AzTrials
AzTrials

BreastfeedingMILQ premNCT07908238

Maximising Maternal Milk for Preterm Infant

A study testing Hospital grade double electrical breast milk pump in people with Breastfeeding and Prematurity, run by National Maternity Hospital, Ireland at 3 sites in Ireland.

Recruiting

Looking for participants now. Contact the study team or a site below to ask about taking part.

Sites and contacts
Official record
Search all trials

Trial summary

Maternal milk is the gold standard in infant nutrition, providing significant advantages, in preterm and term infants. Maternal milk plays a major role in reducing the risk of inflammatory bowel disease(NEC) in premature and low birth weight infants as well as improving neurodevelopmental outcomes in this population… Read more about this study

Who is it for?
Any age, women only
Conditions the study is for
Breastfeeding, Prematurity
What is being tested?
Hospital grade double electrical breast milk pump
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
160 participants
Where
3 sitesIreland
Study dates
7 Nov 2025to 1 Sep 2027
Phase
Interventional
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages Any age
  • Women only
  • No healthy volunteers
  • Child, Adult, Older adult

Who may be able to join

  • The infant/s are born at the National Maternity Hospital with a gestational age at birth < 33 weeks by best obstetric estimate or with a birth weight of < 1500g; or
  • The infant/s are born in another centre with a gestational age at birth < 33 weeks by best obstetric estimate and/or with a birth weight of < 1500g and the mother is admitted to the National Maternity Hospital within 24 hours of delivery

Who cannot join

  • Breast milk use in the infant is contraindicated
  • There is breast hypoplasia on examination or recent breast surgery affecting ability to produce adequate breast milk

Trial locations and contacts

3 sites in 1 country. Contact the study team or a site near you to ask about taking part.

Anna Curley, Consultant Neonatologist contact

003531637300

anna.curley@nmh.ie

Sarah Kasha, Consultant Neonatology contact

00353876111218

sarah.kasha@nmh.ie

Ireland3 sites, 2 recruiting
  • National Maternity Hospital

    Dublin, Co. Dublin, D02YH21

    Anna Curley, Consultant Neonatology, 00353, anna.curley@nmh.ie

    Anna Curley, Consultant Neonatology, 003531637300, anna.curley@nmh.ie

    Not yet recruiting
  • National Maternity Hospital

    Dublin, Co. Dublin, D02YH21

    Anna Curley, Consultant Neonatology, 00353, anna.curley@nmh.ie

    Anna Curley, Consultant Neonatology, 003531637300, anna.curley@nmh.ie

    Recruiting
  • National Maternity Hospital

    Dublin, Co.Dublin, D02YH21

    Suspended

Other trials in Ireland

About this study

Official title: Maximising Initial Lactation Quantities for Preterm Infants (The MILQ Prem Study) Daily Breast Milk Volume in Mothers of Preterm Born at or < 33 Weeks or VLBW 1500gm. Randomized Controlled Trial Comparing Hospital Grade Double Electrical Breast Pump Expression Versus Hand Expression

Maternal milk is the gold standard in infant nutrition, providing significant advantages, in preterm and term infants. Maternal milk plays a major role in reducing the risk of inflammatory bowel disease(NEC) in premature and low birth weight infants as well as improving neurodevelopmental outcomes in this population, In this study the investigators are comparing earlier (from birth rather than 48 hours post delivery) use of an electrical breast pump. Mothers will be selected at random to be in one of two groups: early or later pump use. The investigators will compare milk volumes achieved on day 14 post delivery between the two groups. The investigators will recruit x number of mothers of preterm infants < 33 weeks gestation at birth

Read the detailed description

Evidence suggests that the first two weeks after premature delivery are a critical period for initiation and development of lactation. The process is made more complicated following preterm delivery due to immaturity of mammary glands and absence of sucking by premature infants . Preterm delivery also leads to increased levels of stress and anxiety about breast milk expression, especially during the first days after delivery . All these factors can contribute to low milk volumes and reduced nutritional substrate for babies. Inadequate breast milk production during the first few days after delivery leads to longer duration of parenteral nutrition and increased use of donor milk Donor milk is less effective nutritionally and an expensive resource. In babies where donor milk provides sup optimal nutrition, formula milk is required, and this significantly increases the risk of inflammatory bowel disease in preterm infants Suboptimal milk supply is also associated with prolonged use of central lines, greater rates of sepsis and chronic lung disease and prolongation of hospital stay.

International guidelines for production of expressed breast milk (EBM) for premature infants under 34 weeks' gestation from tertiary-level hospitals in Canada, Australia, and the United Kingdom suggest starting with hand expression of milk ideally within the first 1- 3 hours as a gold standard and if that is not possible within the first six hours after delivery, they recommend switching to a double electrical breast pump after the first 24-48 hours post-delivery. Use of hand expression in the first instance is based on the small volumes of colostrum which are likely to be collected. There is no evidence to say whether hand or electrical pump expression from birth is more effective. Hand expression for seven days from birth has been shown to be less effective than pump expression over the same time period but there have been no published studies to compare hand expression as per international guidelines for 2 days followed by use of the electric pump, to use of electric pump from birth .

Currently in our neonatal unit , the recommendation that mothers start expressing breast milk early after delivery initially expressing by hand and then changing to the electric pump from 48 hours. Earlier use of the electric pump may be more effective than hand expression. In this study, the investigators would like to compare use of the electrical pump on on day 1 rather than waiting for 48 hours and compare milk output by 2 weeks of age in the two groups.

Participants will be randomly assigned to one of these two groups:

  • Group A: Mothers will hand-express milk for the first two days post-delivery, followed by the use of a hospital-grade electric pump from day 3.
  • Group B: Mothers will begin using a hospital-grade electric pump immediately after delivery, followed by hand expression for 10 minutes for the first two days after delivery, and then continue to use the electric pump alone.
Being tested
Hospital grade double electrical breast milk pump
Keywords
expressed breast milk, lactation, premature feeding, coming to volume, early pump use
Medical subject headings
Breast Feeding, Premature Birth

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Hospital grade double electrical breast milk pumpDevice

    Also called Breast pump, Electrical breast pump, Hospital grade electrical pump

    Mothers assigned to the early pump group will be advised to start pumping using a hospital-grade double electrical breast pump as soon after birth(target within first 6 hours after delivery) follow by hand expression for 10 minutes for the first 48 hours then start using a hospital -grade double electrical breast pump.

Study groups in NCT07908238
Study groupRoleWhat they receive
Early expression groupActive comparatorINTERVENTION: Mothers assigned to the early pump group will be advised to start pumping using a hospital-grade double electrical breast pump as soon after birth (target will be within first 6 hours after delivery) followed by hand expression for 10 minutes. This will occur for the first 48 hours after delivery and then mothers will start using a hospital -grade double electrical breast pump without additional hand expression.
Receives: Device: Hospital grade double electrical breast milk pump
Late expression groupOtherCONTROL: Late pumping group: Mothers assigned to the late pumping group will be advised to start hand expression for the first 48 hours postpartum, and then start using a hospital-grade double electrical breast pump, as per routine practice.
Receives: Device: Hospital grade double electrical breast milk pump

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Percentage of women achieving > 500mls expressed breast milk by 14 days' post-partum

    Measured: from enrolment to two weeks post delivery

  2. Percentage of women achieving > 500mls by 14 days' post-partum in mothers of preterm infants < 33 weeks gestation and/or 1500 gram

    Mothers of preterm infants <33 weeks and /or 1500 gram will randomly assigned to early breast pumping group or late breast pumping group as outlined above , the primary outcome is the achieving of more than 500 ml of breast milk by day 14 post delivery.

    Measured: Milk amount from time of enrolment to two weeks post delivery

Secondary outcomes (12)
  1. Parenteral nutrition days

    Total days of parenteral nutrition until reaching to full feed

    Measured: From the time of enrolment until 6 weeks post menstrual age

  2. Time to full feeds

    How many days required to reach full feed

    Measured: From date of randomization until reaching fullfeed

  3. Donor milk use

    The number of participants who required donor milk from birth until discharge

    Measured: From the time of enrolment until 6 weeks post menstrual age

  4. Central line associated blood stream infections

    The number of participants with any documented central line infection from birth until discharge from hospital .Catheter-related bloodstream infection Clinical signs of sepsis and positive peripheral blood culture in the absence of an obvious source other than CVC with one of the following:

    Positive semiquantitative (>15 CFU) or quantitative (>103 CFU) culture from a part of the catheter with the same organisms isolated peripherally Simultaneous quantitative blood cultures with a ratio of ≥3:1 (CVC vs. peripheral) Time difference of ≤2 hours leading to culture positive between CVC and peripheral cultures.

    Central line-associated bloodstream infection is primary bloodstream infection in a patient who had a central line within the 48 hours period before development of infection.

    Measured: From the time of enrolment until 6 weeks post menstrual age

  5. Necrotising enterocolitis

    The number of participants who had any episode of necrotizing enterocolitis as defined by Modified Bell's staging criteria from enrolment to discharge.

    Measured: From the time of enrolment until 6 weeks post menstrual age

  6. Chronic lung disease

    Total numbers of days of respiratory support for the participant

    Measured: From the time of enrolment until 6 weeks post menstrual age

  7. Late onset sepsis

    The number of participants who had any documented late onset sepsis, described as documented infection after 72 hours after birth .

    Measured: From the time of enrolment until 6 weeks post menstrual age

  8. Breastfeeding at hospital discharge

    The number of participants involved in the study discharged home on breast feeding

    Measured: From the time of enrolment until 6 weeks post menstrual age

  9. Death before hospital discharge

    The number of participants ,time and cause of death during the study period

    Measured: From birth to time and date of death

  10. Duration of hospitalisation

    To duration in days of hospital stay from birth until discharge from hospital

    Measured: From date of randomization until the date of discharge home

  11. Parental attitudes and experiences (interviews with parents to access and enhance family centre care model)

    During study period , we are going to carry out interview with parents on level of education during antenatal period on the use of hospital breast pumping , when and how to access breast pumping device , pain associated with hand expression and breast pumping device . Level of education and support during first weeks after delivery . Added more , we are going to perform eduction sessions to the postnatal and delivery wards staff , NICU staff including Consultants , junior doctors and nursing staff .

    Measured: From time of birth to discharge from hospital

  12. Formula milk

    The number of participants who used of formula milk at any stage after birth until discharge from hospital

    Measured: From the time of enrolment until 6 weeks post menstrual age

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted2 Nov 2026
  2. Study start7 Nov 2025
  3. Primary completion1 Jul 2027 (estimated)
  4. Study completion1 Sep 2027 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Model description
(P) Among mothers of infants born at or \< 33 weeks of gestation or with a birth weight \<1500g (I) does the use of a hospital-grade double electrical breast pump as soon as possible after delivery followed by hand expression for 10 minutes, for the first 48 hours post-delivery followed by hospital grade double electrical breast pump (C) compared to routine hand milk expression for the first 48 hours post-delivery followed by hospital-grade double electrical breast pump (O) increase the volume of breast milk produced by mothers (T) by 14 days postpartum
Masking
None (open label)
Enrolment
160 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07908238
Sponsor's protocol ID
National Maternity Hospital
Acronym
MILQ prem
Status last verified
Oct 2026
First submitted
29 Sep 2025
Last updated
2 Nov 2026
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Yes: IPD may be shared following publication following reasonable ethically approved request

Questions about this trial

What is this clinical trial studying?

A study testing Hospital grade double electrical breast milk pump in people with Breastfeeding and Prematurity, run by National Maternity Hospital, Ireland at 3 sites in Ireland.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: looking for participants now, as of the sponsor's last update on 2 Nov 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 3 sites in Ireland. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

Contact Anna Curley, Consultant Neonatologist (003531637300, anna.curley@nmh.ie), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Percentage of women achieving > 500mls expressed breast milk by 14 days' post-partum (time frame: from enrolment to two weeks post delivery). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 2 Nov 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in