AzTrials
AzTrials

Dental BondingNCT07861178

Segmented Indirect Versus Direct Bracket Bonding

A study testing Direct bonding and Segmented modified indirect bonding in people with Dental Bonding and Orthodontic Brackets, run by Riyadh Elm University at 1 site in Saudi Arabia.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

This randomized clinical trial compared two methods of attaching orthodontic brackets to teeth: conventional direct bonding, in which each bracket is placed and bonded individually in the mouth, and a segmented modified indirect bonding technique, in which brackets are first positioned on a plaster model of the… Read more about this study

Who is it for?
Any ageHealthy volunteers can take part
Conditions the study is for
Dental Bonding, Orthodontic Brackets
What is being tested?
Direct bonding and Segmented modified indirect bonding
Type of treatment
Surgery or procedure
Could I receive a placebo?
No, everyone receives an active treatment
How many people
18 participants
Where
1 siteSaudi Arabia
Study dates
22 Nov 2020to 19 Oct 2021
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages Any age
  • All sexes
  • Healthy volunteers accepted
  • Child, Adult, Older adult

Who may be able to join

  • Patients seeking fixed-appliance orthodontic treatment
  • Permanent dentition
  • Teeth to be bonded free of crowns, bridges, veneers, restorations, or enamel hypoplasia

Who cannot join

  • Overbite greater than 3 mm
  • Teeth with crowns, bridges, veneers, restorations, or enamel hypoplasia
  • Severely rotated or blocked-out teeth
  • Partially erupted teeth

Trial locations and contacts

1 site in 1 country.

Saudi Arabia1 site
  • Riyadh Elm university

    Riyadh, Riyadh Region, 12734

Other trials in Saudi Arabia

About this study

Official title: Bond Failure of a Segmented Modified Indirect Bonding Technique Versus Direct Bonding: A Randomized Clinical Trial

This randomized clinical trial compared two methods of attaching orthodontic brackets to teeth: conventional direct bonding, in which each bracket is placed and bonded individually in the mouth, and a segmented modified indirect bonding technique, in which brackets are first positioned on a plaster model of the patient's teeth and then transferred to the mouth in segments using a hot-glue transfer tray. The purpose was to find out whether the two techniques differ in how often brackets come loose (bond failure) during treatment.

Eighteen patients receiving fixed orthodontic appliances at Riyadh Elm University, Riyadh, Saudi Arabia, were randomly assigned so that their brackets were placed by either the direct or the modified indirect technique. The same bracket type and adhesive were used in both groups. Patients were examined every four weeks for six months, and any bracket that debonded was recorded along with the tooth involved, the arch (upper or lower), the side (right or left), and the time from bonding to failure. The main outcome was the time from bonding to bracket failure; the investigators also compared failure rates and examined whether failure varied by tooth type, arch, or side.

Read the detailed description

Background and rationale: Direct bonding, in which orthodontic brackets are positioned and light-cured individually on each tooth, remains the most common technique but depends heavily on operator visibility and isolation at the moment of placement, which is constrained on posterior teeth. Indirect bonding positions brackets on a working cast under direct vision and transfers them to the dentition in a tray, and has been proposed to improve placement and reduce chairside time. Whether indirect bonding reduces clinical bond failure compared with direct bonding is not established, and clinical failure data for low-cost analogue (hot-glue) transfer-tray methods are limited.

Objective: To compare time to bracket bond failure (primary outcome) and bond-failure rate (secondary outcome) between conventional direct bonding and a segmented modified indirect bonding technique, and to examine whether failure varied by tooth type, arch, or side.

Design: Prospective, parallel-arm, single-center randomized clinical trial. Participants were allocated by simple randomization from a computer-generated sequence to direct bonding or segmented modified indirect bonding. The trial was open-label, as the bonding technique could not be masked from the operator.

Setting: Orthodontic clinics, Riyadh Elm University, Riyadh, Saudi Arabia. Participants: Patients seeking fixed-appliance orthodontic treatment were screened against eligibility criteria. Patients with overbite greater than 3 mm; with crowns, bridges, veneers, restorations, or enamel hypoplasia on the teeth to be bonded; with severely rotated or blocked-out teeth; or with partially erupted teeth were excluded. Eighteen participants were enrolled after written informed consent.

Interventions: In the direct group, teeth were pumiced, etched with 37% phosphoric acid (Meta Etchant, Meta Biomed), rinsed thoroughly, and excess water was removed; Ortho Solo Universal Sealant and Bond Enhancer (Ormco) was applied, and brackets were bonded with Enlight light-cured adhesive (Ormco), then light-cured for 20 seconds occlusally and 20 seconds gingivally. In the modified indirect group, alginate impressions were poured in dental stone; brackets were fixed to the casts in planned positions; segmented transfer trays (separate segments for molars, premolar-canine, and lateral/central incisors per quadrant) were fabricated with thermal (hot) glue covering the occlusal and partial lingual surfaces, leaving the bracket exposed below the slot. Teeth were pumiced, etched with the same 37% phosphoric acid, rinsed thoroughly, and excess water was removed; Ortho Solo Universal Sealant and Bond Enhancer was applied to the etched teeth and Enlight adhesive to the bracket bases before tray insertion; the trays were then seated and light-cured for 20 seconds before removal. The same bracket type and adhesive system were used in both arms.

Outcomes: The primary outcome was time to bracket bond failure (days from bonding to first debonding); the secondary outcome was the bond-failure rate. Each event was recorded with the tooth, arch (maxilla/mandible), side (right/left), date, and time from bonding to failure in days. The unit of analysis was the individual bracket. Participants were reviewed every four weeks for six months; debonded brackets were re-bonded directly.

Analysis: Time to failure was analysed with Kaplan-Meier estimates, the log-rank test and Cox proportional-hazards regression. Failure rates were compared with chi-square and exact tests and Firth penalized logistic regression, with an exploratory Holm-corrected analysis of technique by tooth type and side.

Being tested
Direct bonding, Segmented modified indirect bonding
Keywords
Orthodontic brackets, Dental bonding, Indirect bonding, Direct bonding, Bracket bond failure, Bracket debonding, Bond failure rate, Fixed orthodontic appliances

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Direct bondingProcedure or surgery

    Orthodontic brackets bonded individually onto each tooth intraorally. Teeth were pumiced, etched with 37% phosphoric acid (Meta Etchant, Meta Biomed), rinsed thoroughly, and excess water was removed; Ortho Solo Universal Sealant and Bond Enhancer (Ormco) was applied to the teeth, and each bracket was seated with Enlight light-cured adhesive (Ormco) along the tooth's long axis, vertical height, and mesiodistal midline, then light-cured for 20 seconds occlusally and 20 seconds gingivally. The same bracket type and adhesive system were used as in the experimental arm.

  • Segmented modified indirect bondingProcedure or surgery

    Orthodontic brackets positioned on a dental stone cast in their planned locations and transferred to the teeth using segmented hot-glue (thermal-glue) transfer trays, fabricated separately for molar, premolar-canine, and lateral and central incisor segments in each quadrant. Teeth were pumiced, etched with 37% phosphoric acid (Meta Etchant, Meta Biomed), rinsed thoroughly, and excess water was removed; Ortho Solo Universal Sealant and Bond Enhancer (Ormco) was applied to the etched teeth and Enlight light-cured adhesive (Ormco) to the bracket bases before tray insertion; the tray was then seated, light-cured for 20 seconds, and removed. The same bracket type and adhesive system were used as in the comparator arm.

Study groups in NCT07861178
Study groupRoleWhat they receive
Direct bondingActive comparatorOrthodontic brackets were bonded directly onto each tooth in the mouth. Teeth were pumiced, etched with 37% phosphoric acid (Meta Etchant, Meta Biomed), rinsed thoroughly, and excess water was removed. Ortho Solo Universal Sealant and Bond Enhancer (Ormco) was applied to the teeth, and each bracket was seated with Enlight light-cured adhesive (Ormco) along the tooth's long axis, vertical height, and mesiodistal midline, then light-cured for 20 seconds occlusally and 20 seconds gingivally. This arm comprised 160 brackets.
Receives: Procedure: Direct bonding
Segmented modified indirect bondingExperimentalOrthodontic brackets were first positioned on a dental stone cast in their planned locations, then transferred to the teeth using segmented hot-glue transfer trays (separate segments for molars, premolar-canine, and lateral and central incisors in each quadrant). Teeth were pumiced, etched with 37% phosphoric acid (Meta Etchant, Meta Biomed), rinsed thoroughly, and excess water was removed. Ortho Solo Universal Sealant and Bond Enhancer (Ormco) was applied to the etched teeth and Enlight light-cured adhesive (Ormco) to the bracket bases; the tray was then seated, light-cured for 20 seconds, and removed. This arm comprised 224 brackets.
Receives: Procedure: Segmented modified indirect bonding

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Time to bracket bond failure (time to debond)

    For each bonded bracket, the number of days from bracket placement (bonding) to the first bond failure (debonding). A bracket still bonded at the end of follow-up is right-censored at the date of its last assessment. Only the first failure per bracket is the event; debonded brackets that were re-bonded are not re-entered.

    Measured: 6 months from bonding

Secondary outcomes (3)
  1. Time to failure among debonded brackets

    For brackets that debonded, the time interval from initial bonding to the recorded failure, measured in days.

    Measured: 6 months from bonding

  2. Bracket bond failure rate

    Proportion of bonded brackets that debonded (bond failure) during the follow-up period. Each tooth was examined at four-weekly recall visits; a bracket was recorded as failed if it had detached from the tooth. Failure was assessed at the individual-bracket level and expressed as the percentage of brackets that debonded in each group.

    Measured: 6 months from bonding

  3. Bracket bond failure by tooth type, arch, and side

    Bracket bond-failure rate compared across tooth type (incisor, canine, premolar, molar), arch (maxilla, mandible), and side (right, left), to assess whether failure varied by bracket location.

    Measured: 6 months from bonding

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted6 Oct 2026
  2. Study start22 Nov 2020
  3. Primary completion19 Oct 2021
  4. Study completion19 Oct 2021

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
None (open label)
Enrolment
18 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07861178
Sponsor's protocol ID
FPGRP/2020/525/334/328
Status last verified
Sep 2026
First submitted
31 May 2026
Last updated
6 Oct 2026
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Almosa N, Zafar H. Incidence of orthodontic brackets detachment during orthodontic treatment: A systematic review. Pak J Med Sci. 2018 May-Jun;34(3):744-750. doi: 10.12669/pjms.343.15012.

    PubMed 30034451
  • Aguirre MJ, King GJ, Waldron JM. Assessment of bracket placement and bond strength when comparing direct bonding to indirect bonding techniques. Am J Orthod. 1982 Oct;82(4):269-76. doi: 10.1016/0002-9416(82)90461-4.

    PubMed 6760721

Questions about this trial

What is this clinical trial studying?

A study testing Direct bonding and Segmented modified indirect bonding in people with Dental Bonding and Orthodontic Brackets, run by Riyadh Elm University at 1 site in Saudi Arabia.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 6 Oct 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Saudi Arabia. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Time to bracket bond failure (time to debond) (time frame: 6 months from bonding). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT07861178, which also lists 2 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 6 Oct 2026.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in