AzTrials
AzTrials

Kidney Failure, ChronicRAfALREINNCT07851571

Drone Transport of Deceased-Donor Kidney Grafts Between Two French Hospitals Before Transplantation: a Pilot Safety Study

A study testing Kidney graft transport by autonomous unmanned aircraft (drone) between the procurement and transplantation centres in people with Kidney Failure, Chronic and Kidney Transplantation, run by Nantes University Hospital.

Not yet recruiting

Opening soon. The study is approved but enrolment has not started yet. Sites may already take enquiries.

Sites and contacts
Official record

Search all trials

Trial summary

Cold ischemia time, the period during which a donated kidney is kept cold outside the body between its removal from the donor and its transplantation into the recipient, is one of the main modifiable factors influencing how quickly and how well a transplanted kidney starts to work and how long it lasts. Read more about this study

Who is it for?
Ages 18 years and older
What is being tested?
Kidney graft transport by autonomous unmanned aircraft (drone) between the procurement and transplantation centres
Could I receive a placebo?
No, everyone receives an active treatment
How many people
5 participants
Where
No sites listed yet
Study dates
15 Jan 2027to 1 Jul 2028
Phase
Interventional

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Male or female aged 18 years or older, scheduled to receive a kidney transplant at Nantes University Hospital from a deceased donor (brain death or controlled donation after circulatory death)
  • Kidney graft procured at CHD Vendée (La Roche-sur-Yon) and effectively transported by drone (study population, protocol section 5.1)
  • Affiliation to a social security scheme
  • Oral consent to participate, recorded in the medical file (inclusion on the day of transplantation, day 0)
  • Donor criteria: donor aged 18 years or older, brain-dead donor or controlled donation after circulatory death

Who cannot join

  • Adult under guardianship or curatorship
  • Pregnant or breastfeeding woman

Trial locations and contacts

No sites are listed yet. Contact the study team or a site near you to ask about taking part.

Julien Branchereau, MD PhD contact

+33 2 40 08 39 10

julien.branchereau@chu-nantes.fr

About this study

Official title: Transport of Kidney Grafts by Drone for Inter-Center Transplantation: a Safety Study. Towards a French First (RAfALREIN)

Cold ischemia time, the period during which a donated kidney is kept cold outside the body between its removal from the donor and its transplantation into the recipient, is one of the main modifiable factors influencing how quickly and how well a transplanted kidney starts to work and how long it lasts. In France, kidneys are usually transported between hospitals by ambulance, car, train or plane, which exposes the graft to traffic, scheduling and coordination delays. Autonomous drones could offer a fast, dedicated and predictable alternative. A human kidney was successfully transplanted after drone transport in the United States in 2019, but no transplantation after drone transport of an organ has yet been reported in Europe.

The RAfALREIN study is a pilot study designed to assess the safety and feasibility of transporting deceased-donor kidneys by autonomous drone between the Centre Hospitalier Départemental Vendée in La Roche-sur-Yon (procurement site) and Nantes University Hospital (transplantation site), within a dedicated medical air corridor subject to authorisation by the French civil aviation authority. Five adult patients will receive a kidney that has been transported by drone. Apart from the mode of transport of the graft, organ procurement, preservation, transplantation, treatments and follow-up are carried out according to usual care, with no additional examination required by the study.

Read more

The main outcome is the absence of delayed graft function, defined as no need for dialysis during the first week after transplantation. Cold ischemia time, transport time, temperature and vibrations during transport, transport costs, events preventing, delaying or interrupting drone missions, and adverse events up to 30 days after transplantation are also recorded. Participants are followed for 12 months after transplantation as part of routine care.

Study hypothesis: transport of kidney grafts by autonomous drone between two hospitals is safe, does not impair early graft function and is operationally feasible in real conditions, thereby supporting the design of a larger multicentre study.

Read the detailed description

Background. Cold ischemia time (CIT) is the main modifiable determinant of delayed graft function (DGF) and of medium- and long-term kidney graft survival; each additional hour of CIT increases the risk of graft failure and mortality. The French Ministerial Plan for Organ and Tissue Procurement and Transplantation 2022-2026 set a target mean CIT of 10 hours or less for kidney transplantation and explicitly identified drone transport of grafts as a priority lever, whereas national median CIT for deceased-donor kidney transplantation remains around 14-15 hours. Conventional transport modes (road, rail, chartered or commercial flights) are exposed to traffic, timetables, airport procedures and coordination constraints, and dedicated non-commercial flights carry a non-negligible accident risk. Unmanned aircraft systems (UAS) are already used in national medical logistics networks (blood products, vaccines, laboratory samples) and in hospital corridor programmes in the United Kingdom. In 2019, the University of Maryland Medical Center performed the first kidney transplantation after drone transport of the graft, with stable temperature, vibration levels lower than in commercial aviation and no macroscopic or histological alteration. In Europe, work on organ transport by drone remains limited to feasibility and logistic modelling studies, without reported human transplantation.

Preliminary work. Nantes University Hospital (kidney transplant unit, 160-180 kidney transplantations per year) and the organ procurement coordination of CHD Vendée have collaborated for more than ten years; Nantes receives 15 to 20 kidneys procured in La Roche-sur-Yon each year. On 2 June 2024, both centres performed an experimental drone transport of a porcine kidney on the exact route planned for this study (La Roche-sur-Yon to Nantes), with full recording of flight parameters (temperature, vibrations, flight time), absence of macroscopic graft alteration and confirmation of graft function after auto-transplantation following bilateral nephrectomy. The study also aims to determine whether drone transport reduces graft exposure to shocks and thermal variations before any extension to other transplant centres.

Design. Prospective, bicentric, open-label, non-randomised, single-arm pilot study including 5 kidney transplant recipients. The procurement centre is CHD Vendée (La Roche-sur-Yon); the transplantation centre is Nantes University Hospital. The study is a first step towards a larger study (letter of intent submitted to the French PREPS programme, DGOS, December 2025).

Transport chain. After standard procurement, the kidney is packaged in a refrigerated container clinically approved for graft transport, using either static cold storage or hypothermic machine perfusion (both modes may be used in the study). The container is flown by an autonomous vertical take-off and landing fixed-wing drone (RigiTech Eiger: maximum take-off mass 21 kg, maximum payload 3 kg / 15 L, cruise speed about 104 km/h, operational wind limits 12 m/s in multirotor phase and 15 m/s in fixed-wing phase; ballistic parachute with independent failsafe unit, redundant navigation sensors, dual command-and-control links). Flights are operated beyond visual line of sight by the specialised operator Delivrone within the European 'specific' category framework, on the basis of a SORA risk assessment (SAIL II) and an operational authorisation from the French civil aviation safety directorate (DSAC), within a dedicated medical air corridor between La Roche-sur-Yon and Nantes (about 62 km as the crow flies; 75 to 88 km along the planned flight path).

Data recorded. Donor characteristics (age, sex, donor type, anthropometry, cause of death, cardiovascular history, cardiac arrest, last-hour diuresis, creatinine, proteinuria, haematuria, vasopressors); complete transport timeline (ground transfer before flight, loading, flight, ground transfer after landing); temperature and three-axis vibrations measured by a sterile sensor in contact with the graft; perfusion machine alarms if applicable; weather and corridor data and any technical incident; pre-implantation biopsy (acute glomerular, interstitial, tubular, vascular and peritubular capillary lesions, infarction or haemorrhage); recipient and surgical data (cold and warm ischemia, number of arteries, ureteral stent, time on waiting list and on dialysis); early graft function during the first post-operative week (dialysis sessions, primary non-function, serum creatinine, estimated glomerular filtration rate); follow-up visits at D10-D30, M1-M3 and M3-M12 (biology, urinalysis, ultrasound as clinically indicated, uro-vascular complications, maintenance immunosuppression, return to dialysis, graft nephrectomy, death). All clinical data derive from routine care.

Missions not completed by drone. If the drone cannot take off (adverse weather, winds above operational limits, regulatory unavailability or saturation of the corridor, technical issue) or if the mission is interrupted in flight (automatic return to base or landing in a predefined safe area), the graft is immediately transferred by conventional transport according to standard pathways, with no loss of chance for the recipient. In that case the recipient is not included in the drone-transport analysis, but every planned mission, including delayed, cancelled or aborted missions, is systematically documented and analysed to identify limiting factors.

Statistical analysis. Analyses are descriptive. The primary outcome is expressed as the proportion of recipients without DGF with its exact 95% confidence interval (Clopper-Pearson). Quantitative secondary outcomes are described (mean, standard deviation, median, minimum, maximum) with individual presentation by patient and by mission. No comparative or confirmatory analysis, no significance threshold, no interim analysis and no imputation of missing data are planned. The analysis population comprises all recipients transplanted with a graft effectively transported by drone (as treated); the transport safety analysis includes all planned drone missions.

Budget impact. Transport costs of the study grafts, based on invoices, will be compared with mean transport costs observed in 2024 and 2025 (between Nantes and CHD Vendée, and between these centres and other national centres), from the hospital perspective, with a projection of the annual financial impact of deploying drone transport at Nantes University Hospital.

Being tested
Kidney graft transport by autonomous unmanned aircraft (drone) between the procurement and transplantation centres
Keywords
Unmanned Aerial Devices, Drone, Organ transport, Tissue and Organ Procurement, Organ Preservation, Cold Ischemia, Kidney graft, Deceased donor, Hypothermic machine perfusion, Static cold storage, Beyond visual line of sight flight, Medical air corridor, Transplantation logistics
Medical subject headings
Kidney Failure, Chronic, Delayed Graft Function

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Kidney graft transport by autonomous unmanned aircraft (drone) between the procurement and transplantation centresOther

    After standard procurement at CHD Vendée, the kidney is packaged in a refrigerated container clinically approved for graft transport (static cold storage or hypothermic machine perfusion) and flown to Nantes University Hospital by an autonomous vertical take-off and landing fixed-wing drone (RigiTech Eiger, payload up to 3 kg), operated beyond visual line of sight by Delivrone within a dedicated air corridor subject to French civil aviation (DSAC) authorisation. Temperature, three-axis vibrations (sterile sensor in contact with the graft), each transport phase duration and any incident are recorded. The graft is then transplanted according to standard surgical practice. In case of no take-off or in-flight interruption, conventional transport is used.

Study groups in NCT07851571
Study groupRoleWhat they receive
Drone-transported kidney graftExperimentalAdult recipients transplanted at Nantes University Hospital with a deceased-donor kidney procured at CHD Vendée (La Roche-sur-Yon) and transported to Nantes by autonomous drone. Procurement, preservation (static cold storage or hypothermic machine perfusion), transplantation, immunosuppression and 12-month follow-up are performed according to standard care. If the drone cannot take off or the mission is interrupted, the graft is transferred by conventional transport and the recipient is not included; the mission is recorded for the transport safety analysis.
Receives: Other: Kidney graft transport by autonomous unmanned aircraft (drone) between the procurement and transplantation centres

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Absence of delayed graft function (no dialysis during the first week after kidney transplantation)

    Safety of kidney graft transport by autonomous drone assessed through early graft function. Delayed graft function is defined as the need for at least one dialysis session during the first 7 days after transplantation. Results are expressed as the proportion of recipients without delayed graft function, with its exact 95% confidence interval (Clopper-Pearson method). Recipients with missing information on dialysis within 7 days are considered non-evaluable and the number of evaluable recipients is reported.

    Measured: From transplantation (day 0) to day 7 post-transplantation

Secondary outcomes (7)
  1. Cold ischemia time

    Duration of cold ischemia of the drone-transported graft, in minutes; mean, standard deviation, median, minimum and maximum, and individual values per graft.

    Measured: Day 0 (from donor aortic cross-clamping to graft reperfusion in the recipient)

  2. Transport duration

    Door-to-door transport time in minutes, detailed by phase: ground transfer before flight, loading of the container into the drone, flight time, ground transfer after landing.

    Measured: Day 0 (from departure of the graft from the procurement operating room to arrival at the transplantation operating room)

  3. Temperature during transport

    Mean temperature (°C) recorded inside the transport container during the mission, with minimum and maximum values.

    Measured: Day 0 (continuous recording throughout the drone mission)

  4. Vibrations during transport

    Mean acceleration (G) per transport and per graft along three axes, measured by a sterile accelerometer placed in contact with the graft.

    Measured: Day 0 (continuous recording throughout the drone mission)

  5. Budget impact of drone transport

    Mean transport cost of the 5 study grafts (based on invoices) compared with the mean graft transport cost observed in 2024 and 2025 (Nantes-CHD Vendée and these centres-other national centres), from the hospital perspective, with projection of the annual financial impact of a drone transport deployment at Nantes University Hospital

    Measured: At the end of the study (after the last drone mission)

  6. Safety and reliability of drone missions

    Number, frequency and narrative description of events that prevented take-off, delayed or led to the abortion of a planned drone mission (weather, air corridor unavailability, technical failure, loss of link, crash), including missions for which the graft was finally transferred by conventional transport.

    Measured: Day 0 (each planned drone mission)

  7. Adverse events up to 30 days after transplantation

    Number, frequency and description of adverse events occurring in recipients up to day 30 after transplantation.

    Measured: From transplantation (day 0) to day 30

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted1 Oct 2026
  2. Study start15 Jan 2027 (estimated)
  3. Primary completion1 Jul 2027 (estimated)
  4. Study completion1 Jul 2028 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Health services research
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
5 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07851571
Sponsor's protocol ID
RC26_0328
Acronym
RAfALREIN
Status last verified
Sep 2026
First submitted
25 Sep 2026
Last updated
1 Oct 2026
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No: Pilot study including 5 participants; given the very small sample and the unique nature of the procedure, individual data could allow re-identification. Aggregated results will be published.

Publications

  • Karpstein R, Brolli J, Stiegler P, Sucher R, Holzapfel F, Biberthaler P. Evaluation of the advanced air mobility potential for organ transplantation in Austria and Germany. Sci Rep. 2024 Nov 30;14(1):29782. doi: 10.1038/s41598-024-81045-2.

    PubMed 39616204
  • Gilmour RG, Hoff M. Drone-Assisted Organ Transport: A Scoping Review of Clinical, Regulatory, and System Readiness. Clin Transplant. 2025 Dec;39(12):e70398. doi: 10.1111/ctr.70398.

    PubMed 41383068
  • Scalea JR, Pucciarella T, Talaie T, Restaino S, Drachenberg CB, Alexander C, Qaoud TA, Barth RN, Wereley NM, Scassero M. Successful Implementation of Unmanned Aircraft Use for Delivery of a Human Organ for Transplantation. Ann Surg. 2021 Sep 1;274(3):e282-e288. doi: 10.1097/SLA.0000000000003630.

    PubMed 31663974
  • Scalea JR, Restaino S, Scassero M, Blankenship G, Bartlett ST, Wereley N. An Initial Investigation of Unmanned Aircraft Systems (UAS) and Real-Time Organ Status Measurement for Transporting Human Organs. IEEE J Transl Eng Health Med. 2018 Nov 6;6:4000107. doi: 10.1109/JTEHM.2018.2875704. eCollection 2018.

    PubMed 30464862
  • Sylverken AA, Owusu M, Agbavor B, Kwarteng A, Ayisi-Boateng NK, Ofori P, El-Duah P, Yeboah R, Aryeetey S, Addo Asamoah J, Ekekpi RZ, Oppong M, Gorman R, Brempong KA, Nyarko-Afriyie E, Owusu Bonsu F, Larsen-Reindorf R, Rockson Adjei M, Boateng G, Asiedu-Bekoe F, Sarkodie B, Laryea DO, Tinkorang E, Kumah Aboagye P, Nsiah Asare A, Obiri-Danso K, Owusu-Dabo E, Adu-Sarkodie Y, Phillips RO. Using drones to transport suspected COVID-19 samples; experiences from the second largest testing centre in Ghana, West Africa. PLoS One. 2022 Nov 1;17(11):e0277057. doi: 10.1371/journal.pone.0277057. eCollection 2022.

    PubMed 36318579
  • Nisingizwe MP, Ndishimye P, Swaibu K, Nshimiyimana L, Karame P, Dushimiyimana V, Musabyimana JP, Musanabaganwa C, Nsanzimana S, Law MR. Effect of unmanned aerial vehicle (drone) delivery on blood product delivery time and wastage in Rwanda: a retrospective, cross-sectional study and time series analysis. Lancet Glob Health. 2022 Apr;10(4):e564-e569. doi: 10.1016/S2214-109X(22)00048-1.

    PubMed 35303465
  • Debout A, Foucher Y, Trebern-Launay K, Legendre C, Kreis H, Mourad G, Garrigue V, Morelon E, Buron F, Rostaing L, Kamar N, Kessler M, Ladriere M, Poignas A, Blidi A, Soulillou JP, Giral M, Dantan E. Each additional hour of cold ischemia time significantly increases the risk of graft failure and mortality following renal transplantation. Kidney Int. 2015 Feb;87(2):343-9. doi: 10.1038/ki.2014.304. Epub 2014 Sep 17.

    PubMed 25229341
  • van de Laar SC, Lafranca JA, Minnee RC, Papalois V, Dor FJMF. The Impact of Cold Ischaemia Time on Outcomes of Living Donor Kidney Transplantation: A Systematic Review and Meta-Analysis. J Clin Med. 2022 Mar 15;11(6):1620. doi: 10.3390/jcm11061620.

    PubMed 35329945
  • Scalea JR, Restaino S, Scassero M, Bartlett ST, Wereley N. The final frontier? Exploring organ transportation by drone. Am J Transplant. 2019 Mar;19(3):962-964. doi: 10.1111/ajt.15113. Epub 2018 Oct 4. No abstract available.

    PubMed 30203436
  • - Gavzy SJ, Scalea JR. Organ transportation innovations and future trends. Curr Transplant Rep. 2022;9:143-147.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in