AzTrials
AzTrials

Aortic Stenosis SenileSAFESYNC NGNCT07806409

Safety and Clinical Performance of the Next-Generation SAFESYNC Transcatheter Heart Valve in Patients With Severe Aortic Stenosis

A study testing INOVARE® SAFESYNC Next-Generation Bioprosthetic Heart Valve in people with Aortic Stenosis Senile and Aortic Stenosis Symptomatic, run by Braile Biomedica Ind. Com. e Repr. Ltda..

Not yet recruiting

Opening soon. The study is approved but enrolment has not started yet. Sites may already take enquiries.

Sites and contacts
Official record

Search all trials

Trial summary

The objective of this pivotal, prospective, multicenter, single-arm clinical trial is to evaluate the safety and clinical performance of the Next-Generation INOVARE® SAFESYNC Bioprosthetic Heart Valve, implanted via a transcatheter approach, in patients with severe aortic stenosis, an indication for TAVI, and… Read more about this study

Who is it for?
Ages 18 years and older
What is being tested?
INOVARE® SAFESYNC Next-Generation Bioprosthetic Heart Valve
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
40 participants
Where
No sites listed yet
Study dates
Nov 2026to Jun 2032
Phase
Interventional

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Severe aortic valve stenosis diagnosed according to criteria established in current guidelines.
  • Intermediate or higher surgical risk, defined as a Society of Thoracic Surgeons (STS) score ≥4%.
  • Indication for transcatheter aortic valve implantation (TAVI).
  • Willing and able to participate in the study and provide written informed consent.

Who cannot join

  • Any condition considered a contraindication to implantation of a bioprosthetic heart valve (e.g., indication for a mechanical heart valve).
  • Known hypersensitivity or contraindication to aspirin, clopidogrel, heparin, nitinol (titanium or nickel), or contrast media that cannot be adequately managed with premedication. This includes heparin-induced thrombocytopenia (HIT) or heparin-induced thrombocytopenia with thrombosis (HITTS).
  • Blood dyscrasias, including leukopenia (white blood cell count <1,000/mm³), thrombocytopenia (platelet count <100,000 cells/mm³), history of coagulopathy, or hypercoagulable states.
  • Active infection, including endocarditis.
  • Cardiogenic shock manifested by low cardiac output, vasopressor dependence, or requirement for mechanical hemodynamic support.
  • Stroke or transient ischemic attack (TIA) within 2 months prior to the index procedure.
Show all 18Show fewer
  • History of gastrointestinal bleeding or other bleeding that precludes anticoagulant or antiplatelet therapy.
  • Estimated life expectancy of less than 24 months.
  • Other medical, social, or psychological conditions that, in the investigator's opinion, may prevent the participant from providing informed consent or adequately complying with the study protocol.
  • Pre-existing prosthetic heart valve, either biological or mechanical, in the aortic position.
  • Concomitant severe mitral or tricuspid valve disease.
  • Hypertrophic obstructive cardiomyopathy.
  • Successful percutaneous coronary intervention (PCI) performed within 48 hours prior to TAVI.
  • Femoral artery diameter <5.5 mm for SAFESYNC 20-24 mm, <6.0 mm for SAFESYNC 26-28 mm, or <6.5 mm for SAFESYNC 30 mm.
  • High risk of aortic annular rupture or significant residual paravalvular leak due to severe calcification of the aortic valve or left ventricular outflow tract.
  • High risk of coronary obstruction, defined by computed tomography angiography as coronary ostial height <10 mm with narrow sinuses of Valsalva (SOV), with a mean SOV diameter <3 mm greater than the bioprosthetic valve size.
  • Left ventricular dysfunction with left ventricular ejection fraction (LVEF) ≤30%.
  • Severe chronic kidney disease, defined as glomerular filtration rate (GFR) <30 mL/min/1.73 m².

Trial locations and contacts

No sites are listed yet. Contact the study team or a site near you to ask about taking part.

Clinical Research Department - Braile Biomédica contact

+5517 21367000

pesquisa@braile.com.br

About this study

Official title: Evaluation of the Safety and Clinical Performance of the Next-Generation SAFESYNC Balloon-Expandable Transcatheter Heart Valve in Patients With Severe Aortic Stenosis: A Prospective, Multicenter, Single-Arm Pivotal Study

The objective of this pivotal, prospective, multicenter, single-arm clinical trial is to evaluate the safety and clinical performance of the Next-Generation INOVARE® SAFESYNC Bioprosthetic Heart Valve, implanted via a transcatheter approach, in patients with severe aortic stenosis, an indication for TAVI, and intermediate or higher surgical risk. The study will enroll 40 participants.

Being tested
INOVARE® SAFESYNC Next-Generation Bioprosthetic Heart Valve
Keywords
Aortic Valve Stenosis, Transcatheter Aortic Valve Implantation, TAVI, Balloon-Expandable Transcatheter Heart Valve
Medical subject headings
Aortic Valve Stenosis

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • INOVARE® SAFESYNC Next-Generation Bioprosthetic Heart ValveDevice

    Participants will undergo TAVI via transfemoral access using the INOVARE® SAFESYNC Next-Generation Bioprosthetic Heart Valve and the B-Delivery System.

Study groups in NCT07806409
Study groupRoleWhat they receive
INOVARE® SAFESYNC Next-Generation TAVIExperimentalNot described
Receives: Device: INOVARE® SAFESYNC Next-Generation Bioprosthetic Heart Valve

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Device Success According to VARC-3 Criteria

    Technical success; Absence of mortality; Absence of surgery or intervention related to the device or to major vascular, access-related, or cardiac structural complications; Intended valve performance, defined as mean transvalvular gradient <20 mmHg, peak velocity <3 m/s, Doppler velocity index ≥0.25, and less than moderate aortic regurgitation.

    Measured: 30 days after the procedure

Secondary outcomes (10)
  1. Percentage of Participants Achieving Technical Success According to VARC-3 Criteria

    Defined as freedom from mortality; successful vascular access, delivery of the device, and retrieval of the delivery system; correct positioning of a single prosthetic heart valve in the intended anatomical location; and freedom from surgery or intervention related to the device or to a major vascular, access-related, or cardiac structural complication. Results will be reported as the number and percentage of participants achieving technical success.

    Measured: During the procedure

  2. Incidence and Severity of Paravalvular Leak

    Paravalvular leak will be assessed by transthoracic echocardiography and classified according to severity. The number and percentage of participants with paravalvular leak in each severity category will be reported.

    Measured: 30 days, 6 months, 12 months, and annually through 5 years

  3. Mean Transvalvular Aortic Pressure Gradient Assessed

    Mean transvalvular aortic pressure gradient will be assessed by transthoracic echocardiography and reported in mmHg.

    Measured: 30 days, 6 months, 12 months, and annually through 5 years

  4. Distribution of Participants by New York Heart Association Functional Class

    Functional status will be assessed using the New York Heart Association (NYHA) Functional Classification. The classification ranges from Class I to Class IV, where Class I represents no limitation of physical activity and Class IV represents inability to perform physical activity without symptoms and/or symptoms at rest. Higher NYHA classes indicate worse functional status. Results will be reported as the number and percentage of participants in each NYHA functional class.

    Measured: 30 days, 6 months, 12 months, and annually through 5 years

  5. Incidence of New Permanent Pacemaker Implantation

    New permanent pacemaker implantation following the index transcatheter aortic valve implantation procedure will be assessed. Results will be reported as the number and percentage of participants who undergo new permanent pacemaker implantation.

    Measured: 30 days, 6 months, 12 months, and annually through 5 years

  6. Incidence of All-Cause Mortality

    All-cause mortality will be assessed throughout follow-up. Results will be reported as the number and percentage of participants who die from any cause.

    Measured: 30 days, 6 months, 12 months, and annually through 5 years

  7. Incidence of Stroke

    Stroke events will be assessed based on clinical neurological evaluation and classified according to Valve Academic Research Consortium 3 (VARC-3) definitions. Results will be reported as the number and percentage of participants experiencing stroke.

    Measured: 30 days, 6 months, 12 months, and annually through 5 years

  8. Incidence of Bioprosthetic Valve-Related Reintervention

    Bioprosthetic valve-related reintervention will be defined as any surgical or transcatheter intervention performed to treat dysfunction or failure of the implanted study valve. Results will be reported as the number and percentage of participants undergoing valve-related reintervention.

    Measured: 30 days, 6 months, 12 months, and annually through 5 years

  9. Incidence of Bioprosthetic Valve Dysfunction According to VARC-3 Definitions

    Bioprosthetic valve dysfunction will be assessed according to Valve Academic Research Consortium 3 (VARC-3) definitions. Bioprosthetic valve dysfunction includes structural valve deterioration, non-structural valve dysfunction, valve thrombosis, and endocarditis. Results will be reported as the number and percentage of participants meeting the criteria for bioprosthetic valve dysfunction and according to the corresponding category.

    Measured: 30 days, 6 months, 12 months, and annually through 5 years

  10. Incidence of Bioprosthetic Valve Failure According to VARC-3 Definitions

    Bioprosthetic valve failure will be assessed according to Valve Academic Research Consortium 3 (VARC-3) definitions. Results will be reported as the number and percentage of participants meeting the criteria for bioprosthetic valve failure.

    Measured: 30 days, 6 months, 12 months, 24 months, 36 months, 48 months, and 60 months after the index procedure

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted8 Sep 2026
  2. Study startNov 2026 (estimated)
  3. Primary completionJul 2027 (estimated)
  4. Study completionJun 2032 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
40 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07806409
Sponsor's protocol ID
SAFESYNC NG
Acronym
SAFESYNC NG
Status last verified
Sep 2026
First submitted
19 Aug 2026
Last updated
8 Sep 2026
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in