefits of the AMDS (Ascyrus Medical Dissection Stent) to treat patients with acute "DeBakey type I dissections" and with or without so…
- Conditions
- Aortic Dissection, Acute DeBakey I Dissection, Acute Type A Dissection, Intramural Hematoma
- Trial name
- PROTECT (NCT03894033)
- Testing
- Ascyrus Medical Dissection Stent (AMDS)
- Where
- Germany
- Volunteers
- 301 people
- Sponsor
- JOTEC GmbH
Thoracic Aortic Aneurysm, Penetrating Aortic Ulcers (PAUs)
MBA Early Feasibility Study
The MBA 25-04 study is a prospective, multicenter, non-randomized, single-arm, early feasibility study designed to assess the initial safety of the MBA device through five years following the index endovascular procedure.
- Conditions
- Thoracic Aortic Aneurysm, Penetrating Aortic Ulcers (PAUs), Thoracic Aortic Dissection, Pseudoaneurysm
- Trial name
- NCT07564375
- Testing
- GORE® Multibranch Arch Endoprosthesis, GORE® Ascending Stent Graft
- Where
- 3 sites in United States
- Volunteers
- 20 people
- Sponsor
- W.L.Gore & Associates
Aortic Dissection
Safety and Efficacy Study Of The Thoracic Aortic Stent Graft System Treating Aortic Dissection
This is a prospective, multicenter and single-arm trail to study the safety and efficacy of the thoracic aortic stent graft system that specially designed for treating aortic dissection.
- Trial name
- NCT05430672
- Testing
- The Thoracic Aortic Stent Graft System (Zylox-Tonbridge Medical Technology Co., Ltd. )
- Where
- 14 sites in China
- Volunteers
- 120 people
- Sponsor
- Zhejiang Zylox Medical Device Co., Ltd.