Clinical trials: Aortic Dissection Type A
Aortic Dissection
GORE® Ascending Stent Graft in the Treatment of De Novo Type A Aortic Dissections
To assess the safety and effectiveness of the ASG device in the treatment of de novo Type A aortic dissections.
- Trial name
- ARISE III (NCT06827990)
- Testing
- GORE® Ascending Stent Graft (ASG device)
- Where
- 22 sites in United States
- Volunteers
- 112 people
- Sponsor
- W.L.Gore & Associates
Aortic Dissection
A Real-World Study on Distal Aortic Remodeling for Stanford Type B Aortic Dissection With Fabulous Thoracic Aortic Stent System
To evaluate aortic remodeling of Fabulous thoracic aortic stent system in the treatment of acute and subacute Stanford type B aortic dissection (the changes of aortic diameter, cross-sectional area,and volume of true lumen, false…
- Trial name
- NCT05883592
- Testing
- Fabulous Thoracic Aortic Stent System
- Where
- 2 sites in China
- Volunteers
- 50 people
- Sponsor
- Hangzhou Endonom Medtech Co., Ltd.
Aortic Diseases
A European Study on Medical Management Versus TAG Device + Medical Management for Acute Uncomplicated Type B Dissection
The purpose of this study is to compare endoluminal stent grafting with the GORE TAG device and Best Medical Therapy (BMT) to BMT alone in the treatment of acute uncomplicated type B aortic dissections.
- Trial name
- ADSORB (NCT00742274)
- Testing
- Gore TAG Endoprosthesis, Best Medical Therapy
- Volunteers
- 61 people
- Sponsor
- W.L.Gore & Associates
Acute Aortic Dissection
PERSEVERE- A Trial to Evaluate AMDS in Acute DeBakey Type I Dissection
Prospective, non-randomized, multicenter clinical investigation to assess the safety and effectiveness of AMDS in the treatment of patients with acute DeBakey type I dissection, with evidence of malperfusion, through open…
- Trial name
- PERSEVERE (NCT05174767)
- Testing
- AMDS
- Where
- 25 sites in United States
- Volunteers
- 115 people
- Sponsor
- Artivion Inc.
Type B Aortic Dissection
A Study in SurvIvors of Type B Aortic Dissection Undergoing Stenting
Cohort study according to national regulatory guidelines: Non-interventional, observational cohort study. Pair-matched comparison with patients chosen from historical series.
- Trial name
- ASSIST (NCT01407159)
- Where
- 15 sites in Germany, Italy and 2 more
- Volunteers
- 40 people
- Sponsor
- JOTEC GmbH
Vascular Ehlers-Danlos Syndrome
Investigate Efficacy, Safety, and Pharmacokinetics of Enzastaurin for the Prevention of Arterial Events in Patients With Vascular Ehlers-Danlos Syndrome.
The purpose of this study is to investigate the efficacy of enzastaurin compared to placebo in preventing arterial events (rupture, dissection, pseudoaneurysm, carotid-cavernous sinus fistula, or aneurysm, fatal or not) leading…
- Trial name
- PREVEnt (NCT05463679)
- Testing
- Enzastaurin
- Where
- United States
- Volunteers
- 260 people
- Sponsor
- Aytu BioPharma, Inc.
Aortic Dissection Type B
Study of the RelayPro Thoracic Stent-Graft in Subjects With an Acute, Complicated Type B Aortic Dissection
This clinical trial is a prospective, multicenter, non-blinded, non-randomized study designed to assess the RelayPro thoracic endografts in the treatment of acute, complicated type B aortic dissection.
- Trial name
- NCT03033043
- Testing
- Relay Pro Stent-Graft
- Where
- 21 sites in United States
- Volunteers
- 56 people
- Sponsor
- Bolton Medical
Aortic Dissection Type B
Safety and Efficacy Study of Fabulous Stent Graft System for Stanford B Aortic Dissection
A prospective, multi-center, objective performance criteria clinical trial to evaluate the safety and efficacy of Fabulous Stent Graft System manufactured by Hangzhou Endonom Medtech Co., Ltd. for Stanford B Aortic Dissection.
- Trial name
- NCT04918212
- Testing
- Fabulous Stent Graft System
- Where
- 24 sites in China
- Volunteers
- 148 people
- Sponsor
- Hangzhou Endonom Medtech Co., Ltd.
Aortic Dissection, Acute DeBakey I Dissection
Post-market Registry of the AMDS for the Treatment of Acute DeBakey Type I Dissection
The objective of this registry is to collect information on the performance and clinical benefits of the AMDS (Ascyrus Medical Dissection Stent) to treat patients with acute "DeBakey type I dissections" and with or without so…
- Conditions
- Aortic Dissection, Acute DeBakey I Dissection, Acute Type A Dissection, Intramural Hematoma
- Trial name
- PROTECT (NCT03894033)
- Testing
- Ascyrus Medical Dissection Stent (AMDS)
- Where
- Germany
- Volunteers
- 301 people
- Sponsor
- JOTEC GmbH
Penetrating Ulcer of Aorta, Aneurysm Aortic
Evaluation of the Valiant Captivia Physician Fenestrated Stent Graft System in Aortic Arch and Descending Thoracic Aorta Pathologies
The study objectives are to assess safety and effectiveness, measured acutely and at the 30-day visit after implantation of the Valiant Captivia physician fenestrated Stent Graft.
- Conditions
- Penetrating Ulcer of Aorta, Aneurysm Aortic, Type B Aortic Dissection, Residual Dissection After Type A Repair
- Trial name
- EVERGREEN (NCT05479305)
- Testing
- The Valiant Captivia Stent Graft
- Where
- 4 sites in France
- Volunteers
- 30 people
- Sponsor
- Ceric Sàrl
Vascular Diseases
A Study in Patients With Complicated Type B Aortic Dissection Treated With the E-nya Thoracic Stent Graft
The CONFORM-TAD post-market clinical follow-up study is undertakento evaluate the prevention of death related to the treatment of a complicated acute, subacute or chronic type B aortic dissection with the E-nya Thoracic Stent…
- Trial name
- CONFORM-TAD (NCT04378361)
- Testing
- endovascular repair
- Where
- Germany
- Sponsor
- JOTEC GmbH
Vascular Ehlers-Danlos Syndrome
Clinical Trial to Compare the Efficacy of Celiprolol to Placebo in Patients With Vascular Ehlers-Danlos Syndrome
This is a prospective, Phase 3, randomized, double-blind, placebo-controlled efficacy study to evaluate celiprolol in patients genetically confirmed as COL3A1-positive vEDS using a decentralized clinical trial design.
- Trial name
- DiSCOVER (NCT05432466)
- Testing
- ACER-002 (celiprolol) 200 mg BID
- Where
- United States
- Volunteers
- 150 people
- Sponsor
- Acer Therapeutics Inc.
Cardiovascular Procedures, Thoracic Aortic Aneurysm
Post Market Surveillance Study Evaluating BioFoam Surgical Matrix in Cardiovascular Surgery
This is a prospective, multicenter, single-arm study designed to collect clinical data to support the safety and effectiveness of BioFoam used as a surgical adjunct to anastomotic hemostasis following cardiovascular surgery.
- Conditions
- Cardiovascular Procedures, Thoracic Aortic Aneurysm, Aortic Valve Replacement, Type A Aortic Dissection
- Trial name
- NCT02164201
- Where
- 2 sites in Germany, Italy
- Volunteers
- 75 people
- Sponsor
- CryoLife Europa
Type B Aortic Dissection
EXtensive mulTilayer stEnt treatmeNt in Aortic disSectiOn
This clinical trial is a prospective, multicenter, open label study designed to evaluate the effectiveness and the safety of the Allay® Aortic Stent as adjunctive endovascular treatment of Type B aortic dissection in patients…
- Trial name
- EXTENSO (NCT06675617)
- Testing
- Allay Aortic Stent
- Where
- 21 sites in Austria, Belgium and 6 more
- Volunteers
- 72 people
- Sponsor
- Intressa Vascular SA
Type A Aortic Dissection
BioGlue as an Adjunct for Structural Repair and Hemostasis in Chinese Acute Type A Aortic Dissections Patients
A multi-center, randomized, controlled clinical trial is designed to investigate the safety and efficacy of BioGlue as an adjunct for structural repair and hemostasis to traditional surgical repair in Chinese subject with Acute…
- Trial name
- CHINA (NCT03369977)
- Testing
- BioGlue Surgical Adhesive, Traditional Surgical Repair
- Where
- 7 sites in China
- Volunteers
- 202 people
- Sponsor
- CryoLife, Inc.
Aortic Dissection Type B
WeFlow-EndoSeal™ Aorta Vascular Plug System for the Treatment of Stanford Type B Aortic Dissection
The goal of this prospective, multicenter, randomized controlled clinical trial is to evaluate the safety and efficacy of the WeFlow-EndoSeal™ vAorta Vascular Plug System combined with thoracic endovascular aortic repair (TEVAR)…
- Trial name
- NCT07658651
- Testing
- WeFlow-EndoSeal™ Aorta Vascular Plug System, Thoracic Endovascular Aortic Repair(TEVAR)
- Where
- China
- Volunteers
- 256 people
- Sponsor
- Hangzhou Endonom Medtech Co., Ltd.
Aortic Dissection
ARISE: Evaluation of the GORE® Ascending Stent Graft in the Treatment of DeBakey Type I/II Aortic Dissection
Assess the feasibility of the treatment of DeBakey Type I/II aortic dissections with the GORE® Ascending Stent Graft
- Trial name
- NCT02380716
- Testing
- GORE® Ascending Stent Graft
- Where
- United States
- Volunteers
- 21 people
- Sponsor
- W.L.Gore & Associates